1.Study of adsorption of coated aldehyde oxy-starch on the indexes of renal failure
Qian WU ; Cai-fen WANG ; Ning-ning PENG ; Qin NIE ; Tian-fu LI ; Jian-yu LIU ; Xiang-yi SONG ; Jian LIU ; Su-ping WU ; Ji-wen ZHANG ; Li-xin SUN
Acta Pharmaceutica Sinica 2025;60(2):498-505
The accumulation of uremic toxins such as urea nitrogen, blood creatinine, and uric acid of patients with renal failure
2.Inhibition of HDAC3 Promotes Psoriasis Development in Mice Through Regulating Th17
Fan XU ; Xin-Rui ZHANG ; Yang-Chen XIA ; Wen-Ting LI ; Hao CHEN ; An-Qi QIN ; Ai-Hong ZHANG ; Yi-Ran ZHU ; Feng TIAN ; Quan-Hui ZHENG
Progress in Biochemistry and Biophysics 2025;52(4):1008-1017
ObjectiveTo investigate the influence of histone deacetylase 3 (HDAC3) on the occurrence, development of psoriasis-like inflammation in mice, and the relative immune mechanisms. MethodsHealthy C57BL/6 mice aged 6-8 weeks were selected and randomly divided into 3 groups: control group (Control), psoriasis model group (IMQ), and HDAC3 inhibitor RGFP966-treated psoriasis model group (IMQ+RGFP966). One day prior to the experiment, the back hair of the mice was shaved. After a one-day stabilization period, the mice in Control group was treated with an equal amount of vaseline, while the mice in IMQ group was treated with imiquimod (62.5 mg/d) applied topically on the back to establish a psoriasis-like inflammation model. The mice in IMQ+RGFP966 group received intervention with a high dose of the HDAC3-selective inhibitor RGFP966 (30 mg/kg) based on the psoriasis-like model. All groups were treated continuously for 5 d, during which psoriasis-like inflammation symptoms (scaling, erythema, skin thickness), body weight, and mental status were observed and recorded, with photographs taken for documentation. After euthanasia, hematoxylin-eosin (HE) staining was used to assess the effect of RGFP966 on the skin tissue structure of the mice, and skin thickness was measured. The mRNA and protein expression levels of HDAC3 in skin tissues were detected using reverse transcription real-time quantitative polymerase chain reaction (RT-qPCR) and Western blot (WB), respectively. Flow cytometry was employed to analyze neutrophils in peripheral blood and lymph nodes, CD4+ T lymphocytes, CD8+ T lymphocytes in peripheral blood, and IL-17A secretion by peripheral blood CD4+ T lymphocytes. Additionally, spleen CD4+ T lymphocyte expression of HDAC3, CCR6, CCR8, and IL-17A secretion levels were analyzed. Immunohistochemistry was used to detect the localization and expression levels of HDAC3, IL-17A, and IL-10 in skin tissues. ResultsCompared with the Control group, the IMQ group exhibited significant psoriasis-like inflammation, characterized by erythema, scaling, and skin wrinkling. Compared with the IMQ group, RGFP966 exacerbated psoriasis-like inflammatory symptoms, leading to increased hyperkeratosis. The psoriasis area and severity index (PASI) skin symptom scores were higher in the IMQ group than those in the Control group, and the scores were further elevated in the IMQ+RGFP966 group compared to the IMQ group. Skin thickness measurements showed a trend of IMQ+RGFP966>IMQ>Control. The numbers of neutrophils in the blood and lymph nodes increased sequentially in the Control, IMQ, and IMQ+RGFP966 groups, with a similar trend observed for CD4+ and CD8+ T lymphocytes in the blood. In skin tissues, compared with the Control group, the mRNA and protein levels of HDAC3 decreased in the IMQ group, but RGFP966 did not further reduce these expressions. HDAC3 was primarily located in the nucleus. Compared with the Control group, the nuclear HDAC3 content decreased in the skin tissues of the IMQ group, and RGFP966 further reduced nuclear HDAC3. Compared with the Control and IMQ groups, RGFP966 treatment decreased HDAC3 expression in splenic CD4+ and CD8+ T cells. RGFP966 treatment increased the expression of CCR6 and CCR8 in splenic CD4+ T cells and enhanced IL-17A secretion by peripheral blood and splenic CD4+ T lymphocytes. Additionally, compared with the IMQ group, RGFP966 reduced IL-10 protein levels and upregulated IL-17A expression in skin tissues. ConclusionRGFP966 exacerbates psoriatic-like inflammatory responses by inhibiting HDAC3, increasing the secretion of the cytokine IL-17A, and upregulating the expression of chemokines CCR8 and CCR6.
3.Current Research Status of Digital Technology in the Rehabilitation of Rare Neurological and Muscular Diseases
Yixuan GUO ; Yi GAO ; Yiyang YAO ; Zhuoyue QIN ; Yaofang ZHANG ; Jiaqi JING ; Jing XIE ; Jian GUO ; Shuyang ZHANG
JOURNAL OF RARE DISEASES 2025;4(1):122-131
To review the randomized controlled trials (RCTs) at home and abroad on digital intelligence (DI)-driven rehabilitation in patients of neuromuscular disease, compare the effects of DI-driven rehabilitation with traditional rehabilitation, summarize the special needs and challenges faced by patients in rehabilitation of rare neuromuscular diseases, and provide evidence for the development and quality improvement of rehabilitation for rare neuromuscular diseases. We searched PubMed, Web of Science, Embase, CNKI, VIP, and Wanfang databases for literature on neuromuscular diseases, rare diseases, digital and intelligent technologies, and rehabilitation published from the inception of the databases to June 2024. Basic and research-related information from the retrieved literature was extracted and analyzed. A total of 43 RCTs in English from 14 countries were included. The most studied diseases were Parkinson′s disease and multiple sclerosis. The application of DI-driven technologies in rehabilitation of rare neuromuscular diseases was still limited. The commonly used technologies were virtual reality (VR) games, intelligent treadmill assistance, gait training robots, hybrid assistive limb (HAL), wearable sensors and tele-rehabilitation (TR) systems. These technologies were applied in patients′ homes or rehabilitation service centers. The VR games significantly improved both static/dynamic balance functions and cognitive functions. The intelligent treadmill assistance significantly enhanced gait speed and stride length. The gait training robots significantly improved balance, gait speed and stride length of patients. The wearable exoskeletons significantly enhanced walking ability. DI-driven rehabilitation measures have great value and potential in the field of neuromuscular disease rehabilitation. Their advantages and characteristics can meet the diverse needs of rare disease patients. In the future, a hierarchical and collaborative rehabilitation service system should be established to meet the urgent needs of the rehabilitation of rare neuromuscular diseases. Combining the advantages of digitization and intelligence will provide standardized, scientific, convenient and affordable rehabilitation services to patients.
4.The Application of Digital Intelligence Technology in the Management of Non-Hospitalized Patients with Rare Diseases
Yiyang YAO ; Yi GAO ; Yixuan GUO ; Zhuoyue QIN ; Yaofang ZHANG ; Jiaqi JING ; Jing XIE ; Jian GUO ; Shuyang ZHANG
JOURNAL OF RARE DISEASES 2025;4(1):46-53
To provide references to and give suggestions to the development and optimiza-tion of Digital Intelligence (DI) technology in management of non-hospitalized patients by systematical review the application of digital technology in non-hospital settings. We designed the search strategy and used the words " rare diseases"" patient management"" non-hospitalized management"" community management"" digital intelligence"" big data"" telemedicine" as MESH terms or free words. We searched the database of PubMed, Science-Direct, Web of Science, CNKI, Wanfang and VIP from the beginning of the database to July 2024 and used computer retrieval to get the literatures on the application of DI technology in the management of patients with rare diseases in non-hospital setting. We extracted the information of the first author, country or region, publication time, research participants, DI technology application, and application effect for summary analysis. A total of 13 articles were included in this study, which were from 8 countries or regions. We found that DI technologies used were in the following forms: Internet information platform, wearable devices, telemedicine management platform and electronic database. The DI technology was used by the patients with rare diseases, patient caregivers and professional medical staffs. The application of all the forms above in different populations had good effect. The Internet information platform helped patients and their caregivers learn more about the disease and improved their self-management ability. The wearable device helped monitor the health status of patients in real time and predict the risk of emergent events. The telemedicine management platform facilitated to optimize the allocation of medical resources and strengthen doctor-patient communication. The electronic health database promoted the interconnection of data inside and outside the hospital and improved the accuracy of decision-making through data sharing. The application of DI technology in the management of patients with rare diseases in non-hospitalized settings has shown positive results. In the future, it is necessary to correct the shortcomings and to deal with the challenges in terms of accuracy, readiness, applicability, and privacy protection. Besides, the DI can be integrated into the tri-level management system of patients known as the "patient-community-hospital". It is advisable to take the advantages of digital intelligence technology to improve the efficiency and quality of management of patients in non-hospitalized settings.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Construction of drug utilization evaluation criteria for Dezocine injection based on evidence-based methodology and Delphi method
Yuanyuan GUO ; Chao WANG ; Yinpeng QIN ; Yi ZHANG ; Yishan BU
China Pharmacy 2025;36(15):1841-1845
OBJECTIVE To construct the drug utilization evaluation criteria for Dezocine injection, so as to provide reference for the rational drug use in medical institutions. METHODS On the basis of evidence methodology, relevant guidelines/expert consensus, systematic reviews/meta-analysis were consulted; the evaluation criteria framework for Dezocine injection was established after screening evidence. Delphi method was employed, whereby 28 clinicians and clinical pharmacists from secondary and above-level medical institutions across eight provinces, including Tianjin, Beijing and Shandong, were selected to participate in two rounds of questionnaire surveys. The final indicators were determined based on the experts’ enthusiasm coefficient, authority coefficient, and degree of coordination. RESULTS The effective recovery rate of questionnaire was 100% in the first round and 92.86% in the second round; expert authority coefficient was 0.82 in the first round and 0.81 in the second round; the coordination degree of experts in the first round was 0.29, and in the second round was 0.31 (P<0.001). Drug utilization evaluation standard system for Dezocine injection was formed finally, including three dimensions of medication indications, medication process and medication results, with a total of 11 first-level indicators (such as indications, usage and dosage) and 33 second-level indicators (such as labor analgesia and the management of severe pain following major or moderate surgeries combined with other analgesic drugs). The average importance scores for each indicator ranged from 4.08 to 5.00 points, with an overall average score of 4.61 points and coefficient of variation ranging from 0 to 0.19. CONCLUSIONS The drug utilization evaluation criteria for Dezocine injection established based on evidence-based methodology and Delphi method is authoritative and scientific, which provides a reference for subsequent evaluation of the rationality of clinical medication.

Result Analysis
Print
Save
E-mail