1.Treatment Principles and Paradigm of Diabetic Microvascular Complications Responding Specifically to Traditional Chinese Medicine
Anzhu WANG ; Xing HANG ; Lili ZHANG ; Xiaorong ZHU ; Dantao PENG ; Ying FAN ; Min ZHANG ; Wenliang LYU ; Guoliang ZHANG ; Xiai WU ; Jia MI ; Jiaxing TIAN ; Wei ZHANG ; Han WANG ; Yuan XU ; .LI PINGPING ; Zhenyu WANG ; Ying ZHANG ; Dongmei SUN ; Yi HE ; Mei MO ; Xiaoxiao ZHANG ; Linhua ZHAO
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(5):272-279
To explore the advantages of traditional Chinese medicine (TCM) and integrative TCM-Western medicine approaches in the treatment of diabetic microvascular complications (DMC), refine key pathophysiological insights and treatment principles, and promote academic innovation and strategic research planning in the prevention and treatment of DMC. The 38th session of the Expert Salon on Diseases Responding Specifically to Traditional Chinese Medicine, hosted by the China Association of Chinese Medicine, was held in Beijing, 2024. Experts in TCM, Western medicine, and interdisciplinary fields convened to conduct a systematic discussion on the pathogenesis, diagnostic and treatment challenges, and mechanism research related to DMC, ultimately forming a consensus on key directions. Four major research recommendations were proposed. The first is addressing clinical bottlenecks in the prevention and control of DMC by optimizing TCM-based evidence evaluation systems. The second is refining TCM core pathogenesis across DMC stages and establishing corresponding "disease-pattern-time" framework. The third is innovating mechanism research strategies to facilitate a shift from holistic regulation to targeted intervention in TCM. The fourth is advancing interdisciplinary collaboration to enhance the role of TCM in new drug development, research prioritization, and guideline formulation. TCM and integrative approaches offer distinct advantages in managing DMC. With a focus on the diseases responding specifically to TCM, strengthening evidence-based support and mechanism interpretation and promoting the integration of clinical care and research innovation will provide strong momentum for the modernization of TCM and the advancement of national health strategies.
2.Correlation between Serum Ferritin Levels and the Efficacy of Platelet Transfusion in Patients with Malignant Hematological Diseases
Yi-Yao LI ; Xiao-Yun GAO ; Hang GUAN ; Yu BAI ; Jun-Hui JIA ; Wei BAI ; Yan-Hui DI ; Hua TIAN ; Li-Duo KOU ; Xin-Hua WANG
Journal of Experimental Hematology 2025;33(6):1779-1783
Objective:To explore the correlation between serum ferritin(SF)levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Methods:Patients with malignant hematological diseases who received repeated transfusions of apheresis platelets in Department of Hematology of Aerospace Center Hospital in 2023 were selected.The platelet corrected count increment(CCI)was used to evaluate the efficacy of platelet transfusion.The correlations between sex,age,disease type,transplantation history,red blood cell transfusion history,and SF level and the efficacy of platelet transfusion were analyzed.Results:A total of 87 patients were included,with a cumulative 326 person-times platelet transfusions.As suggested by one-way analysis of variance,compared with the patients in the age groups of 24-45 years old and 46-66 years old,the patients in the age group of 2-23 years old had a better efficacy of platelet transfusion(P=0.004,P=0.004).There was no significant difference in the efficacy of platelet transfusion between the patients in the age group of 24-45 years old and those in the age group of 46-66 years old(P=0.876).Compared with the patients who had a history of red blood cell transfusion within 3 days,the patients without a history of red blood cell transfusion within 3 days had a better efficacy of platelet transfusion(P<0.001).Compared with the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L,the group with SF levels<1.44 ng/L had a better efficacy of platelet transfusion(P=0.028,P<0.001).Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).After adjusting for age and the history of red blood cell transfusion,the transfusion efficacy of the group with SF levels<1.44 ng/L was better than that of the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L(P=0.021,P<0.001);Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).Both univariate and multivariate linear regression models showed that SF levels were negatively correlated with the efficacy of platelet transfusion(P<0.001).Conclusion:There is a negative correlation between SF levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Detection of SF levels may provide guidance for predicting the efficacy of platelet transfusion.
3.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
4.Study on the medication rules of traditional Chinese medicine in treating breast cancer based on data mining
Yuan LI ; Lin QIAN ; Chao TIAN ; Tao WU ; Lyuhui HU ; Bingmei ZHU ; Zhihua YE ; Zhizhen TAO ; Min YANG ; Qinxi LIU ; Bihui YANG ; Hang LUO ; Fan QU ; Yi YANG
China Modern Doctor 2025;63(24):68-72,129
Objective To analyze the medication rules of traditional Chinese medicine in treating breast cancer based on real-world data mining.Methods Inpatients with breast cancer who received traditional Chinese medicine treatment at the Affiliated Hospital of Chengdu University of Traditional Chinese Medicine from January 2017 to December 2021 were selected.Python 3.10 software was used to mine traditional Chinese medicine prescription data;SPSS 23.0 software was applied for descriptive analysis,and systematic cluster analysis was performed on high-frequency drugs.Results A total of 3026 consultation records of inpatients with breast cancer were collected.The main traditional Chinese medicine syndrome diagnosis of"predominantly liver depression and Qi stagnation"accounted for 60.94%of the total consultations.A total of 240 kinds of traditional Chinese medicine were used,with a cumulative frequency of 35 462 times.Among them,29 kinds of traditional Chinese medicine such as Danggui,Fuling,Baizhu,Chaihu had a cumulative usage frequency exceeding 300 times.Regarding the four natures of drugs,cold-natured(43.55%),warm-natured(30.05%),and neutral-natured(23.34%)drugs were predominant;In terms of five flavors,sweet(46.12%),bitter(30.91%),and pungent(20.02%)were the main ones.The most frequently used drugs were tonifying herbs(32.77%),followed by heat-clearing herbs(15.96%)and phlegm-resolving herbs(14.71%).Systematic cluster analysis yielded 7 groups of drug combinations.Conclusion In real-world clinical practice,traditional Chinese medicine for breast cancer mainly uses tonifying herbs,reflecting the traditional Chinese medicine principle of"strengthening healthy Qi and cultivating the root"in treating tumors.The four natures and five flavors of drugs follow syndrome differentiation and the combination of cold and heat.The clustered drug combinations have extensive therapeutic effects,covering various syndromes of breast cancer at different stages,which can provide a reference for clinical medication.
5.Chemical constituents of Stelmatocrypton khasianum and their biological activity
Jing YU ; Guo-xu MA ; Cui-yun YIN ; Zhao-you DENG ; Yi-hang LI ; Er LI
Chinese Traditional Patent Medicine 2025;47(11):3645-3650
AIM To study the chemical constituents from Stelmatocrypton khasianum.(Benth.)Baill.and their in vitro anti-inflammatory activity and cytotoxic activity.METHODS Separation and purification were performed using thin layer chromatography,silica gel,semi-preparative HPLC and Sephadex LH-20,then the structures of obtained compounds were identified by physicochemical properties and spectral data.The in vitro anti-inflammatory activity was evaluated by RAW264.7 model,and the cytotoxic activity was determined by CCK-8 method.RESULTS Fifteen compounds were isolated and identified as 2α,3β,19α,23-tetrahydroxy-urs-12-en-28-oic acid-3-O-β-D-glucopyranosyl-28-O-β-D-glucopyranosyl ester(1),dalzienoside(2),benzyl-(6-O-α-L-rhanmopyranosyl)O-β-D-glucopyranoside(3),corchorusoside C(4),cyclo(Ala-Tyr)(5),thymidine(6),(4S,5S)-5-hydroxy-4-hexanolide(7),2-methylpyridin-3-ol(8),butyl isobutyl phthalate(9),bis-(2-ethylhexyl)terephthalate(10),p-hydroxybenzaldehyde(11),vanilic acid(12),salicylic acid(13),isovanilic acid(14),3-hydroxy-p-anisaldehyde(15).The IC50 values of compounds 1,2 and 4 for NO were(27.69±5.51),(25.82±3.58)and(23.35±7.09)μmol/L,respectively.The IC50 value of compound 1 on MCF-7 cells was(18.15±6.45)μmol/L.The IC50 values of compound 4 on MCF-7 and HCCC-9810 cells were(19.43±2.66)and(21.76±5.81)μmol/L,respectively.CONCLUSION Compounds 2-11 are isolated from S.khasianum for the first time.Compounds 1,2 and 4 exhibit good in vitro anti-inflammatory activity,and 1,4 have cytotoxic activity.
6.Research on low-dose CT image denoising method based on improved Corediff model
Li-mei SONG ; Hang WU ; Yi-feng HUANG ; Qiang WANG ; Guan-jun LIU ; Feng CHEN ; Ming YU ; Jian-kun SHEN
Chinese Medical Equipment Journal 2025;46(5):9-13
Objective To propose a low-dose CT image denoising method based on an improved Corediff model to recover the detailed features of the image and enhance the image quality.Methods An RS-Corediff model was established by modifying the key component U-Net network of the Corediff model.Firstly,the residual module was introduced in the network input stage for feature extraction;secondly,a new downsampling module was designed in the U-Net network encoder,which learned the semantic information of the feature map by convolution and maintained the learning state during the downsampling process so as to fully extract the image features;thirdly,the feature splicing processing was used to further enhance the learning effect during the upsampling process of the U-Net network decoder;finally,the convolutional kernel size was modified to adjust the sensory field during the convolutional process of the whole U-Net network structure so as to obtain rich features.The RS-Corediff model was compared with the residual encoder-decoder convolutional neural network(RED-CNN)model and the Corediff model on the public dataset AAPM 2016 in order to verify its effectiveness for low-dose CT image denoising.Results The RS-Corediff model gained advantages over the RED-CNN and Corediff models with a peak signal-to-noise ratio(PSNR)of 41.269 8,structural similarity(SSIM)of 0.953 4 and root mean square error(RMSE)of 17.568 7.Conclusion The proposed method effectively preserves the texture and details of low-dose CT images during the denoising process to improve the overall quality of the images.[Chinese Medical Equipment Journal,2025,46(5):9-13]
7.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
8.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
9.Development of a diagnostic model for severe coronary artery stenosis using resting echocardiography
Qingyu ZHONG ; Luwei YE ; Lan SHANG ; Sijia WANG ; Hang WU ; Zhenni ZHANG ; Qingguo MENG ; Chunmei LI ; Yan DENG ; Lixue YIN ; Yi WANG
Chinese Journal of Ultrasonography 2025;34(11):958-966
Objective:To evaluate the diagnostic performance of resting echocardiography in detecting severe coronary artery stenosis.Methods:A total of 136 patients with suspected coronary artery disease(CAD)who presented to Sichuan Provincial People's Hospital between January 2021 and December 2024 were prospectively enrolled. All patients underwent both coronary computed tomography angiography(CCTA)and transthoracic echocardiography within one week. Based on CCTA results,the patients were divided into non-severe stenosis group( n=78)and severe stenosis group( n=58). Echocardiographic parameters including left atrial maximum volume(LAVmax),left ventricular global longitudinal strain(GLS),left ventricular longitudinal strain of endo-myocardium,mid-myocardium,epi-myocardium(LSendo,LSmid,LSepi),early diastolic mitral inflow velocity(E),early diastolic mitral annular velocity of the lateral and septal walls(e'),and E/e' were measured. Predictive factors for severe coronary stenosis were identified using LASSO regression,and a nomogram model was developed via multivariate Logistic regression. Model performance was evaluated using ROC curves,calibration curves,and decision curve analysis. Results:Multivariate Logistic regression analysis revealed LSendo,LAVmax,and E/e' as independent predictors of severe coronary artery stenosis. The nomogram constructed based on these predictors achieved an area under the curve of 0.798(95% CI=0.723-0.873),with sensitivity and specificity of 0.756 and 0.759,respectively. Conclusions:The resting echocardiography-based nomogram model demonstrates good diagnostic efficacy for severe coronary artery stenosis. It may serve as a noninvasive tool to assist in risk stratification and clinical decision-making in patients with suspected CAD.
10.Simultaneous Determination of 50 Kinds of Steroid Hormones in Surface Water by Online Solid Phase Extraction Coupled with Ultra Performance Liquid Chromatography-Triple Quadrupole Mass Spectrometry
Fang-Xi XU ; He NIU ; Yu-Tao GE ; Guo-Hua ZHU ; Hang-Bin LYU ; Jin-Song LI ; Lang-Sha YI ; Jian-Jie FU ; Gui-Bin JIANG
Chinese Journal of Analytical Chemistry 2025;53(6):998-1009,中插22-中插41
A novel analytical method was developed in this study by combining online solid phase extraction with ultra performance liquid chromatography-tandem mass spectrometry(Online SPE-UPLC-MS/MS)for simultaneous determination of 50 kinds of steroid hormones in surface water.Specifically,after high-speed centrifugation of 4 mL water samples,the supernatant was directly injected into an Oasis HLB online SPE column for enrichment and purification.Subsequently,the target compounds were transferred to the analytical column via valve switching for separation and analysis.The chromatographic separation was performed on a Thermo Acclaim RSLC C18 column(100 mm×2.1 mm,2.2 μm),using a mobile phase composed of 5 mmol/L ammonium fluoride aqueous solution and acetonitrile.Mass spectrometric detection was conducted in positive ion mode,utilizing multiple reaction monitoring(MRM)with quantification achieved by the internal standard method.The method validation demonstrated that the limits of detection(LOD)for the 50 kinds of steroid hormones ranged from 0.02 to 0.50 ng/L,while the limits of quantification(LOQ)were between 0.08 and 1.67 ng/L.The average recoveries in surface water samples at spiked concentrations of 5,20 and 200 ng/L were between 74.1%and 119%,with relative standard deviations(RSDs)of 0.2%to 9.9%.This method was applied to analyze 11 surface water samples collected from sites surrounding a pharmaceutical and chemical industrial park.A total of 44 kinds of steroid hormones were detected,with concentrations ranging from 0.11 to 88.6 ng/L,revealing the presence of hormone contamination in the environmental waters surrounding industrial areas.Compared with the traditional offline SPE methods,the proposed online SPE technique significantly reduced sample volume requirements and pretreatment time,while minimizing the loss of target compounds during the pretreatment process.Moreover,compared to reported online SPE techniques,this method achieved high-throughput analysis of multiple classes of steroid hormones,with lower detection limits and higher recoveries.Overall,this method provided rapid sample preparation,high sensitivity,and excellent stability,making it suitable for the direct analysis of trace steroid hormones in surface water.

Result Analysis
Print
Save
E-mail