1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Phase changes and quantity-quality transfer of raw material, calcined decoction pieces, and standard decoction of Ostreae Concha (Ostrea rivularis).
Hong-Yi ZHANG ; Jing-Wei ZHOU ; Jia-Wen LIU ; Wen-Bo FEI ; Shi-Ru HUANG ; Yu-Mei CHEN ; Chong-Yang LI ; Fei-Fei LI ; Qiao-Ling MA ; Fu WANG ; Yuan HU ; You-Ping LIU ; Shi-Lin CHEN ; Lin CHEN ; Hong-Ping CHEN
China Journal of Chinese Materia Medica 2025;50(5):1209-1223
The phase changes and quantity-quality transfer of 17 batches of Ostreae Concha(Ostrea rivularis) during the raw material-calcined decoction pieces-standard decoction process were analyzed. The content of calcium carbonate(CaCO_3), the main component, was determined by chemical titration, and the extract yield and transfer rate were calculated. The CaCO_3 content in the raw material, calcined decoction pieces, and standard decoction was 94.39%-98.80%, 95.03%-99.22%, and 84.58%-90.47%, respectively. The process of raw material to calcined decoction pieces showed the yield range of 96.85% to 98.55% and the CaCO_3 transfer rate range of 96.92% to 99.27%. The process of calcined decoction pieces to standard decoction showed the extract yield range of 2.86% to 5.48% and the CaCO_3 transfer rate range of 2.59% to 5.13%. The results of X-ray fluorescence(XRF) assay showed that the raw material, calcined decoction pieces, and standard decoction mainly contained Ca, Na, Mg, Si, Br, Cl, Al, Fe, Cr, Mn, and K. The chemometric results showed an increase in the relative content of Cr, Fe, and Si from raw material to calcined decoction pieces and an increase in the relative content of Mg, Al, Br, K, Cl, and Na from calcined decoction pieces to standard decoction. X-ray diffraction(XRD) was employed to establish XRD characteristic patterns of the raw material, calcined decoction pieces, and standard decoction. The XRD results showed that the main phase of all three was calcite, and no transformation of crystalline form or generation of new phase was observed. Fourier transform infrared spectroscopy(FTIR) was employed to establish the FTIR characteristic spectra of the raw material, calcined decoction pieces, and standard decoction. The FTIR results showed that the raw material had internal vibrations of O-H, C-H, C=O, C-O, and CO■ groups. Due to the loss of organic matter components after calcination, no information about the vibrations of C-H, C=O, and C-O groups was observed in the spectra of calcined decoction pieces and standard decoction. In summary, this study elucidated the quantity-quality transfer and phase changes in the raw material-calcined decoction pieces-standard decoction process by determining the CaCO_3 content, calculating the extract yield and transfer rate, and comparing the element changes, FTIR characteristic spectra, and XRD characteristic pattern. The results were reasonable and reliable, laying a foundation for the subsequent process research and quality control of the formula granules of calcined Ostreae Concha(O. rivularis Gould), and providing ideas and methods for the quality control of the whole process of raw material-decoction pieces-standard decoction-formula granules of Ostreae Concha and other testacean traditional Chinese medicine.
Drugs, Chinese Herbal/isolation & purification*
;
Calcium Carbonate/analysis*
;
Quality Control
7.Risk factors for cardiopulmonary dysfunction after ligation of hemodynamically significant patent ductus arteriosus in preterm infants.
Chong-Chong LIU ; Yong LIU ; Yi ZHANG ; Dai-Cheng HAN ; Rui-Jing HE ; Shi-Wen XIA
Chinese Journal of Contemporary Pediatrics 2025;27(4):425-431
OBJECTIVES:
To investigate the risk factors for the occurrence of cardiopulmonary dysfunction following ligation of hemodynamically significant patent ductus arteriosus (hsPDA) in preterm infants.
METHODS:
A retrospective collection of clinical data was conducted on preterm infants with a gestational age of <34 weeks who were admitted to the Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technology from January 2018 to August 2024. These infants underwent hsPDA ligation after 1-2 courses of failed ibuprofen treatment. Based on the occurrence of blood pressure changes and oxygenation or ventilation failure postoperatively, the infants were divided into a cardiopulmonary dysfunction group (19 cases) and a non-cardiopulmonary dysfunction group (40 cases). Binary logistic regression analysis was performed to explore risk factors for postoperative cardiopulmonary dysfunction.
RESULTS:
Binary logistic regression analysis indicated that a faster average weight gain rate preoperatively and low levels of free triiodothyronine (FT3) within one week before surgery were risk factors for cardiopulmonary dysfunction following hsPDA ligation (P<0.05). Receiver operating characteristic curve analysis showed that an average weight gain rate >11.45 g/(kg·d) and FT3 levels <2.785 pmol/L within one week before surgery had predictive value for postoperative cardiopulmonary dysfunction (P<0.05). The combination of these two indicators provided the highest predictive value (P<0.05), with an area under the curve of 0.825, a sensitivity of 79%, and a specificity of 75%.
CONCLUSIONS
An average weight gain rate exceeding 11.45 g/(kg·d) and FT3 levels below 2.785 pmol/L within one week before surgery are risk factors affecting cardiopulmonary function after hsPDA ligation. Preoperative assessment and intervention should be strengthened to reduce the risk of postoperative complications.
Humans
;
Ductus Arteriosus, Patent/physiopathology*
;
Risk Factors
;
Female
;
Infant, Newborn
;
Male
;
Retrospective Studies
;
Infant, Premature
;
Ligation/adverse effects*
;
Hemodynamics
;
Postoperative Complications/etiology*
;
Logistic Models
;
Lung Diseases/etiology*
8.Influence of exercise rehabilitation based on psycho-cardiology medical model on patients with coro-nary heart disease after PCI
He-Lin ZHANG ; Yi-Chun ZHANG ; Chong-Huai GU ; Zhi-Xiang PENG
Chinese Journal of cardiovascular Rehabilitation Medicine 2024;33(1):20-25
Objective:To study influence of exercise rehabilitation based on psycho-cardiology medical model on pa-tients with coronary heart disease(CHD)after percutaneous coronary intervention(PCI).Methods:A total of 164 CHD patients undergoing PCI in our hospital were randomly and equally divided into routine nursing group and exer-cise rehabilitation group(received exercise rehabilitation based on psycho-cardiology medical model based on rou-tine nursing group).Both groups were intervened for six months.General clinical data,score of somatic symptoms scale(SSS),cardiac function indexes:LVEF and LVEDV,6min walking distance(6MWD)and score of 36-item short-form heath survey(SF-36)were compared between two groups.Results:During follow-up,there were three cases lost in routine nursing group,and two cases lost and four cases stopped follow-up in exercise rehabilita-tion group.Compared with routine nursing group,six months after intervention,there were significant reductions in SSS score[(33.97±5.76)scores vs.(25.76±4.79)scores]and LVEDV[(125.33±16.14)ml vs.(119.53± 16.82)ml],and significant rise in LVEF[(56.28±4.46)%vs.(59.28±4.90)%],6MWD[(410.42±20.08)m vs.(439.69±20.66)m],scores of physical functioning[(19.20±4.22)scores vs.(23.76±3.98)scores],bodily pain[(7.42±1.99)scores vs.(8.84±1.94)scores],general health[(16.42±4.73)scores vs.(19.09±4.37)scores],vitality[16.0(7.0)scores vs.19.0(6.8)scores],role-emotional[(4.86±1.10)scores vs.(5.18± 0.86)scores],mental health[20.0(5.0)scores vs.24.0(8.8)scores]of SF-36 in exercise rehabilitation group(P<0.05 or<0.01).Conclusion:Exercise rehabilitation based on psycho-cardiology medical model can signifi-cantly improve cardiac function and psychological status,and improve quality of life in patients with coronary heart disease after PCI.
9.Risk factors for bronchopulmonary dysplasia in preterm infants and establishment of a prediction model
Yi-Bo LIU ; Chong-Bing YAN ; Yuan-Yang ZHANG ; Bo-Wen WENG ; Cheng CAI
Chinese Journal of Contemporary Pediatrics 2024;26(11):1148-1154
Objective To investigate the risk factors for bronchopulmonary dysplasia (BPD) in preterm infants,and to establish a risk prediction model. Methods A total of 120 preterm infants who were admitted to the neonatal intensive care unit of Shanghai Children's Hospital from January to December 2022 were included. According to the diagnostic criteria for BPD released by the National Institute of Child Health and Human Development in 2018,they were divided into a non-BPD group (84 infants) and a BPD group (36 infants). The clinical data of the infants and their mothers were compared between the two groups. The univariate analysis and the stepwise multivariate regression analysis were used to identify the risk factors for BPD and establish a risk prediction model. Results The results showed that a gestational age of<28 weeks,duration of noninvasive respiratory support,comorbidity with infectious pneumonia,and chorioamnionitis in the mother were independent risk factors for BPD in preterm infants (P<0.05). A nomogram model for predicting the development of BPD was established based on the risk factors,with an area under the receiver operating characteristic curve of 0.93,and the calibration curve of this nomogram had a slope of about 1. The goodness-of-fit test indicated the model fitted well (x2=8.287,P=0.406). Conclusions A gestational age of<28 weeks,duration of noninvasive respiratory support,comorbidity with infectious pneumonia,and chorioamnionitis in the mother are independent risk factors for BPD in preterm infants.
10.Early gait analysis after total knee arthroplasty based on artificial intelligence dynamic image recognition
Ming ZHANG ; Ya-Nan SUI ; Cheng WANG ; Hao-Chong ZHANG ; Zhi-Wei CAI ; Quan-Lei ZHANG ; Yu ZHANG ; Tian-Tian XIA ; Xiao-Ran ZU ; Yi-Jian HUANG ; Cong-Shu HUANG ; Xiang LI
China Journal of Orthopaedics and Traumatology 2024;37(9):855-861
Objective To explore early postoperative gait characteristics and clinical outcomes after total knee arthroplasty(TKA).Methods From February 2023 to July 2023,26 patients with unilateral knee osteoarthritis(KOA)were treated with TKA,including 4 males and 22 females,aged from 57 to 85 years old with an average of(67.58±6.49)years old;body mass in-dex(BMI)ranged from 18.83 to 38.28 kg·m-2 with an average of(26.43±4.15)kg·m-2;14 patients on the left side,12 pa-tients on the right side;according to Kellgren-Lawrence(K-L)classification,6 patients with grade Ⅲ and 20 patients with grade Ⅳ;the courses of disease ranged from 1 to 14 years with an average of(5.54±3.29)years.Images and videos of standing up and walking,walking side shot,squatting and supine kneeling were taken with smart phones before operation and 6 weeks after operation.The human posture estimation framework OpenPose were used to analyze stride frequency,step length,step length,step speed,active knee knee bending angle,stride length,double support phase time,as well as maximum hip flexion angle and maximum knee bending angle on squatting position.Western Ontario and McMaster Universities(WOMAC)arthritis index and Knee Society Score(KSS)were used to evaluate clinical efficacy of knee joint.Results All patients were followed up for 5 to 7 weeks with an average of(6.00±0.57)weeks.The total score of WOMAC decreased from(64.85±11.54)before op-eration to(45.81±7.91)at 6 weeks after operation(P<0.001).The total KSS was increased from(101.19±9.58)before opera-tion to(125.50±10.32)at 6 weeks after operation(P<0.001).The gait speed,stride frequency and stride length of the affected side before operation were(0.32±0.10)m·s-1,(96.35±24.18)steps·min-1,(0.72±0.14)m,respectively;and increased to(0.48±0.11)m·s 1,(104.20±22.53)steps·min-1,(0.79±0.10)m at 6 weeks after operation(P<0.05).The lower limb support time and active knee bending angle decreased from(0.31±0.38)sand(125.21±11.64)° before operation to(0.11±0.04)s and(120.01±13.35)° at 6 weeks after operation(P<0.05).Eleven patients could able to complete squat before operation,13 patients could able to complete at 6 weeks after operation,and 9 patients could able to complete both before operation and 6 weeks after operation.In 9 patients,the maximum bending angle of crouching position was increased from 76.29° to 124.11° before operation to 91.35° to 134.12° at 6 weeks after operation,and the maximum bending angle of hip was increased from 103.70° to 147.25° before operation to 118.61° to 149.48° at 6 weeks after operation.Conclusion Gait analysis technology based on artificial intelligence image recognition is a safe and effective method to quantitatively identify the changes of pa-tients'gait.Knee pain of KOA was relieved and the function was improved,the supporting ability of the affected limb was im-proved after TKA,and the patient's stride frequency,stride length and stride speed were improved,and the overall movement rhythm of both lower limbs are more coordinated.

Result Analysis
Print
Save
E-mail