1.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
2.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
3.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
4.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
5.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
6.Expert consensus on digital intraoral scanning technology
Jie YOU ; Wenjuan YAN ; Liting LIN ; Wen-Zhen GU ; Yarong HOU ; Wei XIAO ; Hui YAO ; Yaner LI ; Lihui MA ; Ruini ZHAO ; Junqi QIU ; Jianzhang LIU ; Yi ZHOU
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(8):569-577
Digital intraoral scanning is a hot topic in the field of oral digital technology.In recent years,digital intra-oral scanning has gradually become the mainstream technology in orthodontics,prosthodontics,and implant dentistry.The precision of digital intraoral scanning and the accuracy and stitching of data collection are the keys to the success of the impression.However,the operators are less familiar with the intraoral scanning characteristics,imaging process-ing,operator scanning method,oral tissue specificity of the scanned object,and restoration design.Thus far,no unified standard and consensus on digital intraoral scanning technology has been achieved at home or abroad.To deal with the problems encountered in oral scanning and improve the quality of digital scanning,we collected common expert opin-ions and sought to expound the causes of scanning errors and countermeasures by summarizing the existing evidence.We also describe the scanning strategies under different oral impression requirements.The expert consensus is that due to various factors affecting the accuracy of digital intraoral scanning and the reproducibility of scanned images,adopting the correct scanning trajectory can shorten clinical operation time and improve scanning accuracy.The scanning trajec-tories mainly include the E-shaped,segmented,and S-shaped methods.When performing fixed denture restoration,it is recommended to first scan the abutment and adjacent teeth.When performing fixed denture restoration,it is recommend-ed to scan the abutment and adjacent teeth first.Then the cavity in the abutment area is excavated.Lastly,the cavity gap was scanned after completing the abutment preparation.This method not only meets clinical needs but also achieves the most reliable accuracy.When performing full denture restoration in edentulous jaws,setting markers on the mucosal tissue at the bottom of the alveolar ridge,simultaneously capturing images of the vestibular area,using different types of scanning paths such as Z-shaped,S-shaped,buccal-palatal and palatal-buccal pathways,segmented scanning of dental arches,and other strategies can reduce scanning errors and improve image stitching and overlap.For implant restora-tion,when a single crown restoration is supported by implants and a small span upper structure restoration,it is recom-mended to first pre-scan the required dental arch.Then the cavity in the abutment area is excavated.Lastly,scanning the cavity gap after installing the implant scanning rod.When repairing a bone level implant crown,an improved indi-rect scanning method can be used.The scanning process includes three steps:First,the temporary restoration,adjacent teeth,and gingival tissue in the mouth are scanned;second,the entire dental arch is scanned after installing a standard scanning rod on the implant;and third,the temporary restoration outside the mouth is scanned to obtain the three-di-mensional shape of the gingival contour of the implant neck,thereby increasing the stability of soft tissue scanning around the implant and improving scanning restoration.For dental implant fixed bridge repair with missing teeth,the mobility of the mucosa increases the difficulty of scanning,making it difficult for scanners to distinguish scanning rods of the same shape and size,which can easily cause image stacking errors.Higher accuracy of digital implant impres-sions can be achieved by changing the geometric shape of the scanning rods to change the optical curvature radius.The consensus confirms that as the range of scanned dental arches and the number of data concatenations increases,the scanning accuracy decreases accordingly,especially when performing full mouth implant restoration impressions.The difficulty of image stitching processing can easily be increased by the presence of unstable and uneven mucosal mor-phology inside the mouth and the lack of relatively obvious and fixed reference objects,which results in insufficient ac-curacy.When designing restorations of this type,it is advisable to carefully choose digital intraoral scanning methods to obtain model data.It is not recommended to use digital impressions when there are more than five missing teeth.
7.Effects of panatinib regulation of miR-92b-3p on malignant biological behavior of cholangiocarcinoma
Shi QIU ; Jie DU ; Gang LUO ; Yi-Huang LIN ; Zi-Qiang ZHANG ; Fan JIANG
The Chinese Journal of Clinical Pharmacology 2024;40(19):2847-2852
Objective To study the effect of panatinib on cholangiocarcinoma(CCA)and its molecular mechanism.Methods QBC939 cells were divided into control group(no treatment),low dose group(0.1 μmol·L-1 panatinib treatment),medium dose group(0.5μmol·L-1panatinib treatment),high dose group(1.0 μmol·L-1 panatinib treatment)and high dose+microRNA-92b-3 group(after treatment with 1.0 μmol·L-1 panatinib transfected miR-92b-3p mimic),high-dose+miR-92b-3p mimic+overexpressed homologous domain interacting protein kinase 3 plasmid(oe-HIPK3)group(after treatment with 1.0 μmol·L-1 panatinib,miR-92b-3p mimic and oe-HIPK3),mimic-NC group(transfected miR-92b-3p NC),and miR-92b-3p mimic group(transfected miR-92b-3p mimic)were transfected.Cell proliferation was detected by cell counting kit 8(CCK-8);cell migration was detected by Transwell,the relative expression level of protein was detected by Western blot.Results Cell proliferation rates of control group,high-dose group,high-dose+miR-92b-3p mimic group,and high-dose+miR-92b-3p mimic group mimic+oe-HIPK3 group were(76.58±8.56)%,(61.85±7.77)%,(74.54±7.68)%and(58.63±6.87)%,respectively;the number of cells migrated were 185.32±20.14,132.33±18.99,168.23±19.85 and 138.66±15.95,respectively;phosphorylated phosphatidyl inositide 3-kinase(p-PI3K)/PI3K ratios were 1.00±0.23,0.68±0.09,0.91±0.18 and 0.60±0.08,respectively;phosphorylated protein kinase B(p-AKT)/AKT ratios were 1.00±0.25,0.61±0.08,1.12±0.28 and 0.72±0.14,respectively.The above indexes were compared with those of the control group in the high-dose group,and those of the high-dose+miR-92b-3p mimic group in the high-dose+miR-92b-3p mimic group in the oe-HIPK3 group.There were statistically significant differences(all P<0.05).Conclusion Panatinib can effectively inhibit the evil biological behavior of cholangiocarcinoma,which may be related to inhibiting the level of miR-92b-3p and promoting HIPK3-mediated PI3K/AKT signaling pathway.
8.Effect of urine mixing degree on 24-hour urinary total protein in patients with chronic kidney disease based on generalized estimating equation
Shanfang QIU ; Weiwei WU ; Yang LI ; Yi FANG ; Xiaoyan JIAO ; Wenqi SHAO ; Shuan ZHAO ; Jie TENG ; Jieru CAI ; Xiaoqiang DING
Chinese Journal of Clinical Medicine 2024;31(3):428-432
Objective To explore the effect of urine mixing degree on 24-hour urinary total protein(24 h UTP)in patients with chronic kidney disease(CKD).Methods From October 1,2023 to December 31,2023,30 hospitalized patients who needed to complete 24 h UTP testing in Zhongshan Hospital,Fudan University were selected.A 5 L unified container was used to collect urine for 24 hours.After collection and one hour's standing,the urine sample was divided into upper,middle,and lower equal parts according to volume,which was defined as direct-sampling group.Then,the urine samples were fully mixed with a magnetic stirrer and sampled again according to the above-mentioned three-equal sampling method,which was defined as mixed-sampling group.The generalized estimating equation was used to compare the urinary protein concentration before and after mixing and at different sampling location.Results The results of generalized estimating equation showed that after controlling the variable"sampling position",there was no significant difference in urinary protein concentration between the direct-sampling group and the mixed-sampling group.After controlling the variable"mixing method",there was still no significant difference in urinary protein concentration at different sampling positions.After adjusting the covariates such as age,gender,and estimated glomerular filtration rate(eGFR),the results were consistent.Conclusions With standard protocol,the entire 24-hour urine sample is a relatively even-distributed solution.After the total urine collection is completed,the temporary sample can be directly extracted from any level of the original urine within 1 hour,and the urine protein concentration of the sample multiplied by the urine volume can reflect the 24 h UTR.
9.Insight of N-Lauroyl-L-alanine Molecular Assembly Using Solid-State Nuclear Magnetic Resonance Technique
Zi-Hui QIU ; Ling-Yun XU ; Yi-Jian CHEN ; Hong-Chun DONG ; Jie SHU ; Zhi-Gang YAO
Chinese Journal of Analytical Chemistry 2024;52(6):866-875
Amino acid surfactants (AAS) have excellent properties such as low toxicity,antibacterial,mildness,and corrosion resistance. In recent years,they have been widely applied in the field of daily chemicals,food and pharmaceutical industry. It is pointed out that the structure at molecular level largely affects the physical and chemical properties of AAS materials. In this work,the structures of solid-state N-lauroyl-L-alanine (NLLA) including intermolecular interactions,molecular local dynamics and molecular assembly were investigated by a variety of solid-state nuclear magnetic resonance (SSNMR) techniques. Based on 2D 1H-1H double quantum-single quantum (2D 1H-1H DQ-SQ),1H-1H DQ sideband pattern and molecular simulation,it was found that there was a stable intermolecular hydrogen bond formed between the carboxyl units of two NLLA molecules. Combined with the study of 2D frequency switched Lee—Goldberg heteronuclear correlation (2D 13C-1H FSLG-HETCOR) and 13C T1,another type of hydrogen bond was probed,which existed between amide units of neighboring molecules. In addition,the conformation of alkyl chain ends was investigated. According to 1D 13C{1H}cross polarization/magic angle spinning (CP/MAS) and 2D 13C-1H FSLG-HETCOR spectra,it was revealed that the alkyl-chain ends had both gauche and trans conformations. Moreover,the trans conformation showed two distinct 13C chemical shifts,originated from two NLLA molecular assembly forms. Accordingly,two NLLA molecular assembly structures were suggested which were transoid form and cisoid form. This work provided a SSNMR investigation strategy for characterizing the molecular local structure and dynamics of AAS materials,which helped task of researching and developing materials with improved chemical and physical properties.
10.Development and validity test of alcohol-related cognitive scale among adolescents based on health belief model
Xiao-Tao YAN ; Wen-Jie GUO ; Cai-Fang SHEN ; Zi-Yi CUI ; Jia-Qian WU ; Ling FANG ; Yu-Chen ZHAO ; Chen-Yu QIAN ; Yan-Qiu YU ; Pin-Pin ZHENG
Fudan University Journal of Medical Sciences 2024;51(4):465-472
Objective To develop a health belief model(HBM)based adolescent alcohol-related cognition scale to measure adolescent alcohol-related cognition and test its reliability and validity.Methods The adolescents'alcohol-related cognitive scale was developed based on HBM model.By using purposive sampling,three general high schools in Qingpu District,Shanghai were selected.One-third of the classes from grades 10 and 11 in each school were randomly selected,and the students from these classes were surveyed as the research subjects.Exploratory factor analysis and confirmatory factor analysis were used to analyze its reliability(internal consistency reliability and combination reliability)and validity(structural validity,convergent validity,discriminative validity and criterion validity).Results A total of 970 questionnaires were collected,of which 948 were valid,with an effective rate of 97.7%.The adolescents'alcohol-related cognitive scale contained 22 items.Five common factors were extracted from exploratory factor analysis,including perceived susceptibility,perceived severity,perceived benefits,perceived obstacles,and self-efficacy.The cumulative variance contribution rate reached 83.89%.The results of confirmatory factor analysis confirmed the overall fit of the model.The average variance extracted value(AVE)of each dimension was greater than 0.5,and the convergent validity of the model was ideal.The AVE square root of each dimension of the scale was greater than its correlation coefficient,indicating good discrimination validity.Cronbach's α coefficient of the total volume table was 0.892,indicating good overall reliability.Conclusion The adolescents'alcohol-related cognitive scale developed in this study has good reliability and validity,which can be used to measure adolescents'alcohol-related perceptions.


Result Analysis
Print
Save
E-mail