1.Application of middle hepatic vein splitting and reconstruction technique in split liver transplantation from low-age donor livers
Hui TANG ; Binsheng FU ; Qing YANG ; Jia YAO ; Kaining ZENG ; Xiao FENG ; Shuhong YI ; Yang YANG
Organ Transplantation 2025;16(3):453-459
Objective To explore the feasibility and clinical experience of the middle hepatic vein splitting-reconstruction technique in split liver transplantation from low-age donor livers. Methods A retrospective analysis was conducted on the cases of two low-age donor livers that underwent middle hepatic vein splitting-reconstruction, which were transplanted into four child recipients at the Liver Transplantation Center of the Third Affiliated Hospital of Sun Yat-sen University from January 2017 to July 2023. The surgical and postoperative conditions were summarized and analyzed. Results Donor 1 was a 6-year-old and 4-month-old girl with a body weight of 21 kg, and the obtained donor liver weighed 496 g. After splitting, the left and right liver weights were 201 g and 280 g, and transplanted into a 9-month-old boy weighing 6.5 kg and a 9-month-old boy weighing 7.5 kg, respectively. The graft to recipient weight ratio (GRWR) was 3.09% and 3.73%, respectively. Donor 2 was a 5-year-old and 8-month-old boy with a body weight of 19 kg, and the donor liver weighed 673 g. After splitting, the left and right liver weights were 230 g and 400 g, and transplanted into a 13-month-old girl weighing 9.5 kg and a 15-month-old boy weighing 12 kg. The GRWR was 2.42% and 3.33%, respectively. Both donor livers were split ex vivo, with the middle hepatic vein being completely split in the middle and reconstructed using allogeneic iliac vein and iliac artery vascular patches. According to GRWR, none of the 4 transplant livers were reduced in volume. Among the 4 recipients, one died due to postoperative portal vein thrombosis and non-function of the transplant liver, while the other three cases recovered smoothly without early or late complications. Regular follow-up was conducted until July 31, 2023, and liver function recovered well. Conclusions Under the premise of detailed assessment of the donor liver and meticulous intraoperative operation, as well as matching with suitable child recipients, low-age donor livers may be selected for splitting. The complete splitting and reconstruction of the middle hepatic vein in the middle may effectively ensure the adequate venous return of the left and right liver and provide sufficient functional liver volume.
2.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
3.Concept, design and clinical application of minimally invasive liver transplantation through laparoscopic combined upper midline incision
Shuhong YI ; Hui TANG ; Kaining ZENG ; Xiao FENG ; Binsheng FU ; Qing YANG ; Jia YAO ; Yang YANG ; Guihua CHEN
Organ Transplantation 2025;16(1):67-73
Objective To explore the technical process and clinical application of laparoscopic combined upper midline incision minimally invasive liver transplantation. Methods A retrospective analysis was conducted on 30 cases of laparoscopic combined upper midline incision minimally invasive liver transplantation. The cases were divided into cirrhosis group (15 cases) and liver failure group (15 cases) based on the primary disease. The surgical and postoperative conditions of the two groups were compared. Results All patients successfully underwent laparoscopic "clockwise" liver resection, with no cases of passive conversion to open surgery or intolerance to pneumoperitoneum. In 6 cases, the right lobe was relatively large, and the right hepatic ligaments could not be completely mobilized. One case required an additional reverse "L" incision during open surgery. All patients successfully completed the liver transplantation, with no major intraoperative bleeding, cardiovascular events, or other occurrences in the 30 patients. The model for end-stage liver disease (MELD) score in the cirrhosis group was lower than that in the liver failure group (P<0.001). There were no statistically significant differences between the two groups in terms of age, surgical time, blood loss, anhepatic phase, or cold ischemia time (all P>0.05). During the perioperative period, there was 1 case of hepatic artery embolism, 1 case of portal vein anastomotic stenosis, no complications of hepatic vein and inferior vena cava, and 3 cases of biliary anastomotic stenosis, all of which occurred in the liver failure group. Conclusions In strictly selected cases, the minimally invasive liver transplantation technique combining laparoscopic hepatectomy with upper midline incision for graft implantation has the advantages of smaller incisions, less bleeding, relatively easier operation, and faster postoperative recovery, which is worthy of clinical promotion and application.
4.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
5.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
6.Feasibility Analysis of Establishing Combat Readiness Blood Bank Based on Low Titer Group O Whole Blood and Group A Plasma
Yuan-Yuan LUO ; Chun-Ya MA ; Li LIU ; Li-Hui FU ; Meng YI ; Yang YU
Journal of Experimental Hematology 2024;32(2):541-545
Objective:To explore the feasibility of establishing combat readiness blood bank with low titer group O whole blood and group A plasma.Methods:The Galileo automatic blood analyzer was used to detect the titers of IgM anti-A and anti-B antibodies in the samples of group O blood donors and IgM anti-B titer in the samples of group A blood donors.Group O blood donors with antibody titers below 128 were selected and included in the mobile blood bank for combat readiness,group A plasma with anti-B titer lower than 128 and group O whole blood with antibody titers below 128 were included in the combat readiness entity blood bank.Results:A total of 1 452 group O blood donors were selected,and the anti-A/B antibody titers were detected.Both antibody titers were distributed below 512,and both peak values of sample distribution were at titer 4.The proportion of samples with titers>128 for both antibodies was relatively low.There was a significant positive correlation between the titers of the two antibodies(r=0.383),and the proportion of samples with IgM anti-A titer higher than IgM anti-B titer was relatively high.1 335(91.94%)group O blood donors with IgM anti-A and anti-B antibody titers<128 could be included in the mobile blood bank.The anti-B titer of group A blood was detected in 512 cases and the results showed that as the antibody titer increased,the proportion of blood donors gradually decreased.99.8%of group A blood donors had anti-B antibody titer less than 128,and only one case did not meet the inclusion criteria.Conclusion:The proportion of group O blood donors whose whole blood meet the low antibody titer standard is high,and almost all plasma of group A blood donors meet the low titer standard,which improves the blood supply rate in emergencies.
7.The safety and short-term efficacy of yttrium-90 resin microspheres transarterial radioembo-lization for the treatment of initial unresectable malignant hepatic tumor
Minghua SHAO ; Binbin TAN ; Ying FU ; Zhiyu CHEN ; Yi GONG ; Haisu DAI ; Hailei CHEN ; Hui ZHANG
Chinese Journal of Digestive Surgery 2024;23(7):969-975
Objective:To investigate the safety and short-term efficacy of yttrium-90 [ 90Y] resin microspheres transarterial radioembolization (TARE) for the treatment of initial unresectable malignant hepatic tumor. Methods:The retrospective and descriptive study was conducted. The clinicopathological data of 10 patients with initial unresectable malignant hepatic tumor who were admitted to The First Affiliated Hospital of Army Medical University from June 2022 to June 2023 were collected. All patients were males, aged (57±4)years. Measurement data with normal distribution were represented as Mean± SD, and comparison before and after treatment within the group was conducted using the paired t test. Measurement data with skewed distribution were represented as M( Q1, Q3) or M(range), and comparison before and after treatment within the group was conducted using the paired rank sum test. Count data were described as absolute numbers or proportions. Results:(1) Pre-treatment assessment. All 10 patients completed pre-treatment assessment, with 8 cases undergoing once of technetium 99-polymerised protein perfusion test and 2 cases under-going ≥ twice of technetium 99-polymerised protein perfusion test. The ratio of uptake of techne-tium 99-polymerised protein in tumor tissue to normal tissue, the hepatopulmonary shunting ratio and the therapeutic requirement of 90Y resin microspheres in 10 patients were 5.8±1.2, 4.8%±0.8% and (1.10±0.20)GBq, respectively. (2) Treatment strategy of 90Y resin microspheres TARE. Of the 10 patients, cases treated with whole tumor radioembolisation, radioembolisation of the main target lesion+non-target lesion radiofrequency ablation, radioembolisation of the main target lesion+non-target lesion iodine-125 particles implantation, radioembolisation of the liver lobe or liver segment were 6, 2, 1, 1, respectively. During the treatment period, one elderly case did not receive target therapy combined with immunotherapy due to intolerance, and the remaining 9 cases received target therapy combined with immunotherapy. Of the 10 patients, there were 7 cases receiving once of 90Y resin microspheres TARE, and 3 cases receiving twice of 90Y resin microspheres TARE. (3) Follow-up. All 10 patients were followed up for 4.5(range, 3.0-12.0)months. During the follow-up, none of patient had adverse event associated with 90Y resin microspheres TARE. The tumor diameter, alpha-fetoprotein (AFP), abnormal prothrombin, alanine aminotransferase (ALT), aspartate amino-transferase (AST), albumin (Alb), total bilirubin (TBiL), glutamyltransferase (GGT) of the 10 patients were 96(72,135)mm, 26(6,833)μg/L, 290(56,2 997)Au/L, (36±13)IU/L, (41+16)IU/L, (40±4)g/L, (15.3±4.1)μmol/L, (99±68)IU/L before receiving 90Y microspheres TARE. The above indicators of the 10 patients were 63(43,97)mm, 4(3,357)μg/L, 38(25, 142) Au/L, (40±16)IU/L, (51±28)IU/L, (39±4)g/L, (14.4±1.2) μmol/L, (134±93)IU/L after 90 days of receiving 90Y microspheres TARE. There were significant differences in tumor diameter and abnormal prothrombin ( Z=-2.08, -2.24, P<0.05) and there was no significant difference in AFP, ALT, AST, Alb, TBil, GGT ( Z=-1.27, t=0.63, 1.69, 1.73, 0.67, 1.30, P>0.05). During the follow-up period, 5 cases achieved clinical complete response, 4 cases achieved clinical partial remission, and 1 case experienced non-target lesion progression within 30 days after receiving 90Y resin microspheres TARE. The disease remission rate and disease control rate of the 10 patients were 9/10 and 9/10, respectively. None of patient died during follow-up period. Conclusion:90Y resin microspheres TARE for the treatment of initial unresectable malignant hepatic tumor is safe and feasible, and can achieve satisfactory short-term efficacy when combined with other treatment methods.
8.Performance test of high-flow nasal cannula oxygen therapy device at different altitudes
Chun-Wei HE ; Ya-Ting WANG ; Yi-Long ZHOU ; Hui WANG ; Zi-Yu FU ; De-Dong MA
Chinese Medical Equipment Journal 2024;45(6):49-58
Objective To investigate the performance of brands and types of high-flow nasal cnnula oxygen therapy(HFNC)devices at different altitudes.Methods Four different models of HFNC devices,including R-80S bi-level non-invasive ventilator integrated with HFNC device,HF-60A HFNC device,HFT-300 HFNC device and H-80A HFNC device,were connected with the gas flow meter,simularted head and QuickLung and then put into a low-pressure chamber.The flow rates of the HFNC devices were set to 10,15,20,25,30,35,40,45,50,55 and 60 L/min,and the simulated altitudes of the low-pressure chamber were set to 6 000,5 000,4 000,3 000,2 000,1 000 and 0 m.The actual output airway flow rates,airway pressure changes and trends of the four HFNC devices were recorded at different setting altitudes and flow rates.SPSS 25.0 software was used for statistical analysis.Results The actual output airway flow rates of the four HFNC devices showed an increasing trend as the altitude rose with the simulated altitude of 6 000 m and the setting flow rate kept constant,which increased slowly and even went to decrease when the altitude and flow rate exceeded some limits.The degree of changes in the flow rate with the increasing altitude varied,and there was no uniform pattern.With the rising of altitude,the actual output airway pressure of the four HFNC devices with the flow rate raning from 10 to 35 L/min also increased gradually,which showed a decreasing trend(turning point)after going up to some certain value when the flow rate exceeded 35 L/min,and the altitude where the turning point appeared was lowered as the flow rate increased.Conclusion The actual output airway flow rates and airway pressure during HFNC rise at a high-altitude environment,and generally considerations have to be taken on required airway pressure,patient comfort and the altitude of the patient's usual place of residence when setting the flow rates of the HFNC device.[Chinese Medical Equipment Journal,2024,45(6):49-58]
9.Simulation study of brain electrical impedance tomography based on radial basis function neural network
Tao ZHANG ; Xin-Yi WANG ; Jiang-Hui HAO ; Lei LIANG ; Can-Hua XU ; Feng FU ; Xue-Chao LIU
Chinese Medical Equipment Journal 2024;45(10):1-6
Objective To study the ability of radial basis function neural network(RBFNN)with different implementations for electrical impedance tomography(EIT)under real brain shapes,to evaluate the advantages and disadvantages of different approaches,and to provide a reference for the selection of practical imaging methods.Methods COMSOL Multiphysics was used to establish a multilayer 2D model with real structure based on brain CT and an EIT simulation dataset.The effects of the exact RBFNN,the orthogonal least squares-based RBFNN(OLS RBFNN)and the K-Means-based BRFNN(K-Means RBFNN)on the image reconstruction result were explored with the dataset constructed.The root mean square error(RMSE)and image correlation coefficient(ICC)were adopted to evaluate the imaging results.Results EIT could be completed with all the three RBFNNs without noise,and the exact RBFNN had the best results with average ICC and RMSE of 0.784 and 0.467,respectively,in the test set.The OLS RBFNN had the best imaging results at a hidden node of 50,with an average ICC and RMSE of 0.788 and 0.462,respectively.The K-Means RBFNN achieved the best imaging results at noise levels of 30,40,50,60,70 and 80 dB with stable ICC and RMSE and high robustness.Conclusion All the three RBFNNs can be used for brain EIT image reconstruction with their own advantages and disadvantages,and the RBFNN has to be selected for EIT reconstruc-tion based on considerations on actual conditions.[Chinese Medical Equipment Journal,2024,45(10):1-6]
10.Post-operative healthcare-associated infection influencing factors and me-diating effect of diagnosis-intervention packet payment differentials in colorectal cancer patients
Yu RONG ; Qian-Qian HUANG ; Jia-Yi OU ; Shu-Liang YU ; Ye-Ying SONG ; Wei-Qun LU ; Li-Ming REN ; Yao FU ; Jian-Hui LU
Chinese Journal of Infection Control 2024;23(11):1421-1429
Objective To explore the potential influencing factors of post-operative healthcare-associated infection(HAI)in colorectal cancer patients,as well as the mediating effect relationship between the influencing factors and the diagnosis-intervention packet(DIP)payment differentials.Methods Medical data of patients who underwent colorectal cancer surgery in a tertiary first-class cancer hospital in Guangzhou were retrospectively analyzed.According to HAI status,patients were divided into infection group and non-infection group.Baseline demographic information and differences in DIP payment differentials between two groups of patients were compared by rank sum test or chi-square test.The influence of each potential factor on the occurrence of HAI was analyzed by logistic re-gression.Mediating analysis was preformed by bootstrap method,and mediating effect of HAI and total hospitaliza-tion days on DIP payment differentials was evaluated.Results A total of 350 patients were included in analysis,50 were in the infection group and 300 in the non-infection group.The incidence of HAI was 14.29%.Logistic regres-sion analysis result showed that risk of HAI in patients with central venous catheterization ≥10.00 days was 13.558 times higher than that<10.00 days(P<0.001);risk of HAI in patients with urinary catheterization ≥3.00 days was 2.388 times higher than that<3.00 days(P=0.022).There were all statistically significant differences in DIP payment differentials among patients with different ages,prognostic nutritional index(PNI),HAI status,total length of hospitalization stay,duration of surgery,central venous catheterization days,and catheterization days(all P<0.05).The mediating analysis results showed that the occurrence of HAI resulted a change in DIP payment di-fferentials by affecting the total number of hospitalization days.The mediating effect value of total hospitalization days was 0.038,accounting for 35.68%of the total effect.Conclusion Medical institutions should pay attention to HAI resulting from prolonged central venous and urinary catheterization in patients underwent surgery for colorectal cancer,reducing the total length of hospital stay,thus reducing the overruns associated with the increased DIP pay-ment differentials.

Result Analysis
Print
Save
E-mail