1.Bacteroi des fragilis-derived succinic acid promotes the degradation of uric acid by inhibiting hepatic AMPD2: Insight into how plant-based berberine ameliorates hyperuricemia.
Libin PAN ; Ru FENG ; Jiachun HU ; Hang YU ; Qian TONG ; Xinyu YANG ; Jianye SONG ; Hui XU ; Mengliang YE ; Zhengwei ZHANG ; Jie FU ; Haojian ZHANG ; Jinyue LU ; Zhao ZHAI ; Jingyue WANG ; Yi ZHAO ; Hengtong ZUO ; Xiang HUI ; Jiandong JIANG ; Yan WANG
Acta Pharmaceutica Sinica B 2025;15(10):5244-5260
In recent decades, the prevalence of hyperuricemia and gout has increased dramatically due to lifestyle changes. The drugs currently recommended for hyperuricemia are associated with adverse reactions that limit their clinical use. In this study, we report that berberine (BBR) is an effective drug candidate for the treatment of hyperuricemia, with its mechanism potentially involving the modulation of gut microbiota and its metabolite, succinic acid. BBR has demonstrated good therapeutic effects in both acute and chronic animal models of hyperuricemia. In a clinical trial, oral administration of BBR for 6 months reduced blood uric acid levels in 22 participants by modulating the gut microbiota, which led to an increase in the abundance of Bacteroides and a decrease in Clostridium sensu stricto_1. Furthermore, Bacteroides fragilis was transplanted into ICR mice, and the results showed that Bacteroides fragilis exerted a therapeutic effect on uric acid similar to that of BBR. Notably, succinic acid, a metabolite of Bacteroides, significantly reduced uric acid levels. Subsequent cell and animal experiments revealed that the intestinal metabolite, succinic acid, regulated the upstream uric acid synthesis pathway in the liver by inhibiting adenosine monophosphate deaminase 2 (AMPD2), an enzyme responsible for converting adenosine monophosphate (AMP) to inosine monophosphate (IMP). This inhibition resulted in a decrease in IMP levels and an increase in phosphate levels. The reduction in IMP led to a decreased downstream production of hypoxanthine, xanthine, and uric acid. BBR also demonstrated excellent renoprotective effects, improving nephropathy associated with hyperuricemia. In summary, BBR has the potential to be an effective treatment for hyperuricemia through the gut-liver axis.
2.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
3.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
4.Research progress on the mechanisms of Tau phosphorylation and its kinases in hypoxic-ischemic brain damage.
Qi-Yi HUANG ; You XIANG ; Jia-Hang TANG ; Li-Jia CHEN ; Kun-Lin LI ; Wei-Fang ZHAO ; Qian WANG
Acta Physiologica Sinica 2025;77(1):139-150
Hypoxic-ischemic brain damage (HIBD) is one of the main causes of disability in middle-aged and elderly people, as well as high mortality rates and long-term physical impairments in newborns. The pathological manifestations of HIBD include neuronal damage and loss of myelin sheaths. Tau protein is an important microtubule-associated protein in brain, exists in neurons and oligodendrocytes, and regulates various cellular activities such as cell differentiation and maturation, axonal transport, and maintenance of cellular cytoskeleton structure. Phosphorylation is a common chemical modification of Tau. In physiological condition, it maintains normal cell cytoskeleton and biological functions by regulating Tau structure and function. In pathological conditions, it leads to abnormal Tau phosphorylation and influences its structure and functions, resulting in Tauopathies. Studies have shown that brain hypoxia-ischemia could cause abnormal alteration in Tau phosphorylation, then participating in the pathological process of HIBD. Meanwhile, brain hypoxia-ischemia can induce oxidative stress and inflammation, and multiple Tau protein kinases are activated and involved in Tau abnormal phosphorylation. Therefore, exploring specific molecular mechanisms by which HIBD activates Tau protein kinases, and elucidating their relationship with abnormal Tau phosphorylation are crucial for future researches on HIBD related treatments. This review aims to focus on the mechanisms of the role of Tau phosphorylation in HIBD, and the potential relationships between Tau protein kinases and Tau phosphorylation, providing a basis for intervention and treatment of HIBD.
Humans
;
tau Proteins/physiology*
;
Phosphorylation
;
Hypoxia-Ischemia, Brain/physiopathology*
;
Animals
;
Oxidative Stress
5.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
6.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
7.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
8.Dosimetric effect of jaw widths on stereotactic body radiotherapy for hepatocellular carcinoma
Xia-Yu HANG ; Yi-Kun LI ; Jun HU ; Ruo-Qi CAO ; Yan ZHANG ; Nan XU ; Xian-Qiang SONG ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(7):51-55
Objective To investigate the radiotherapy dose impacts of different jaw widths on stereotactic body radiotherapy(SBRT)for hepatocellular carcinoma(HCC)with the hilical tomotherapy(HT)planning system.Methods Totally 16 HCC patients who received radiotherapy at some hospital from March 2021 to August 2023 were selected,and the planning was carried out with the same pitch,modulation factors and optimization conditions and the jaw widths being 1.0,2.5 and 5.0 cm.The dosimetric differences due to the jaw widths in planned targets and organs at risk(OAR)were compared,and the planned treatment time,monitor unit,gantry rotations and gantry period were evaluated.SPSS 22.0 was used for statistical analysis.Results Better dosimetric parameters and lower doses to OARs could be got with lower jaw widths.The widened jaw widths resulted in reduced planned treatment time,decreased monitor units and gantry rotations,shortened gantry period while enhanced treatment efficiency.Conclusion A 2.5 cm jaw width for HT planning contributes to improving treatment efficiency during HCC SBRT under the premise of ensured target dose distribution and satisfactory dose to OAR for clinical require-ments.[Chinese Medical Equipment Journal,2024,45(7):51-55]
9.Licorice-saponin A3 is a broad-spectrum inhibitor for COVID-19 by targeting viral spike and anti-inflammation
Yang YI ; Wenzhe LI ; Kefang LIU ; Heng XUE ; Rong YU ; Meng ZHANG ; Yang-Oujie BAO ; Xinyuan LAI ; Jingjing FAN ; Yuxi HUANG ; Jing WANG ; Xiaomeng SHI ; Junhua LI ; Hongping WEI ; Kuanhui XIANG ; Linjie LI ; Rong ZHANG ; Xin ZHAO ; Xue QIAO ; Hang YANG ; Min YE
Journal of Pharmaceutical Analysis 2024;14(1):115-127
Currently,human health due to corona virus disease 2019(COVID-19)pandemic has been seriously threatened.The coronavirus severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)spike(S)protein plays a crucial role in virus transmission and several S-based therapeutic approaches have been approved for the treatment of COVID-19.However,the efficacy is compromised by the SARS-CoV-2 evolvement and mutation.Here we report the SARS-CoV-2 S protein receptor-binding domain(RBD)inhibitor licorice-saponin A3(A3)could widely inhibit RBD of SARS-CoV-2 variants,including Beta,Delta,and Omicron BA.1,XBB and BQ1.1.Furthermore,A3 could potently inhibit SARS-CoV-2 Omicron virus in Vero E6 cells,with EC50 of 1.016 pM.The mechanism was related to binding with Y453 of RBD deter-mined by hydrogen-deuterium exchange mass spectrometry(HDX-MS)analysis combined with quan-tum mechanics/molecular mechanics(QM/MM)simulations.Interestingly,phosphoproteomics analysis and multi fluorescent immunohistochemistry(mIHC)respectively indicated that A3 also inhibits host inflammation by directly modulating the JNK and p38 mitogen-activated protein kinase(MAPK)path-ways and rebalancing the corresponding immune dysregulation.This work supports A3 as a promising broad-spectrum small molecule drug candidate for COVID-19.
10.Research progress on application of nutritional assessment methods in patients with chronic kidney disease
Ya-Yong LUO ; Zhe-Yi DONG ; Wen-Wen LIN ; Qian WANG ; Chun-Liu DENG ; Hang-Tian LI ; Xiang-Mei CHEN
Medical Journal of Chinese People's Liberation Army 2024;49(12):1437-1443
Malnutrition is a significant risk factor for the progression of chronic kidney disease(CKD),and monitoring the nutritional status of CKD patients is crucial for delaying disease progression and improving patient prognosis.Currently,there is a scarcity of studies on malnutrition in CKD,and a unified standard for nutritional assessment in CKD is still lacking.Clinical evaluation must be conducted according to the condition of patients,combined with multiple indicators.Nutritional screening and assessment scales are the common nutritional assessment methods;however,due to limitations in the applicable populations,the applicability of some scales for the CKD population requires further verification.Additionally,anthropometric indicators,body composition analysis,and clinical laboratory indicators can also reflect human nutritional status,each with its respective advantages and limitations.This review summarizes the research status and clinical application characteristics of various nutritional assessment methods in CKD patients,aiming to provide references for the clinical assessment of malnutrition in CKD.

Result Analysis
Print
Save
E-mail