1.Sclera Vessel Segmentation Based on Fusion Filtering and Reflection Suppression
Ming-Xuan FAN ; Zong-Qing MA ; Chu-Xiang GAO ; Yi-Xuan SHI ; Zi-Hang ZHANG ; Zhe-Xuan JIA ; Fan FAN ; Guo-Liang HUANG ; Jiang ZHU
Progress in Biochemistry and Biophysics 2026;53(5):1195-1206
ObjectiveIn traditional Chinese medicine (TCM), the foundational doctrine that the eyes reflect the essence of the internal viscera establishes ocular observation as a cornerstone of diagnostic practice. Specifically, the morphological characteristics and coloration variations of the scleral microvasculature serve as critical clinical indicators for assessing the dynamic balance of Qi and Blood, as well as the pathological status of internal organs. Historically, however, TCM eye diagnosis has relied predominantly on the subjective clinical experience and visual acuity of individual practitioners, leading to inherent challenges in standardization and reproducibility. While automated computer-aided diagnostic systems offer a promising solution, existing vessel segmentation algorithms encounter significant domain-specific bottlenecks when applied to scleral imagery. These challenges primarily stem from the highly reflective and moist nature of the ocular surface, which generates severe reflective interference. Furthermore, the inherent low contrast of fine capillary networks against complex background textures, compounded by non-uniform illumination, frequently results in high false-positive rates, misdetections, and severe vessel fragmentation. To address these critical limitations and advance the objective quantification of TCM diagnostics, this paper proposes a novel, highly robust sclera vessel segmentation framework that innovatively integrates Frangi-Sato dual-filter adaptive enhancement with pixel-level reflection detection. MethodsThe proposed methodology systematically addresses the segmentation pipeline through three synergistic stages. First, to overcome the structural limitations of single-filter approaches, a multi-scale weighted fusion strategy is meticulously designed to harness the complementary extraction capabilities of both Frangi and Sato filters. This adaptive enhancement optimally balances the preservation of main vessel trunk continuity with the heightened sensitivity required for delineating delicate, low-contrast peripheral capillaries. Second, to tackle the persistent issue of reflective highlights, a sophisticated multi-feature synergistic reflection detection module is introduced. By jointly analyzing local information entropy, gradient field variations, and intensity statistical distributions, this module achieves precise, pixel-level identification and elimination of reflective artifacts without compromising the underlying vascular structures. Finally, a dual-level adaptive thresholding strategy, featuring an innovative “core protection” mechanism, is implemented. This critical step effectively suppresses complex background noise while rigorously preserving the structural and topological integrity of the intricate vessel network, preventing the structural breaks often seen in conventional binarization methods. ResultsThe efficacy of the proposed framework was rigorously evaluated using both self-constructed clinical datasets specifically acquired for TCM research and standardized public datasets. Extensive experimental results demonstrate that the proposed method consistently outperforms state-of-the-art traditional approaches and contemporary deep learning models. Specifically, the proposed method achieves a Dice similarity coefficient of approximately 0.71 on the private clinical dataset, and secures the best performance across the majority of quantitative metrics on both datasets. Notably, the framework exhibits exceptional robustness and generalization capabilities in highly challenging scenarios characterized by intense reflective interference, low signal-to-noise ratios, and cross-domain image variations. ConclusionThis study successfully realizes the high-integrity, automated segmentation of scleral vessel networks under complex clinical imaging conditions. By overcoming the fundamental algorithmic challenges of reflection interference and micro-vessel loss, the proposed methodology provides potential support for the digitization, objective standardization, and intelligent advancement of modern TCM eye diagnosis systems.
2.Sclera Vessel Segmentation Based on Fusion Filtering and Reflection Suppression
Ming-Xuan FAN ; Zong-Qing MA ; Chu-Xiang GAO ; Yi-Xuan SHI ; Zi-Hang ZHANG ; Zhe-Xuan JIA ; Fan FAN ; Guo-Liang HUANG ; Jiang ZHU
Progress in Biochemistry and Biophysics 2026;53(5):1195-1206
ObjectiveIn traditional Chinese medicine (TCM), the foundational doctrine that the eyes reflect the essence of the internal viscera establishes ocular observation as a cornerstone of diagnostic practice. Specifically, the morphological characteristics and coloration variations of the scleral microvasculature serve as critical clinical indicators for assessing the dynamic balance of Qi and Blood, as well as the pathological status of internal organs. Historically, however, TCM eye diagnosis has relied predominantly on the subjective clinical experience and visual acuity of individual practitioners, leading to inherent challenges in standardization and reproducibility. While automated computer-aided diagnostic systems offer a promising solution, existing vessel segmentation algorithms encounter significant domain-specific bottlenecks when applied to scleral imagery. These challenges primarily stem from the highly reflective and moist nature of the ocular surface, which generates severe reflective interference. Furthermore, the inherent low contrast of fine capillary networks against complex background textures, compounded by non-uniform illumination, frequently results in high false-positive rates, misdetections, and severe vessel fragmentation. To address these critical limitations and advance the objective quantification of TCM diagnostics, this paper proposes a novel, highly robust sclera vessel segmentation framework that innovatively integrates Frangi-Sato dual-filter adaptive enhancement with pixel-level reflection detection. MethodsThe proposed methodology systematically addresses the segmentation pipeline through three synergistic stages. First, to overcome the structural limitations of single-filter approaches, a multi-scale weighted fusion strategy is meticulously designed to harness the complementary extraction capabilities of both Frangi and Sato filters. This adaptive enhancement optimally balances the preservation of main vessel trunk continuity with the heightened sensitivity required for delineating delicate, low-contrast peripheral capillaries. Second, to tackle the persistent issue of reflective highlights, a sophisticated multi-feature synergistic reflection detection module is introduced. By jointly analyzing local information entropy, gradient field variations, and intensity statistical distributions, this module achieves precise, pixel-level identification and elimination of reflective artifacts without compromising the underlying vascular structures. Finally, a dual-level adaptive thresholding strategy, featuring an innovative “core protection” mechanism, is implemented. This critical step effectively suppresses complex background noise while rigorously preserving the structural and topological integrity of the intricate vessel network, preventing the structural breaks often seen in conventional binarization methods. ResultsThe efficacy of the proposed framework was rigorously evaluated using both self-constructed clinical datasets specifically acquired for TCM research and standardized public datasets. Extensive experimental results demonstrate that the proposed method consistently outperforms state-of-the-art traditional approaches and contemporary deep learning models. Specifically, the proposed method achieves a Dice similarity coefficient of approximately 0.71 on the private clinical dataset, and secures the best performance across the majority of quantitative metrics on both datasets. Notably, the framework exhibits exceptional robustness and generalization capabilities in highly challenging scenarios characterized by intense reflective interference, low signal-to-noise ratios, and cross-domain image variations. ConclusionThis study successfully realizes the high-integrity, automated segmentation of scleral vessel networks under complex clinical imaging conditions. By overcoming the fundamental algorithmic challenges of reflection interference and micro-vessel loss, the proposed methodology provides potential support for the digitization, objective standardization, and intelligent advancement of modern TCM eye diagnosis systems.
3.Expert consensus on the application of artificial intelligence in lung cancer screening, diagnosis, and treatment (2026 edition)
Wenzhao ZHONG ; Haibo WANG ; Yi HU ; Hao ZHANG ; Jigang DAI ; Junqiang FAN ; Guibin QIAO ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Zihao CHEN ; Hongxia TIAN ; Lunxu LIU ; Hecheng LI ; Xiaolong YAN ; Zongyang YU ; Zhenbin QIU ; Yihua SUN ; Jing HU ; Yuhang SHI ; Zhifei GUO ; Peng ZHANG ; Kezhong CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):848-856
With the continuous deepening of the concept of precision diagnosis and treatment for lung cancer, how to achieve higher efficiency and accuracy in the screening, diagnosis, and treatment pathways in clinical practice has become an important issue that urgently needs to be overcome. The current clinical difficulty lies in the fact that despite continuous advancements in imaging and molecular diagnostic technologies, there are still limitations in manual efficiency and subjective experience when it comes to massive data analysis and multi-scale feature extraction. Artificial intelligence (AI), especially algorithm systems based on deep learning, is an innovative technology capable of deeply empowering medical big data. This method utilizes algorithms such as convolutional neural networks, combined with radiomics, pathomics, and multi-modal data fusion analysis, demonstrating immense potential in early precise detection and benign-malignant differentiation of pulmonary nodules, digital pathological subtype recognition and non-invasive prediction of driver genes, precise 3D surgical planning and automatic delineation of radiotherapy target volumes, as well as dynamic risk warning during follow-up. This innovative technology provides a brand-new solution for realizing intelligent and individualized lung cancer diagnosis and treatment models. This consensus, based on the latest evidence from evidence-based medicine and combined with the development trends in the AI field and real-world clinical needs, was ultimately formed by gathering the consensus opinions of multidisciplinary experts in radiology, pathology, thoracic surgery, and other fields. The main content covers the application specifications of AI in the three core scenarios of lung cancer screening, diagnosis, and treatment, the technical standards for data collection and algorithm validation, as well as the ethical and regulatory challenges faced at the current stage. It aims to clarify the applicable boundaries of AI as a clinical auxiliary decision support tool, providing scientific guidance and standardized exploration directions for peers currently engaged in or planning to carry out AI-assisted clinical diagnosis, treatment, and translation of lung cancer.
4.Different Acupuncture Therapies for Postherpetic Neuralgia: An Overview of Systematic Reviews and Meta-analysis.
Yun-Fan XIA ; Ruo-Han SUN ; Shi-Min LI ; Yi-Yi WANG ; Rong-Rong LI ; Jian-Qiao FANG
Chinese journal of integrative medicine 2025;31(1):55-67
BACKGROUND:
Postherpetic neuralgia (PHN) is the most common complication of herpes zoster infection and affects patients' quality of life. Acupuncture therapy is regarded as a competitive method of treatment for analgesia.
OBJECTIVE:
To summarize evidence from systematic reviews (SRs) and evaluate the effectiveness and safety of different acupuncture therapies for treating PHN.
METHODS:
Eight electronic databases were searched from their inception to August 5, 2022, including 4 international electronic databases (PubMed, EMBASE, the Cochrane Library, and Web of Science) and 4 Chinese databases (Chinese Biomedical Database, China National Knowledge Infrastructure, VIP Database and Wanfang Database). Methodological quality was assessed by A Measurement Tool to Assess Systematic Reviews 2 (AMSTAR 2). The Risk of Bias in Systematic Review (ROBIS) tool was used to assess the risk of bias in SRs. Evidence level was assessed by the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach.
RESULTS:
Totally, 7 SRs were included, including 128 studies and 9,792 patients. In AMSTAR 2, most of the SRs were of low or critically low levels since they had more than 1 critical deficiency. In ROBIS, 1 SR (14.29%) was rated as high risk, and the other 6 (85.71%) were rated as low risk. In the GRADE system, 9 outcomes (28.13%) were valued as high level, 5 (15.63%) as moderate level, 1 (3.13%) as low, and 17 (53.13%) as very low. In the effectiveness of acupuncture therapy, the group "moxibustion vs. original medical treatment" [mean difference (MD)=-1.44, 95% confidence interval (CI): -1.80 to -1.08, I2=99%, P<0.00001] was of the highest heterogeneity and the group "bloodletting vs. original medical treatment" (MD=-2.80, 95% CI: -3.14 to -2.46, I2=0, P<0.00001) was of the lowest heterogeneity. Six SRs have reported the safety of their studies and no serious events were shown in the treatment and control groups.
CONCLUSIONS
Acupuncture therapy seems to be effective in treating PHN. Despite the evidence that suggested the advantages of acupuncture therapy in relieving pain and promoting efficacy and safety, the methodological quality was quite low. Further studies should pay more attention to the quality of original studies and evidence for SRs to confirm these findings. (PROSPERO registration No. CRD42022344790).
Humans
;
Neuralgia, Postherpetic/therapy*
;
Acupuncture Therapy/methods*
;
Systematic Reviews as Topic
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
8.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
9.Analysis of risk factors for diaphragmatic dysfunction after cardiovascular surgery with extracorporeal circulation: A retrospective cohort study
Xupeng YANG ; Yi SHI ; Fengbo PEI ; Simeng ZHANG ; Hao MA ; Zengqiang HAN ; Zhou ZHAO ; Qing GAO ; Xuan WANG ; Guangpu FAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1140-1145
Objective To clarify the risk factors of diaphragmatic dysfunction (DD) after cardiac surgery with extracorporeal circulation. Methods A retrospective analysis was conducted on the data of patients who underwent cardiac surgery with extracorporeal circulation in the Department of Cardiovascular Surgery of Peking University People's Hospital from January 2023 to March 2024. Patients were divided into two groups according to the results of bedside diaphragm ultrasound: a DD group and a control group. The preoperative, intraoperative, and postoperative indicators of the patients were compared and analyzed, and independent risk factors for DD were screened using multivariate logistic regression analysis. Results A total of 281 patients were included, with 32 patients in the DD group, including 23 males and 9 females, with an average age of (64.0±13.5) years. There were 249 patients in the control group, including 189 males and 60 females, with an average age of (58.0±11.2) years. The body mass index of the DD group was lower than that of the control group [(18.4±1.5) kg/m2 vs. (21.9±1.8) kg/m2, P=0.004], and the prevalence of hypertension, chronic obstructive pulmonary disease, heart failure, and renal insufficiency was higher in the DD group (P<0.05). There was no statistical difference in intraoperative indicators (operation method, extracorporeal circulation time, aortic clamping time, and intraoperative nasopharyngeal temperature) between the two groups (P>0.05). In terms of postoperative aspects, the peak postoperative blood glucose in the DD group was significantly higher than that in the control group (P=0.001), and the proportion of patients requiring continuous renal replacement therapy was significantly higher than that in the control group (P=0.001). The postoperative reintubation rate, tracheotomy rate, mechanical ventilation time, and intensive care unit stay time in the DD group were higher or longer than those in the control group (P<0.05). Multivariate logistic regression analysis showed that low body mass index [OR=0.72, 95%CI (0.41, 0.88), P=0.011], preoperative dialysis [OR=2.51, 95%CI (1.89, 4.14), P=0.027], low left ventricular ejection fraction [OR=0.88, 95%CI (0.71, 0.93), P=0.046], and postoperative hyperglycemia [OR=3.27, 95%CI (2.58, 5.32), P=0.009] were independent risk factors for DD. Conclusion The incidence of DD is relatively high after cardiac surgery, and low body mass index, preoperative renal insufficiency requiring dialysis, low left ventricular ejection fraction, and postoperative hyperglycemia are risk factors for DD.
10.Low contrast dose and low flow rate one-stop craniocervical CT angiography-cerebral CT perfusion for detecting carotid atherosclerosis
Yuanyuan CUI ; Rongrong FAN ; Qinling JIANG ; Xiaolei SHI ; An SUN ; Chenshi ZHANG ; Weimin YUAN ; Shiyuan LIU ; Yi XIAO
Chinese Journal of Medical Imaging Technology 2025;41(7):1144-1149
Objective To explore the value of low contrast dose and low flow rate one-stop craniocervical CT angiography(CT A)-cerebral CT perfusion(CTP)for detecting carotid atherosclerosis(CAS).Methods Totally 117 CAS patients were prospectively enrolled and divided into group A(n=19),B(n=52),C(n=46),and low contrast dose and low flow rate one-stop craniocervical CTA-brain CTP scanning,low contrast dose and low flow rate craniocervical CT A scanning,as well as conventional craniocervical CT A scanning were performed,respectively.Virtual monoenergetic images(VMI)of 40,50 and 60 keV were reconstructed in group A and B.The subjective and objective evaluations of image quality were compared among 3 groups.Results Subjective scores of image quality and diagnostic confidence of 40 and 50 keV VMI,and the diagnostic confidence of 60 keV VMI in group A and B were not significant different compared with those in group C(all P>0.05).Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of each segment of craniocervical blood vessels at 40 and 50 keV VMI in group A and B were all higher than those in group C(all P<0.05).CNR of cavernous sinus segment of internal carotid artery(C5 segment),horizontal segment of middle cerebral artery(MCA)(A1 segment),lateral sulcus segment of MCA(M2 segment)and basilar artery(BA)segment in group A at 60 keV VMI were all higher than those in group C(all P<0.05).SNR of C5 segment,A1 segment and BA segment,as well as CNR of BA segment of 60 keV VMI in group B were all higher than those in group C(all P<0.05).Conclusion Low contrast dose and low flow rate one-stop craniocervical was feasible for detecting CAS.

Result Analysis
Print
Save
E-mail