1.Interpretation of Pharmacovigilance Guidelines for Clinical Application of Oral Chinese Patent Medicines
Wenxi PENG ; Meng QIAO ; Lianxin WANG ; Yuanyuan LI ; Xiuhui LI ; Xin CUI ; Zijia CHEN ; Xinyi CHEN ; Yi DENG ; Yanming XIE ; Zhifei WANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):152-160
The Pharmacovigilance Guidelines for Clinical Application of Oral Chinese Patent Medicines (hereinafter referred to as the Guidelines) is first specialized in the field of drug safety for oral Chinese patent medicines (OCPMs) in China. Rooted in China's healthcare context, the Guidelines address the unique usage patterns and risk characteristics of OCPMs, filling a regulatory gap in the pharmacovigilance framework specific to this category. To facilitate accurate understanding and effective implementation of the Guidelines, and to promote the standardized development of pharmacovigilance practices for OCPMs, this study offered a systematic interpretation based on its three core components. In the domain of risk monitoring and reporting, the paper analyzed the rationale for multi-source information integration and clarified the criteria for identifying key products and target populations for intensive monitoring. Regarding risk assessment, the Guidelines were examined from three dimensions of formulation components, medication behaviors, and population to address complex safety issues arising from medicinal constituents, irrational use, and individual susceptibility. In the area of risk control, the analysis focused on context-based interventions and dynamic closed-loop management strategies, exploring practical pathways to shift from passive response to proactive risk mitigation. Furthermore, this paper evaluated the applied value of the Guidelines and identified implementation challenges, such as insufficient capacity at the primary-care level and limited digital infrastructure. In response, the study proposed optimization strategies including establishing a dynamic updating mechanism, strengthening training at the grassroots level, and incorporating artificial intelligence to enhance pharmacovigilance capacity. This interpretation aims to provide actionable insights for marketing authorization holders (including manufacturers), pharmaceutical distributors, healthcare institutions, and research organizations, ultimately supporting the establishment and refinement of a full lifecycle pharmacovigilance system for OCPMs.
2.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
3.Evaluation of the Angle Deviation between Pilot Holes and Actual Implanted Pedicle Screw Trajectories in Freehand Pedicle Screw Placement for Thoracolumbar Spine Surgery: The Impact of Tapping and Work Experience
Jie SHAO ; Shaokang HUANG ; Yiping LUO ; Bingkun MENG ; Qunfei YU ; Yi ZHANG ; Wei LI ; Yushu BAI ; Ziqiang CHEN
Clinics in Orthopedic Surgery 2026;18(1):87-95
Background:
To investigate directional deviations between pilot holes and final pedicle screw trajectories in freehand placement and analyze risk factors for misplacement. While pedicle screws are widely used in thoracolumbosacral surgery, directional deviations between pilot holes and final screw trajectories remain understudied as potential risk factors for misplacement.
Methods:
Thirty-three patients undergoing posterior fixation were prospectively enrolled. Inertial measurement units (IMUs) tracked the spatial positions of pedicle finders and screwdrivers via custom software. Surgeons (n = 6) were stratified into senior, middle, and junior groups. Analyzed variables included the use of tapping, surgeon experience, spinal deformity status, screw tip morphology, and surgical parameters.
Results:
Among 198 implanted screws (6.00 ± 2.88/patient), all exhibited trajectory deviations (8.12° ± 3.47°). Tapping significantly reduced deviations (7.23° ± 3.23° vs. 8.87° ± 3.31°, p < 0.01). Senior surgeons achieved smaller deviations (7.34° ± 3.33°) than the middle group (8.60° ± 3.51°, p = 0.039) and junior group (8.68° ± 3.49°, p = 0.022). Multivariate analysis confirmed tapping (p = 0.001) and senior experience (p = 0.023) as protective factors. No significant associations emerged for spinal deformity (8.43° ± 3.73° vs. 7.97° ± 3.35°, p = 0.377), screw tip type (cylindrical, 8.43° ± 3.26° vs. tapered, 8.07 ± 3.51°; p = 0.637), obesity, or surgical position parameters.
Conclusions
Freehand pedicle screw placement consistently produces trajectory deviations from pilot holes, and surgeon experience and tapping are modifiable protective factors. The IMU-based tracking system enables quantitative surgical motion analysis, suggesting its utility for training optimization and technique standardization.
4.Research progress of nano drug delivery system based on metal-polyphenol network for the diagnosis and treatment of inflammatory diseases
Meng-jie ZHAO ; Xia-li ZHU ; Yi-jing LI ; Zi-ang WANG ; Yun-long ZHAO ; Gao-jian WEI ; Yu CHEN ; Sheng-nan HUANG
Acta Pharmaceutica Sinica 2025;60(2):323-336
Inflammatory diseases (IDs) are a general term of diseases characterized by chronic inflammation as the primary pathogenetic mechanism, which seriously affect the quality of patient′s life and cause significant social and medical burden. Current drugs for IDs include nonsteroidal anti-inflammatory drugs, corticosteroids, immunomodulators, biologics, and antioxidants, but these drugs may cause gastrointestinal side effects, induce or worsen infections, and cause non-response or intolerance. Given the outstanding performance of metal polyphenol network (MPN) in the fields of drug delivery, biomedical imaging, and catalytic therapy, its application in the diagnosis and treatment of IDs has attracted much attention and significant progress has been made. In this paper, we first provide an overview of the types of IDs and their generating mechanisms, then sort out and summarize the different forms of MPN in recent years, and finally discuss in detail the characteristics of MPN and their latest research progress in the diagnosis and treatment of IDs. This research may provide useful references for scientific research and clinical practice in the related fields.
5.Study on accumulation of polysaccharide and steroid components in Polyporus umbellatus infected by Armillaria spp.
Ming-shu YANG ; Yi-fei YIN ; Juan CHEN ; Bing LI ; Meng-yan HOU ; Chun-yan LENG ; Yong-mei XING ; Shun-xing GUO
Acta Pharmaceutica Sinica 2025;60(1):232-238
In view of the few studies on the influence of
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
8.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
9.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
10.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.

Result Analysis
Print
Save
E-mail