1.Changes in the body shape and ergonomic compatibility for functional dimensions of desks and chairs for students in Harbin during 2010-2024
Chinese Journal of School Health 2025;46(3):315-320
Objective:
To analyze the change trends in the body shape indicators and proportions of students in Harbin from 2010 to 2024, and to investigate ergonomic compatibility of functional dimensions of school desks and chairs with current student shape indicators, so as to provide a reference for revising furniture standards of desks and chairs.
Methods:
Between September and November of both 2010 and 2024, a combination of convenience sampling and stratified cluster random sampling was conducted across three districts in Harbin, yielding samples of 6 590 and 6 252 students, respectively. Anthropometric shape indicators cluding height, sitting height, crus length, and thigh length-and their proportional changes were compared over the 15-year period. The 2024 data were compared with current standard functional dimensions of school furniture. The statistical analysis incorporated t-test and Mann-Whitney U- test.
Results:
From 2010 to 2024, average height increased by 1.8 cm for boys and 1.5 cm for girls; sitting height increased by 1.5 cm for both genders; crus length increased by 0.3 cm for boys and 0.4 cm for girls; and thigh length increased by 0.5 cm for both genders. The ratios of sitting height to height, and sitting height to leg length increased by less than 0.1 . The difference between desk chair height and 1/3 sitting height ranged from 0.4-0.8 cm. Among students matched with size 0 desks and chairs, 22.0% had a desk to chair height difference less than 0, indicating that the desk to chair height difference might be insufficient for taller students. The differences between seat height and fibular height ranged from -1.4 to 1.1 cm; and the differences between seat depth and buttock popliteal length ranged from -9.8 to 3.4 cm. Among obese students, the differences between seat width and 1/2 hip circumference ranged from -20.5 to -8.7 cm, while it ranged from -12.2 to -3.8 cm among non obese students.
Conclusion
Current furniture standards basically satisfy hygienic requirements; however, in the case of exceptionally tall and obese students, ergonomic accommodations such as adaptive seating allocation or personalized adjustments are recommended to meet hygienic requirements.
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Analysis of risk factors for diaphragmatic dysfunction after cardiovascular surgery with extracorporeal circulation: A retrospective cohort study
Xupeng YANG ; Yi SHI ; Fengbo PEI ; Simeng ZHANG ; Hao MA ; Zengqiang HAN ; Zhou ZHAO ; Qing GAO ; Xuan WANG ; Guangpu FAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1140-1145
Objective To clarify the risk factors of diaphragmatic dysfunction (DD) after cardiac surgery with extracorporeal circulation. Methods A retrospective analysis was conducted on the data of patients who underwent cardiac surgery with extracorporeal circulation in the Department of Cardiovascular Surgery of Peking University People's Hospital from January 2023 to March 2024. Patients were divided into two groups according to the results of bedside diaphragm ultrasound: a DD group and a control group. The preoperative, intraoperative, and postoperative indicators of the patients were compared and analyzed, and independent risk factors for DD were screened using multivariate logistic regression analysis. Results A total of 281 patients were included, with 32 patients in the DD group, including 23 males and 9 females, with an average age of (64.0±13.5) years. There were 249 patients in the control group, including 189 males and 60 females, with an average age of (58.0±11.2) years. The body mass index of the DD group was lower than that of the control group [(18.4±1.5) kg/m2 vs. (21.9±1.8) kg/m2, P=0.004], and the prevalence of hypertension, chronic obstructive pulmonary disease, heart failure, and renal insufficiency was higher in the DD group (P<0.05). There was no statistical difference in intraoperative indicators (operation method, extracorporeal circulation time, aortic clamping time, and intraoperative nasopharyngeal temperature) between the two groups (P>0.05). In terms of postoperative aspects, the peak postoperative blood glucose in the DD group was significantly higher than that in the control group (P=0.001), and the proportion of patients requiring continuous renal replacement therapy was significantly higher than that in the control group (P=0.001). The postoperative reintubation rate, tracheotomy rate, mechanical ventilation time, and intensive care unit stay time in the DD group were higher or longer than those in the control group (P<0.05). Multivariate logistic regression analysis showed that low body mass index [OR=0.72, 95%CI (0.41, 0.88), P=0.011], preoperative dialysis [OR=2.51, 95%CI (1.89, 4.14), P=0.027], low left ventricular ejection fraction [OR=0.88, 95%CI (0.71, 0.93), P=0.046], and postoperative hyperglycemia [OR=3.27, 95%CI (2.58, 5.32), P=0.009] were independent risk factors for DD. Conclusion The incidence of DD is relatively high after cardiac surgery, and low body mass index, preoperative renal insufficiency requiring dialysis, low left ventricular ejection fraction, and postoperative hyperglycemia are risk factors for DD.
8.Impact of Radial Artery Graft Anastomosis Strategies on Flow Characteristics and Early Patency in Coronary Artery Bypass Grafting
Zengqiang HAN ; Guangpu FAN ; Zhou ZHAO ; Yi SHI ; Yu CHEN
Chinese Circulation Journal 2024;39(2):127-132
Objectives:The aim of this study was to assess the influence of graft anastomosis strategies of radial artery on the flow characteristics and early patency in coronary artery bypass grafting(CABG). Methods:Present study enrolled 99 patients(92 males,7 females,aged[57.2±8.7]years),who underwent isolated CABG using a radial artery(RA)graft from January 2019 to December 2021 in our department.The RA was proximally anastomosed to the aorta in 79 patients(group 1)and to another graft as a composite graft in 20 patients(group 2).The intraoperative flow characteristics were evaluated with the transit time flow measurement(TTFM),and the graft patency was assessed by computed tomography coronary angiograms perioperatively and at 1year after operation respectively. Results:Baseline characteristics were similar between the two groups(all P>0.05).There was no perioperative death.Incidence of minimally invasive cardiac surgery for CABG(MICS CABG)and mean flow(MF)of RA grafts were both higher in group 2 than in group 1(all P<0.05).Perioperative RA graft failure rate was 24.2%(n=24),which tended to be lower in group 2 than in group 1(10.0%vs.27.8%,P=0.096).CT angiography showed that RA graft failure reduced to 16.1%at one year after operation.Compared to patency group,patients with failure RA grafts perioperatively had higher pulse index(PI)and lower intraoperative MF(all P<0.05).Patients with failure RA grafts at one year after operation had higher PI and more bypassed to the right coronary artery(RCA)target territories of RA grafts(all P<0.05). Conclusions:RA proximal anastomosis to the aorta or to another graft dose not affect the perioperative patency in CABG.Some RA graft that failed perioperatively might recanalize at one year after operation.High intraoperative PI and bypassed to RCA of RA grafts may be predictors of graft failure at one year after operation.
9.Comprehensive Analysis of Proteins and Their Phosphorylation in Milk-derived Exosomes From Different Species
Chang-Mei LIU ; Yi-Fan HU ; Wen-Yan CHEN ; Dan LIU ; Jie SHI ; Gang-Long YANG
Progress in Biochemistry and Biophysics 2024;51(7):1697-1710
ObjectiveExosomes are microvesicles which could be secreted by all cell types with diameters between 30 and 150 nm. It was widely distributed in body fluids including blood, urine, and breast milk. Exosomes are considered as potential biomarkers and drug carriers by reason of containing nucleic acids, lipids, proteins and other bioactive molecules. Milk-derived exosomes have been widely used as drug delivery carriers to treat targeted diseases with a lower cost, higher biocompatibility and lower immunogenicity. Until now, there is no research about the milk-derived exosomes phosphorylation to reveal the difference of protein phosphorylation in different species of milk. To investigate the pathways and proteins with specific functions, phosphorylated proteomic analysis of milk-derived exosomes from different species is performed, and provide new ideas for exploring diversified treatments of disease. MethodsWhey and exosomes derived from bovine, porcine and caprine milk were performed for proteomics and phosphoproteomics analysis. The relationship between milk exosome proteins from different species and signaling pathways were analyzed using bioinformatics tools. ResultsA total of 4 191 global proteins, 1 640 phosphoproteins and 4 064 phosphosites were identified from 3 species of milk-derived exosomes, and the exosome proteins and phosphoproteins from different species were significantly higher than those of whey. Meanwhile, some special pathways were enriched like Fcγ-mediated phagocytosis from bovine exosomes, pathways related with neural and immune system from caprine exosomes, positive and negative regulation of multiple activities from porcine exosomes. ConclusionIn this study, the proteomic and phosphoproteomic analyses of exosomes and whey from bovine, porcine and caprine milk were carried out to reveal the difference of composition and related signaling pathways of milk exosome from different species. These results provided powerful support for the application of exosomes from different milk sources in the field of disease treatment.
10.Licorice-saponin A3 is a broad-spectrum inhibitor for COVID-19 by targeting viral spike and anti-inflammation
Yang YI ; Wenzhe LI ; Kefang LIU ; Heng XUE ; Rong YU ; Meng ZHANG ; Yang-Oujie BAO ; Xinyuan LAI ; Jingjing FAN ; Yuxi HUANG ; Jing WANG ; Xiaomeng SHI ; Junhua LI ; Hongping WEI ; Kuanhui XIANG ; Linjie LI ; Rong ZHANG ; Xin ZHAO ; Xue QIAO ; Hang YANG ; Min YE
Journal of Pharmaceutical Analysis 2024;14(1):115-127
Currently,human health due to corona virus disease 2019(COVID-19)pandemic has been seriously threatened.The coronavirus severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)spike(S)protein plays a crucial role in virus transmission and several S-based therapeutic approaches have been approved for the treatment of COVID-19.However,the efficacy is compromised by the SARS-CoV-2 evolvement and mutation.Here we report the SARS-CoV-2 S protein receptor-binding domain(RBD)inhibitor licorice-saponin A3(A3)could widely inhibit RBD of SARS-CoV-2 variants,including Beta,Delta,and Omicron BA.1,XBB and BQ1.1.Furthermore,A3 could potently inhibit SARS-CoV-2 Omicron virus in Vero E6 cells,with EC50 of 1.016 pM.The mechanism was related to binding with Y453 of RBD deter-mined by hydrogen-deuterium exchange mass spectrometry(HDX-MS)analysis combined with quan-tum mechanics/molecular mechanics(QM/MM)simulations.Interestingly,phosphoproteomics analysis and multi fluorescent immunohistochemistry(mIHC)respectively indicated that A3 also inhibits host inflammation by directly modulating the JNK and p38 mitogen-activated protein kinase(MAPK)path-ways and rebalancing the corresponding immune dysregulation.This work supports A3 as a promising broad-spectrum small molecule drug candidate for COVID-19.


Result Analysis
Print
Save
E-mail