1.Construction and application of a system for rational drug use for prescriptions from internet hospitals and external prescriptions and medical insurance fund control based on a pre-review prescription system
Yi GE ; Xiaolan WANG ; Junping HAN ; Bo LYU ; Yu GUAN ; Feng XU ; Aiming SHI
China Pharmacy 2026;37(5):584-588
OBJECTIVE To ensure the safety of patients’ drug use and control the risk of medical insurance expenditure by upgrading the pre-prescription review system to conduct pre-review on prescriptions from internet hospitals and external prescriptions, as well as to review the payment methods of drugs (including in-hospital and external drug dispensing). METHODS The data interfaces of prescriptions from internet hospitals and external prescriptions were integrated to achieve real-time rational drug use intervention. Additionally, an intelligent review project for payment method was added to precisely intervene in the medical insurance payment methods of drugs. The effect of the system upgrade was evaluated by comparing the qualification rates of prescriptions from internet hospitals and external prescriptions and the suspected amounts of drug violations from January to April 2025 (before the system upgrade) and May to August 2025 (after the system upgrade). RESULTS After the upgrade of the pre-prescription review system, the qualification rates of prescriptions from internet hospitals and external prescriptions increased by 3.5% [95% confidence interval (CI)=0.3%-6.7%, P =0.037 ] ; the suspected amounts of drug violations decreased to 52.9% of the pre-upgrade level (95%CI=31.6%-88.5%, P =0.026), and the average monthly sequential decrease was 29.5% (95%CI=12.2%-43.4%, P =0.012). Moreover, the addition of the intelligent review project for payment methods promoted the management of off-label drug use in our hospital. After the upgrade, a total of 79 filling valid applications for off-label drug use were received and archived. CONCLUSIONS The upgrade of the pre-prescription review system effectively improves the review qualification rates of prescriptions from internet hospitals and external prescriptions and the accuracy of medical insurance payment for drugs, and strengthens the supervision of off-label drug use, achieving dual guarantees of clinical rationality and medical insurance compliance.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Component Analysis of Anmeidan and Its Mechanism in Regulating ERK1/2/MNK/ELF4E Signaling Pathway to Improve Circadian Rhythm in Insomnia Rats
Yi GAO ; Bo XU ; Jing XIA ; Linlin CHEN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):44-53
ObjectiveTo identify the main chemical constituents of Anmeidan (AMD) and to explore the mechanism of AMD in regulating the extracellular signal-regulated kinase 1/2 (ERK1/2)/mitogen-activated protein kinase (MAPK)-interacting serine/threonine-protein kinase (MNK)/eukaryotic translation initiation factor 4E (eIF4E) signaling pathway to improve circadian rhythm disturbances in insomnia rats. MethodsThe main chemical constituents of AMD were identified using ultra-high-performance liquid chromatography-linear ion trap-electrostatic orbital trap mass spectrometry (UPLC-LTQ/Orbitrap/MS) in combination with reference standards. Sixty male Sprague-Dawley (SD) rats were randomly divided into control, model, melatonin, and AMD low-, medium-, and high-dose groups, with 10 rats in each group. Except for the control group, all rats were administered p-chlorophenylalanine via intraperitoneal injection to establish an insomnia model. The activity-rest rhythm of rats was assessed using the open field test and circadian rhythm test. Hematoxylin-eosin (HE) staining and Nissl staining were used to observe structural changes in hypothalamic neurons. Immunofluorescence, real-time quantitative polymerase chain reaction (Real-time PCR), and Western blot analysis were employed to detect mRNA and protein expression levels of ERK1/2, MNK, and eIF4E in the hypothalamus. ResultsA total of 50 chemical components, including flavonoids, phenylpropanoids, triterpenoid saponins, alkaloids, and lignans, were identified in AMD. Compared with the control group, the model group exhibited significantly increased total distance traveled, average speed, central area residence time, and cumulative rearing time (P<0.01), as well as prolonged cumulative activity time and total activity time in both light and dark phases (P<0.01). Hypothalamic neurons in the model group were sparsely arranged, reduced in number, and exhibited nuclear disappearance or nucleolar rupture, with a significantly increased apoptosis index (P<0.01). The cytoplasm appeared turbid, Nissl body staining was lighter, and the Nissl body apoptosis index was significantly increased (P<0.01). The mRNA expression levels of ERK1/2, MNK, and eIF4E were significantly decreased (P<0.01), along with a significant reduction in protein expression levels of ERK1/2, phosphorylated ERK1/2 (p-ERK1/2), MNK, phosphorylated MNK (p-MNK), eIF4E, and phosphorylated eIF4E (p-eIF4E) (P<0.01). Compared with the model group, the total distance, average speed, central area residence time and body upright cumulative time of the AMD high-dose group were significantly reduced (P<0.01). The total distance, average speed and body upright cumulative time of the AMD medium-dose group were significantly reduced (P<0.01). The cumulative time of light activity and total time of activity in each dose group of AMD were significantly shortened (P<0.01). The cumulative time of dark activity in the high-dose group of AMD was prolonged (P<0.01). The neurons in the middle and high dose groups of AMD were closely arranged, the number of neurons increased, and the apoptosis index of hypothalamic cells decreased significantly (P<0.05, P<0.01). The cytoplasm of the low, middle and high dose groups of AMD was clear, the color of Nissl body became darker, and the apoptosis index of Nissl body decreased significantly (P<0.01). The expression of ERK1/2, MNK and eIF4E mRNA and protein in the hypothalamus of the middle and high dose groups of AMD increased significantly (P<0.05, P<0.01). ConclusionAMD primarily contains 50 chemical constituents, including flavonoids, phenylpropanoids, and triterpenoid saponins. It exhibits a "synergistic enhancement" effect through multiple components and multiple pathways to improve insomnia. AMD ameliorates circadian rhythm disturbances in p-chlorophenylalanine-induced insomnia rats by upregulating ERK1/2/MNK/eIF4E signaling pathway-related proteins.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Multidisciplinary expert consensus on weight management for overweight and obese children and adolescents based on healthy lifestyle
HONG Ping, MA Yuguo, TAO Fangbiao, XU Yajun, ZHANG Qian, HU Liang, WEI Gaoxia, YANG Yuexin, QIAN Junwei, HOU Xiao, ZHANG Yimin, SUN Tingting, XI Bo, DONG Xiaosheng, MA Jun, SONG Yi, WANG Haijun, HE Gang, CHEN Runsen, LIU Jingmin, HUANG Zhijian, HU Guopeng, QIAN Jinghua, BAO Ke, LI Xuemei, ZHU Dan, FENG Junpeng, SHA Mo, Chinese Association for Student Nutrition & ; Health Promotion, Key Laboratory of Sports and Physical Fitness of the Ministry of Education,〖JZ〗 Engineering Research Center of Ministry of Education for Key Core Technical Integration System and Equipment,〖JZ〗 Key Laboratory of Exercise Rehabilitation Science of the Ministry of Education
Chinese Journal of School Health 2025;46(12):1673-1680
Abstract
In recent years, the prevalence of overweight and obesity among children and adolescents has risen rapidly, posing a serious threat to their physical and mental health. To provide scientific, systematic, and standardized weight management guidance for overweight and obese children and adolescents, the study focuses on the core concept of healthy lifestyle intervention, integrates multidisciplinary expert opinions and research findings,and proposes a comprehensive multidisciplinary intervention framework covering scientific exercise intervention, precise nutrition and diet, optimized sleep management, and standardized psychological support. It calls for the establishment of a multi agent collaborative management mechanism led by the government, implemented by families, fostered by schools, initiated by individuals, optimized by communities, reinforced by healthcare, and coordinated by multiple stakeholders. Emphasizing a child and adolescent centered approach, the consensus advocates for comprehensive, multi level, and personalized guidance strategies to promote the internalization and maintenance of a healthy lifestyle. It serves as a reference and provides recommendations for the effective prevention and control of overweight and obesity, and enhancing the health level of children and adolescents.
7.Application of early intermittent enteral nutrition combined with optimal management of blood glucose in patients with stress hyperglycemia after cardiac surgery
Run HUANG ; Min XU ; Hai-Bo ZHANG ; Yi-Lei ZHU
Parenteral & Enteral Nutrition 2025;32(1):29-34
Objective:To explore the application effect of early enteral nutrition combined with optimized blood glucose management in patients with stress hyperglycemia after cardiac surgery.Methods:A study was conducted to construct an early enteral nutrition and blood glucose optimization management plan for patients with stress hyperglycemia after cardiac surgery.A prospective analysis was conducted from May 2022 to May 2023 in the Cardiothoracic Surgery Intensive Care Unit(CICU)of a tertiary hospital in Shanghai.200 patients with stress hyperglycemia after cardiac surgery were divided into control group(n=100)and observation group(n=100)by random number table method.The control group received routine enteral nutrition and blood glucose management plan,while the observation group received early enteral nutrition combined with blood glucose optimization management plan.Nutrition related outcome indicators,blood glucose management quality indicators,and patient prognosis indicators were compared between two groups of patients.Results:After implementing the early enteral nutrition combined with optimized blood glucose management plan,the nutritional indicators(serum prealbumin,hemoglobin,and 7-day calorie compliance rate)of the observation group were higher than those of the control group,and the differences were statistically significant(P<0.05);The maximum blood glucose fluctuation amplitude,insulin use time,and incidence of hypoglycemia in the observation group were significantly lower than those in the control group(P<0.05),and the time within the glucose target range was significantly higher than that in the control group,with statistical significance(P<0.05);The mechanical ventilation time,ICU stay time,and total hospital stay in the observation group were significantly lower than those in the control group,and the differences were statistically significant(P<0.05).Conclusions:Early enteral nutrition combined with optimized blood glucose management can effectively improve the nutritional status of patients with stress hyperglycemia after cardiac surgery,reduce blood glucose fluctuations,improve blood glucose management quality,and promote patient outcomes and prognosis.
8.Screening of Illicit Oxyphenisatin Substances in Weight-Loss Dietary Supplements by High Performance Liquid Chromatography-in-Source-Fragmentation-Quadrupole Time-of-Flight Mass Spectrometry
Hong-Fei SHI ; Ke-Yu LIU ; Bo-Peng XU ; Cheng-Xin XU ; Xiu-Qi ZHOU ; Yi-Fei ZHOU ; Ming-Xin GUO
Chinese Journal of Analytical Chemistry 2025;53(9):1576-1585,后插1-后插9,封3
By summarizing the mass spectrometric fragmentation patterns of oxyphenisatin substances,an analytical method was established for screening of illegally added oxyphenisatin compounds in weight-loss health foods using high performance liquid chromatography-in-source-fragmentation-quadrupole time-of-flight mass spectrometry(HPLC-ISF-QTOF-MS),along with a quantitative method for 11 kinds of oxyphenisatin compounds.Based on the developed screening method,an oxyphenisatin derivative was discovered in the reference standards,which was tentatively identified as 4-(3-(4-hydroxyphenyl)-2-oxoindolin-3-yl)phenyl acetate and confirmed by MS/MS analysis.The results showed that all 11 kinds of oxyphenisatin compounds had correlation coefficients greater than 0.9971,with limits of detection(LODs)ranging from 0.12 to 0.68 μg/L and limits of quantification(LOQ)from 0.21 to 2.29 μg/L.The LODs for 11 kinds of characteristic ions ranged from 0.45 to 9.11 μg/kg.At spiking levels of 25,50 and 100 μg/kg,the recoveries ranged from 78.9%to 117.3%.The instrumental precision,intra-day method precision and inter-day method precision were 0.23%?1.70%,0.7%?2.4%,and 1.1%?3.3%,respectively.The developed targeted and non-targeted detection method demonstrated high sensitivity,strong stability,rapid analysis,and an expanded screening range for oxyphenisatin substances,and provided robust technical support for regulatory authorities in combating illegal adulteration.
9.Association of digit ratio with polymorphisms at three loci of matrix metalloproteinase 9 gene in Ningxia Han youths
Meng-Yi YANG ; Jin ZHANG ; Shi-Bo NIU ; Jie DANG ; Zhan-Bing MA ; Hong LU ; Zheng-Hao HUO ; Yu XU ; Dan SHEN
Acta Anatomica Sinica 2025;56(1):74-79
Objective To investigate the association of digit ratio with single nucleotide polymorphism(SNP)at three loci(rs17576,rs3918249,rs9509)of matrix metallopeptidase 9(MMP-9)gene.Methods A total of 804 Ningxia Han youths(399 males and 405 females)were used as the study subjects.A digital camera was used to take frontal photographs of the hands,and image analysis software was used to mark the anatomical points and measure the lengths of each finger of both hands(2D,3D,4D,5D);Multiplexed PCR was used to detect the three polymorphic sites of the MMP-9 gene,SPSS 25.0 and R Studio software were used for data analysis and plotting.Results The 2D/3D(P<0.05)and 2D/4D(left,P<0.01,right,P<0.05)of both hands,2D/5D(P<0.01),3D/5D,4D/5D(P<0.05)of the right hand,and 3D/4D(P<0.05)of the left hand in female youths of Ningxia Han were significantly higher than those in males,Differences in genotypes and allele frequencies at all 3 loci of the MMP-9 gene were not statistically significant between genders(P>0.05).Right hand 2D/4D was significantly associated with genotypes at the rs17576 and rs3918249 loci in male youths(P<0.05).Conclusion MMP-9 gene SNPs(rs17576 and rs3918249)may be associated with the formation of 2D/4D of Ningxia Han male youths.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.


Result Analysis
Print
Save
E-mail