1.Behavioral characterization of olfactory, auditory, and motor deficits in 5×FAD mice
Hyewon JANG ; Sueun LEE ; Yeongjun KIM ; Jeongmin LEE ; Jong-Choon KIM ; Joong-Sun KIM ; Jong-Hwan PARK ; Jinwook KIM ; Yeonghoon SON ; Changjong MOON
Journal of Veterinary Science 2026;27(3):e35-
Objective:
To characterize age-related motor, olfactory, and auditory changes in 5×FAD mice and assess associated AD pathologies and neuroinflammation in relevant brain regions.
Methods:
5×FAD and control mice were tested at 3, 6, and 12 months. Locomotor activity and motor coordination were assessed using the open field and rotarod tests, respectively. Olfactory and auditory performance were evaluated using the buried food test and the acoustic startle response test, respectively. Amyloid-β pathology and glial activation were examined in relevant nervous system components using western blot and immunohistochemistry analyses.
Results:
5×FAD mice showed no differences in open-field locomotion at any age, but exhibited a significantly greater passive clinging duration at 12 months compared to wild-type controls (p < 0.001). In the buried food test, olfactory latency was significantly prolonged in 5×FAD mice at 6 months (p = 0.035) and 12 months (p < 0.001). Acoustic startle amplitude was significantly reduced at 6 months (p = 0.030) and 12 months (p = 0.007). Amyloid-β and p-Tau accumulation and glial activation were elevated in the olfactory bulb and auditory cortex in an age-dependent manner.
Conclusions
and Relevance: This study provides an age-related behavioral and pathological characterization of olfactory and auditory impairments in the 5×FAD mouse model, with motor measures included as complementary assessments. Our findings broaden the spectrum of functional deficits associated with the AD pathology in this model.
2.Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT.
Samin HONG ; Yeongjun KIM ; Jongwoo SHIM ; Chan Yun KIM ; Gong Je SEONG
Korean Journal of Ophthalmology 2011;25(2):105-109
PURPOSE: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. METHODS: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 x 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach's alpha (alpha), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. RESULTS: The mean age of the participants was 25.82 +/- 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (alpha, 0.940; ICC, 0.945; COV, 2.45 +/- 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (alpha, 0.715; ICC, 0.716; COV, 5.72 +/- 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. CONCLUSIONS: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.
Adult
;
*Algorithms
;
Female
;
Humans
;
Male
;
Observer Variation
;
Optic Nerve Diseases/*diagnosis
;
Retinal Ganglion Cells/*pathology
;
Tomography, Optical Coherence/methods/*statistics & numerical data
;
Young Adult
3.Immediate and Long Term Outcome of Single Long Stent for Long Complex Coronary Artery Stenosis Compared to Multiple Conventional Stent..
Dongkyu JIN ; Yunjeong LEE ; Hwaeun LEE ; Wonho JUNG ; Yeongjun KIM ; Sejin OH ; Minsoo SON ; Jiwon SON ; Taehoon AHN ; Insuk CHOI ; Eakkyun SHIN
Korean Circulation Journal 1998;28(9):1465-1472
Coronary stenting for long complex lesion is effective but associated with complication. We compared the results of stenting between with multiple conventional stenting group (group A) and with single long stenting group (group B). Fifty patients were prospectively and randomly enrolled: 25 patients for each group. Each group showed no significant differences of clinical characteristics. One patient died of heart failure in each group, not associated with the procedure itself. One patients had cerebrovascular accident in each group. Five patients had major bleeding (2, group A; 3, group B). Angiographic success rate was 100% in each group and procedural success rate was 96% and 100% in group A and B, respectively. Angiographic and clinical restenosis rate at 6 months follow-up were 60%, 36% in group A and 65%, 44% in group B, respectively (p=S). Multivariate analysis showed that several factors affected the angiographic restenosis rate as follows; a) male gender (M:F=76.9%:25.0%, P<0.001), b) AMI (AMI:stable angina pectoris=72.7%:66.7%, P<0.001), c) lesion length d) residual stenosis. In conclusion, there were no statistical differences of restenosis and complication rate between the two groups. Our data support single long stenting is acceptable and economically more favorable for long diffuse lesion, compared to multiple conventional stenting.
Constriction, Pathologic
;
Coronary Stenosis*
;
Coronary Vessels*
;
Follow-Up Studies
;
Heart Failure
;
Hemorrhage
;
Humans
;
Male
;
Multivariate Analysis
;
Prospective Studies
;
Stents*
;
Stroke

Result Analysis
Print
Save
E-mail