1.A Male With Preserved Prepubertal Voice Characteristics: A Case Report on Mutational Dysphonia
Bo Yun CHOI ; Oh-Hyeong LEE ; Sang-Yeon KIM ; Dong-Il SUN
Journal of the Korean Society of Laryngology Phoniatrics and Logopedics 2025;36(1):26-31
Mutational dysphonia, a condition in which a pre-adolescent voice persists into adulthood, can significantly impact personal and professional life but is treatable with voice therapy. A patient with mutational dysphonia usually has a voice that is weak, breathy, or diplophonic, often classified as a “falsetto” voice. In this case report, we present a 20-year-old male who had a typical voice of a boy before adolescence, making it difficult to diagnose as mutational dysphonia. After voice therapy, he successfully gained his post-adolescent voice, highlighting the importance of thorough diagnosis and personalized treatment for mutational dysphonia.
2.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
3.Development of the Korean Version of the Meaning in Life Scale for Cancer Patients
Namgu KANG ; Hae-Yeon YUN ; Young Ae KIM ; Hye Yoon PARK ; Jong-Heun KIM ; Sun Mi KIM ; Eun-Seung YU
Psychiatry Investigation 2025;22(3):258-266
Objective:
This study aims to understand the structure of meaning in life among patients with cancer through the validation of the Meaning in Life Scale among Korean patients (K-MiLS) with cancer.
Methods:
From August 2021 to November 2022, participants were recruited from multiple sites in South Korea. Participants completed related questionnaires, including the MiLS, on the web or mobile. Test-retest reliability was assessed between 2 and 4 weeks after the initial assessment. Exploratory and confirmatory factor analyses and Pearson’s correlations were used to evaluate the reliability and validity of the MiLS. A multiple regression analysis was conducted to examine the sociodemographic and disease-related variables correlated with the MiLS. Regarding concurrent validity, a hierarchical regression analysis was performed.
Results:
The results (n=345) indicated that the K-MiLS has a four-factor structure: Harmony and Peace; Life Perspective, Purpose, and Goals; Confusion and Lessened Meaning; and Benefits of Spirituality. Regarding convergent and discriminant validity, K-MiLS was negatively correlated with Patient Health Questionnaire-9, Generalized Anxiety Disorder-7, and Fear of Cancer Recurrence Inventory while showing a significantly positive correlation with the Posttraumatic Growth Inventory, Self-Compassion Scale, Functional Assessment of Cancer Therapy-General, and Functional Social Support Questionnaire. Hierarchical regression analysis revealed that the demographic variable influencing MiLS was religious affiliation.
Conclusion
The K-MiLS had a multidimensional four-factor structure similar to that of the original version. It is also a reliable and valid measure for assessing cancer survivors’ meaning in life after a cancer diagnosis.
4.Clinical Utility of Monitoring Circulating Tumor DNA Using a Targeted Next-generation Sequencing Panel in Patients with Colorectal Cancer
Hyoeun SHIM ; Soobeen HEO ; Jiyu SUN ; Moon Ki CHOI ; Sung Chan PARK ; Chang Won HONG ; Seong Hoon KIM ; Seog-Yun PARK ; Sun-Young KONG ; Ji Yeon BAEK
Annals of Laboratory Medicine 2025;45(4):450-458
Background:
Circulating tumor DNA (ctDNA) profiling from peripheral blood allows relatively noninvasive monitoring of solid tumors; however, its utility post-surgery or chemotherapy in colorectal cancer remains underexplored. We evaluated the clinical implications of a ctDNA next-generation sequencing (NGS) panel post-surgery or chemotherapy in patients with colorectal cancer.
Methods:
We collected samples from 23 patients with colorectal cancer (17 men, median age 65 yrs) at baseline and post-surgery or chemotherapy at the National Cancer Center, Korea, between January 2021 and September 2023. ctDNA was analyzed using an NGS panel including 46 genes, and variant allele frequencies (VAFs) were determined. Followup samples were analyzed using the NGS panel or droplet digital PCR (ddPCR) when probes were available. Clinical status was compared with ctDNA results, and survival was analyzed using a time-dependent Cox model.
Results:
Mutations were identified in 13 out of 14 patients (92.8%) with stage II/III cancer and in all nine patients (100%) with stage IV cancer. Mutations were detected in KRAS (N = 15, 65%), APC (N = 8, 35%), TP53 (N = 7, 30%), PIK3CA (N = 5, 22%), and RET (N = 4, 17%). A 1% increase in KRAS and TP53 VAFs was associated with 48% and 32% increased mortality risk, respectively. Changes in VAF correlated well with clinical findings.
Conclusions
The detection of and an increase in KRAS and TP53 VAFs were associated with poor prognosis. ddPCR-based ctDNA monitoring results were comparable to those obtained with the NGS panel. ctDNA monitoring during treatment is clinically informative in managing colorectal cancer.
5.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
6.Development of the Korean Version of the Meaning in Life Scale for Cancer Patients
Namgu KANG ; Hae-Yeon YUN ; Young Ae KIM ; Hye Yoon PARK ; Jong-Heun KIM ; Sun Mi KIM ; Eun-Seung YU
Psychiatry Investigation 2025;22(3):258-266
Objective:
This study aims to understand the structure of meaning in life among patients with cancer through the validation of the Meaning in Life Scale among Korean patients (K-MiLS) with cancer.
Methods:
From August 2021 to November 2022, participants were recruited from multiple sites in South Korea. Participants completed related questionnaires, including the MiLS, on the web or mobile. Test-retest reliability was assessed between 2 and 4 weeks after the initial assessment. Exploratory and confirmatory factor analyses and Pearson’s correlations were used to evaluate the reliability and validity of the MiLS. A multiple regression analysis was conducted to examine the sociodemographic and disease-related variables correlated with the MiLS. Regarding concurrent validity, a hierarchical regression analysis was performed.
Results:
The results (n=345) indicated that the K-MiLS has a four-factor structure: Harmony and Peace; Life Perspective, Purpose, and Goals; Confusion and Lessened Meaning; and Benefits of Spirituality. Regarding convergent and discriminant validity, K-MiLS was negatively correlated with Patient Health Questionnaire-9, Generalized Anxiety Disorder-7, and Fear of Cancer Recurrence Inventory while showing a significantly positive correlation with the Posttraumatic Growth Inventory, Self-Compassion Scale, Functional Assessment of Cancer Therapy-General, and Functional Social Support Questionnaire. Hierarchical regression analysis revealed that the demographic variable influencing MiLS was religious affiliation.
Conclusion
The K-MiLS had a multidimensional four-factor structure similar to that of the original version. It is also a reliable and valid measure for assessing cancer survivors’ meaning in life after a cancer diagnosis.
7.Breast cancer implant reconstructive surgery and radiotherapy: a retrospective analysis of medical records
Ji Young YUN ; Ki Jung AHN ; Hyunjung KIM ; Hee Yeon KIM ; Tae Hyun KIM ; Kyung Do BYUN ; Ji Sun PARK ; Yunseon CHOI
Annals of Surgical Treatment and Research 2025;108(5):295-301
Purpose:
This study aimed to analyze whether the occurrence of complications increases if radiotherapy (RT) is administered after breast reconstructive surgery using implants.
Methods:
This retrospective study included 80 patients who underwent breast reconstruction using implants, of which 16 (20.0%) underwent RT. Most patients underwent conventional fractionated RT (n = 13), and hypofractionated RT was performed in 3 patients. Most patients (n = 51, 63.8%) underwent delayed reconstruction, which involved implant replacement after tissue expander insertion. Only 29 patients (36.3%) underwent immediate reconstruction simultaneously with breast cancer surgery.
Results:
The median postoperative follow-up was 39.9 months (range, 8.7–120.3 months). Complications occurred in 18 (22.5%); infectionecrosis (n = 8), leakage/rupture (n = 8), and capsular contracture (n = 2). Infectionecrosis is common in patients undergoing RT. Complications occurred in 4 patients (25.0%) who received RT and 14 (21.9%) who did not receive RT, and complications did not significantly increase with RT (P = 0.511). There was no overall difference in complications between the immediate (4 of 29) and delayed (14 of 51) reconstruction groups (P = 0.129). Nine patients underwent reoperation because of complications; 3 (18.8%) received RT and 6 (9.4%) did not receive RT. The reoperation rate did not increase significantly with RT (P = 0.254). There were 3 cases of recurrence, and patients who received RT had no recurrence.
Conclusion
RT did not significantly increase the complication or reoperation rates if reconstructive surgery was performed using implants. Therefore, RT should be performed in patients at a high risk of recurrence.
8.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
9.Development of the Korean Version of the Meaning in Life Scale for Cancer Patients
Namgu KANG ; Hae-Yeon YUN ; Young Ae KIM ; Hye Yoon PARK ; Jong-Heun KIM ; Sun Mi KIM ; Eun-Seung YU
Psychiatry Investigation 2025;22(3):258-266
Objective:
This study aims to understand the structure of meaning in life among patients with cancer through the validation of the Meaning in Life Scale among Korean patients (K-MiLS) with cancer.
Methods:
From August 2021 to November 2022, participants were recruited from multiple sites in South Korea. Participants completed related questionnaires, including the MiLS, on the web or mobile. Test-retest reliability was assessed between 2 and 4 weeks after the initial assessment. Exploratory and confirmatory factor analyses and Pearson’s correlations were used to evaluate the reliability and validity of the MiLS. A multiple regression analysis was conducted to examine the sociodemographic and disease-related variables correlated with the MiLS. Regarding concurrent validity, a hierarchical regression analysis was performed.
Results:
The results (n=345) indicated that the K-MiLS has a four-factor structure: Harmony and Peace; Life Perspective, Purpose, and Goals; Confusion and Lessened Meaning; and Benefits of Spirituality. Regarding convergent and discriminant validity, K-MiLS was negatively correlated with Patient Health Questionnaire-9, Generalized Anxiety Disorder-7, and Fear of Cancer Recurrence Inventory while showing a significantly positive correlation with the Posttraumatic Growth Inventory, Self-Compassion Scale, Functional Assessment of Cancer Therapy-General, and Functional Social Support Questionnaire. Hierarchical regression analysis revealed that the demographic variable influencing MiLS was religious affiliation.
Conclusion
The K-MiLS had a multidimensional four-factor structure similar to that of the original version. It is also a reliable and valid measure for assessing cancer survivors’ meaning in life after a cancer diagnosis.
10.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.

Result Analysis
Print
Save
E-mail