1.Assessing Laser Safety in Dermatology:Eye Protection and Infection Control Practices Among Board-Certified Korean Dermatologists
Sejin OH ; Yeong Ho KIM ; Bo Ri KIM ; Hyun-Min SEO ; Soon-Hyo KWON ; Hoon CHOI ; Hae Woong LEE ; Jung-Im NA ; Chun Pill CHOI ; Joo Yeon KO ; Hwa Jung RYU ; Suk Bae SEO ; Jong Hee LEE ; Chang-Hun HUH ; Hei Sung KIM
Annals of Dermatology 2026;38(1):69-74
Background:
Laser procedures are integral to dermatologic practice, yet safety measures- particularly regarding ocular protection and plume control- are poorly studied in real-world settings.
Objective:
To evaluate current practices in eye protection, infection control, and occupational risk awareness among Korean dermatologists performing laser treatments.
Methods:
A cross-sectional survey was conducted among board-certified dermatologists at the 2024 Korean Society for Dermatologic Laser Surgery meeting. The questionnaire covered demographics, laser frequency, use of goggles and masks, infection control strategies, ophthalmologic monitoring, and history of warts or cancer.
Results:
Seventy-nine respondents completed the survey. All reported using protective goggles, but only 26.6% and 22.8% did so for CO 2 and erbium-doped yttrium aluminium garnet lasers, respectively. Only 24.1% underwent regular eye exams, and 13.9% reported eye conditions after starting laser practice. While 89.9% used masks, 40.8% used dental masks, which are inadequate for plume protection. Suction devices were used by 94.9%, though performance specifications were unclear. Warts were reported by 46.8% of respondents; two reported cancer diagnoses after initiating laser work.
Conclusion
Despite high overall adherence to basic safety practices, critical gaps remain. Our findings highlight the need for standardized guidelines and long-term occupational health monitoring to ensure safe laser practice.
2.Current Clinical Perspectives on Rosacea Management: Insights From a Korean Multicenter Expert Opinion Survey
Bo Ri KIM ; Sejin OH ; Ju Hee HAN ; Jimyung SEO ; Hyun-Min SEO ; Soon-Hyo KWON ; Hoon CHOI ; Jung U SHIN ; Jae We CHO ; Boncheol Leo GOO ; Jung-Im NA ; Dong Hun LEE ; Chun Pill CHOI ; HaeWoong LEE ; Joo Yeon KO ; Hwa Jung RYU ; Nark-Kyoung RHO ; Hyunjo KIM ; Ga-Young LEE ; Jong Hee LEE ; Nala SHIN ; Sang Ju LEE ; Suk Bae SEO ; Geun Soo LEE ; Hei Sung KIM ; Chang-Hun HUH
Annals of Dermatology 2026;38(1):42-50
Background:
Rosacea is a chronic inflammatory skin disorder characterized by erythema, papules, ocular symptoms, and heightened sensitivity. Patients with neurogenic symptoms such as burning or stinging remain particularly difficult to manage. Current guidelines often underrepresent energy-based devices (EBDs), pigmentary sequelae, psychosocial burden, and ocular comorbidities.
Objective:
To examine Korean dermatologists’ expert perspectives on rosacea management, focusing on skin sensitivity, neurogenic symptoms, pigmentary changes, psychosocial impact, ocular involvement, and EBD use.
Methods:
A web-based, 29-item survey was administered to 25 board-certified Korean dermatologists (May–June 2025). Quantitative and qualitative responses were analyzed.
Results:
Erythematotelangiectatic and papulopustular phenotypes with sensitivity skin predominated. EBDs (pulsed dye laser, intense pulsed light) were frequently used but limited by cost and sensitivity issues. Neurogenic symptoms were recognized but rarely treated with neuromodulators. Post-inflammatory hyperpigmentation was infrequent, yet monitoring was inconsistent.Psychosocial and ocular aspects were acknowledged but seldomly systematically addressed.Respondents expressed interest in emerging adjunctive treatments such as cold plasma, skin boosters, and holistic care approaches.
Conclusion
Korean dermatologists adopt individualized strategies for rosacea, yet practice gaps remain regarding neurogenic symptoms, pigmentary complications, and psychosocial and ocular comorbidities. Findings support the need for updated multidisciplinary, phenotype-driven guidelines aligned with real-world practice.
3.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
4.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
5.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
6.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
7.Real-World Clinical Practice on Skin Rejuvenation Among Korean BoardCertified Dermatologists: SurveyBased Results
Sejin OH ; Yeong Ho KIM ; Bo Ri KIM ; Hyun-Min SEO ; Soon-Hyo KWON ; Hoon CHOI ; Haewoong LEE ; Jung-Im NA ; Chun Pill CHOI ; Joo Yeon KO ; Hwa Jung RYU ; Suk Bae SEO ; Jong Hee LEE ; Hei Sung KIM ; Chang-Hun HUH
Annals of Dermatology 2025;37(3):123-130
Background:
Skin rejuvenation has become an increasingly popular noninvasive approach to address age-related changes such as sagging, wrinkles, and skin laxity. Energy-based devices (EBDs) and injectables are widely used, but their application requires careful customization based on individual patient characteristics to optimize outcomes and minimize potential adverse effects.
Objective:
This study aimed to explore clinical practice patterns among board-certified dermatologists in South Korea, focusing on their strategies for tailoring skin rejuvenation treatments to individual patients, including the integration of EBDs, injectables, and senotherapeutics.
Methods:
A structured survey comprising 10 questions was administered to 13 experienced dermatologists specializing in skin rejuvenation. The survey covered treatment strategies for patients with varying facial fat volumes, pain management approaches, and the use of EBDs, injectables and senotherapeutics.
Results:
High-intensity focused ultrasound (HIFU) and radiofrequency (RF) were the most employed EBDs, often combined with injectables for enhanced outcomes. For patients with higher facial fat, HIFU and deoxycholic acid injections were preferred for contouring and tightening. For those with lower facial fat, biostimulatory agents such as poly-D, L-lactic acid and microneedle RF were favored to restore volume and elasticity. Pain management strategies included topical anesthetics and stepwise protocols. Although less commonly used, senotherapeutics were occasionally prescribed for specific conditions, such as melasma and extensive photoaging.
Conclusion
Dermatologists in South Korea employ a variety of patient-specific strategies for skin rejuvenation, combining various EBDs, injectables, and senotherapeutics. These findings highlight the importance of personalized treatment protocols and the need for further research to optimize treatment efficacy and safety.
8.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
9.Respiratory Syncytial Virus Outbreak Without Influenza in the Second Year of the Coronavirus Disease 2019 Pandemic: A National Sentinel Surveillance in Korea, 2021–2022 Season
Jong-Hun KIM ; Ha Yan KIM ; Myeongjee LEE ; Jong Gyun AHN ; Jee Yeon BAEK ; Min Young KIM ; Kyungmin HUH ; Jaehun JUNG ; Ji-Man KANG
Journal of Korean Medical Science 2022;37(34):e258-
Background:
This study aimed to investigate whether respiratory syncytial virus (RSV) and influenza virus (IFV) infections would occur in 2021–2022 as domestic nonpharmaceutical interventions (NPIs) are easing.
Methods:
Data were collected from the Korean Influenza and Respiratory Virus Monitoring System database. The weekly positivity rates of respiratory viruses and number of hospitalizations for acute respiratory infections were evaluated (January 2016–2022).The period from February 2020 to January 2022 was considered the NPI period. The autoregressive integrated moving average model and Poisson analysis were used for data analysis. Data from 14 countries/regions that reported positivity rates of RSV and IFV were also investigated.
Results:
Compared with the pre-NPI period, the positivity and hospitalization rates for IFV infection during 2021–2022 significantly decreased to 0.0% and 1.0%, respectively, at 0.0% and 1.2% of the predicted values, respectively. The RSV infection positivity rate in 2021–2022 was 1.8-fold higher than that in the pre-NPI period at 1.5-fold the predicted value. The hospitalization rate for RSV was 20.0% of that in the pre-NPI period at 17.6% of the predicted value. The re-emergence of RSV and IFV infections during 2020–2021 was observed in 13 and 4 countries, respectively.
Conclusion
During 2021–2022, endemic transmission of the RSV, but not IFV, was observed in Korea.
10.Compare the Intracranial Pressure Trend after the Decompressive Craniectomy between Massive Intracerebral Hemorrhagic and Major Ischemic Stroke Patients
Joon HUH ; Seo Yeon YANG ; Han Yong HUH ; Jae Kun AHN ; Kwang Wook CHO ; Young Woo KIM ; Sung Lim KIM ; Jong Tae KIM ; Do Sung YOO ; Hae Kwan PARK ; Cheol JI
Journal of Korean Neurosurgical Society 2018;61(1):42-50
OBJECTIVE: Massive intracerebral hemorrhage (ICH) and major infarction (MI) are devastating cerebral vascular diseases. Decompression craniectomy (DC) is a common treatment approach for these diseases and acceptable clinical results have been reported. Author experienced the postoperative intracranaial pressure (ICP) trend is somewhat different between the ICH and MI patients. In this study, we compare the ICP trend following DC and evaluate the clinical significance.METHODS: One hundred forty-three patients who underwent DC following massive ICH (81 cases) or MI (62 cases) were analyzed retrospectively. The mean age was 56.3±14.3 (median=57, male : female=89 : 54). DC was applied using consistent criteria in both diseases patients; Glasgow coma scale (GCS) score less than 8 and a midline shift more than 6 mm on brain computed tomography. In all patients, ventricular puncture was done before the DC and ICP trends were monitored during and after the surgery. Outcome comparisons included the ictus to operation time (OP-time), postoperative ICP trend, favorable outcomes and mortality.RESULTS: Initial GCS (p=0.364) and initial ventricular ICP (p=0.783) were similar among the ICH and MI patients. The postoperative ICP of ICH patients were drop rapidly and maintained within physiological range if greater than 80% of the hematoma was removed. While in MI patients, the postoperative ICP were not drop rapidly and maintained above the physiologic range (MI=18.8 vs. ICH=13.6 mmHg, p=0.000). The OP-times were faster in ICH patients (ICH=7.3 vs. MI=40.9 hours, p=0.000) and the mortality rate was higher in MI patients (MI=37.1% vs. ICH=17.3%, p=0.007).CONCLUSION: The results of this study suggest that if greater than 80% of the hematoma was removed in ICH patients, the postoperative ICP rarely over the physiologic range. But in MI patients, the postoperative ICP was above the physiologic range for several days after the DC. Authors propose that DC is no need for the massive ICH patient if a significant portion of their hematoma is removed. But DC might be essential to improve the MI patients’ outcome and timely treatment decision.
Brain
;
Cerebral Hemorrhage
;
Cerebral Infarction
;
Decompression
;
Decompressive Craniectomy
;
Glasgow Coma Scale
;
Hematoma
;
Humans
;
Infarction
;
Intracranial Hemorrhages
;
Intracranial Pressure
;
Male
;
Mortality
;
Punctures
;
Retrospective Studies
;
Stroke
;
Vascular Diseases

Result Analysis
Print
Save
E-mail