1.Impact of Donor Age on Liver Transplant Outcomes in Patients with Acute-on-Chronic Liver Failure: A Cohort Study
Jie ZHOU ; Danni YE ; Shenli REN ; Jiawei DING ; Tao ZHANG ; Siyao ZHANG ; Zheng CHEN ; Fangshen XU ; Yu ZHANG ; Huilin ZHENG ; Zhenhua HU
Gut and Liver 2025;19(3):398-409
Background/Aims:
Liver transplantation is the most effective treatment for the sickest patients with acute-on-chronic liver failure (ACLF). However, the influence of donor age on liver transplantation, especially in ACLF patients, is still unclear.
Methods:
In this study, we used the data of the Scientific Registry of Transplant Recipients. We included patients with ACLF who received liver transplantation from January 1, 2007, to December 31, 2017, and the total number was 13,857. We allocated the ACLF recipients by age intogroup I (donor age ≤17 years, n=647); group II (donor age 18–59 years, n=11,423); and group III (donor age ≥60 years, n=1,787). Overall survival (OS), graft survival, and mortality were com-pared among the three age groups and the four ACLF grades. Cox regression was also analyzed.
Results:
The 1-, 3-, and 5-year OS rates were 89.6%, 85.5%, and 82.0% in group I; 89.4%, 83.4%, and 78.2% in group II; and 86.8%, 78.4%, and 71.4% in group III, respectively (p<0.001).When we analyzed the different effects of donor age on OS with different ACLF grades, in groupsII and III, we observed statistical differences. Finally, the cubic spline curve told us that the relative death rate changed linearly with increasing donor age.
Conclusions
Donor age is related to OS and graft survival of ACLF patients after transplanta-tion, and poorer results were associated with elderly donors. In addition, different donor ages have different effects on recipients with different ACLF grades.
2.Impact of Donor Age on Liver Transplant Outcomes in Patients with Acute-on-Chronic Liver Failure: A Cohort Study
Jie ZHOU ; Danni YE ; Shenli REN ; Jiawei DING ; Tao ZHANG ; Siyao ZHANG ; Zheng CHEN ; Fangshen XU ; Yu ZHANG ; Huilin ZHENG ; Zhenhua HU
Gut and Liver 2025;19(3):398-409
Background/Aims:
Liver transplantation is the most effective treatment for the sickest patients with acute-on-chronic liver failure (ACLF). However, the influence of donor age on liver transplantation, especially in ACLF patients, is still unclear.
Methods:
In this study, we used the data of the Scientific Registry of Transplant Recipients. We included patients with ACLF who received liver transplantation from January 1, 2007, to December 31, 2017, and the total number was 13,857. We allocated the ACLF recipients by age intogroup I (donor age ≤17 years, n=647); group II (donor age 18–59 years, n=11,423); and group III (donor age ≥60 years, n=1,787). Overall survival (OS), graft survival, and mortality were com-pared among the three age groups and the four ACLF grades. Cox regression was also analyzed.
Results:
The 1-, 3-, and 5-year OS rates were 89.6%, 85.5%, and 82.0% in group I; 89.4%, 83.4%, and 78.2% in group II; and 86.8%, 78.4%, and 71.4% in group III, respectively (p<0.001).When we analyzed the different effects of donor age on OS with different ACLF grades, in groupsII and III, we observed statistical differences. Finally, the cubic spline curve told us that the relative death rate changed linearly with increasing donor age.
Conclusions
Donor age is related to OS and graft survival of ACLF patients after transplanta-tion, and poorer results were associated with elderly donors. In addition, different donor ages have different effects on recipients with different ACLF grades.
3.Impact of Donor Age on Liver Transplant Outcomes in Patients with Acute-on-Chronic Liver Failure: A Cohort Study
Jie ZHOU ; Danni YE ; Shenli REN ; Jiawei DING ; Tao ZHANG ; Siyao ZHANG ; Zheng CHEN ; Fangshen XU ; Yu ZHANG ; Huilin ZHENG ; Zhenhua HU
Gut and Liver 2025;19(3):398-409
Background/Aims:
Liver transplantation is the most effective treatment for the sickest patients with acute-on-chronic liver failure (ACLF). However, the influence of donor age on liver transplantation, especially in ACLF patients, is still unclear.
Methods:
In this study, we used the data of the Scientific Registry of Transplant Recipients. We included patients with ACLF who received liver transplantation from January 1, 2007, to December 31, 2017, and the total number was 13,857. We allocated the ACLF recipients by age intogroup I (donor age ≤17 years, n=647); group II (donor age 18–59 years, n=11,423); and group III (donor age ≥60 years, n=1,787). Overall survival (OS), graft survival, and mortality were com-pared among the three age groups and the four ACLF grades. Cox regression was also analyzed.
Results:
The 1-, 3-, and 5-year OS rates were 89.6%, 85.5%, and 82.0% in group I; 89.4%, 83.4%, and 78.2% in group II; and 86.8%, 78.4%, and 71.4% in group III, respectively (p<0.001).When we analyzed the different effects of donor age on OS with different ACLF grades, in groupsII and III, we observed statistical differences. Finally, the cubic spline curve told us that the relative death rate changed linearly with increasing donor age.
Conclusions
Donor age is related to OS and graft survival of ACLF patients after transplanta-tion, and poorer results were associated with elderly donors. In addition, different donor ages have different effects on recipients with different ACLF grades.
4.Impact of Donor Age on Liver Transplant Outcomes in Patients with Acute-on-Chronic Liver Failure: A Cohort Study
Jie ZHOU ; Danni YE ; Shenli REN ; Jiawei DING ; Tao ZHANG ; Siyao ZHANG ; Zheng CHEN ; Fangshen XU ; Yu ZHANG ; Huilin ZHENG ; Zhenhua HU
Gut and Liver 2025;19(3):398-409
Background/Aims:
Liver transplantation is the most effective treatment for the sickest patients with acute-on-chronic liver failure (ACLF). However, the influence of donor age on liver transplantation, especially in ACLF patients, is still unclear.
Methods:
In this study, we used the data of the Scientific Registry of Transplant Recipients. We included patients with ACLF who received liver transplantation from January 1, 2007, to December 31, 2017, and the total number was 13,857. We allocated the ACLF recipients by age intogroup I (donor age ≤17 years, n=647); group II (donor age 18–59 years, n=11,423); and group III (donor age ≥60 years, n=1,787). Overall survival (OS), graft survival, and mortality were com-pared among the three age groups and the four ACLF grades. Cox regression was also analyzed.
Results:
The 1-, 3-, and 5-year OS rates were 89.6%, 85.5%, and 82.0% in group I; 89.4%, 83.4%, and 78.2% in group II; and 86.8%, 78.4%, and 71.4% in group III, respectively (p<0.001).When we analyzed the different effects of donor age on OS with different ACLF grades, in groupsII and III, we observed statistical differences. Finally, the cubic spline curve told us that the relative death rate changed linearly with increasing donor age.
Conclusions
Donor age is related to OS and graft survival of ACLF patients after transplanta-tion, and poorer results were associated with elderly donors. In addition, different donor ages have different effects on recipients with different ACLF grades.
5.Design and implementation of low-code platform for data services
Ren-Xin DING ; Tao ZHENG ; Mi-Ye WANG ; Qing-Ke SHI
Chinese Medical Equipment Journal 2024;45(4):13-19
Objective To design a low-code platform for data services to reduce the data interface service development costs and improve the development efficiency.Methods The platform was developed with Browser/Server(B/S)architecture,which used JAVA Spring Boot as its main framework and MySQL as the backend database system and had the functions for data source management,service catalog management,service management,service testing,service release management and service subscription management.Results The platform decreased the costs for interface development,operation and maintenance,lowered the technical threshold of interface development,unified the interface standard and enhanced hospital data security.Conclusion The platform developed provides support for hospital data interface service,digitalization and data services.[Chinese Medical Equipment Journal,2024,45(4):13-19]
6.Design and application of clinical disease database system based on post-structured technology
Nan LI ; Mi-Ye WANG ; Tao ZHENG ; Yan-Sheng LI ; Da-Peng JIANG ; Yong HUANG
Chinese Medical Equipment Journal 2024;45(4):20-26
Objective To design a post-structured technology-based clinical disease database system to solve the problems of the traditional disease database system in dependence on manual judgment,lack of auxiliary annotation and poor availability of electronic medical record data.Methods An entity recognition model was constructed with I2B2 standard and bi-directional long short-term memory(BiLSTM)model to form a medical record template library,and some relational templates were generated and complex medical entities were extracted to realize post-structuring of electronic medical records.Then a clinical disease database system was established based on the post-structured electronic medical record technology,which was composed of the modules for medical record structuring,structured assessment,data annotation,routine functions and system management.Results The system developed transformed the text of electronic medical records into structured language,contributed to data element extraction and intelligent structured service and enhanced the efficiency of clinical treatment and scientific research.Conclusion The system developed improves the data availability of clinical diseases,reduces the workload of user data processing,ensures the quality of data application and lays a foundation for assisted decision making during clinical treatment and scientific research.[Chinese Medical Equipment Journal,2024,45(4):20-26]
7.Theta Oscillations Support Prefrontal-hippocampal Interactions in Sequential Working Memory.
Minghong SU ; Kejia HU ; Wei LIU ; Yunhao WU ; Tao WANG ; Chunyan CAO ; Bomin SUN ; Shikun ZHAN ; Zheng YE
Neuroscience Bulletin 2024;40(2):147-156
The prefrontal cortex and hippocampus may support sequential working memory beyond episodic memory and spatial navigation. This stereoelectroencephalography (SEEG) study investigated how the dorsolateral prefrontal cortex (DLPFC) interacts with the hippocampus in the online processing of sequential information. Twenty patients with epilepsy (eight women, age 27.6 ± 8.2 years) completed a line ordering task with SEEG recordings over the DLPFC and the hippocampus. Participants showed longer thinking times and more recall errors when asked to arrange random lines clockwise (random trials) than to maintain ordered lines (ordered trials) before recalling the orientation of a particular line. First, the ordering-related increase in thinking time and recall error was associated with a transient theta power increase in the hippocampus and a sustained theta power increase in the DLPFC (3-10 Hz). In particular, the hippocampal theta power increase correlated with the memory precision of line orientation. Second, theta phase coherences between the DLPFC and hippocampus were enhanced for ordering, especially for more precisely memorized lines. Third, the theta band DLPFC → hippocampus influence was selectively enhanced for ordering, especially for more precisely memorized lines. This study suggests that theta oscillations may support DLPFC-hippocampal interactions in the online processing of sequential information.
Adult
;
Female
;
Humans
;
Young Adult
;
Epilepsy
;
Hippocampus
;
Memory, Short-Term
;
Mental Recall
;
Prefrontal Cortex
;
Theta Rhythm
;
Male
8.Application of mixed reality technology in vertebroplasty
Yong JIANG ; Tianmin GUAN ; Yuan CI ; Ye ZHU ; Peng ZHAO ; Jiafa ZHENG ; Tao YANG ; Guangyu ZHANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4812-4816
BACKGROUND:How to improve the accuracy of puncture,reduce surgical damage,and improve surgical efficiency during vertebroplasty is currently one of the focuses of exploration and improvement in vertebroplasty techniques. OBJECTIVE:To explore the clinical significance of application of mixed reality technology in percutaneous vertebroplasty for spinal fractures. METHODS:Two patients with osteoporotic vertebral compression fracture in Dalian Second People's Hospital in June 2023 were selected.Before operation,128-row CT scanning of the lumbar spine was performed and the original data of digital imaging and communications in medicine(DICOM)were obtained.Visual Volume software was used to build the three-dimensional network model of vertebral compression fracture.Holographic imaging glasses were used to accurately map 3D network model images to the real world,assist the surgeon in completing preoperative simulation,explaining preoperative conditions and treatment plans,and guiding puncture and bone cement injection during surgery. RESULTS AND CONCLUSION:(1)Precise puncture was achieved with the assistance of a mixed reality technology.Postoperative imaging examination showed good bone cement filling and no obvious leakage.The postoperative symptoms of the patient were alleviated well,and they were able to move to the ground on the same day after surgery.(2)It is concluded that a mixed reality technology is helpful for preoperative surgical design and communication efficiency with patients and their families.Assisting with precise puncture during surgery,shortening surgical time,and reducing side injuries is a new and effective clinical diagnosis and treatment model,which has development potential in minimally invasive,precise,and personalized treatment of spinal surgery.
9.Treatment of polyethylene sleeve wear in rotating hinge knee joint with femoral component revision surgery
Ye TAO ; Jun FU ; Hanwen HU ; Qingyuan ZHENG ; Jiying CHEN ; Ming NI
Chinese Journal of Orthopaedics 2024;44(4):210-216
Objective:To investigate the clinical efficacy of femoral component revision surgery in addressing polyethylene sleeve wear in rotating hinge knee joints.Methods:A retrospective analysis was conducted on 21 patients who underwent treatment for polyethylene sleeve wear in rotating hinge knee joints at the Department of Orthopaedics, the Fourth Medical Center, PLA General Hospital, spanning from August 2008 to April 2023. There were 8 males and 13 females with a median age of 63(38, 76) years. Among them, 11 cases involved the left side, and 10 cases involved the right side. The average body mass index (BMI) was 25.0(22.5, 31.0) kg/m 2, and all cases underwent unilateral knee joint revision. The time interval from receiving the hinge knee joint prosthesis to revision was 10.5(6.0, 17.0) years, with 18 cases undergoing primary revision and 3 cases undergoing revision for the second time. Revision surgery of the femoral component sleeve was performed in all patients due to polyethylene sleeve wear. Visual analogue scale (VAS), range of motion (ROM) of the knee joint, changes in hip-knee-ankle angle (HKA), and Knee Society score (KSS) were collected and recorded to assess the surgical outcomes. Results:All patients were followed up for a median duration of 12.5(11.7, 13.4) months. Preoperatively, the VAS score was 5(3, 7) points, which significantly decreased to 0(0, 1) points at the last follow-up ( Z=5.721, P<0.001). At the last follow-up, the KSS scores decreased from 41.19±13.65 points preoperatively to 79.81±7.80 points, indicating a statistically significant difference ( t=12.560, P<0.001). HKA increased from 174.65°±5.20° preoperatively to 178.71°±2.79°, with a statistically significant difference ( t=5.533, P<0.001). Knee joint ROM increased from 69.05°±34.37° preoperatively to 110.00°±10.12°, also demonstrating a significant improvement ( t=5.960, P<0.001). Notably, patients exhibited knee joint stability with no passive flexion or extension laxity. Conclusion:Femoral component sleeve revision surgery effectively addresses polyethylene sleeve wear in rotating hinge knee joint prostheses, thereby mitigating the substantial loss of bone and soft tissue associated with overall revision procedures. The early postoperative clinical outcomes are promising and indicative of the efficacy of this surgical intervention.
10.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.

Result Analysis
Print
Save
E-mail