1.Diagnostic Accuracy of Serological Tests for Mycoplasma pneumoniae Infections in Children with Pneumonia, Based on Symptom Onset
Gahee KIM ; Ki Wook YUN ; Dayun KANG ; Taek Jin LEE ; Byung Wook EUN ; Hyunju LEE ; Yae-Jean KIM ; Doo Ri KIM ; Areum SHIN ; Hyun Mi KANG ; Ye Ji KIM ; Byung Ok KWAK ; Younghee LEE ; Ye Kyung KIM ; Young June CHOE ; Woosuck SUH ; Kyo Jin JO ; Kyung-Ran KIM ; Eun Young CHO ; Kyung Min KIM ; Joon Kee LEE ; Su Eun PARK
Annals of Laboratory Medicine 2026;46(2):162-170
Background:
Mycoplasma pneumoniae is a major cause of community-acquired pneumonia (CAP) in children, with a rising incidence of macrolide resistance. Early diagnosis is crucial for reducing the disease burden; however, current diagnostic tools have limitations.We evaluated the diagnostic accuracy of serological assays and their performance based on symptom onset in children with CAP.
Methods:
From September 2023 to September 2024, we prospectively enrolled children with CAP, classified as M. pneumoniae pneumonia (MPP) or non-MPP, from 16 hospitals in Korea. Serological testing included chemiluminescence immunoassay (CLIA) and ELISA for detecting IgM and IgG, along with particle agglutination (PA) for total antibody measurements. Serological responses were analyzed at different times after symptom onset (0–4, 5–9, and 10–21 days).
Results:
Among 472 children with CAP (362 MPP, 110 non-MPP), 138 (29.2%) underwent PA testing, and 334 (70.8%) underwent IgM testing. PA at a 1:640 cutoff showed 48.0% sensitivity and 100% specificity. CLIA and ELISA showed comparable sensitivities (69.1% vs. 69.2%) and specificities (76.9% vs. 66.7%) for IgM testing. Seropositivity increased significantly with time since symptom onset (P for trend < 0.001), reaching 97.9% for IgM, 62.5% for IgG, and 94.7% for PA at 10–21 days.
Conclusions
The time post-symptom onset significantly influenced the diagnostic utility of serological tests for pediatric MPP, which showed limited value during the early stage of illness. These findings emphasize the importance of symptom onset-based interpretation of serological test results and their utility in complementing PCR when optimizing MPP diagnosis in children.
2.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
6.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
7.Psychological Treatments for Adult Patients with Anorexia Nervosa in Korea: A Retrospective Study
Youl-Ri KIM ; Zhen AN ; Ye Sol KIM ; Seung Min OH ; Eun Mi LEE ; Janet TREASURE
Clinical Psychopharmacology and Neuroscience 2025;23(4):614-627
Objective:
International treatment guidelines recommend psychotherapy as the first-line treatment for anorexia nervosa (AN). Adaptation of Western evidence-based treatments to different cultures through personalization has become increasingly important, but evidence remains limited. This study examined the feasibility and effectiveness of AN outpatient psychotherapies in Korea.
Methods:
A total of 160 adult patients diagnosed with AN (mean age = 25.3 years) were recruited from an eating disorder (ED) clinic in Korea. They received one of the following psychotherapy programs: motivational enhancement therapy with nutrition (MET with nutrition) (n = 47); Maudsley Model of Anorexia Nervosa Treatment for Adults (MANTRA) augmented by New Maudsley Model for Collaborative Care (NMCC) (n = 20); or Specialist Supportive Clinical Management (SSCM) (n = 93). Treatments were administered face-to-face by trained therapists, following protocols tailored to each individual. Demographic and ED‐related clinical data were collected through standardized interviews and questionnaires at baseline and at the end of treatment.
Results:
Overall dropout rate was 40.3%, with a lower rate observed in MANTRA augmented by NMCC and SSCM than MET with nutrition. All three psychotherapies increased body mass index (BMI), with minimal group differences.Individuals with lower baseline BMI and those who attended more sessions experienced greater BMI increases across all psychotherapies.
Conclusion
Psychotherapies for AN were feasible and showed promise in terms of effectiveness among Korean patients.Despite comparable BMI increases, the therapies led by experienced therapists and with greater personalization had lower dropout rates. Further studies using randomized controlled trials are needed while controlling for variables outside treatments.
8.A Nationwide Study on HER2-Low Breast Cancer in South Korea: Its Incidence of 2022 Real World Data and the Importance of Immunohistochemical Staining Protocols
Min Chong KIM ; Eun Yoon CHO ; So Yeon PARK ; Hee Jin LEE ; Ji Shin LEE ; Jee Yeon KIM ; Ho-chang LEE ; Jin Ye YOO ; Hee Sung KIM ; Bomi KIM ; Wan Seop KIM ; Nari SHIN ; Young Hee MAENG ; Hun Soo KIM ; Sun Young KWON ; Chungyeul KIM ; Sun-Young JUN ; Gui Young KWON ; Hye Jeong CHOI ; So Mang LEE ; Ji Eun CHOI ; Ae Ri AN ; Hyun Joo CHOI ; EunKyung KIM ; Ahrong KIM ; Ji-Young KIM ; Jeong Yun SHIM ; Gyungyub GONG ; Young Kyung BAE
Cancer Research and Treatment 2024;56(4):1096-1104
Purpose:
Notable effectiveness of trastuzumab deruxtecan in patients with human epidermal growth factor receptor 2 (HER2)–low advanced breast cancer (BC) has focused pathologists’ attention. We studied the incidence and clinicopathologic characteristics of HER2-low BC, and the effects of immunohistochemistry (IHC) associated factors on HER2 IHC results.
Materials and Methods:
The Breast Pathology Study Group of the Korean Society of Pathologists conducted a nationwide study using real-world data on HER2 status generated between January 2022 and December 2022. Information on HER2 IHC protocols at each participating institution was also collected.
Results:
Total 11,416 patients from 25 institutions included in this study. Of these patients, 40.7% (range, 6.0% to 76.3%) were classified as HER2-zero, 41.7% (range, 10.5% to 69.1%) as HER2-low, and 17.5% (range, 6.7% to 34.0%) as HER2-positive. HER2-low tumors were associated with positive estrogen receptor and progesterone receptor statuses (p < 0.001 and p < 0.001, respectively). Antigen retrieval times (≥ 36 minutes vs. < 36 minutes) and antibody incubation times (≥ 12 minutes vs. < 12 minutes) affected on the frequency of HER2 IHC 1+ BC at institutions using the PATHWAY HER2 (4B5) IHC assay and BenchMark XT or Ultra staining instruments. Furthermore, discordant results between core needle biopsy and subsequent resection specimen HER2 statuses were observed in 24.1% (787/3,259) of the patients.
Conclusion
The overall incidence of HER2-low BC in South Korea concurs with those reported in previously published studies. Significant inter-institutional differences in HER2 IHC protocols were observed, and it may have impact on HER2-low status. Thus, we recommend standardizing HER2 IHC conditions to ensure precise patient selection for targeted therapy.
9.Influence of Band and Loop Type Space Maintainer on Intraoral Scanning Accuracy of an Adjacent Tooth
Ju Ri YE ; Yong Kwon CHAE ; Ko Eun LEE ; Hyo-Seol LEE ; Sung Chul CHOI ; Ok Hyung NAM
Journal of Korean Dental Science 2023;16(2):149-155
Purpose:
The purpose of this study was to evaluate whether the presence of a space maintainer affects the accuracy of an intraoral scanner.
Materials and Methods:
The maxillary primary first molar typodont tooth was removed from the primary dentition typodont model and a band and loop type space maintainer was delivered. After the model was connected to a dental phantom, intraoral scan was performed using TRIOS 4 (3Shape A/S, Copenhagen, Denmark). The scan was repeated with the same technique without the space maintainer. Each scan was performed 10 times. All scan files into a GOM inspect 2018 software and evaluated the accuracy. The accuracy was evaluated on trueness and precision, and calculated using the root mean square value.Result: When there was a space maintainer in the oral cavity, the trueness value was 0.10±0.02 mm and the precision value was 0.15±0.03 mm. In the absence of the space maintainer, the trueness value was 0.12±0.03 mm and the precision value was 0.16±0.04 mm. There were no significant differences depending on the presence of a space maintainer (P>0.05).
Conclusion
Within the limits of this study, the accuracy of the intraoral scanner was not influenced by the presence of space maintainer.
10.Shinjulactone A Blocks Vascular Inflammation and the EndothelialMesenchymal Transition
Ye-eun JANG ; Jenita IMMANUEL ; Jin-ri LEE ; Yu-jin JANG ; Yun Ju KWON ; Hyun Sook KWON ; Jung-Woog SHIN ; Sanguk YUN
Journal of Lipid and Atherosclerosis 2022;11(3):272-279
Objective:
The endothelial inflammatory response plays an important role in atherogenesis by inducing nuclear factor (NF)κB-dependent cell adhesion molecule expression and monocyte recruitment. Here, we screened for natural ligands and investigated the ability of shinjulactone A to inhibit interleukin-1β (IL-1β)-induced endothelial inflammatory signaling.
Methods:
The natural compound library included 880 single compounds isolated from medicinal plants by the Korean Medicinal Material Bank. Primary endothelial cells were pretreated with single compounds before stimulation with IL-1β to induce endothelial inflammation. Endothelial inflammation was measured by assaying NFκB activation and monocyte adhesion. The endothelial-mesenchymal transition (EndMT) was evaluated using cell type-specific marker protein expression and morphology.
Results:
Shinjulactone A was identified as an efficient blocker of IL-1β -induced NFκB activation, with a half-maximal inhibitory concentration of approximately 1 µM, and monocyte recruitment in endothelial cells. However, it did not affect lipopolysaccharideinduced NFκB activation in macrophages. Compared to Bay 11-782, a well-known NFκB inhibitor that shows considerable cytotoxicity during long-term treatment, shinjulactone A did not affect endothelial cell viability. Furthermore, it also significantly inhibited the EndMT, which is known to promote atherosclerosis and plaque instability.
Conclusion
We suggest that shinjulactone A may be an effective and safe drug candidate for atherosclerosis because it targets and inhibits both endothelial inflammation and the EndMT, without impairing NFκB-dependent innate immunity in macrophages.

Result Analysis
Print
Save
E-mail