1.SOX11-mediated CBLN2 Upregulation Contributes to Neuropathic Pain through NF-κB-Driven Neuroinflammation in Dorsal Root Ganglia of Mice.
Ling-Jie MA ; Tian WANG ; Ting XIE ; Lin-Peng ZHU ; Zuo-Hao YAO ; Meng-Na LI ; Bao-Tong YUAN ; Xiao-Bo WU ; Yong-Jing GAO ; Yi-Bin QIN
Neuroscience Bulletin 2025;41(12):2201-2217
Neuropathic pain, a debilitating condition caused by dysfunction of the somatosensory nervous system, remains difficult to treat due to limited understanding of its molecular mechanisms. Bioinformatics analysis identified cerebellin 2 (CBLN2) as highly enriched in human and murine proprioceptive and nociceptive neurons. We found that CBLN2 expression is persistently upregulated in dorsal root ganglia (DRG) following spinal nerve ligation (SNL) in mice. In addition, transcription factor SOX11 binds to 12 cis-regulatory elements within the Cbln2 promoter to enhance its transcription. SNL also induced SOX11 upregulation, with SOX11 and CBLN2 co-localized in nociceptive neurons. The siRNA-mediated knockdown of Sox11 or Cbln2 attenuated SNL-induced mechanical allodynia and thermal hyperalgesia. High-throughput sequencing of DRG following intrathecal injection of CBLN2 revealed widespread gene expression changes, including upregulation of numerous NF-κB downstream targets. Consistently, CBLN2 activated NF-κB signaling, and inhibition with pyrrolidine dithiocarbamate reduced CBLN2-induced pain hypersensitivity, proinflammatory cytokines and chemokines production, and neuronal hyperexcitability. Together, these findings identified the SOX11/CBLN2/NF-κB axis as a critical mediator of neuropathic pain and a promising target for therapeutic intervention.
Animals
;
Neuralgia/metabolism*
;
Ganglia, Spinal/metabolism*
;
Up-Regulation
;
Mice
;
NF-kappa B/metabolism*
;
SOXC Transcription Factors/genetics*
;
Male
;
Neuroinflammatory Diseases/metabolism*
;
Mice, Inbred C57BL
;
Nerve Tissue Proteins/genetics*
;
Hyperalgesia/metabolism*
;
Signal Transduction
;
Spinal Nerves
2.Research progress on central memory T cells.
Junwei HUANG ; Wei LU ; Jingxin YAO ; Hanwei DENG ; Ji BIN ; Yuexiang MA ; Zhenhua ZHU
Chinese Journal of Cellular and Molecular Immunology 2025;41(5):468-474
Central memory T (Tcm) cells are a crucial subset in T cell development, playing an important role in long-term immune responses. Tcm cells exhibit strong proliferative capacity, long-term survival characteristics, and re-activation potential, enabling them to rapidly differentiate into effector T cells (Teff) upon antigen re-exposure, thus providing robust immune protection. The function of Tcm cells is regulated by various factors, including antigen exposure, cytokines, and metabolic conditions. A deeper understanding of their metabolic and epigenetic mechanisms under different pathological conditions will contribute to the development of more precise and effective immunotherapeutic strategies. This review elaborates on the origin and characteristics of Tcm cells, as well as their roles in antiviral responses, tumor immunity, and immunotherapy.
Humans
;
Memory T Cells/cytology*
;
Animals
;
Immunologic Memory
;
Neoplasms/therapy*
;
Immunotherapy
3.Study on protective effect of medical X-ray diagnosis equipment based on risk analysis of correlation
Lin SONG ; Jun HAN ; Weijie ZHU ; Bin BAI ; Debiao YAO ; Yongzhong MA
China Medical Equipment 2025;22(5):99-104
Objective:To formulate refined management strategies to improve the operation quality and protective effect of medical X-ray diagnosis equipment based on the risk analysis of the correlation of medical X-ray diagnostic equipment.Methods:The used 41 medical X-ray diagnosis equipment in Fuwai Hospital,Chinese Academy of Medical Sciences from January 2022 to December 2023 were selected.According to different management modes for equipment,they were managed respectively by the conventional management mode(20 units)and the management mode with risk analysis of the correlation(21 units).The risk grades of correlation of management mode with risk analysis of the correlation were classified on the basis of the probability of risk and the degree of harm in medical X-ray diagnosis equipment.The protection management of equipment was conducted from three aspects included the location of equipment,the staffs and subjects.A self-made questionnaire was used to investigate the satisfactions of engineers of using management for equipment,operators,and staffs of operating and maintaining equipment for the two kinds of management modes.The protection quality,failure rate of equipment,and qualification rate of protection of medical X-ray diagnosis equipment under different management modes were compared.Results:The quality scores of operation safety,regular inspection,maintenance and repair,and shielding protection for radiation of medical X-ray diagnosis equipment that adopted the management mode with risk analysis of the correlation were respectively(92.14±3.36),(91.47±2.41),(92.54±3.32)and(91.69±3.57)points,all of which were higher than those of the conventional management mode,and the differences of them were statistically significant(t=16.396,17.368,19.688,14.401,P<0.05).The failure rate of the 21 medical X-ray diagnosis equipment that adopted the management mode with risk analysis of correlation was 0,which was lower than 20.00%of the conventional management mode.The qualified rate of protection was 95.23%,which was higher than 70.00%of the conventional management mode,and the differences of them were statistically significant(x2=4.654,4.608,P<0.05).The satisfaction scores of engineers of using equipment,operators and staffs of operating and maintaining equipment for the protective effect of adopting the management mode with risk analysis of correlation were respectively(94.69±4.02),(93.21±4.36)and(92.54±3.47)points,all of which were higher than those of the conventional management mode,and the differences were statistically significant(t=16.902,11.291,12.020,P<0.05).Conclusion:The process-based protection management strategy on the basis of risk analysis of correlation for medical X-ray diagnosis equipment can prevent risks of medical X-ray diagnostic equipment,and improve the operation quality of the equipment,and reduce the operation risks of the equipment,and maximize the enhancement for management quality of medical X-ray diagnosis equipment.
4.Simultaneous Determination of 21 Kinds of Aconitum Alkaloids in Biological Specimens and Herbal Wines Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
Ju YANG ; Guo-Jun LI ; Xian-Mou FAN ; Rui-Bin ZHAO ; Shao-Ming SU ; Xu-Xian FU ; En-Jin ZHU ; Qi-Lin HUANG ; Yao QIN ; Li-Na LI
Chinese Journal of Analytical Chemistry 2025;53(8):1391-1401,后插1-后插6,封3
A method for simultaneous determination of 21 kinds of Aconitum alkaloids(ATS)in biological specimens and infused liquor using ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)was developed.The biological samples were pretreated with methanol-acetonitrile(1∶2,V/V)for protein precipitation,while infused liquors were diluted 100-fold with acetonitrile,followed by centrifugation,and filtration by a 0.22-μm membrane.Chromatographic separation was carried out on an EC-C18 column using gradient elution with the mixture of 10 mmol/L ammonium acetate and 0.2%formic acid as mobile phase A and acetonitrile as mobile phase B.With this method,all the analytes were separated within 9.5 min.The samples were detected in positive ESI mode with dynamic multiple reaction monitoring(MRM)and quantified via external standard calibration.The results showed that the concentrations of the analytes in the range of 2-1000 ng/mL had excellent linearity(R2>0.9992)with the peak area.The developed method was successfully used for detection of 21 kinds of aconitum alkaloids,with limits of detection of 0.5-2 ng/mL,quantification limits of 2-6 ng/mL,intra/inter-day precision≤6.0%,spiked recoveries of 89.4%-100.9%,extraction recoveries of 74.2%-104.4%,and matrix effects ranging from-11.1%to 9.2%in blood/urine.The method was applied to detection of 12 samples from 4 fatal aconite poisoning cases,and all 21 kinds of ATS with total alkaloid concentrations of 0.04-4.18 μg/mL in blood and 154.96-422.83 μg/mL in medicinal liquors were detected.Tissue distribution revealed that the order of concentrations from highest to lowest is as follows:urine(157.22 μg/mL)>gastric contents(51.37 μg/mL)>kidney(21.6 μg/g)>whole blood(4.18 μg/mL)>liver(0.03 μg/g).This method showed many advantages such as simple pretreatment,low detection limits,accurate quantification,broad analyte coverage,and superior anti-interference capability in complex matrices,proving ideal for forensic and toxicological analysis of aconitum alkaloids.
5.Study on protective effect of medical X-ray diagnosis equipment based on risk analysis of correlation
Lin SONG ; Jun HAN ; Weijie ZHU ; Bin BAI ; Debiao YAO ; Yongzhong MA
China Medical Equipment 2025;22(5):99-104
Objective:To formulate refined management strategies to improve the operation quality and protective effect of medical X-ray diagnosis equipment based on the risk analysis of the correlation of medical X-ray diagnostic equipment.Methods:The used 41 medical X-ray diagnosis equipment in Fuwai Hospital,Chinese Academy of Medical Sciences from January 2022 to December 2023 were selected.According to different management modes for equipment,they were managed respectively by the conventional management mode(20 units)and the management mode with risk analysis of the correlation(21 units).The risk grades of correlation of management mode with risk analysis of the correlation were classified on the basis of the probability of risk and the degree of harm in medical X-ray diagnosis equipment.The protection management of equipment was conducted from three aspects included the location of equipment,the staffs and subjects.A self-made questionnaire was used to investigate the satisfactions of engineers of using management for equipment,operators,and staffs of operating and maintaining equipment for the two kinds of management modes.The protection quality,failure rate of equipment,and qualification rate of protection of medical X-ray diagnosis equipment under different management modes were compared.Results:The quality scores of operation safety,regular inspection,maintenance and repair,and shielding protection for radiation of medical X-ray diagnosis equipment that adopted the management mode with risk analysis of the correlation were respectively(92.14±3.36),(91.47±2.41),(92.54±3.32)and(91.69±3.57)points,all of which were higher than those of the conventional management mode,and the differences of them were statistically significant(t=16.396,17.368,19.688,14.401,P<0.05).The failure rate of the 21 medical X-ray diagnosis equipment that adopted the management mode with risk analysis of correlation was 0,which was lower than 20.00%of the conventional management mode.The qualified rate of protection was 95.23%,which was higher than 70.00%of the conventional management mode,and the differences of them were statistically significant(x2=4.654,4.608,P<0.05).The satisfaction scores of engineers of using equipment,operators and staffs of operating and maintaining equipment for the protective effect of adopting the management mode with risk analysis of correlation were respectively(94.69±4.02),(93.21±4.36)and(92.54±3.47)points,all of which were higher than those of the conventional management mode,and the differences were statistically significant(t=16.902,11.291,12.020,P<0.05).Conclusion:The process-based protection management strategy on the basis of risk analysis of correlation for medical X-ray diagnosis equipment can prevent risks of medical X-ray diagnostic equipment,and improve the operation quality of the equipment,and reduce the operation risks of the equipment,and maximize the enhancement for management quality of medical X-ray diagnosis equipment.
6.Impact of inhaled corticosteroid use on elderly chronic pulmonary disease patients with community acquired pneumonia.
Xiudi HAN ; Hong WANG ; Liang CHEN ; Yimin WANG ; Hui LI ; Fei ZHOU ; Xiqian XING ; Chunxiao ZHANG ; Lijun SUO ; Jinxiang WANG ; Guohua YU ; Guangqiang WANG ; Xuexin YAO ; Hongxia YU ; Lei WANG ; Meng LIU ; Chunxue XUE ; Bo LIU ; Xiaoli ZHU ; Yanli LI ; Ying XIAO ; Xiaojing CUI ; Lijuan LI ; Xuedong LIU ; Bin CAO
Chinese Medical Journal 2024;137(2):241-243
7.Application of China-made Toumai? Robot in laparoscopic radical prostatectomy
Zhi-Feng WEI ; Yu-Hao CHEN ; Ze-Peng ZHU ; Qi JIANG ; Yu XIONG ; Feng-Feng LU ; Zhen-Qian SONG ; Bin JIANG ; Xiao-Feng ZHU ; Tian-Hao FENG ; Xiao-Feng XU ; Gang YANG ; Wu WEI ; Ai-Bing YAO ; Jing-Ping GE
National Journal of Andrology 2024;30(8):696-700
Objective:To evaluate the safety and efficiency of China-made Toumai Robot-assisted laparoscopic radical prosta-tectomy(LRP).Methods:This study included 40 cases of PCa treated from January 2023 to May 2023 by robot-assisted LRP with preservation of the bladder neck and maximal functional urethral length,15 cases with the assistance of Toumai Robot(the TMR group)and the other 25 with the assistance of da Vinci Robot as controls(the DVR group).We recorded the docking time,laparo-scopic surgery time,vesico-urethral anastomosis time,intraoperative blood loss and postoperative urinary continence,and compared them between the two groups.Results:Operations were successfully completed in all the cases.No statistically significant differ-ences were observed between the TMR and DVR groups in the docking time(6 min vs 5 min,P>0.05)or intraoperative blood loss(200 ml vs 150 ml,P>0.05).The TMR group,compared with the DVR group,showed a significantly longer median laparoscopic surgery time(146 min vs 130 min,P<0.05)and median vesico-urethral anastomosis time(19 min vs 16 min,P<0.05).There were no statistically significant differences between the TMR and DVR groups in the rates of urinary continence recovery immediately af-ter surgery(60.0%[9/15]vs 64.0%[16/25],P>0.05)or at 1 month(80.0%[12/15])vs(76.0%[19/25],P>0.05),3 months(93.3%[14/15])vs(92.0%[23/25],P>0.05)and 6 months postoperatively(100%[15/15])vs(96%[24/25],P>0.05).Conclusion:China-made Toumai? Robot surgical system is safe and reliable for laparoscopic radical prosta-tectomy,with satisfactory postoperative recovery of urinary continence.
8.Modified scrotoscopic surgery for testicular hydrocele
Tian-Hao FENG ; Ai-Bing YAO ; Qi JIANG ; Xiao-Feng ZHU ; Yu XIONG ; Zhen-Qian SONG ; Feng-Feng LU ; Bin JIANG ; Zhi-Feng WEI
National Journal of Andrology 2024;30(10):910-914
Objective:To explore the application of modified scrotoscopic surgery(MSS)in the treatment of testicular hydro-cele.Methods:We selected 45 cases of testicular hydrocele for this study,22 treated by traditional scrotoscopic surgery(TSS)and the other 23 by MSS,which was performed with a pin-shaped electrode bent inward at an angle of 60° instead of a circular electrode used in TSS.We recorded the general clinical data,operation time,incision length,intraoperative injury,incision infection,scrotal e-dema,postoperative hospital stay and postoperative Visual Analogue Scale(VAS)scores of the patients and compared them between the two groups.Results:There was no statistically significant difference in the general clinical data between the two groups(P>0.05).Compared with the patients of the TSS group,those of the MSS group showed significantly shorter operative time([32.86±3.80]vs[26.13±2.81]min,P<0.05),incision length([14.09±2.23]vs[8.73±1.48]mm,P<0.05)and postopera-tive hospital stay([4.36±1.05]vs[2.00±0.90]d,P<0.05),and achieved remarkably lower VAS scores on postoperative days 1(4.41±1.05 vs 3.09±0.79,P<0.05),2(3.36±1.05 vs 2.78±1.13,P<0.05),3(2.65±0.72 vs 1.74±0.86,P<0.05)and 7(1.91±0.81 vs 1.04±0.82,P<0.05).At 3 and 7 days after surgery,scrotal edema was markedly mil-der in the MSS than in the TSS group(P<0.05).No testicular or epididymal damage,or wound infection occurred in either of the two groups.Conclusion:MSS is safe and effective in the treatment of testicular hydrocele,superior to TSS for its advantages of shorter operation time,smaller surgical incision,less postoperative pain and milder scrotal edema.
9.Dual-targeted halofuginone hydrobromide nanocomplexes for promotion of macrophage repolarization and apoptosis of rheumatoid arthritis fibroblast-like synoviocytes in adjuvant-induced arthritis in rats.
Junping ZHU ; Ye LIN ; Gejing LI ; Yini HE ; Zhaoli SU ; Yuanyuan TANG ; Ye ZHANG ; Qian XU ; Zhongliu YAO ; Hua ZHOU ; Bin LIU ; Xiong CAI
Journal of Pharmaceutical Analysis 2024;14(11):100981-100981
Rheumatoid arthritis (RA) is a prevalent autoimmune disease characterized by chronic inflammation and excessive proliferation of the synovium. Currently, treatment options focus on either reducing inflammation or inhibiting synovial hyperplasia. However, these modalities are unsatisfactory in achieving the desired therapeutic outcomes. Halofuginone hydrobromide (HF), an herbal active ingredient, has demonstrated pharmacological effects of both anti-inflammation and inhibition of synovial hyperplasia proliferation. However, HF's medical efficacy is limited due to its poor water solubility, short half-life (t 1/2), and non-target toxicity. In the current study, by using the advantages of nanotechnology, we presented a novel dual-targeted nanocomplex, termed HA-M@P@HF NPs, which consisted of a hyaluronic acid (HA)-modified hybrid membrane (M)-camouflaged poly lactic-co-glycolic acid (PLGA) nanosystem for HF delivery. These nanocomplexes not only overcame the limitations of HF but also achieved simultaneous targeting of inflammatory macrophages and human fibroblast-like synoviocytes-RA (HFLS-RA). In vivo experiments demonstrated that these nanocomplexes effectively suppressed immune-mediated inflammation and synovial hyperplasia, safeguarding against bone destruction in rats with adjuvant-induced arthritis (AIA). Remarkable anti-arthritic effects of these nanocomplexes were accomplished through promoting repolarization of M1-to-M2 macrophages and apoptosis of HFLS-RA, thereby offering a promising therapeutic strategy for RA.
10.Ultra-fast track anesthesia management for transcatheter mitral valve edge-to-edge repair
Zhi-Yao ZOU ; Da ZHU ; Yi-Ming CHEN ; Shou-Zheng WANG ; Jian-Bin GAO ; Jing DONG ; Xiang-Bin PAN ; Ke YANG
Chinese Journal of Interventional Cardiology 2024;32(5):250-256
Objective To retrospectively analyze the ultra-fast track anesthesia(UFTA)methods and perioperative anesthesia management experiences of transcatheter mitral valve edge-to-edge repair(TEER)in the treatment of functional mitral regurgitant.Methods In this retrospective study,patients underwent the TEER procedure and received UFTA in Fuwai Yunnan Hospital,from May 2022 to September 2022 for heart failure combined with moderate to severe or severe functional mitral regurgitant were included.Baseline,preoperative complications,cardial function and anesthesia classification,amino-terminal probrain natriuretic peptide(NT-proBNP),ultrasound examination results,surgery time,extubation time,intraoperative anesthetic and vasoactive drug,complications related to TEER and UFTA,perioperative,and postoperative 30-day and one-year follow-up data were collected.All perioperative clinical data were recorded and analyzed.Results A total of 30 patients were enrolled,11 patients(36.7%)were female,mean age was(63.6±6.1)years,NYHA classification IV 14 patients(46.7%),left ventricular ejection fraction(LVEF)(36.0±8.1)%,the end-diastolic volume of the left ventricle(66.0±8.2)mm,mitral regurgitation 4+14 patients(56.7%),3+17 patients(43.3%),NT-proBNP(1 934.1±1 973.5)pg/ml,1 patient(3.3%)used high-dose vasoactive drugs during surgery.All patients did not experience nausea,vomiting,delirium,respiratory depression,perioperative transesophageal echocardiography-related gastrointestinal bleeding,pericardial effusion,cerebrovascular accidents,emergency surgery or secondary intervention,or other serious adverse events within 24 hours after surgery.No 30-day all-cause death occurred;the mean postoperative hospital stay was(7.4±2.8)days.All patients completed one-year follow-up,LVEF(37.6±11.1)%,the end-diastolic volume of the left ventricle(63.2±8.6)mm,mitral regurgitation 2+7 patients(23.3%),1+23 patients(76.7%),NT-proBNP(1 949.2±2 576.6)pg/ml.Conclusions Ultra-fast track anesthesia can be safely applied to TEER in treating functional mitral regurgitant patients.

Result Analysis
Print
Save
E-mail