1.Preparation of the Fusion Protein Between Diphtheria Toxin Mutants and the Receptor Binding Domain of Botulinum Neurotoxin Serotype E(EHc)Molecules and the Immunological Effect Evaluation
Qiu-Ju JIA ; Yao-Hui ZHAO ; Xiao-Yu LIU ; Shuo YU ; Jian-Sheng LU ; Yun-Zhou YU ; Ming LIAO
Chinese Journal of Biochemistry and Molecular Biology 2025;41(10):1421-1431
CRM 197(cross-reacting material 197),a naturally occurring mutant of diphtheria toxin,is a safe and effective vaccine vector and extensively used on developing conjugate or combined vaccines.The mutant loses its enzymatic activity,but fully retains its receptor-binding ability and immunogenicity.In current work,the diphtheria toxin mutant CRM 197 and its fusion proteins with the receptor-binding do-main of botulinum neurotoxin serotype E(EHc)were developed using genetic engineering technology.These recombinant proteins were confirmed by Western blotting and SDS-PAGE.BALB/c mice were im-munized with the CRM197-EHc and EHc-CRM197 fusion proteins,and their immunogenicity was evalua-ted.These two fusion protein molecules,CRM197-EHc and EHc-CRM197,as subunit vaccines,elicited a robust humoral immune response targeting both CRM197 and EHc antigens in the immunized mice.Compared to the mixture of CRM197 and EHc,the mice vaccinated with the fusion proteins(CRM197-EHc and EHc-CRM197)induced higher levels of anti-CRM197 antibodies,and the mice vaccinated with EHc-CRM197 also generated strongest anti-EHc antibodies.Consequently,as a carrier molecule in the fusion protein vaccine,EHc enhances the immunogenicity of CRM197 molecules.Likewise,CRM197 boosts the immunogenicity of EHc in the EHc-CRM197 fusion protein.
2.Preparation of the Fusion Protein Between Diphtheria Toxin Mutants and the Receptor Binding Domain of Botulinum Neurotoxin Serotype E(EHc)Molecules and the Immunological Effect Evaluation
Qiu-Ju JIA ; Yao-Hui ZHAO ; Xiao-Yu LIU ; Shuo YU ; Jian-Sheng LU ; Yun-Zhou YU ; Ming LIAO
Chinese Journal of Biochemistry and Molecular Biology 2025;41(10):1421-1431
CRM 197(cross-reacting material 197),a naturally occurring mutant of diphtheria toxin,is a safe and effective vaccine vector and extensively used on developing conjugate or combined vaccines.The mutant loses its enzymatic activity,but fully retains its receptor-binding ability and immunogenicity.In current work,the diphtheria toxin mutant CRM 197 and its fusion proteins with the receptor-binding do-main of botulinum neurotoxin serotype E(EHc)were developed using genetic engineering technology.These recombinant proteins were confirmed by Western blotting and SDS-PAGE.BALB/c mice were im-munized with the CRM197-EHc and EHc-CRM197 fusion proteins,and their immunogenicity was evalua-ted.These two fusion protein molecules,CRM197-EHc and EHc-CRM197,as subunit vaccines,elicited a robust humoral immune response targeting both CRM197 and EHc antigens in the immunized mice.Compared to the mixture of CRM197 and EHc,the mice vaccinated with the fusion proteins(CRM197-EHc and EHc-CRM197)induced higher levels of anti-CRM197 antibodies,and the mice vaccinated with EHc-CRM197 also generated strongest anti-EHc antibodies.Consequently,as a carrier molecule in the fusion protein vaccine,EHc enhances the immunogenicity of CRM197 molecules.Likewise,CRM197 boosts the immunogenicity of EHc in the EHc-CRM197 fusion protein.
3.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
4.Analysis of T7 RNA Polymerase: From Structure-function Relationship to dsRNA Challenge and Biotechnological Applications
Wei-Chen NING ; Yu HUA ; Hui-Ling YOU ; Qiu-Shi LI ; Yao WU ; Yun-Long LIU ; Zhen-Xin HU
Progress in Biochemistry and Biophysics 2025;52(9):2280-2294
T7 RNA polymerase (T7 RNAP) is one of the simplest known RNA polymerases. Its unique structural features make it a critical model for studying the mechanisms of RNA synthesis. This review systematically examines the static crystal structure of T7 RNAP, beginning with an in-depth examination of its characteristic “thumb”, “palm”, and “finger” domains, which form the classic “right-hand-like” architecture. By detailing these structural elements, this review establishes a foundation for understanding the overall organization of T7 RNAP. This review systematically maps the functional roles of secondary structural elements and their subdomains in transcriptional catalysis, progressively elucidating the fundamental relationships between structure and function. Further, the intrinsic flexibility of T7 RNAP and its applications in research are also discussed. Additionally, the review presents the structural diagrams of the enzyme at different stages of the transcription process, and through these diagrams, it provides a detailed description of the complete transcription process of T7 RNAP. By integrating structural dynamics and kinetics analyses, the review constructs a comprehensive framework that bridges static structure to dynamic processes. Despite its advantages, T7 RNAP has a notable limitation: it generates double-stranded RNA (dsRNA) as a byproduct. The presence of dsRNA not only compromises the purity of mRNA products but also elicits nonspecific immune responses, which pose significant challenges for biotechnological and therapeutic applications. The review provides a detailed exploration of the mechanisms underlying dsRNA formation during T7 RNAP catalysis, reviews current strategies to mitigate this issue, and highlights recent progress in the field. A key focus is the semi-rational design of T7 RNAP mutants engineered to minimize dsRNA generation and enhance catalytic performance. Beyond its role in transcription, T7 RNAP exhibits rapid development and extensive application in fields, including gene editing, biosensing, and mRNA vaccines. This review systematically examines the structure-function relationships of T7 RNAP, elucidates the mechanisms of dsRNA formation, and discusses engineering strategies to optimize its performance. It further explores the engineering optimization and functional expansion of T7 RNAP. Furthermore, this review also addresses the pressing issues that currently need resolution, discusses the major challenges in the practical application of T7 RNAP, and provides an outlook on potential future research directions. In summary, this review provides a comprehensive analysis of T7 RNAP, ranging from its structural architecture to cutting-edge applications. We systematically examine: (1) the characteristic right-hand domains (thumb, palm, fingers) that define its minimalistic structure; (2) the structure-function relationships underlying transcriptional catalysis; and (3) the dynamic transitions during the complete transcription cycle. While highlighting T7 RNAP’s versatility in gene editing, biosensing, and mRNA vaccine production, we critically address its major limitation—dsRNA byproduct formation—and evaluate engineering solutions including semi-rationally designed mutants. By synthesizing current knowledge and identifying key challenges, this work aims to provide novel insights for the development and application of T7 RNAP and to foster further thought and progress in related fields.
5.Study on the factors influencing clinicians'use of innovative medical technologies:A case study of innovative oncology treatment technologies
Wen CHEN ; Zeng-hui QIU ; Shan-shan YIN ; Lan YAO
Chinese Journal of Health Policy 2024;17(12):68-75
Objective:To explore the factors influencing clinicians'adoption of new medical technologies and provide data and strategic support to promote the clinical application of innovative medical technologies.Methods:Based on the Unified Theory of Acceptance and Use of Technology ( UTAUT),a model was constructed to examine the factors influencing clinicians'adoption of new medical technologies.The model was revised through expert interviews,and data were collected via a survey questionnaire.Structural equation modeling ( SEM) was conducted using AMOS software to test both the direct and mediating effects.Results:Clinical performance expectancy ( P<0.001 ),DRG/DIP policy impact ( P=0.009 ),patient willingness ( P<0.001 ),and facilitating conditions ( P<0.001 ) had significant direct effects on usage intention.Usage intention ( P=0.005 ),patient willingness ( P=0.021 ),and facilitating conditions ( P<0.001 ) had significant direct effects on usage behavior.Usage intention mediated the relationship between clinical performance expectancy ( P<0.001 ),DRG/DIP policy impact ( P=0.030 ),patient willingness ( P<0.001 ),facilitating conditions ( P<0.001 ),and usage behavior.Conclusions:Clinical performance expectancy is the primary factor influencing clinicians'willingness to adopt new medical technologies.DRG/DIP payment methods somewhat reduce usage intention,while facilitating conditions are the key factor influencing usage behavior.Policy recommendations should focus on these key factors to promote the clinical application of innovative medical technologies.
6.A phase I dose-finding trial of hyperthermic intraperitoneal docetaxel combined with cisplatin in patients with advanced-stage ovarian cancer
Zhi-yao YOU ; Miao-fang WU ; Hui LI ; Yan-fang YE ; Li-juan WANG ; Zhong-qiu LIN ; Jing LI
Journal of Gynecologic Oncology 2024;35(1):e1-
Objective:
To identify the maximum tolerated dose (MTD) of docetaxel combined with a fixed dose of cisplatin (75 mg/m 2 ) delivered as hyperthermic intraperitoneal chemotherapy (HIPEC) in patients with ovarian cancer.
Methods:
In this phase I trial, a time-to-event Bayesian optimal interval design was used.Docetaxel was given at a starting dose of 60 mg/m2 and was increased in 5 mg/m2 increments until the MTD was determined or the maximum dose level of 75 mg/m2 was reached. The doselimiting toxicity (DLT) rate was set at 25%, with a total sample size of 30 patients. HIPEC was delivered immediately following debulking surgery at a target temperature of 43°C for 90 minutes.
Results:
From August 2022 to November 2022, 30 patients were enrolled. Among the patients who received a dose of docetaxel ≤65 mg/m2 , no DLT was reported. DLTs were observed in one patient who received 70 mg/m2 docetaxel (grade 3 anaemia) and in three patients who received 75 mg/m2 docetaxel (one case of grade 3 anaemia, one case of grade 3 hepatic impairment and one case of grade 4 thrombocytopenia). Patients treated with docetaxel 75 mg/m2 in combination with cisplatin 75 mg/m2 had an estimated DLT rate of 25%, which was the closest to the target DLT rate and was therefore chosen as the MTD.
Conclusion
Docetaxel, in combination with a fixed dose of cisplatin (75 mg/m2), can be used safely at intraperitoneal doses of 75 mg/m2 in ovarian cancer patients who received HIPEC (43°C, 90 minutes) following debulking surgery.
7.A phase I dose-finding trial of hyperthermic intraperitoneal docetaxel combined with cisplatin in patients with advanced-stage ovarian cancer
Zhi-yao YOU ; Miao-fang WU ; Hui LI ; Yan-fang YE ; Li-juan WANG ; Zhong-qiu LIN ; Jing LI
Journal of Gynecologic Oncology 2024;35(1):e1-
Objective:
To identify the maximum tolerated dose (MTD) of docetaxel combined with a fixed dose of cisplatin (75 mg/m 2 ) delivered as hyperthermic intraperitoneal chemotherapy (HIPEC) in patients with ovarian cancer.
Methods:
In this phase I trial, a time-to-event Bayesian optimal interval design was used.Docetaxel was given at a starting dose of 60 mg/m2 and was increased in 5 mg/m2 increments until the MTD was determined or the maximum dose level of 75 mg/m2 was reached. The doselimiting toxicity (DLT) rate was set at 25%, with a total sample size of 30 patients. HIPEC was delivered immediately following debulking surgery at a target temperature of 43°C for 90 minutes.
Results:
From August 2022 to November 2022, 30 patients were enrolled. Among the patients who received a dose of docetaxel ≤65 mg/m2 , no DLT was reported. DLTs were observed in one patient who received 70 mg/m2 docetaxel (grade 3 anaemia) and in three patients who received 75 mg/m2 docetaxel (one case of grade 3 anaemia, one case of grade 3 hepatic impairment and one case of grade 4 thrombocytopenia). Patients treated with docetaxel 75 mg/m2 in combination with cisplatin 75 mg/m2 had an estimated DLT rate of 25%, which was the closest to the target DLT rate and was therefore chosen as the MTD.
Conclusion
Docetaxel, in combination with a fixed dose of cisplatin (75 mg/m2), can be used safely at intraperitoneal doses of 75 mg/m2 in ovarian cancer patients who received HIPEC (43°C, 90 minutes) following debulking surgery.
8.A phase I dose-finding trial of hyperthermic intraperitoneal docetaxel combined with cisplatin in patients with advanced-stage ovarian cancer
Zhi-yao YOU ; Miao-fang WU ; Hui LI ; Yan-fang YE ; Li-juan WANG ; Zhong-qiu LIN ; Jing LI
Journal of Gynecologic Oncology 2024;35(1):e1-
Objective:
To identify the maximum tolerated dose (MTD) of docetaxel combined with a fixed dose of cisplatin (75 mg/m 2 ) delivered as hyperthermic intraperitoneal chemotherapy (HIPEC) in patients with ovarian cancer.
Methods:
In this phase I trial, a time-to-event Bayesian optimal interval design was used.Docetaxel was given at a starting dose of 60 mg/m2 and was increased in 5 mg/m2 increments until the MTD was determined or the maximum dose level of 75 mg/m2 was reached. The doselimiting toxicity (DLT) rate was set at 25%, with a total sample size of 30 patients. HIPEC was delivered immediately following debulking surgery at a target temperature of 43°C for 90 minutes.
Results:
From August 2022 to November 2022, 30 patients were enrolled. Among the patients who received a dose of docetaxel ≤65 mg/m2 , no DLT was reported. DLTs were observed in one patient who received 70 mg/m2 docetaxel (grade 3 anaemia) and in three patients who received 75 mg/m2 docetaxel (one case of grade 3 anaemia, one case of grade 3 hepatic impairment and one case of grade 4 thrombocytopenia). Patients treated with docetaxel 75 mg/m2 in combination with cisplatin 75 mg/m2 had an estimated DLT rate of 25%, which was the closest to the target DLT rate and was therefore chosen as the MTD.
Conclusion
Docetaxel, in combination with a fixed dose of cisplatin (75 mg/m2), can be used safely at intraperitoneal doses of 75 mg/m2 in ovarian cancer patients who received HIPEC (43°C, 90 minutes) following debulking surgery.
9.Trends in age-, period- and cohort-specific incidence of hepatitis C in Chifeng City from 2008 to 2022
LI Wenjun ; LI Hui ; YANG Jingyuan ; YANG Hong ; GAO Ya ; GAO Baicheng ; LI Yao ; ZHANG Qiyue ; QIU Yafei
Journal of Preventive Medicine 2024;36(6):514-517,522
Objective:
To explore incidence trend of hepatitis C in Chifeng City, Inner Mongolia Autonomous Region from 2008 to 2022, so as to provide the basis for formulating prevention and control measures for hepatitis C.
Methods:
Data of reported hepatitis C cases in Chifeng City from 2008 to 2022 was collected through the Infectious Disease Information Reporting Management System. Trends in incidence of hepatitis C were analyzed using annual percent change (APC) and average annual percent change (AAPC). Impact of age, period and birth cohort on the risk of developing hepatitis C were analyzed by an age-period-cohort model.
Results:
The annual average reported incidence rate of hepatitis C in Chifeng City was 59.13/105 from 2008 to 2022. The incidence showed an upward trend from 2008 to 2018 (APC=9.405%, P<0.05) and a downward trend from 2018 to 2022 (APC=-17.475%, P<0.05), but the overall trend was not statistically significant (AAPC=0.937%, P>0.05). The age-period-cohort model analysis showed that the incidence risks of hepatitis C in the residents aged 0 to 4 years and 45 to 84 years were higher than those in the residents aged 40 to 44 years (the control group). The incidence risk of hepatitis C increased with age from 40 to 79 years. Compared with 2008-2012, the incidence risk of hepatitis C showed an increasing trend followed by a decline in 2008-2022. The incidence risk was higher in 2013-2017 and lower in 2018-2022 than in 2008-2012. The incidence risk of hepatitis C showed an increasing trend followed by a decreasing trend by using the birth cohort from 1968 to 1972 as the control. The birth cohort from 1953 to 1977 had a higher incidence risk of hepatitis C than other birth cohorts.
Conclusions
The overall incidence of hepatitis C in Chifeng City from 2008 to 2022 appeared a tendency towards a decline, and the incidence risk increased with age. Screening and health education for the elderly and high-risk birth cohorts should be strengthened.
10.Expert consensus on digital intraoral scanning technology
Jie YOU ; Wenjuan YAN ; Liting LIN ; Wen-Zhen GU ; Yarong HOU ; Wei XIAO ; Hui YAO ; Yaner LI ; Lihui MA ; Ruini ZHAO ; Junqi QIU ; Jianzhang LIU ; Yi ZHOU
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(8):569-577
Digital intraoral scanning is a hot topic in the field of oral digital technology.In recent years,digital intra-oral scanning has gradually become the mainstream technology in orthodontics,prosthodontics,and implant dentistry.The precision of digital intraoral scanning and the accuracy and stitching of data collection are the keys to the success of the impression.However,the operators are less familiar with the intraoral scanning characteristics,imaging process-ing,operator scanning method,oral tissue specificity of the scanned object,and restoration design.Thus far,no unified standard and consensus on digital intraoral scanning technology has been achieved at home or abroad.To deal with the problems encountered in oral scanning and improve the quality of digital scanning,we collected common expert opin-ions and sought to expound the causes of scanning errors and countermeasures by summarizing the existing evidence.We also describe the scanning strategies under different oral impression requirements.The expert consensus is that due to various factors affecting the accuracy of digital intraoral scanning and the reproducibility of scanned images,adopting the correct scanning trajectory can shorten clinical operation time and improve scanning accuracy.The scanning trajec-tories mainly include the E-shaped,segmented,and S-shaped methods.When performing fixed denture restoration,it is recommended to first scan the abutment and adjacent teeth.When performing fixed denture restoration,it is recommend-ed to scan the abutment and adjacent teeth first.Then the cavity in the abutment area is excavated.Lastly,the cavity gap was scanned after completing the abutment preparation.This method not only meets clinical needs but also achieves the most reliable accuracy.When performing full denture restoration in edentulous jaws,setting markers on the mucosal tissue at the bottom of the alveolar ridge,simultaneously capturing images of the vestibular area,using different types of scanning paths such as Z-shaped,S-shaped,buccal-palatal and palatal-buccal pathways,segmented scanning of dental arches,and other strategies can reduce scanning errors and improve image stitching and overlap.For implant restora-tion,when a single crown restoration is supported by implants and a small span upper structure restoration,it is recom-mended to first pre-scan the required dental arch.Then the cavity in the abutment area is excavated.Lastly,scanning the cavity gap after installing the implant scanning rod.When repairing a bone level implant crown,an improved indi-rect scanning method can be used.The scanning process includes three steps:First,the temporary restoration,adjacent teeth,and gingival tissue in the mouth are scanned;second,the entire dental arch is scanned after installing a standard scanning rod on the implant;and third,the temporary restoration outside the mouth is scanned to obtain the three-di-mensional shape of the gingival contour of the implant neck,thereby increasing the stability of soft tissue scanning around the implant and improving scanning restoration.For dental implant fixed bridge repair with missing teeth,the mobility of the mucosa increases the difficulty of scanning,making it difficult for scanners to distinguish scanning rods of the same shape and size,which can easily cause image stacking errors.Higher accuracy of digital implant impres-sions can be achieved by changing the geometric shape of the scanning rods to change the optical curvature radius.The consensus confirms that as the range of scanned dental arches and the number of data concatenations increases,the scanning accuracy decreases accordingly,especially when performing full mouth implant restoration impressions.The difficulty of image stitching processing can easily be increased by the presence of unstable and uneven mucosal mor-phology inside the mouth and the lack of relatively obvious and fixed reference objects,which results in insufficient ac-curacy.When designing restorations of this type,it is advisable to carefully choose digital intraoral scanning methods to obtain model data.It is not recommended to use digital impressions when there are more than five missing teeth.


Result Analysis
Print
Save
E-mail