1.Effect of red laser and plasma transurethral enucleation of prostate on urinary function and sexual function in patients with benign prostatic hyperplasia under 65 years old
Binbin ZHANG ; Lingling DU ; Hongxiong SONG ; Yantao DANG ; Wenshuai YAN ; Jixue GAO ; Feng WANG ; Lijun MA ; Longqiang LIU
Clinical Medicine of China 2025;41(6):465-470
Objective:To investigate the effects of red laser versus plasma transurethral enucleation of the prostate (TUEP) on urinary and sexual function in patients under 65 years of age with benign prostatic hyperplasia (BPH).Method:This study was a retrospective analysis. Eighty BPH patients under 65 years old, admitted to the Affiliated Hospital of Yan'an University between January 2020 and January 2023 were selected. Among them, 40 patients who underwent 980 nm semiconductor red laser TUERP with pre-resection of the urethral mucosa 1 cm proximal to the verumontanum at the prostatic apex and preservation of bladder neck integrity were assigned to the Red Laser Group. Another 40 patients who underwent conventional TURP with a plasma resectoscope were assigned to the Plasma Group. Clinical data and 6-month postoperative follow-up data were collected. Changes in the International Prostate Symptom Score (IPSS), maximum urinary flow rate (Qmax), International Index of Erectile Function-5 (IIEF-5) score, ejaculatory function score, and ejaculatory discomfort score before and after surgery were compared between the two groups. The incidence rates of decreased semen volume, retrograde ejaculation, and painful ejaculation at 6 months postoperatively were also compared.Results:At 6 months postoperatively, IPSS decreased in both groups compared to preoperative levels and was lower in the Red Laser Group than in the Plasma Group [(4.7±1.3) points vs. (6.3±2.2) points, t=-4.46, P<0.001]. Qmax increased in both groups compared to preoperative levels and was higher in the Red Laser Group than in the Plasma Group [(25.7±1.3) ml/s vs. (22.6±1.2) ml/s, t=10.76, P<0.001]. The ejaculatory function score in the Plasma Group was lower than its own preoperative level [(5.9±0.7) points vs. (11.1±1.6) points, t=5.33, P<0.001] and lower than that in the Red Laser Group [(5.9±0.7) points vs. (11.4±0.9) points, t=7.56, P<0.001]. The ejaculatory discomfort score in the Plasma Group was higher than its own preoperative level [(3.0±1.5) points vs. (0.8±0.6) points, t=4.26, P<0.001] and higher than that in the Red Laser Group [(3.0±1.5) points vs. (0.8±0.6) points, t=5.83, P<0.001]. The incidence rates of decreased semen volume and retrograde ejaculation in the Red Laser Group were lower than those in the Plasma Group [12.5% (5/40) vs. 50.0% (20/40), 10.0% (4/40) vs. 45.0% (18/40), χ2=15.84, 12.65, respectively, both P<0.001]. Conclusions:Using 980 nm semiconductor red laser TUERP with pre-resection of the urethral mucosa 1 cm proximal to the verumontanum and preservation of bladder neck integrity can improve urinary and sexual function in BPH patients under 65 years of age.
2.Consistency of MSCT 3D processing technique and QCT in measuring BMD for lumbar vertebra
Xiangming LI ; Lixin ZHANG ; Weifeng WANG ; Yaqun KONG ; Chensi XU ; Wanbo ZHOU ; Shunsheng AI ; Lixiang SONG ; Yantao NIU
China Medical Equipment 2025;22(4):28-33
Objective:To study the consistency between post-processing bone mineral density(BMD)values of multi-slice spiral computed tomography(MSCT)scan and the BMD value of quantitative computed tomography(QCT)for lumbar vertebra,so as to explore the feasibility of utilizing MSCT scan-based post-processing BMD values for lumbar vertebra in clinical practice.Methods:The MSCT equipment and QCT equipment were respectively adopted to conduct imaging scan for the L2-L4 of lumber vertebra of QRM-ESP145 European Spine Phantom(ESP),and L2-L4 of lumbar vertebra of adult sheep,and L2-L4 of lumbar vertebra of adult volunteer.The L2-L4 of ESP lumber vertebra and L2-L4 of lumbar vertebra of adult sheep were scanned respectively MSCT and QCT for three times,so as to measure BMD values.The L2-L4 of lumbar vertebrae of volunteers were scanned respectively by the two methods for one time according to the standard of clinical examination,which were reconstructed by three times so as to obtain mean of them.The BMD values of QCT scan were set as control group,and the BMD values of MSCT scan were set as experiment group.The experiment group was further divided into experiment 1 group[two dimension(2D)regional volumetric BMD values of the lumbar vertebra]and experiment 2 group[three dimension(3D)global volumetric BMD post-processing of the lumbar vertebra]according to the reliability of experiment.Then,the consistency between the MSCT 3D post-processing BMD values of three groups and QCT-measured BMD values was compared and analyzed.Results:The MSCT 3D post-processing BMD values of L2-L4 of ESP lumbar vertebra of three groups were respectively(120.83±0.97),(199.57±0.54)and(119.19±1.04)mg/cm3,and that of L2-L4 of lumbar vertebra of adult sheep of three groups were respectively(414.89±1.72),(410.50±0.77)and(420.25±2.71)mg/cm3,and that of L2-L4 of lumbar vertebra of volunteer were respectively(141.22±0.09),(137.38±0.37)and(152.03±1.03)mg/cm3.There were not statistically significant differences in BMD values between MSCT examination and QCT examination(P>0.05).Conclusion:MSCT 3D post-processing BMD values on lumbar vertebra has high consistency with that of QCT measurements,which post-processing technique can replace QCT to conduct BMD examination,and reduce unnecessary radiation exposure and examination costs for patients.
3.Consistency of MSCT 3D processing technique and QCT in measuring BMD for lumbar vertebra
Xiangming LI ; Lixin ZHANG ; Weifeng WANG ; Yaqun KONG ; Chensi XU ; Wanbo ZHOU ; Shunsheng AI ; Lixiang SONG ; Yantao NIU
China Medical Equipment 2025;22(4):28-33
Objective:To study the consistency between post-processing bone mineral density(BMD)values of multi-slice spiral computed tomography(MSCT)scan and the BMD value of quantitative computed tomography(QCT)for lumbar vertebra,so as to explore the feasibility of utilizing MSCT scan-based post-processing BMD values for lumbar vertebra in clinical practice.Methods:The MSCT equipment and QCT equipment were respectively adopted to conduct imaging scan for the L2-L4 of lumber vertebra of QRM-ESP145 European Spine Phantom(ESP),and L2-L4 of lumbar vertebra of adult sheep,and L2-L4 of lumbar vertebra of adult volunteer.The L2-L4 of ESP lumber vertebra and L2-L4 of lumbar vertebra of adult sheep were scanned respectively MSCT and QCT for three times,so as to measure BMD values.The L2-L4 of lumbar vertebrae of volunteers were scanned respectively by the two methods for one time according to the standard of clinical examination,which were reconstructed by three times so as to obtain mean of them.The BMD values of QCT scan were set as control group,and the BMD values of MSCT scan were set as experiment group.The experiment group was further divided into experiment 1 group[two dimension(2D)regional volumetric BMD values of the lumbar vertebra]and experiment 2 group[three dimension(3D)global volumetric BMD post-processing of the lumbar vertebra]according to the reliability of experiment.Then,the consistency between the MSCT 3D post-processing BMD values of three groups and QCT-measured BMD values was compared and analyzed.Results:The MSCT 3D post-processing BMD values of L2-L4 of ESP lumbar vertebra of three groups were respectively(120.83±0.97),(199.57±0.54)and(119.19±1.04)mg/cm3,and that of L2-L4 of lumbar vertebra of adult sheep of three groups were respectively(414.89±1.72),(410.50±0.77)and(420.25±2.71)mg/cm3,and that of L2-L4 of lumbar vertebra of volunteer were respectively(141.22±0.09),(137.38±0.37)and(152.03±1.03)mg/cm3.There were not statistically significant differences in BMD values between MSCT examination and QCT examination(P>0.05).Conclusion:MSCT 3D post-processing BMD values on lumbar vertebra has high consistency with that of QCT measurements,which post-processing technique can replace QCT to conduct BMD examination,and reduce unnecessary radiation exposure and examination costs for patients.
4.Effect of red laser and plasma transurethral enucleation of prostate on urinary function and sexual function in patients with benign prostatic hyperplasia under 65 years old
Binbin ZHANG ; Lingling DU ; Hongxiong SONG ; Yantao DANG ; Wenshuai YAN ; Jixue GAO ; Feng WANG ; Lijun MA ; Longqiang LIU
Clinical Medicine of China 2025;41(6):465-470
Objective:To investigate the effects of red laser versus plasma transurethral enucleation of the prostate (TUEP) on urinary and sexual function in patients under 65 years of age with benign prostatic hyperplasia (BPH).Method:This study was a retrospective analysis. Eighty BPH patients under 65 years old, admitted to the Affiliated Hospital of Yan'an University between January 2020 and January 2023 were selected. Among them, 40 patients who underwent 980 nm semiconductor red laser TUERP with pre-resection of the urethral mucosa 1 cm proximal to the verumontanum at the prostatic apex and preservation of bladder neck integrity were assigned to the Red Laser Group. Another 40 patients who underwent conventional TURP with a plasma resectoscope were assigned to the Plasma Group. Clinical data and 6-month postoperative follow-up data were collected. Changes in the International Prostate Symptom Score (IPSS), maximum urinary flow rate (Qmax), International Index of Erectile Function-5 (IIEF-5) score, ejaculatory function score, and ejaculatory discomfort score before and after surgery were compared between the two groups. The incidence rates of decreased semen volume, retrograde ejaculation, and painful ejaculation at 6 months postoperatively were also compared.Results:At 6 months postoperatively, IPSS decreased in both groups compared to preoperative levels and was lower in the Red Laser Group than in the Plasma Group [(4.7±1.3) points vs. (6.3±2.2) points, t=-4.46, P<0.001]. Qmax increased in both groups compared to preoperative levels and was higher in the Red Laser Group than in the Plasma Group [(25.7±1.3) ml/s vs. (22.6±1.2) ml/s, t=10.76, P<0.001]. The ejaculatory function score in the Plasma Group was lower than its own preoperative level [(5.9±0.7) points vs. (11.1±1.6) points, t=5.33, P<0.001] and lower than that in the Red Laser Group [(5.9±0.7) points vs. (11.4±0.9) points, t=7.56, P<0.001]. The ejaculatory discomfort score in the Plasma Group was higher than its own preoperative level [(3.0±1.5) points vs. (0.8±0.6) points, t=4.26, P<0.001] and higher than that in the Red Laser Group [(3.0±1.5) points vs. (0.8±0.6) points, t=5.83, P<0.001]. The incidence rates of decreased semen volume and retrograde ejaculation in the Red Laser Group were lower than those in the Plasma Group [12.5% (5/40) vs. 50.0% (20/40), 10.0% (4/40) vs. 45.0% (18/40), χ2=15.84, 12.65, respectively, both P<0.001]. Conclusions:Using 980 nm semiconductor red laser TUERP with pre-resection of the urethral mucosa 1 cm proximal to the verumontanum and preservation of bladder neck integrity can improve urinary and sexual function in BPH patients under 65 years of age.
5.Clinical study of 980 nm semiconductor laser preablation of urethra mucosa in prostatic tip in small volume benign prostatic hyperplasia laser vaporization
Binbin ZHANG ; Lingling DU ; Xiaolong HE ; Yantao DANG ; Wenshuai YAN ; Jixue GAO ; Yi LI ; Lijun MA ; Hongxiong SONG
International Journal of Surgery 2024;51(11):752-758
Objective:To investigate the effect of 980 nm semiconductor laser preablation of urethra mucosa at the prostatic tip in small volume benign prostatic hyperplasia (BPH).Methods:The case data of 120 patients diagnosed with small volume BPH in the Yan′an University Affiliated Hospital from June 2020 to June 2022 were retrospectively analyzed, and they were divided into improved group and conventional group according to different treatment methods, with 60 cases in each group. Patients in the improved group were treated with 980 nm semiconductor laser preablation of urethra mucosa at the prostatic tip, and patients in the conventional group were treated with 980 nm semiconductor laser vaporization of prostate. The sexual function of the patients was evaluated by the international erectile function index-5(IIEF-5) score, erectile hardness score (EHS) and retrograde ejaculation before surgery and 1, 3, 6, and 12 months after surgery. International prostate symptom scale (IPSS), quality of life (QOL) score, the maximum urine flow rate (Qmax) and postvoid residual urine (PVR) were used to evaluate urinary control function. The incidence of urinary incontinence, bladder neck contracture and other complications were compared between the two groups. Measurement data were expressed as mean±standard deviation ( ± s), and t-test was used for comparison between groups. The count data were expressed as cases and percentage, and Chi-square test was used for comparison between groups. Results:There was no significant difference in PVR, Qmax, IPSS score, QOL score, IIEF-5 score and EHS score between two groups ( P>0.05). In terms of PVR, Qmax, IPSS score, QOL score, IIEF-5 score and EHS score at 1, 3, 6 and 12 months after surgery, all these parameters were significantly improved compared with the preoperative, the differences were statistically significant ( P< 0.05). However, there was no significant difference between the two groups ( P> 0.05). There was no significant difference in IIEF-5 score and EHS score between the two groups during postoperative follow-up and before and after operation ( P> 0.05). The incidence of retrograde ejaculation rate in the improved group was lower than that in the conventional group during the follow-up 1, 3, 6 months after surgery, and the difference was statistically significant ( P<0.05). In the follow-up 1, 3 months after surgery, the incidence of stress urinary incontinence in the improved group was lower than that in the conventional group, the differences were statistically significant ( P< 0.05). At follow-up 6, 12 months after surgery, the rates of stress urinary incontinence were similar between the two groups, and the difference was not statistically significant ( P> 0.05). In the follow-up 12 months after surgery, there were 2 cases (3.33%) of bladder and neck contracture in the improved group, and 8 cases (13.33%) in the conventional group, the difference was statistically significant ( P<0.05). Conclusions:The effect of 980 nm semiconductor laser preablation of urethra mucosa at the prostatic tip in small volume BPH patients is similar to that of conventional vaporization, and the operation time is short. At the same time, the proximal 1 cm tissue of the verticulae and the integrity of the bladder neck are preserved, and the internal and external sphincter of the urethra are protected, thus improving the immediate postoperative urinary control rate and the incidence of retrograde ejaculation in small volume BPH patients.
6.The cutoff value of small airway dysfunction in children with bronchial asthma
Wei CHEN ; Zhe YANG ; Chuanhe LIU ; Xinyu JIA ; Yantao ZHANG ; Xin SONG ; Shuo LI
Chinese Journal of Pediatrics 2024;62(3):245-249
Objective:To explore the cutoff value for assessing small airway dysfunction in children with asthma.Methods:A total of 364 asthmatic children aged 5 to 14 years, with normal ventilatory function, followed up at the Asthma Clinic of the Children′s Hospital of Capital Institute of Pediatrics from January 2017 to January 2018, were selected as the case group. Concurrently, 403 healthy children of the same age range and without any symptoms in the community were chosen as the control group, and pulmonary function tests were conducted. The values of forced expiratory volume in 1 second (FEV 1), forced vital capacity (FVC), forced expiratory flow at 50% of FVC (FEF 50), forced expiratory flow at 75% of FVC (FEF 75) and maximum mid-expiratory flow (MMEF) were compared between case group and control group. Statistical tests such as t-test, χ2 test, or Mann-Whitney U test were used to analyze the differences between the groups. Receiver operating characteristic (ROC) curves were constructed, and the maximum Youden Index was utilized to determine the optimal cutoff values and thresholds for identifying small airway dysfunction in asthmatic children. Results:This study comprised 364 children in the case group (220 boys and 144 girls) and 403 children in the control group (198 boys and 205 girls). The small airway parameters (FEF 50%pred, FEF 75%pred, MMEF%pred) in the asthmatic group were significantly lower than in the control group (77% (69%, 91%) vs. 95% (83%, 109%), 67% (54%, 82%) vs. 84% (70%, 102%), 76% (66%, 90%) vs. 97% (86%, 113%), Z=12.03, 11.35, 13.66, all P<0.001). The ROC curve area under the curve for FEF 50%pred, FEF 75%pred, MMEF%pred was 0.75, 0.74, and 0.79, respectively. Using a cutoff value of 80% for FEF 50%pred achieved a sensitivity of 56.9% and specificity of 81.4%. A cutoff value of 74% for FEF 75%pred resulted in a sensitivity of 67.3% and specificity of 69.2%. Finally, using a cutoff value of 84% for MMEF%pred achieved a sensitivity of 67.9% and specificity of 77.2%. Conclusion:In the presence of normal ventilatory function, utilizing FEF 50<80% predicted or MMEF<84% predicted can accurately serve as criteria for identifying small airway dysfunction in children with controlled asthma.
7.Longitudinal proteomic investigation of COVID-19 vaccination.
Yingrui WANG ; Qianru ZHU ; Rui SUN ; Xiao YI ; Lingling HUANG ; Yifan HU ; Weigang GE ; Huanhuan GAO ; Xinfu YE ; Yu SONG ; Li SHAO ; Yantao LI ; Jie LI ; Tiannan GUO ; Junping SHI
Protein & Cell 2023;14(9):668-682
Although the development of COVID-19 vaccines has been a remarkable success, the heterogeneous individual antibody generation and decline over time are unknown and still hard to predict. In this study, blood samples were collected from 163 participants who next received two doses of an inactivated COVID-19 vaccine (CoronaVac®) at a 28-day interval. Using TMT-based proteomics, we identified 1,715 serum and 7,342 peripheral blood mononuclear cells (PBMCs) proteins. We proposed two sets of potential biomarkers (seven from serum, five from PBMCs) at baseline using machine learning, and predicted the individual seropositivity 57 days after vaccination (AUC = 0.87). Based on the four PBMC's potential biomarkers, we predicted the antibody persistence until 180 days after vaccination (AUC = 0.79). Our data highlighted characteristic hematological host responses, including altered lymphocyte migration regulation, neutrophil degranulation, and humoral immune response. This study proposed potential blood-derived protein biomarkers before vaccination for predicting heterogeneous antibody generation and decline after COVID-19 vaccination, shedding light on immunization mechanisms and individual booster shot planning.
Humans
;
COVID-19 Vaccines
;
Leukocytes, Mononuclear
;
Proteomics
;
COVID-19/prevention & control*
;
Vaccination
;
Antibodies
;
Antibodies, Viral
;
Antibodies, Neutralizing
8.Study on image quality optimization of abdominal digital radiography with different additional filters
Yan SUI ; Dewu YANG ; Xunru LI ; Junfeng SONG ; Kang LIU ; Zhaorui CHEN ; Yantao NIU
Chinese Journal of Radiological Medicine and Protection 2021;41(7):519-523
Objective:To investigate the effect of different additional filters on the image quality and radiation dose in abdominaldigital radiography (DR).Methods:Retrospective analysis was performed on 10 cases of abdominal DR from December 2020 to January 2021 in Fuxing Hospital, and the average mAs was calculated. Using automatic exposure control (AEC) technology, a polymethyl methacrylate (PMMA) slab of the corresponding thickness (18 cm) at the same output of above mAs was confirmed and used as the attenuator to simulate the abdomen. The phantom of CDRAD 2.0 and 17 slices of 10 mm thick PMMA plates (total thickness 18 cm) were placed on the bed. The additional filters were selected as no additional filter, 2 mmAl, 0.1 mmCu+ 1 mmAl, 0.1 mmCu+ 2 mmAl respectively. The AEC levels were selected at -2, -1, 0, 1, and 2 respectively. The images were collected and analyzed by using CDRAD 2.0 software to obtain the image quality factor (IQF inv). The incident air kinetic energy on the surface of the PPMA was measured for each exposure, and PCXMC software was used to estimate the organ dose and effective dose, and a comparative analysis was made. Results:The skin incident doses at no additional filter, 2 mmAl, 0.1 mmCu+ 1 mmAl, 0.1 mmCu+ 2 mm Al were (0.546 1±0.200 8), (0.376 2±0.133 8 ), (0.285 3±0.100 1) and (0.289 9±0.099 2) mGy, respectively. The estimated effective doses were (79.63±29.24)×10 -3, (71.05±25.56)×10 -3, (63.58±22.18)×10 -3 and (67.64±23.11)×10 -3 mSv, respectively. The gonadal doses were (0.058 1±0.020 8), (0.050 0±0.018 0), (0.044 8±0.015 6) and (0.047 7±0.016 3) mGy.The IQF inv values were 4.70±0.61, 4.80±0.84, 4.60±0.55, 4.60±0.60, respectively. There were linear correlations between the effective dose and the skin incident dose under different additional filtration, and the effective doses increased with the increase of the incident doses. The dose was lowest at the addition filtration of 0.1 mmCu+ 1 mmAl. There was no significant difference in the IQF inv between groups( P>0.05). Conclusions:The optimal additional filtration for abdominal DR was 0.1 mmCu+ 1 mmAl with the image quality meeting the requirements of clinical diagnosis, the radiation dose reduced reasonably, and the objective of the optimization of radiographic parameters achieved.
9.Study on the level of fractional exhaled nitric oxide in healthy preschool children in Beijing
Yexuan ZHU ; Shuo LI ; Xin SONG ; Mingjun SHAO ; Yantao ZHANG ; Xinmei JIANG ; Li SHA ; Chuanhe LIU
Chinese Journal of Applied Clinical Pediatrics 2020;35(16):1244-1247
Objective:To explore the level of fractional exhaled nitric oxide (FeNO) in preschool children in Beijing and analyze the influencing factors.Methods:Preschool students aged 3-5 in Beijing were selected from May to July 2017.Healthy children were screened through questionnaire survey and on-site physical examination, and their FeNO levels were detected.Results:A total of 317 healthy children were enrolled, including 161 males and 156 females.There was no significant difference in FeNO levels between different genders ( P>0.05). The geometric mean value of FeNO was 8.2 ppb in male(95% CI: 7.0-9.3 ppb)and 8.7 ppb in female (95% CI: 7.4-10.1 ppb). There were statistical differences in FeNO levels among the 3 age groups ( F=4.63, P<0.05). The geometric mean value of FeNO was 7.2 ppb in 3-year-old children (95% CI: 5.5-8.9 ppb), 8.8 ppb in 4-year-old children (95% CI: 7.4-10.2 ppb), and 9.2 ppb in 5-year-old children (95% CI: 7.7-10.7 ppb). The geometric mean value of FeNO of healthy preschool children was 8.5 ppb (95% CI: 7.6-9.3 ppb). There was a positive correlation between FeNO and height ( r=0.135, P<0.05), but there was no significant correlation between FeNO and weight. Conclusions:The geometric mean value of FeNO in healthy preschool children in Beijing is 8.5 ppb (95% CI: 7.6-9.3 ppb)and the 95% reference value is 23.5 ppb.The level of FeNO changes slightly with the increase of age, and height also affects the FeNO.It is highly feasible to use on-line tidal breathing method to measure FeNO of preschool children.
10.Application of impulse oscillometry in the measurement for childhood bronchial hyperresponsiveness
Xiao-Fan BU ; Jing ZHAO ; Shuo LI ; Xin SONG ; Yantao ZHANG ; Chuanhe LIU ; Changyun LIU
Chinese Journal of Applied Clinical Pediatrics 2018;33(16):1233-1236
Objective To explore the effectiveness of impulse oscillometry(IOS)in airway responsiveness measurement and to find out the positive threshold of IOS for asthma diagnosis. Methods Seventy-nine children aged 6-14 years who had suspicious asthma,were recruited into the study. The positive criteria of the methacholine bron-chial provocation test was a 20% reduction in forced expiratory volume in the first second (FEV 1 )compared to base-line. Simultaneously measured changes in various parameters of IOS,including resonant frequency(Fres),impedance at 5 Hz(Zrs),resistances at 5 and 20 Hz(R5,R20),reactance at 5 Hz(X5),and area of reactance(AX). The results of the challenge test were divided into positive and negative groups according to the pulmonary ventilation function me-thod. The differences between the 2 groups of IOS parameters before and after the challenge test,and the correlation be-tween the change rate of FEV1 and the change rate of IOS parameters were compared,and the positive judgment criteria of IOS parameters in the determination of respiratory responsiveness were determined. Results The positive group of bronchial provocation test had 37 patients and negative group had 42 patients. There was no significant difference in the basic values of parameters between the positive group and the negative group (all P > 0. 05). Changes in Zrs,R5,X5 of IOS were correlated with changes in FEV1 (r = 0. 374,0. 310,0. 449,all P < 0. 05). By single factor analysis,the area under the receiver operating characteristic(ROC)carve (AUC)showed:basic value of Zrs increased by 45. 85%,R5 increased by 45. 72%,X5 increased by 80. 74% respectively compared to the baseline showed the optimal combination of sensitivity and specificity. In multivariate Logistic regression models,when Zrs and R5 were combined to measure the airway responsiveness,the sensitivity and specificity were 73. 0% and 81. 0%,respectively. Conclusions IOS and spirometry can be used to determine airway responsiveness in children during methacholine bronchial challenge. Zrs≥45. 85%,or R5≥45. 72%,or X5≥80. 74%,or Zrs and R5 of multiple regression formula can be used as the positive criteria for young children with airway heperresponsiveness,the combination of Zrs and R5 has higher sensitivity and specificity.

Result Analysis
Print
Save
E-mail