1.Guideline-driven clinical decision support for colonoscopy patients using the hierarchical multi-label deep learning method.
Junling WU ; Jun CHEN ; Hanwen ZHANG ; Zhe LUAN ; Yiming ZHAO ; Mengxuan SUN ; Shufang WANG ; Congyong LI ; Zhizhuang ZHAO ; Wei ZHANG ; Yi CHEN ; Jiaqi ZHANG ; Yansheng LI ; Kejia LIU ; Jinghao NIU ; Gang SUN
Chinese Medical Journal 2025;138(20):2631-2639
BACKGROUND:
Over 20 million colonoscopies are performed in China annually. An automatic clinical decision support system (CDSS) with accurate semantic recognition of colonoscopy reports and guideline-based is helpful to relieve the increasing medical burden and standardize the healthcare. In this study, the CDSS was built under a hierarchical-label interpretable classification framework, trained by a state-of-the-art transformer-based model, and validated in a multi-center style.
METHODS:
We conducted stratified sampling on a previously established dataset containing 302,965 electronic colonoscopy reports with pathology, identified 2041 patients' records representative of overall features, and randomly divided into the training and testing sets (7:3). A total of five main labels and 22 sublabels were applied to annotate each record on a network platform, and the data were trained respectively by three pre-training models on Chinese corpus website, including bidirectional encoder representations from transformers (BERT)-base-Chinese (BC), the BERT-wwm-ext-Chinese (BWEC), and ernie-3.0-base-zh (E3BZ). The performance of trained models was subsequently compared with a randomly initialized model, and the preferred model was selected. Model fine-tuning was applied to further enhance the capacity. The system was validated in five other hospitals with 3177 consecutive colonoscopy cases.
RESULTS:
The E3BZ pre-trained model exhibited the best performance, with a 90.18% accuracy and a 69.14% Macro-F1 score overall. The model achieved 100% accuracy in identifying cancer cases and 99.16% for normal cases. In external validation, the model exhibited favorable consistency and good performance among five hospitals.
CONCLUSIONS
The novel CDSS possesses high-level semantic recognition of colonoscopy reports, provides appropriate recommendations, and holds the potential to be a powerful tool for physicians and patients. The hierarchical multi-label strategy and pre-training method should be amendable to manage more medical text in the future.
Humans
;
Colonoscopy/methods*
;
Deep Learning
;
Decision Support Systems, Clinical
;
Female
;
Male
2.Progress in soluble secreted form of hepatitis E virus ORF2 protein
Chinese Journal of Microbiology and Immunology 2025;45(2):149-155
The genome of hepatitis E virus (HEV) contains three open reading frames (ORF1-3), among which ORF2 encodes the viral capsid protein. It has been believed that ORF2 only encodes the structural protein for assembling the capsid of HEV virion. However, recent findings have revealed that during HEV replication, ORF2 also produces a substantial amount of glycosylated soluble protein secreted outside the host cells, known as the ORF2 secreted form (ORF2S). Although not involved in virion assembly, the soluble secreted form of ORF2 protein may play a crucial role in HEV infection and pathogenesis. This review presents an overview of research progress in HEV ORF2S.
3.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
4.GBA1 Thr408Met mutation in a patient with Parkinson’s disease
Yi ZHAO ; Junwen LI ; Chunlian JU ; Weibin QIU ; Bo ZUO ; Zhigang YANG ; Yansheng LI
Chinese Journal of Clinical Medicine 2025;32(3):524-528
GBA1 gene mutation is an important genetic risk factor for Parkinson’s disease (PD). This paper reports a case of a 43-year-old male PD patient carrying a rare heterozygous Thr408Met mutation in the GBA1 gene identified through whole-exome sequencing, leading to a diagnosis of GBA1-associated PD. The patient’s motor symptoms were primarily characterized by bradykinesia and rigidity, without significant cognitive decline. Treatment with low-dose levodopa combined with a dopamine agonist resulted in significant symptomatic improvement.
5.Efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability complicated by vertebral artery anomalies
Peng ZOU ; Yansheng HUANG ; Xiaojun YU ; Xinliang ZHANG ; Lingjiang LI ; Yiguang HAO ; Ruirui BU ; Liujie XUE ; Xiaodong WANG ; Baorong HE ; Xiaoqiang HUANG ; Yuanting ZHAO
Chinese Journal of Trauma 2025;41(8):740-745
Objective:To evaluate the efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability (AAI) complicated by vertebral artery anomalies.Methods:A retrospective case series study was conducted to analyze the clinical data of 23 patients with AAI complicated by vertebral artery anomalies who were admitted to Honghui Hospital of Xi′an Jiaotong University between January 2019 and January 2023, including 10 males and 13 females, aged 19-70 years [(51.0±13.3)years]. Vertebral artery anomalies were categorized into unilateral high-riding vertebral artery with unilateral dominance ( n=14), bilateral high-riding vertebral arteries with unilateral dominance ( n=6), and ponticulus posticus ( n=3). All the patients underwent preoperative planning using a 3D-printed model of the atlantoaxial complex with the vertebral artery, followed by posterior atlantoaxial pedicle screw fixation with computer-assisted navigation. Operative duration and intraoperative blood loss were recorded. The accuracy of pedicle screw placement was assessed at 3 days postoperatively using the Gertzbein-Robbins classification. Visual analogue scale (VAS) scores and Japanese Orthopedic Association (JOA) scores were evaluated preoperatively, at 3 days, 3 months postoperatively, and at the last follow-up. Bony fusion was assessed using cervical CT with 3D reconstruction at the last follow-up. Complications were also observed. Results:All the patients were followed up for 12-19 months [(15.1±1.9)months]. The operative duration was 125-167 minutes [(140.6±10.9)minutes] and intraoperative blood loss was 200-600 ml [(295.7±77.8)ml]. At 3 days postoperatively, all the 66 pedicle screws were safely placed, with 60 screws (91%) rated as Gertzbein-Robbins Grade 0 and 6 screws (9%) as Grade 1. At 3 days and 3 months postoperatively, and at the last follow-up, the VAS scores were (4.0±1.0)points, (2.0±0.6)points, and (1.3±0.5)points, and the JOA scores were (14.2±1.2)points, (16.0±0.8)points, and (16.6±0.5)points, both of which were not only significantly improved compared with preoperative (5.6±1.3)points and (12.8±1.5)points, but also further improved over time ( P<0.05). At the last follow-up, 22 patients (96%) achieved satisfactory atlantoaxial bony fusion. No vertebral artery injury, spinal cord or nerve injury, cerebrospinal fluid leakage, or screw loosening were observed in any patients. Conclusion:For patients with AAI complicated by vertebral artery anomalies, 3D printing combined with computer navigation-assisted navigation for atlantoaxial pedicle screw implantation offers multiple advantages, including minimal surgical trauma, high screw placement accuracy, pain relief, neurological function improvement, high fusion rate, and lowered incidence of complications.
6.Efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability complicated by vertebral artery anomalies
Peng ZOU ; Yansheng HUANG ; Xiaojun YU ; Xinliang ZHANG ; Lingjiang LI ; Yiguang HAO ; Ruirui BU ; Liujie XUE ; Xiaodong WANG ; Baorong HE ; Xiaoqiang HUANG ; Yuanting ZHAO
Chinese Journal of Trauma 2025;41(8):740-745
Objective:To evaluate the efficacy of 3D printing technology combined with computer navigation-assisted screw implantation in the treatment of atlantoaxial instability (AAI) complicated by vertebral artery anomalies.Methods:A retrospective case series study was conducted to analyze the clinical data of 23 patients with AAI complicated by vertebral artery anomalies who were admitted to Honghui Hospital of Xi′an Jiaotong University between January 2019 and January 2023, including 10 males and 13 females, aged 19-70 years [(51.0±13.3)years]. Vertebral artery anomalies were categorized into unilateral high-riding vertebral artery with unilateral dominance ( n=14), bilateral high-riding vertebral arteries with unilateral dominance ( n=6), and ponticulus posticus ( n=3). All the patients underwent preoperative planning using a 3D-printed model of the atlantoaxial complex with the vertebral artery, followed by posterior atlantoaxial pedicle screw fixation with computer-assisted navigation. Operative duration and intraoperative blood loss were recorded. The accuracy of pedicle screw placement was assessed at 3 days postoperatively using the Gertzbein-Robbins classification. Visual analogue scale (VAS) scores and Japanese Orthopedic Association (JOA) scores were evaluated preoperatively, at 3 days, 3 months postoperatively, and at the last follow-up. Bony fusion was assessed using cervical CT with 3D reconstruction at the last follow-up. Complications were also observed. Results:All the patients were followed up for 12-19 months [(15.1±1.9)months]. The operative duration was 125-167 minutes [(140.6±10.9)minutes] and intraoperative blood loss was 200-600 ml [(295.7±77.8)ml]. At 3 days postoperatively, all the 66 pedicle screws were safely placed, with 60 screws (91%) rated as Gertzbein-Robbins Grade 0 and 6 screws (9%) as Grade 1. At 3 days and 3 months postoperatively, and at the last follow-up, the VAS scores were (4.0±1.0)points, (2.0±0.6)points, and (1.3±0.5)points, and the JOA scores were (14.2±1.2)points, (16.0±0.8)points, and (16.6±0.5)points, both of which were not only significantly improved compared with preoperative (5.6±1.3)points and (12.8±1.5)points, but also further improved over time ( P<0.05). At the last follow-up, 22 patients (96%) achieved satisfactory atlantoaxial bony fusion. No vertebral artery injury, spinal cord or nerve injury, cerebrospinal fluid leakage, or screw loosening were observed in any patients. Conclusion:For patients with AAI complicated by vertebral artery anomalies, 3D printing combined with computer navigation-assisted navigation for atlantoaxial pedicle screw implantation offers multiple advantages, including minimal surgical trauma, high screw placement accuracy, pain relief, neurological function improvement, high fusion rate, and lowered incidence of complications.
7.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
8.Progress in soluble secreted form of hepatitis E virus ORF2 protein
Chinese Journal of Microbiology and Immunology 2025;45(2):149-155
The genome of hepatitis E virus (HEV) contains three open reading frames (ORF1-3), among which ORF2 encodes the viral capsid protein. It has been believed that ORF2 only encodes the structural protein for assembling the capsid of HEV virion. However, recent findings have revealed that during HEV replication, ORF2 also produces a substantial amount of glycosylated soluble protein secreted outside the host cells, known as the ORF2 secreted form (ORF2S). Although not involved in virion assembly, the soluble secreted form of ORF2 protein may play a crucial role in HEV infection and pathogenesis. This review presents an overview of research progress in HEV ORF2S.
9.Advances in animal models of influenza A virus infection
Yifei WANG ; Weijin HUANG ; Yansheng GENG ; Chenyan ZHAO
Chinese Journal of Microbiology and Immunology 2023;43(9):727-732
Influenza has caused high morbidity and mortality worldwide, seriously endangering human health and life. The continuous mutation of influenza virus has brought new challenges to the prevention and treatment of influenza. Animal models provide convenience for a comprehensive understanding of influenza virus pathogenesis, transmission mechanism, vaccine development, and evaluation of therapeutic effects. The construction and use of animal models of influenza virus infection vary in different studies, and the application of different animal models also has its own characteristics. This article reviewed the current status of the construction and use of various animal models, and summarized the advantages and limitations of animal models in evaluating the efficacy of antibodies, drugs and vaccines, with the aim of providing reference for the selection and optimization of animal models in the future.
10. Chemical constituents and pharmacological activities of medicinal plants from Rosa genus
Yansheng WANG ; Xinnan LIU ; Dailin LIU ; Yansheng WANG ; Jingze ZHANG ; Dailin LIU ; Yanmin ZHAO ; Jingyang LI
Chinese Herbal Medicines 2022;14(2):187-209
The genus Rosa (Rosaceae family) includes about 200 species spread in the world, and this genus shows unique advantages in medicine and food. To date, several scholars concentrated on compounds belonging to flavonoids, triterpenes, tannins, polysaccharide, phenolic acids, fatty acids, organic acids, carotenoids, and vitamins. Pharmacological effects such as antineoplastic and anti-cancer properties, anti-inflammatory, antioxidant, liver protection, regulate blood sugar, antimicrobial activity, antiviral activity, as well as nervous system protection and cardiovascular protection were wildly reported. This article reviews the chemical constituents, pharmacological effects, applications and safety evaluations of Rosa plants, which provides a reference for the comprehensive utilization of medicine and food resources and gives a scientific basis for the development of medicinal plants of the genus Rosa.

Result Analysis
Print
Save
E-mail