1.Ex vivo experiment on the safety and efficacy of a new domestic bipolar radiofrequency ablation generator
Yansen HUANG ; Annan HU ; Bing LIANG ; Zizheng WU ; Xiaogang ZHOU
Chinese Journal of Clinical Medicine 2026;33(5):880-886
Objective To evaluate the safety and efficacy of a new domestic ultra-high frequency bipolar radiofrequency ablation device. Methods Six fresh cadaveric lumbar spine specimens were used as experimental subjects, and a novel domestic ultra-high frequency bipolar radiofrequency ablation device was employed for nucleus pulposus ablation and annulus fibrosus cauterization. Nucleus pulposus ablation: a total of 18 intervertebral discs from L1 to L4 were selected and randomly divided into six groups. Radiofrequency electrodes were inserted into the intervertebral discs through the lateral aspect of the intervertebral foramen, and the ablation was performed at power outputs of 50 W, 75 W, and 100 W for 1 min and 2 min, respectively. The ablation of the nucleus pulposus was observed, and the ablation range was recorded. Annulus fibrosus cauterization: a total of 12 intervertebral discs from L4 to S1 were divided into three groups based on cauterization duration of 3 s, 10 s, or 15 s. In a water bath maintained at a constant 37 °C, cauterization was performed at power outputs of 20 W, 30 W, and 40 W, respectively. After hard tissue sectioning and hematoxylin and eosin (HE) staining, the depth of cauterization and the carbonization of surrounding soft tissues were observed. Results No obvious vaporization cavity was observed in the nucleus pulposus at a power of 50 W for either 1 or 2 min. The 100 W–2 min group achieved the largest ablation area ([7.471±0.365] mm2, P<0.001). The temperature elevation at all four annulus fibrosus sites remained below 0.5℃ throughout the ablation process. The cauterization depth in the 20 W group was significantly lower than that in both the 30 W and 40 W groups across all time conditions (P<0.01), whereas no statistically significant difference was observed between the latter two. In 20 W group, the cauterization depth at 3 s was significantly lower than that of the 10 s and 15 s groups (P<0.01). No significant intra-group differences were found among subgroups with different cauterization durations in the 30 W and 40 W groups. An effective cauterization depth was already achieved at 30 W for 3 s. Conclusions Ex vivo experiments have shown that the new domestic bipolar radiofrequency ablation device possesses excellent ablation efficacy and safety parameters. For nucleus pulposus ablation, it is recommended to use 100 W for 2 min, while for annulus fibrosus cauterization and shaping, 30 W for 3 s is suggested. Its clinical application value remains to be further verified through in vivo studies.
2.Autophagy and diabetic wound healing:research progress
Yansen HU ; Chao GUO ; Maoyu WANG ; Xiangfang CHEN
Academic Journal of Naval Medical University 2025;46(3):374-380
During the healing of diabetic wounds,prolonged inflammation,difficulty in angiogenesis,and decreased epithelialization ability of keratinocytes often appear,which lead to delayed wound healing.Autophagy is a catabolic pathway that degrades intracellular proteins,promotes cell survival,and maintains cellular biological functions.Recent studies have shown that autophagy affects the healing of diabetic wounds through various mechanisms.This article reviews the potential mechanism of autophagy in diabetic wound healing:autophagy may delay wound healing by causing a decrease in the phagocytic ability and polarization of macrophages,a decrease in the angiogenesis ability of endothelial progenitor cells,a decrease in the migration ability and proliferation of keratinocytes,and an increase in the apoptosis of fibroblasts,which may provide new ideas for finding therapeutic targets for diabetic wound healing.

Result Analysis
Print
Save
E-mail