1.Exploration on the acceptability of routine biochemical test results for serum samples with varying degrees of chylous high triglyceride
Xi ZHANG ; Qing YANG ; Tao KANG ; Ge LI ; Zhiyang WANG ; Li ZHANG ; Xue WANG ; Pei LI ; Kan ZHONG ; Yanguo TAN
International Journal of Laboratory Medicine 2025;46(7):780-785
Objective To explore the acceptability of routine biochemical test results for serum samples with varying degrees of chylous high triglyceride(TG).Methods Blood samples of 69 patients with different degrees of lipids were collected,including 33 patients with mild to moderate lipids(1.7 mmol/L≤TG<5.6 mmol/L)and 36 patients with severe lipids(TG≥5.6 mmol/L).Twenty-nine biochemical tests were detected before and after high-speed centrifugation.The result acceptability before high speed centrifugation of serum was compared with the results after high speed centrifugation as the gold standard[TG and total cholesterol(TC)before centrifugation].The acceptable criteria were subject to the following three conditions at the same time.Firstly,correlation coefficient(R2)was greater than or equal to 0.95.Secondly,the slope of linear re-gression equation was 1.00±0.05.Thirdly,for the same index,the number of samples whose result bias be-fore and after centrifugation was less than 1/2 total allowable error(TEa)in more than 90%of the total sam-ple numbers.Results Firstly,in the mild to moderate lipemia group,22 tests met the criteria,7 tests did not,including total protein(TP),albumin(ALB),TG,aspartate aminotransferase(AST),carbon dioxide(CO2),α-L-fucosidase(AFU),lactate dehydrogenase(LDH)(bias<10%),and the coincidence rate was 75.9%.In the severe lipemia group,12 tests met the criteria,17 tests did not,including pre-albumin(PA),AFU,γ-glu-tamyltransferase(γ-GT),LDH,AST,TC,direct bilirubin(DBIL),CO2,5'-nucleotidase(5'-NT),small and low-density lipoprotein cholesterol(sd-LDL-C),high density lipoprotein cholesterol(HDL-C),low-density lipoprotein cholesterol(LDL-C),adenosine deaminase(ADA),cystatin C(CysC),glycosylated albumin(GA),total bilirubin(TBIL)(bias>10%),the coincidence rate was 41.4%,and there was a statistically sig-nificant difference in the coincidence rate between the two groups(P<0.05).Secondly,there was no statisti-cally significant difference in the acceptability of results between continuous monitoring method and endpoint method detection methods(P>0.05).Conclusion Most test results of direct determination with mild or moderate lipemia samples are acceptable,and the bias of unacceptable tests is small(<10%),so it is recom-mended to issue a test report without further sample treatment.However,due to the large number of unacceptable tests and larger bias(>10%),severe lipemia samples should be determined after high-speed centrifugation.
2. Effect of CKIP-1 siRNA lentivirus transfection on proliferation of glioma U87-MG cells
Shixiang CHENG ; Qian ZHANG ; Tailong YI ; Lei ZHU ; Haoxiang XU ; Yanguo XI ; Wenbin ZHANG
Chinese Journal of Behavioral Medicine and Brain Science 2018;27(7):588-592
Objective:
To investigate the effects of Casein kinase 2-interacting protein 1 (CKIP-1) gene silencing on the proliferation of glioma cells U87-MG.
Methods:
The recombinant lentiviral vectors targeting CKIP-1 gene or negative control were constructed and then used to infect glioma U87-MG cell line.The effects of knock-down on the mRNA or protein expression of CKIP-1 were evaluated by real-time qPCR and western blotting.Cell cycle was detected by the flow cytometry assay, and cell proliferation changes were evaluated by cell counting, MTT, and BrdU assay, respectively.Lastly, the colony formation was used to investigate the effect of CKIP-1 knock-down on the clone formation.
Results:
Compared with the group of Ctrl, CKIP-1 siRNA was observed to significantly inhibit CKIP-1 expression at the mRNA levels (Ctrl (1.01±0.13)

Result Analysis
Print
Save
E-mail