1.Study on the Effects of Microvascular Anastomosis on Tissue in Rat Peripheral Artery Model
Qi Yanbo ; Sanchin U ; Anar B ; Galindev B ; Baatarsuren B
Mongolian Journal of Health Sciences 2025;85(1):148-154
Background:
Peripheral artery occlusion is the final stage of complications in peripheral arterial disease, which has a
serious negative impact on the quality of life of patients. A study conducted in Germany found that 66% of the over 40,000
patients diagnosed with peripheral artery occlusion required limb amputation within four years of diagnosis. The primary
treatment goals are to improve limb blood flow, alleviate pain, accelerate tissue regeneration, and prevent cardiovascular
complications. Recent studies emphasize that microsurgical techniques may accelerate tissue regeneration and improve
treatment outcomes.
Aim:
This study aimed to evaluate and compare the effects of end-to-end (ETE) and end-to-side (ETS) microvascular
anastomosis in a rat model of ischemia, focusing on tissue regeneration.
Materials and Methods:
Thirty Wistar rats were divided into two groups (control group 10 rats, ischemic group 20 rats)
at the Bio-Medical Research Institute of the Mongolian National University of Medical Sciences. Ischemia was induced
in the experimental group, and ETE and ETS anastomoses were performed using donor arteries, which were preserved for
three days. Preoperative and 21-day postoperative body weight, artery size, and blood flow were measured and analyzed
to determine the results.
Results:
In the control group, the average body weight was 227.86±21.11 grams before surgery, which increased by 12.38
grams to 240.24±25.77 grams post-surgery (p<0.01). In the ischemic group, the rats that underwent ETE anastomosis had
an average weight of 239.67±26.96 grams before surgery, which decreased to 234.3±27.20 grams immediately after surgery, but increased to 250.67±27.09 grams after 21 days (p<0.05). The ETS group showed an increase from 235.18±22.39
grams to 249.62±21.12 grams after 21 days (p<0.01). The surgical duration for the control group was 24.51±2.29 minutes,
while the ischemic group required 39.75±0.89 minutes for ETE and 46.65±8.12 minutes for ETS anastomoses (p=0.001).
Intraoperative blood loss in the control group was 0.27±0.12 ml, whereas the ischemic group showed blood loss of
0.58±0.13 ml for ETE and 1.12±0.61 ml for ETS, with some instances reaching 2.35 ml (p<0.01).
Conclusions
1. The body weight of the control rats increased to 240.24±25.77 grams after 21 days, while the ischemic group showed
an increase to 250.67±27.09 grams, indicating improved tissue regeneration and successful microsurgical anastomosis.
2. Although PCNA and KGF protein expression levels decreased, tissue regeneration was robust, as evidenced by the
continued regeneration observed 21 days after the microsurgery, indicating successful microvascular surgery. Differences in the response to ischemic changes were observed across tissues, with increased expression of KGF and
PCNA in the skin and muscle tissues, further supporting the effectiveness of the regenerative process.
2.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
3.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
4.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
5.Study of prediction of hemorrhagic fever with renal syndrome incidence in Hebei Province based on generalized additive model
Zhonghang YUE ; Xu HAN ; Yamei WEI ; Yanan CAI ; Zhanying HAN ; Yanbo ZHANG ; Yonggang XU ; Qi LI
Chinese Journal of Epidemiology 2025;46(3):418-422
Objective:To predict the monthly incidence of hemorrhagic fever with renal syndrome (HFRS) in Hebei Province by using the generalized additive model (GAM).Methods:The incidence data of HFRS in Hebei from 2006 to 2020 were collected, and the correlation coefficients between meteorological factors and the monthly incidence of HFRS in Hebei were analyzed by Spearman's correlation, and the meteorological factors were lagged by 0-6 orders, and those with the largest absolute values of the correlation coefficients were screened to be included in the multifactorial GAM to evaluate the effects of meteorological factors.Results:The monthly incidence of HFRS had the strongest correlation with monthly mean air temperature at lag order 2, monthly mean wind speed at lag order 0, monthly mean sunshine at lag order 4, monthly mean precipitation at lag order 2 and monthly mean humidity at lag order 1, which were diagnosed by the variance inflation factor and included in the multifactorial GAM, and the results showed significant differences among the factors (all P<0.001), and they showed non-linear relationships with the monthly incidence of HFRS. Mean monthly temperature was an important factor influencing HFRS incidence. Mean monthly air temperature, mean monthly sunshine and mean monthly wind speed were negatively associated with HFRS incidence, whereas mean monthly precipitation and mean monthly humidity were positively associated with HFRS incidence. Conclusions:There was a complex non-linear relationship between meteorological factors and the incidence of HFRS. GAM incorporated with lagged meteorological factors can be used to predict the incidence of HFRS in Hebei.
6.A qualitative study on the training needs of general practitioners in community health centers for health care of older patients
Xinxin ZHAO ; Hao WANG ; Hua JIANG ; Yanbo WANG ; Zhijuan QI ; Jialin ZHENG
Chinese Journal of General Practitioners 2025;24(7):817-822
Objective:To investigate the training needs of general practitioners in community health center in health care and management of older patients for developing a curriculum for the Extension for Community Health Outcomes (ECHO) project accordingly.Methods:This was a qualitative study. The semi-structured interviews were conducted with 20 community health center general practitioners (GPs) using focus groups between March 2024 and April 2024. The interview data were collated using Nvivo12 software and coded using thematic analysis. The focus of the interviews was on the challenges GPs face in health care of older people in the community and relevant training needs.Results:Three male and 17 female GPs took part in the interviews. The interviews showed that GPs in comminity health service centers faced multiple challenges in the helth management of older patients, including implementation of holistic treatment plans, time-consuming comprehensive patient assessment, lack of standardized medication selection, unclear referral processes and difficulties in establishing a trusting doctor-patient relationship. The study suggested that the design and development of training programs should encompass eight core components: differentiated end-of-life care for patients, nutritional advice, positive psychological intervention, software data-based health assessment, systematic geriatric medicine, updated clinical research findings, medication selection and treatment guidelines, and insulin resistance management.Conclusion:Through qualitative investigation, this study explored the challenges faced by general practitioners in providing health care for older patients and relevant training needs, which provids evidence for designing and developing corresponding curricula for ECHO projects.
7.Application status and development prospect of digital intelligence technology in the diagnosis and treatment of rare diseases
Yujie YANG ; Leyuan QI ; Yanbo CAO ; Xiaotian WEN ; Jicong LIU ; Bixiao CHEN ; Yawei LIU ; Guohua HE ; Yu TIAN
Chinese Journal of Pharmacoepidemiology 2025;34(8):972-985
Rare diseases pose significant diagnostic and therapeutic challenges,carrying a high disease burden,their management critically reflects a nation's public health resilience.Currently,China faces key challenges such as scarce treatments,fragmented services,and low drug accessibility in rare disease care,which urgently require systemic solutions.Digital-intelligent technology as a key breakthrough are expected to resolve the challenges in this field.Although its application in the field of rare diseases is gradually expanding,there is a lack of systematic compilation of studies to elucidate how to precisely enhance the precision,synergy and sustainability of diagnosis and treatment.The key challenges in rare disease care concentrate in four areas:inefficiency in prenatal screening,uneven distribution of medical resources,low efficiency in social organization collaboration,and ineffective information dissemination.The"4C"strategy,based on digital-intelligent technology,can address these issues:①coordination,boost prenatal screening awareness and capacity via digital-intelligent platforms to strengthen prevention;②cooperation,deepen collaboration within specialist networks,empowering institutions to enhance diagnostic capacity;③co-creation,empower support organizations to optimize resources,efficiency;④cognition,minimize information dissipation through efficient platforms,improving patient and family quality of life.This establishes an integrated digital-intelligent rare disease model encompassing"screening-diagnosis-treatment-care".
8.Role of CDH1 gene DNA methylation in autoimmune thyroiditis in population from different water-iodine regions
Baiming JIN ; Yanbo QI ; Fengge LOU ; Hong CHAO ; Xiaolei YANG ; Hongjie LI ; Zheng ZHOU ; Yao CHEN ; Hongmei SHEN ; Siyuan WAN
Chinese Journal of Endemiology 2025;44(6):431-438
Objective:To study the role of cadherin 1 (CDH1) gene DNA methylation in autoimmune thyroiditis (AIT) in population from different water-iodine regions.Methods:From May to June 2019, the information of AIT cases and healthy individuals in Shandong Province were collected in three types of water-iodine regions: iodine-fortification (IF) region, iodine-adequate (IA) region and iodine-excess (IE) region. A case-control study design was applied to match 176 AIT cases (case group) with age, gender, body mass index, and place of residence in a 1 ∶ 1 ratio to 176 healthy individuals (control group). Fasting urine and whole blood samples were collected to test the contents of urinary iodine, thyroid function indicators [serum free triiodothyronine (FT 3), free thyroxine (FT 4), thyroid stimulating hormone (TSH)], and serum iodine. The DNA methylation levels of the target region of the CDH1 gene and its four CpG sites in whole blood were determined using methylation sequencing technology for target regions (MethylTarget TM). Results:The DNA methylation level of the target region of CDH1 gene in the case group was 0.832 ± 0.044, and that in the control group was 0.828 ± 0.049, there was no statistically significant difference between the two groups ( t = 0.76, P = 0.448). There was no statistically significant difference in DNA methylation levels of the four CpG sites in the target region of CDH1 gene between the case group and the control group ( P > 0.05). There was no statistically significant difference in the DNA methylation level of the CDH1 gene target region between the case group and the control group in IF, IA and IE regions ( P > 0.05). The detection results of DNA methylation levels at CpG sites in the target region of CDH1 gene in different water iodine regions showed that the DNA methylation level at site 83 in case group in IF region was higher than that in the control group ( t = 2.30, P = 0.023). However, there was no statistically significant difference in the DNA methylation levels of the four CpG sites between the case group and the control group in IA and IE regions ( P > 0.05). The DNA methylation level of CDH1 gene target region in AIT patients was not significantly correlated with urinary iodine, serum iodine, and serum FT 3, FT 4, and TSH contents ( P > 0.05), but was significantly negatively correlated with age ( r =-0.19, P = 0.014). Conclusions:The DNA methylation level at CpG site 83 of CDH1 gene in AIT patients in IF region is significantly higher than that in control population, indicating that DNA methylation at this locus may be involved in the occurrence and development of AIT after iodine fortification. The DNA methylation level of CDH1 gene is negatively correlated with age.
9.Study of prediction of hemorrhagic fever with renal syndrome incidence in Hebei Province based on generalized additive model
Zhonghang YUE ; Xu HAN ; Yamei WEI ; Yanan CAI ; Zhanying HAN ; Yanbo ZHANG ; Yonggang XU ; Qi LI
Chinese Journal of Epidemiology 2025;46(3):418-422
Objective:To predict the monthly incidence of hemorrhagic fever with renal syndrome (HFRS) in Hebei Province by using the generalized additive model (GAM).Methods:The incidence data of HFRS in Hebei from 2006 to 2020 were collected, and the correlation coefficients between meteorological factors and the monthly incidence of HFRS in Hebei were analyzed by Spearman's correlation, and the meteorological factors were lagged by 0-6 orders, and those with the largest absolute values of the correlation coefficients were screened to be included in the multifactorial GAM to evaluate the effects of meteorological factors.Results:The monthly incidence of HFRS had the strongest correlation with monthly mean air temperature at lag order 2, monthly mean wind speed at lag order 0, monthly mean sunshine at lag order 4, monthly mean precipitation at lag order 2 and monthly mean humidity at lag order 1, which were diagnosed by the variance inflation factor and included in the multifactorial GAM, and the results showed significant differences among the factors (all P<0.001), and they showed non-linear relationships with the monthly incidence of HFRS. Mean monthly temperature was an important factor influencing HFRS incidence. Mean monthly air temperature, mean monthly sunshine and mean monthly wind speed were negatively associated with HFRS incidence, whereas mean monthly precipitation and mean monthly humidity were positively associated with HFRS incidence. Conclusions:There was a complex non-linear relationship between meteorological factors and the incidence of HFRS. GAM incorporated with lagged meteorological factors can be used to predict the incidence of HFRS in Hebei.
10.Application status and development prospect of digital intelligence technology in the diagnosis and treatment of rare diseases
Yujie YANG ; Leyuan QI ; Yanbo CAO ; Xiaotian WEN ; Jicong LIU ; Bixiao CHEN ; Yawei LIU ; Guohua HE ; Yu TIAN
Chinese Journal of Pharmacoepidemiology 2025;34(8):972-985
Rare diseases pose significant diagnostic and therapeutic challenges,carrying a high disease burden,their management critically reflects a nation's public health resilience.Currently,China faces key challenges such as scarce treatments,fragmented services,and low drug accessibility in rare disease care,which urgently require systemic solutions.Digital-intelligent technology as a key breakthrough are expected to resolve the challenges in this field.Although its application in the field of rare diseases is gradually expanding,there is a lack of systematic compilation of studies to elucidate how to precisely enhance the precision,synergy and sustainability of diagnosis and treatment.The key challenges in rare disease care concentrate in four areas:inefficiency in prenatal screening,uneven distribution of medical resources,low efficiency in social organization collaboration,and ineffective information dissemination.The"4C"strategy,based on digital-intelligent technology,can address these issues:①coordination,boost prenatal screening awareness and capacity via digital-intelligent platforms to strengthen prevention;②cooperation,deepen collaboration within specialist networks,empowering institutions to enhance diagnostic capacity;③co-creation,empower support organizations to optimize resources,efficiency;④cognition,minimize information dissipation through efficient platforms,improving patient and family quality of life.This establishes an integrated digital-intelligent rare disease model encompassing"screening-diagnosis-treatment-care".

Result Analysis
Print
Save
E-mail