1.Downregulated vascular endothelial growth factor A as a biomarker of immunosenescence in benign prostatic hyperplasia
Junduo WANG ; Jun ZHU ; Yanbo CHEN ; Meng GU ; Jiatai HE ; Bin XU ; Qi CHEN
Journal of Modern Urology 2026;31(1):67-77
Objective To identify potential immunosenescence markers in benign prostatic hyperplasia(BPH)and to explore BPH-related senescent phenotypes. Methods Three transcriptome datasets and one single-cell RNA-sequencing(scRNA-seq)dataset for BPH and normal prostate tissues were obtained from the Gene Expression Omnibus(GEO)database. The GSE7307 and GSE119195 were combined to analyze differentially expressed genes(DEGs). Enrichment analysis and immune infiltration analysis were used to explore aging-related changes in the immune microenvironment. Weighted gene coexpression network analysis(WGCNA)was applied to identify immune-related genes in GSE132714. ScRNA-seq data were employed to investigate the transcriptomic landscape, luminal cell heterogeneity, and aging-related alterations in BPH through cell-cell communication and pseudotime analysis. Finally, the results were validated with in vitro experiments. Results A total of 1202 DEGs and 627 immune-related genes were identified in BPH and normal prostate tissues. Enrichment analysis indicated that the vascular endothelial growth factor(VEGF)signaling pathway exhibited a downregulated aging phenotype in BPH. In scRNA-seq analysis, 9 cell types were identified. The VEGF signaling pathway in BPH exhibited an aging-related expression pattern, characterized by decreased vascular endothelial growth factor A(VEGFA)in luminal cells. Conclusion Our study identified VEGFA as a marker of immunosenescence in BPH, with changes of the VEGF pathway. Meanwhile, low expression of VEGFA, coupled with high expression of placental growth factor(PlGF)and vascular endothelial growth factor receptor(VEGFR), represented a senescent phenotype of the prostate.
2.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
3.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
4.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
5.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
6.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
7.Mechanism of Modified Huanglian Wendan Decoction in Regulating Autophagy to Improve Insulin Resistance HepG2 Cells Based on JAK2/STAT3 Signaling Pathway
Xing YANG ; Chenghong ZHENG ; Yanbo FAN ; Nian DING ; Mengyu GU ; Yaming DU ; Xiuqi ZOU ; Xinbang LIU
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(8):114-121
Objective To investigate the mechanism of modified Huanglian Wendan Decoction in improving insulin resistance(IR)HepG2 cells by regulating JAK2/STAT3 signaling pathway.Methods HepG2 cells were incubated with 0.25 mmol/L palmitic acid for 24 h to induce IR model.The cells were divided into model group,drug containing serum group and metformin hydrochloride group.Blank serum,modified Huanglian Wendan Decoction drug containing serum and 2 mmol/L metformin hydrochloride intervention were administered,respectively.Normal cultured HepG2 cells were used as control group.The glucose assay kit was used to detect the glucose content in the cell supernatant,the liver glycogen assay kit was used to detect the glycogen content in the cells,the triglycerides(TG)assay kit was used to detect the TG content in the cells,PAS staining was used to observe the glycogen status of the cells,oil red O staining was used to observe the lipid droplet status of the cells,ELISA assay kit was used to detect the contents of interleukin-6(IL-6)and tumor necrosis factor(TNF)-α in cell supernatant,Western blot was used to detect the protein expressions of Janus kinase 2(JAK2),signal transduction and transcription activator 3(STAT3),LC3 and Beclin-1 in the cells.Results Compared with the control group,the glucose content in the supernatant of HepG2 cells in the model group increased(P<0.01),the intracellular glycogen content decreased(P<0.01),the TG content increased(P<0.01),the glycogen staining area decreased(P<0.01),the lipid droplet staining area increased(P<0.01),the contents of IL-6 and TNF-α in the supernatant increased(P<0.01),the expressions of JAK2 and STAT3 proteins increased(P<0.01),and the protein expression of LC3Ⅱ/LC3Ⅰ and Beclin-1 decreased(P<0.01).Compared with the model group,the glucose content decreased in the drug containing serum group and metformin hydrochloride group(P<0.01),the intracellular glycogen content increased(P<0.01),the TG content decreased(P<0.01),the glycogen staining area increased(P<0.01),the lipid droplet staining area decreased(P<0.01),the contents of IL-6 and TNF-α in cell supernatant decreased(P<0.01),the expressions of JAK2 and STAT3 proteins decreased(P<0.01),and the expressions of LC3Ⅱ/LC3Ⅰ and Beclin-1 proteins increased(P<0.05,P<0.01).The effect of modified Huanglian Wendan Decoction was better than that of metformin hydrochloride(P<0.05,P<0.01).Conclusion Modified Huanglian Wendan Decoction can possibly improve glucose and lipid metabolism and reduce inflammation in IR-HepG2 cells through intervening JAK2/STAT3 signaling pathway and mediating autophagy.
8.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
9.Mechanism of Modified Huanglian Wendan Decoction in Regulating Autophagy to Improve Insulin Resistance HepG2 Cells Based on JAK2/STAT3 Signaling Pathway
Xing YANG ; Chenghong ZHENG ; Yanbo FAN ; Nian DING ; Mengyu GU ; Yaming DU ; Xiuqi ZOU ; Xinbang LIU
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(8):114-121
Objective To investigate the mechanism of modified Huanglian Wendan Decoction in improving insulin resistance(IR)HepG2 cells by regulating JAK2/STAT3 signaling pathway.Methods HepG2 cells were incubated with 0.25 mmol/L palmitic acid for 24 h to induce IR model.The cells were divided into model group,drug containing serum group and metformin hydrochloride group.Blank serum,modified Huanglian Wendan Decoction drug containing serum and 2 mmol/L metformin hydrochloride intervention were administered,respectively.Normal cultured HepG2 cells were used as control group.The glucose assay kit was used to detect the glucose content in the cell supernatant,the liver glycogen assay kit was used to detect the glycogen content in the cells,the triglycerides(TG)assay kit was used to detect the TG content in the cells,PAS staining was used to observe the glycogen status of the cells,oil red O staining was used to observe the lipid droplet status of the cells,ELISA assay kit was used to detect the contents of interleukin-6(IL-6)and tumor necrosis factor(TNF)-α in cell supernatant,Western blot was used to detect the protein expressions of Janus kinase 2(JAK2),signal transduction and transcription activator 3(STAT3),LC3 and Beclin-1 in the cells.Results Compared with the control group,the glucose content in the supernatant of HepG2 cells in the model group increased(P<0.01),the intracellular glycogen content decreased(P<0.01),the TG content increased(P<0.01),the glycogen staining area decreased(P<0.01),the lipid droplet staining area increased(P<0.01),the contents of IL-6 and TNF-α in the supernatant increased(P<0.01),the expressions of JAK2 and STAT3 proteins increased(P<0.01),and the protein expression of LC3Ⅱ/LC3Ⅰ and Beclin-1 decreased(P<0.01).Compared with the model group,the glucose content decreased in the drug containing serum group and metformin hydrochloride group(P<0.01),the intracellular glycogen content increased(P<0.01),the TG content decreased(P<0.01),the glycogen staining area increased(P<0.01),the lipid droplet staining area decreased(P<0.01),the contents of IL-6 and TNF-α in cell supernatant decreased(P<0.01),the expressions of JAK2 and STAT3 proteins decreased(P<0.01),and the expressions of LC3Ⅱ/LC3Ⅰ and Beclin-1 proteins increased(P<0.05,P<0.01).The effect of modified Huanglian Wendan Decoction was better than that of metformin hydrochloride(P<0.05,P<0.01).Conclusion Modified Huanglian Wendan Decoction can possibly improve glucose and lipid metabolism and reduce inflammation in IR-HepG2 cells through intervening JAK2/STAT3 signaling pathway and mediating autophagy.
10.Impact of early percutaneous coronary intervention after thrombolysis on myocardial perfusion and left ventricular function in patients with acute ST-segment elevation myocardial infarction
Yajing MIAO ; Xiaoxu WANG ; Yanbo WANG ; Gaojie HAN ; Qiaoli TONG ; Xuqian ZHANG ; Jinglan WU ; Xinshun GU ; Hongning YIN
Chinese Journal of Ultrasonography 2024;33(2):98-105
Objective:To investigate the effects of early percutaneous coronary intervention (PCI) on myocardial perfusion and left ventricular function in patients with acute ST-segment elevation myocardial infarction (STEMI) after thrombolysis.Methods:A total of 108 patients with STEMI treated in the Second Hospital of Hebei Medical University from January 2020 to December 2022 were divided into early PCI following thrombolysis group ( n=65) and primary PCI (pPCI) group ( n=43). The general clinical data, and the parameters of routine echocardiography at 1 day after PCI and before discharge were compared between the two groups. Myocardial contrast echocardiography (MCE) was used to evaluate myocardial perfusion at 1 day after PCI and before discharge. Results:There were no significant differences in general clinical data between the early PCI following thrombolysis group and the pPCI group (all P>0.05). The left ventricular ejection fraction (LVEF) in the early PCI following thrombolysis group and pPCI group before discharge was significantly higher than that on the 1st day after PCI(both P<0.05). The difference of LVEF was significant between the early PCI following thrombolysis group and the pPCI group before discharge and 1 day after PCI ( P<0.05). Compared with 1 day after PCI, the global longitudinal strain (LVGLS) of left ventricle increased in early PCI following thrombolysis group and pPCI group before discharge(both P<0.05). The difference of LVGLS between early PCI following thrombolysis group and pPCI group before discharge and 1 day after discharge was statistically significant( P<0.05). There were no significant differences in left ventricular end-diastolic diameter (LVEDD), left ventricular end-diastolic volume (LVEDV), left atrial volume (LAV), ratio of mitral early diastolic velocity to late diastolic velocity (E/A), mean early diastolic velocity of mitral annulus (Em) and E/Em 1 day after PCI and before discharge between early PCI following thrombolysis group and pPCI group (all P>0.05). MCE showed that the MCE score index of early PCI following thrombolysis group and pPCI group before discharge was significantly lower than that of 1 day after PCI(both P<0.001). Compared to the 1 day after PCI, the early PCI following thrombolysis group showed a significant increase in the proportion of normal microvascular perfusion (nMVP) and a decrease in the proportion of delayed microvascular perfusion (dMVP) and microvascular obstruction (MVO) before discharge (all P<0.05). In contrast, the pPCI group demonstrated a significant decrease in the proportion of both nMVP and dMVP before discharge compared to the first day after PCI (all P<0.05). However, the decrease in the proportion of MVO was not statistically significant ( P>0.05). Conclusions:Early PCI following thrombolysis and pPCI can enhance left ventricular systolic function and myocardial perfusion in patients with acute ST-elevation myocardial infarction. Early PCI following thrombolysis may offer additional advantages in improving left ventricular systolic function and myocardial perfusion.

Result Analysis
Print
Save
E-mail