1.Influence of pterygium thickness and area on corneal refractive status
Xiaodong CHENG ; Jie WANG ; Song GAO ; Yanhong LU ; Yanbo MA ; Xinming CUI ; Xihui CHEN
International Eye Science 2026;26(1):152-156
AIM: To investigate the influence of pterygium thickness and area on corneal refractive status.METHODS: Prospective longitudinal study. A total of 60 cases(60 eyes)of pterygium patients admitted to our hospital from January 2024 to September 2024 were randomly selected. All patients underwent pterygium excision combined with pedicle conjunctival flap transplantation for treatment. Optical coherence tomography(OCT)was used to measure the preoperative thickness of patient's pterygium, and a digital slit lamp microscope was used to measure the area of pterygium. The corneal refractive status(degree of corneal astigmatism and average curvature)and changes in uncorrected visual acuity of patients before surgery, 1 d, 1, and 3 mo after surgery were compared. The relationship between preoperative thickness and area of pterygium in patients and corneal refractive status indicators at different postoperative time points were analyzed, and Logistic regression was used to analyze the impact of pterygium thickness and area on postoperative visual improvement in patients.RESULTS: All patients completed follow-up after surgery for 3 mo. At 3 mo after surgery, visual acuity improved in 21 eyes(35%). The results of bivariate Pearson correlation analysis showed that the thickness and area of pterygium positively correlated with the degree of corneal astigmatism and uncorrected visual acuity before surgery and 1 d, 1, and 3 mo after surgery(all P<0.05), and negatively correlated with the average corneal curvature before surgery and 1 d, 1, and 3 mo after surgery(all P<0.05). Logistic regression analysis showed that the thickness and area of pterygium before surgery, high degree of corneal astigmatism, and low uncorrected visual acuity(large LogMAR value)were all risk factors for poor postoperative visual improvement in patients(OR>1, P<0.05). The large average corneal curvature before surgery was a protective factor for poor postoperative visual improvement in patients(OR<1, P<0.05).CONCLUSION: The increase in thickness and area of pterygium can, to some extent, improve corneal astigmatism, reduce the average curvature of the cornea, and affect postoperative visual recovery.
2.New advances in the targeted therapy of EGFR exon20ins mutant advanced NSCLC
Chun YUAN ; Xuesong YU ; Mengchao WANG ; Shao ZHANG ; Yanbo HUANG ; Chaoran WANG ; Fanming KONG ; Liwei CHEN
Journal of International Oncology 2025;52(6):382-387
The epidermal growth factor receptor (EGFR) exon 20 insertion (ex20ins) mutation is a rare subtype of mutations in non-small cell lung cancer (NSCLC). Patients with advanced NSCLC carrying the EGFR ex20ins mutation tend to have poor responses to traditional EGFR tyrosine kinase inhibitors (TKIs), chemotherapy, and immunotherapy, leading to a poor clinical prognosis. Significant progress has been made in the development of new drugs targeting the EGFR ex20ins mutation. The research on new drugs targeting EGFR ex20ins mutations has made significant progress. The main ones include new EGFR-TKIs (such as sunvozertinib, mobocertinib, and furmetinib, etc.), bispecific antibodies (such as amivantamab, JMT101, and GB263T, etc.), and emerging drugs such as AUY922. These agents have demonstrated promising efficacy in clinical trials, improving the objective response rate and progression-free survival of patients, and are expected to improve overall survival. An in-depth analysis of the mechanism of action and clinical trial progress of these novel targeted drugs for EGFR ex20ins-mutated NSCLC can offer new therapeutic strategies for patients with EGFR ex20ins-mutated NSCLC.
3.Application status and development prospect of digital intelligence technology in the diagnosis and treatment of rare diseases
Yujie YANG ; Leyuan QI ; Yanbo CAO ; Xiaotian WEN ; Jicong LIU ; Bixiao CHEN ; Yawei LIU ; Guohua HE ; Yu TIAN
Chinese Journal of Pharmacoepidemiology 2025;34(8):972-985
Rare diseases pose significant diagnostic and therapeutic challenges,carrying a high disease burden,their management critically reflects a nation's public health resilience.Currently,China faces key challenges such as scarce treatments,fragmented services,and low drug accessibility in rare disease care,which urgently require systemic solutions.Digital-intelligent technology as a key breakthrough are expected to resolve the challenges in this field.Although its application in the field of rare diseases is gradually expanding,there is a lack of systematic compilation of studies to elucidate how to precisely enhance the precision,synergy and sustainability of diagnosis and treatment.The key challenges in rare disease care concentrate in four areas:inefficiency in prenatal screening,uneven distribution of medical resources,low efficiency in social organization collaboration,and ineffective information dissemination.The"4C"strategy,based on digital-intelligent technology,can address these issues:①coordination,boost prenatal screening awareness and capacity via digital-intelligent platforms to strengthen prevention;②cooperation,deepen collaboration within specialist networks,empowering institutions to enhance diagnostic capacity;③co-creation,empower support organizations to optimize resources,efficiency;④cognition,minimize information dissipation through efficient platforms,improving patient and family quality of life.This establishes an integrated digital-intelligent rare disease model encompassing"screening-diagnosis-treatment-care".
4.A scoping review of the longitudinal studies on post stroke fatigue
Weiqing FENG ; Yanbo CHEN ; Huan CAI ; Jiahui RUAN ; Xiuxian HE ; Kun LI
Chinese Journal of Nursing 2025;60(7):799-805
Objective To identify the measurement time,assessment tools,changing trends,factors in longitudinal studies on post stroke fatigue.Methods Web of Science,PubMed,CINAHL,Embase,CNKI,CBM,Wanfang,and VIP database were retrieved from inception until December 15,2024.Results A total of 41 papers were included.The measurement time points used with high frequency were 3,6,and 12 months after stroke.10 assessment tools were retrieved and the fatigue severity scale was most selected.The majority of the studies supported that the incidence of post stroke fatigue showed a decreasing trend within 6 months after stroke,an increasing trend from 6 to 12 months,and a decreasing or steady decreasing trend from 12 months.Post stroke fatigue is influenced by demographic,disease,physiologic,psychological,and coping factors.Conclusion The longitudinal studies on post stroke fatigue focused less than 1 year after stroke,but the recovery period is understudied and specific assessment tools need to be further explored.The trend of post stroke fatigue varies at different stages and exists heterogeneity.Future studies should be optimized to explore influence factors.
5.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
6.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
7.Role of CDH1 gene DNA methylation in autoimmune thyroiditis in population from different water-iodine regions
Baiming JIN ; Yanbo QI ; Fengge LOU ; Hong CHAO ; Xiaolei YANG ; Hongjie LI ; Zheng ZHOU ; Yao CHEN ; Hongmei SHEN ; Siyuan WAN
Chinese Journal of Endemiology 2025;44(6):431-438
Objective:To study the role of cadherin 1 (CDH1) gene DNA methylation in autoimmune thyroiditis (AIT) in population from different water-iodine regions.Methods:From May to June 2019, the information of AIT cases and healthy individuals in Shandong Province were collected in three types of water-iodine regions: iodine-fortification (IF) region, iodine-adequate (IA) region and iodine-excess (IE) region. A case-control study design was applied to match 176 AIT cases (case group) with age, gender, body mass index, and place of residence in a 1 ∶ 1 ratio to 176 healthy individuals (control group). Fasting urine and whole blood samples were collected to test the contents of urinary iodine, thyroid function indicators [serum free triiodothyronine (FT 3), free thyroxine (FT 4), thyroid stimulating hormone (TSH)], and serum iodine. The DNA methylation levels of the target region of the CDH1 gene and its four CpG sites in whole blood were determined using methylation sequencing technology for target regions (MethylTarget TM). Results:The DNA methylation level of the target region of CDH1 gene in the case group was 0.832 ± 0.044, and that in the control group was 0.828 ± 0.049, there was no statistically significant difference between the two groups ( t = 0.76, P = 0.448). There was no statistically significant difference in DNA methylation levels of the four CpG sites in the target region of CDH1 gene between the case group and the control group ( P > 0.05). There was no statistically significant difference in the DNA methylation level of the CDH1 gene target region between the case group and the control group in IF, IA and IE regions ( P > 0.05). The detection results of DNA methylation levels at CpG sites in the target region of CDH1 gene in different water iodine regions showed that the DNA methylation level at site 83 in case group in IF region was higher than that in the control group ( t = 2.30, P = 0.023). However, there was no statistically significant difference in the DNA methylation levels of the four CpG sites between the case group and the control group in IA and IE regions ( P > 0.05). The DNA methylation level of CDH1 gene target region in AIT patients was not significantly correlated with urinary iodine, serum iodine, and serum FT 3, FT 4, and TSH contents ( P > 0.05), but was significantly negatively correlated with age ( r =-0.19, P = 0.014). Conclusions:The DNA methylation level at CpG site 83 of CDH1 gene in AIT patients in IF region is significantly higher than that in control population, indicating that DNA methylation at this locus may be involved in the occurrence and development of AIT after iodine fortification. The DNA methylation level of CDH1 gene is negatively correlated with age.
8.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
9.Association between insulin resistance surrogate indicators and early-stage kidney injury in type 2 diabetes
Xinyan ZHANG ; Lina CHEN ; Yanbo LI ; Hui RAN ; Qing SU ; Hongmei ZHANG
Chinese Journal of Endocrinology and Metabolism 2025;41(1):40-45
Objective:To investigate the correlation between insulin resistance surrogate indicators and early-stage kidney injury in type 2 diabetes mellitus(T2DM).Methods:A total of 918 T2DM patients hospitalized in the Endocrinology Department of Xinhua Hospital from January 2018 to December 2020 were selected, including 313 patients with early-stage kidney injury and 605 without. Differences in insulin resistance surrogate indicators, including triglyceride to high-density lipoprotein cholesterol ratio(TG/HDL-C), triglyceride glucose(TyG) index, and triglyceride glucose-body mass index(TyG-BMI), were compared between the two groups. Factors associated with early-stage kidney injury in T2DM were analyzed, and the impact of TG/HDL-C, TyG index, and TyG-BMI on early-stage kidney injury in T2DM were explored.Results:Compared with T2DM patients without early-stage kidney injury, those with early-stage kidney injury exhibited significantly elevated levels of TG/HDL-C, TyG index, and TyG-BMI( P< 0.001). TG/HDL-C, TyG index, TyG-BMI, age, duration of diabetes, systolic blood pressure, fasting insulin, and HbA 1C were identified as independent risk factors for early-stage kidney injury in T2DM. Compared to the Q1 quartile, the risk in the Q4 quartile was 3.168 times(95% CI 1.993-5.036) for TG/HDL-C, 2.714 times(95% CI 1.710-4.306) for TyG index, and 2.893 times(95% CI 1.820-5.598) for TyG-BMI. Conclusion:Insulin resistance surrogate indicators TG/HDL-C, TyG index, and TyG-BMI are significantly elevated in T2DM patients with early-stage kidney injury, serving as independent risk factors for early-stage renal impairment in T2DM.
10.A scoping review of the longitudinal studies on post stroke fatigue
Weiqing FENG ; Yanbo CHEN ; Huan CAI ; Jiahui RUAN ; Xiuxian HE ; Kun LI
Chinese Journal of Nursing 2025;60(7):799-805
Objective To identify the measurement time,assessment tools,changing trends,factors in longitudinal studies on post stroke fatigue.Methods Web of Science,PubMed,CINAHL,Embase,CNKI,CBM,Wanfang,and VIP database were retrieved from inception until December 15,2024.Results A total of 41 papers were included.The measurement time points used with high frequency were 3,6,and 12 months after stroke.10 assessment tools were retrieved and the fatigue severity scale was most selected.The majority of the studies supported that the incidence of post stroke fatigue showed a decreasing trend within 6 months after stroke,an increasing trend from 6 to 12 months,and a decreasing or steady decreasing trend from 12 months.Post stroke fatigue is influenced by demographic,disease,physiologic,psychological,and coping factors.Conclusion The longitudinal studies on post stroke fatigue focused less than 1 year after stroke,but the recovery period is understudied and specific assessment tools need to be further explored.The trend of post stroke fatigue varies at different stages and exists heterogeneity.Future studies should be optimized to explore influence factors.

Result Analysis
Print
Save
E-mail