1.Measurement and simulation of secondary neutron energy spectra and doses in proton therapy
Yang YAN ; Changsong HOU ; Zhen ZHANG ; Weiguo ZHU
Chinese Journal of Radiological Health 2026;35(1):23-28
Objective To evaluate the radiation dose levels induced by secondary neutrons at different locations inside proton therapy treatment rooms, and analyze the distribution characteristics of neutron energy spectra by combining experimental measurements with simulations, and to provide a theoretical basis and technical support for radiation protection design and management in proton therapy. Methods Multiple representative measurement points were established in the treatment rooms of two hospital-based proton therapy centers. The DIAMON neutron spectrometer was employed to perform in-situ measurements of secondary neutron doses and energy spectra. Three-dimensional simulation models of treatment rooms were constructed using the FLUKA code to simulate the generation and transport of secondary neutrons. Results Measurements showed that the neutron dose was highest near the target region, reaching up to
2.Comparative analysis of centrifugal and membrane double plasma molecular adsorption systems combined with low-dose plasma exchange in the treatment of liver failure
Yan HU ; Bangqiang ZHU ; Haijing WANG ; Peng YANG ; Wei XU ; Maohong BIAN ; Junfei ZHANG ; Zhen DA ; Yujie DIAO
Chinese Journal of Blood Transfusion 2026;39(7):859-866
Objective: To investigate the efficacy and safety of centrifugal and membrane double plasma molecular adsorption systems (DPMAS) combined with low-dose plasma exchange in the treatment of liver failure. Methods: A retrospective analysis was performed on 60 patients with liver failure treated in our hospital from April 2024 to June 2025. Based on different plasma separation methods, they were divided into the centrifugal DPMAS group (n=30) and the conventional membrane DPMAS group (n=30). The operational parameters, laboratory indicators, and adverse reactions were compared between the two groups. Results: Under the same plasma volume for adsorption and exchange (P>0.05), the centrifugal group showed lower total circulating blood volume, total blood flow rate, and treatment duration compared to the membrane group [10 794 (9 532, 12 637) vs 19 000 (19 000, 21 000) mL, 60 (60, 65) vs 125 (120, 130) mL/min, 169 (141, 193) vs 207 (183, 210) min, P<0.001]. The centrifugal group also had a lower rate of central venous catheter use [(24/30, 80.00%) vs (30/30, 100.00%), P=0.024] and required more calcium supplementation due to sodium citrate anticoagulation [6 (6, 8) vs 2 (2, 2) g, P<0.001]. No significant changes were observed in WBC, Hb, HCT, and PLT levels before and after treatment with the centrifugal group (P>0.05). There was no statistically significant difference in WBC levels before and after membrane group treatment (P=0.199), but the values of Hb, HCT, and PLT showed significant decreases post-treatment compared to pre-treatment [106.50 (102.75, 126.75) vs 123.00 (109.75, 132.00) g/L, 33.20 (29.90, 34.92) vs 34.85 (31.55, 37.52)%, 85.00 (43.25, 139.50) vs 93.00 (61.50, 145.00)×10
/L, P<0.05]. There was no significant difference in coagulation function indexes before and after treatment with centrifugal group (P>0.05). The membrane group showed reduction in fibrinogen (Fib) levels post-treatment [1.50 (1.20, 1.60) vs 1.60 (1.25, 1.80) g/L, P=0.033]. Both groups demonstrated significant decreases in total bilirubin (TBil) and direct bilirubin (DBil) levels after treatment (centrifugal group: 194.70 (107.50, 276.00) vs 239.15 (173.00, 304.17) μmol/L, 101.00 (64.00, 182.30) vs 157.00 (101.00, 195.00) μmol/L; membrane group: 211.50 (118.00, 240.00) vs 263.50 (204.75, 314.00) μmol/L, 188.00 (122.75, 232.25) vs 219.00 (178.50, 267.25) μmol/L, P<0.05]. The incidence of catheter-related complications was lower in the centrifugal group [(2/30, 6.67%) vs (8/30, 26.67%), P=0.038]. Conclusion: The centrifugal DPMAS system demonstrates advantages such as lower blood flow velocity requirements, shorter treatment duration, minimal impact on platelets, and reduced adverse event rates, indicating promising clinical applications.
3.Application of next-generation sequencing technology for the investigation of immunoglobulin variable region characteristics and their prognostic significance in patients with chronic lymphocytic leukemia
Zhen GUO ; Huimin JIN ; Tonglu QIU ; Liying ZHU ; Yujie WU ; Hairong QIU ; Yan WANG ; Yi MIAO ; Hui JIN ; Lei FAN ; Jianyong LI ; Yi XIA ; Chun QIAO
Chinese Journal of Hematology 2025;46(3):261-268
Objective:To elucidate the genomic characteristics of the immunoglobulin (IG) heavy-chain variable region and light-chain variable region, the expression of subclones, and the prognostic significance in patients with CLL.Methods:Blood and/or bone marrow specimens were gathered from a cohort of 36 patients with CLL diagnosed at Jiangsu Province Hospital from December 2018 to May 2023, including 12 cases of B cell receptor (BCR) stereotyped patients. IG heavy-chain (IGH) and light-chain (IG Kappa [IGK] and IG lambda [IGL]) gene rearrangements were performed using next-generation sequencing (NGS) technology to analyze the characteristics and prognostic value in CLL.Results:NGS detection of IG variable region (IGHV) demonstrated a significant correlation and superior consistency with Sanger sequencing ( r=0.957, P < 0.001). Among the 36 patients, the IGH variant (IGHV) was observed in 9 (25.0%) but not in 27 (75.0%) participants. The incidence of the MYD88 mutation was higher among patients with mutated IGHV [1/27 (3.7%) vs 4/9 (44.4%), P=0.00]. A high incidence of trisomy 12 was observed in the IGHV #8/#8B subset [4/11 (36.4%) vs 1/25 (4.0%), P=0.023], which were more likely to develop Richter transformation [8/11 (72.7%) vs 4/25 (16.0%), P=0.002]. In the patient cohort, 36 individuals (36/36, 100.0%) used the IGK variable, whereas 15 individuals (15/36, 41.7%) employed the IGL variable (IGLV). IGLV3 - 21 reported the highest utilization rate in IGLV (5/15, 33.3%). Remarkably, patients with CLL with IGLV3-21 fragments were exclusively observed in the Binet C stage and Rai Phase Ⅲ-Ⅳ, with an incidence of del (13) (q14) at 60.0% (3/5). The median time to first treatment (TTFT) of patients with or without IGLV3 - 21 fragments was 5.2 (1.1 - 41.5) and 9.9 (0.1 - 94.4) months, respectively. Using the total reads threshold of 2.5%, 4 (4/36, 11.1%) samples were detected to have two IGHV productive clones. The median TTFT and overall survival (OS) time were 2.8 (0.9-72.7) and 12.8 months in patients with one mutated clone and 57.5 (32.0-120.7) and 51.8 months in those with two mutated clones, respectively. The median TTFT and OS time were 10.9 (0.3-94.4) and 6.3 (0.1 - 12.5) months in patients with one unmutated clone and 49.9 (22.2 - 211.1) and 30.0 (9.6 - 50.3) months in those with multiple unmutated clones, respectively ( P>0.05) . Conclusions:Detection of IG gene rearrangements using NGS technology not only facilitates the analysis of the IGHV mutation status, dominant clones, and prognostic value but also contributes to the exploration of IGK/IGL gene rearrangement fragments and the utilization of subclones. Further, it provides information about the poor prognosis of IGLV3 - 21 CLL. The shortened survival of the two unmutated clone groups in the IGHV unmutated group may indicate a poor prognosis.
4.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
5.The synergistic effect and mechanism verification of effective components of Biejia-Ezhu against triple-negative breast cancer based on network pharmacology and component compatibility theory
Dou-dou FENG ; Xiao-shan LUO ; Yan-yun MENG ; Jing-zhe ZHAO ; Jiu-long ZHU ; Ya-zhen HUANG ; Qing XIE ; Xiang-Li LING ; Su XIE
Chinese Pharmacological Bulletin 2025;41(5):950-959
Aim To explore the compatibility and po-tential mechanism of effective components of Biejia-Ezhu against triple negative breast cancer(TNBC)and verify it by experiments.Methods Effective compo-nents and targets of Biejia-Ezhu were obtained by TC-MSP and Swiss Target Prediction.Disease targets of TNBC were obtained from OMMI and GeneCards data-bases.The PPI network was constructed using STRING database.GO and KEGG path enrichment analysis was performed using DAVID database.Cytoscape3.9.1 software was used to construct the"drug-component-target-disease"network,screen key targets and compo-nents for molecular docking,and further verify the com-patibility of key components and targets in vitro.Re-sults ① A total of 71 effective components were iden-tified in the Biejia-Ezhu drug pair.There were 146 drug targets associated with the disease.A total of 113 signaling pathways were identified by KEGG analysis.The 71 potential active components of Biejia-Ezhu mainly acted on key targets such as mTORC1,ULK1,TNF,EGFR,ESR1,STAT3,HIF1A,and PTGS2.Mo-lecular docking results showed that glycine and curcu-min were the key active components of Biejia-Ezhu,and both had strong docking activity against key target proteins mTORC1 and ULK1.②The results of in vitro experiment showed that glycine combined with curcu-min significantly inhibited the proliferation and clonal formation ability of TNBC cells(P<0.05),up-regula-ted the expression of autophagy marker LC3 Ⅱ/Ⅰ,down-regulated the expression of EGFR,down-regula-ted the expression of pathway protein mTORC1,p-mTOR,p-ULK1,and promoted the expression of path-way protein ULK1(P<0.05).Conclusion The key component of Biejia-Ezhu against triple-negative breast cancer is glycine-curcumin,the mechanism of which may be related to the regulation of the mTORC1/ULK1 signaling pathway to promote autophagy.
6.Associations between Pesticide Metabolites and Decreased Estimated Glomerular Filtration Rate Among Solar Greenhouse Workers: A Specialized Farmer Group.
Teng Long YAN ; Xin SONG ; Xiao Dong LIU ; Wu LIU ; Yong Lan CHEN ; Xiao Mei ZHANG ; Xiang Juan MENG ; Bin Shuo HU ; Zhen Xia KOU ; Tian CHEN ; Xiao Jun ZHU
Biomedical and Environmental Sciences 2025;38(2):265-269
8.NFKBIE: Novel Biomarkers for Diagnosis, Prognosis, and Immunity in Colorectal Cancer: Insights from Pan-cancer Analysis.
Chen Yang HOU ; Peng WANG ; Feng Xu YAN ; Yan Yan BO ; Zhen Peng ZHU ; Xi Ran WANG ; Shan LIU ; Dan Dan XU ; Jia Jia XIAO ; Jun XUE ; Fei GUO ; Qing Xue MENG ; Ren Sen RAN ; Wei Zheng LIANG
Biomedical and Environmental Sciences 2025;38(10):1320-1325
9.The synergistic effect and mechanism verification of effective components of Biejia-Ezhu against triple-negative breast cancer based on network pharmacology and component compatibility theory
Dou-dou FENG ; Xiao-shan LUO ; Yan-yun MENG ; Jing-zhe ZHAO ; Jiu-long ZHU ; Ya-zhen HUANG ; Qing XIE ; Xiang-Li LING ; Su XIE
Chinese Pharmacological Bulletin 2025;41(5):950-959
Aim To explore the compatibility and po-tential mechanism of effective components of Biejia-Ezhu against triple negative breast cancer(TNBC)and verify it by experiments.Methods Effective compo-nents and targets of Biejia-Ezhu were obtained by TC-MSP and Swiss Target Prediction.Disease targets of TNBC were obtained from OMMI and GeneCards data-bases.The PPI network was constructed using STRING database.GO and KEGG path enrichment analysis was performed using DAVID database.Cytoscape3.9.1 software was used to construct the"drug-component-target-disease"network,screen key targets and compo-nents for molecular docking,and further verify the com-patibility of key components and targets in vitro.Re-sults ① A total of 71 effective components were iden-tified in the Biejia-Ezhu drug pair.There were 146 drug targets associated with the disease.A total of 113 signaling pathways were identified by KEGG analysis.The 71 potential active components of Biejia-Ezhu mainly acted on key targets such as mTORC1,ULK1,TNF,EGFR,ESR1,STAT3,HIF1A,and PTGS2.Mo-lecular docking results showed that glycine and curcu-min were the key active components of Biejia-Ezhu,and both had strong docking activity against key target proteins mTORC1 and ULK1.②The results of in vitro experiment showed that glycine combined with curcu-min significantly inhibited the proliferation and clonal formation ability of TNBC cells(P<0.05),up-regula-ted the expression of autophagy marker LC3 Ⅱ/Ⅰ,down-regulated the expression of EGFR,down-regula-ted the expression of pathway protein mTORC1,p-mTOR,p-ULK1,and promoted the expression of path-way protein ULK1(P<0.05).Conclusion The key component of Biejia-Ezhu against triple-negative breast cancer is glycine-curcumin,the mechanism of which may be related to the regulation of the mTORC1/ULK1 signaling pathway to promote autophagy.
10.Comparative efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation
Xinnan CHENG ; Shuai LI ; Jiaojiao BAI ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhen CHANG ; Zhigang ZHAO ; Yunfei HUANG ; Mingzhe FENG ; Liang YAN ; Hua HUI ; Lingbo KONG ; Baorong HE
Chinese Journal of Trauma 2025;41(2):148-156
Objective:To compare the clinical efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation.Methods:A retrospective cohort study was conducted to analyze the clinical data of 49 patients with fracture and dislocation of the lower cervical spine who were admitted to Honghui Hospital, Xi′an Jiaotong University School of Medicine from May 2021 to October 2022, including 38 males and 11 females, aged 29-61 years [(39.3±7.3)years]. Injury segments involved C 3 in 12 patients, C 4 in 11, C 5 in 8, C 6 in 9 and C 7 in 9. Twenty-one patients were treated with S8 navigation system (navigation group, 84 screws), and 28 with TINAVI orthopedic robot (robot group, 112 screws). The two groups were compared in terms of the total surgical duration, single screw placement time, total screw placement time, distance between the screw and the anterior cortex, incision length, intraoperative radiation dose, intraoperative blood loss and length of hospital stay. The height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and American Spinal Injury Association (ASIA) grade were assessed before surgery and at 3 days after surgery. Visual analogue scale (VAS), Japanese Orthopedic Association (JOA) score and neck dysfunction index (NDI) before surgery, at 3 days, 3 months after surgery and at the last follow-up were compared. The accuracy of screw placement, intraoperative invasion rate of adjacent facet joints and rate of postoperative complications (infection, screw loosening, etc.) were evaluated. Results:All the patients were followed up for 12-16 months [(13.6±1.9)months]. In the navigation group, the total surgical duration, distance from the screw to the anterior cortex and the intraoperative radiation dose were (236.2±30.6)minutes, (2.0±0.2)mm and (374.3±90.3)mGy respectively, which were significantly shorter or less than those in the robot group [(278.4±20.7)minutes, (10.6±2.9)mm and (448.4±77.9)mGy] ( P<0.01). The single screw placement time, total screw placement time, incision length and intraoperative blood loss were (3.5±0.4)minutes, (23.9±0.5)minutes, (9.1±2.4)cm and (422.2±30.4)ml respectively, which were significantly longer or more than those in the robot group [(2.6±0.2)minutes, (17.9±0.7)minutes, (6.6±2.6)cm and (360.3±56.3)ml] ( P<0.01). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). No significant differences were observed in the height of the intervertebral space, Cobb angle, sliding distance between the vertebral bodies and ASIA grade between the two groups ( P>0.05). At 3 days after surgery, the height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and ASIA grade in both groups were significantly improved when compared with those before surgery ( P<0.05 or 0.01). There were no significant differences in VAS, JOA scores or NDI between the two groups before surgery, at 3 days, 3 months after surgery and at the last follow-up ( P>0.05). The VAS, JOA scores and NDI in both groups were gradually improved at 3 days, 3 months and at the last follow-up after surgery when compared with those before surgery ( P<0.05). There was no significant difference in the accuracy of screw placement of levels 0 and 0+1 between the two groups ( P>0.05). No significant difference in the intraoperative invasion rate of adjacent facet joints between the two groups was found ( P>0.05). There were no serious complications such as infection or screw loosening after surgery in both groups. Conclusions:For lower cervical fracture and dislocation, although there are more advantages in total surgical duration, screw holding force and radiation control regarding the navigation system, and more outstanding performance in screw placement efficiency, incision length and intraoperative blood loss regarding the orthopedic robot, both of them can effectively rebuild the cervical structure, improve neurological function, relieve postoperative pain, improve screw placement accuracy and reduce facet joint injury and serious complications. Selection of the best auxiliary screw placement system should comprehensively consider patients′ conditions and the experience of the surgical team.

Result Analysis
Print
Save
E-mail