1.Role of endoplasmic reticulum stress-mediated DEAD-box helicase 3 X-linked in a mouse model of concanavalin A-induced immune-mediated liver injury
Zhenzhen PAN ; Ling XU ; Xianru ZHU ; Zihao FAN ; Yaling CAO ; Yinkang MO ; Sai YAN ; Feng REN
Journal of Clinical Hepatology 2026;42(1):134-142
ObjectiveTo investigate the role of DEAD-box helicase 3 X-linked (DDX3X) in immune-mediated liver injury (ILI), and to clarify its mechanism by regulating endoplasmic reticulum stress (ERS)-dependent apoptotic pathway and its association with the clinical progression of hepatitis B. MethodsMice were given injection of concanavalin A (ConA) via the caudal vein to establish a model of ILI, PBS (control group) and different concentrations of ConA were injected into the tail vein of hepatocyte-specific DDX3X-knockout mice (DDX3XΔHep and DDX3X-flox mice (DDX3Xfl/fl), respectively.. The log-rank survival analysis, measurement of the serum levels of aspartate aminotransferase (AST) and alanine aminotransferase (ALT), and HE staining of liver tissue were performed to assess liver injury, and qRT-PCR and Western Blot were used to measure the mRNA and protein expression levels of glucose-regulated protein 78 (GRP78), CCAAT/enhancer-binding protein homologous protein (CHOP), and DDX3X in liver tissue. Intraperitoneal injection of 4-phenylbutyric acid (4-PBA, 100 mg/kg) was performed to inhibit ERS. Serum samples (n=30) and liver tissue samples (n=6) were collected from healthy controls, chronic hepatitis B (CHB) patients, and hepatitis B virus-associated liver failure (HBV-LF) patients; ELISA was used to measure the serum level of DDX3X, and qRT-PCR/Western Blot was used to analyze the expression of targets in liver tissue. A one-way analysis of variance was used for comparison of continuous data between multiple groups, and the least significant difference t-test was used for further comparison between two groups. ResultsCompared with the control group of mice, the expression of DDX3X in the liver of mice induced by ConA was significantly increased after liver injury (P<0.05), and hepatocyte-specific DDX3X knockout increased the 72-hour survival rate of mice by 55% (compared with 20% in the DDX3Xfl/fl group), with significant reductions in the serum levels of ALT and AST (P<0.000 1) and the expression levels of the ERS markers GRP78 and CHOP (P<0.05). After ERS was inhibited by 4-PBA, there was alleviation of liver injury (with reductions in ALT and AST, P <0.001) and a reduction in DDX3X expression (P<0.01). The analysis of clinical samples showed that the mRNA and protein expression levels of liver DDX3X in CHB patients and HBV-LF patients were significantly higher than those in healthy controls (all P<0.01), and there was a significant increase in the serum level of DDX3X in HBV-LF patients (P<0.000 1). ConclusionDDX3X exacerbates ILI by regulating the ERS-dependent apoptotic pathway (GRP78/CHOP), and its expression is associated with the progression of hepatitis B. Therefore, it can be used as a potential therapeutic target.
2.Serological and genetic analysis of a novel 27delC variant in A subgroup: a case report
Yingjun ZHANG ; Yuli ZHU ; Zhihui FENG ; Shuhong YU
Chinese Journal of Blood Transfusion 2025;38(2):280-283
[Objective] To conduct serological identification and molecular mechanism study on a ambiguous ABO blood group. [Methods] Standard serological techniques were used for the forward and reverse typing of ABO blood type. ABO gene coding and regulatory regions were analyzed by PCR after DNA extraction. Monoclonal sequencing was used to detect the haplotypes of the DNA sequence, and bioinformatics analysis was applied to predict the possible translation outcomes of the mutated DNA sequence. [Results] The sample’s red blood cells showed mixed field agglutination with anti-A, and the serum agglutinated with B cells, exhibiting serological characteristics of subtype A. Direct sequencing and monoclonal sequencing analysis of the ABO gene confirmed one allele as O02, the other had a c.27delC mutation compared with A102, which could cause the translation sequence to terminate prematurely at the 19th amino acids. Analysis and prediction suggested that the mutation might affect the function of the transferase through mechanisms such as shifting the initiation codon, altering the reading frame and affecting the splice sites. [Conclusion] This case is a rare A subtype caused by the c.27delC variation, and the impact on the glycosyltransferase may involve multiple mechanisms, which require further research and exploration.
3.Consensus on diagnosis and treatment of adolescent idiopathic scoliosis
Yushu BAI ; Kai CHEN ; Jie SHAO ; Xiao ZHAI ; Ming CHEN ; Weishi LI ; Jianzhong XU ; Bangping QIAN ; Zezhang ZHU ; Feng ZHU ; Chunde LI ; Jianguo ZHANG ; Jianxiong SHEN ; Dingjun HAO ; Xiaodong ZHU ; Junlin YANG ; Xuejun ZHANG ; Xuesong ZHANG ; Fangyi ZHANG ; Qijie WANG ; Wenzhi ZHANG ; Yong HAI ; Jianhua ZHAO ; Yong QIU ; Yan WANG ; Guixing QIU ; Ming LI
Academic Journal of Naval Medical University 2025;46(3):291-300
Adolescent idiopathic scoliosis(AIS)is a complex three-dimensional deformity involving coronal,sagittal,and axial planes,with a prevalence that should not be overlooked.With advancements in technology and in-depth research,an increasing number of hospitals and physicians are exploring standardized diagnostic and treatment approaches for AIS.Comprehensive and in-depth understanding is required for AIS,including its etiology,screening and diagnosis,classification,assessment and examination,treatment options,exploration of current focus,and evaluation of quality of life.Such understanding ensures that the diagnostic and treatment are scientific,standardized,and timely.Based on the principles of evidence-based medicine,a consensus on the diagnosis and treatment of AIS is reached after multiple discussions among spinal surgery experts,aiming to provide reference and guidance for clinical practice.
4.Advances of Metal-Organic Framework Stationary Phases for Gas Chromatographic Separations
Yan JIN ; Wen-Bo LI ; Yu-Chen ZHU ; Bin ZHAO ; Lei LI ; Dan ZHENG ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(1):1-13
Metal-organic frameworks(MOFs)are porous materials composed of metal ions or metal clusters and organic ligands by coordination,which have the advantages of large specific surface area,good thermal stability and adjustable pore size,and have a promising application in gas chromatographic separation.In recent years,MOFs materials have been used as stationary phases for gas chromatography mainly including ZIF,MIL,UiO-66,HKUST-1,IRMOFs,etc.Based on the molecular sieve effect,van der Waals forces,hydrogen bonding and π-π interactions,the pore size,pore microenvironment,unsaturated metal site and special functional group of the MOFs stationary phase materials can be specifically designed and regulated.MOFs materials as stationary phases have unique separation performance for n-alkanes and their isomers,aromatic compounds and their isomers,alcohols/ketones/aldehydes and their isomers,and chiral compounds.The combination of organic polymers and novel nanomaterials with MOFs materials can improve the separation performance and stability of MOFs.Therefore,MOFs materials are expected to be the promising stationary phase that can be applied to gas separation in complex environments.In this article,the research advances of various stationary phases based on MOFs for gas chromatography in recent years were reviewed.The separation performance and separation mechanism of MOFs stationary phases for mixed gas samples were discussed,and the development trends in the future were prospected.
5.Ion Unidirectional Ejection Simulation Study of An Extremely Miniature Hyperbolic Linear Ion Trap
Yun-Fan HE ; Zhuo-Qing YANG ; Yan WANG ; Jiu-Wen SUN ; Yun-Na SUN ; Lu-Yue ZHU ; Di ZHANG ; Feng-Dan WANG ; Min LIU ; Gui-Fu DING ; Jin-Yuan YAO
Chinese Journal of Analytical Chemistry 2025;53(6):885-893
With the increasing demand for dynamic,real-time and rapid qualitative analysis of chemical composition in areas such as emergency response and space exploration,chip-scale mass spectrometers have attracted significant attention.These devices are expected to drive the integration of mass spectrometry with micro/nano-fabrication and intelligent sensing technologies,fostering profound innovation and breakthroughs in analytical chemistry.As an excellent mass analyzer,the ion trap exhibits numerous advantages,and its miniaturization creates favorable conditions for the high-density integration of miniature mass spectrometers.However,the reduction in ion storage capacity may compromise its sensitivity and dynamic range,rendering the study of ion unidirectional ejection in highly miniaturized ion traps of significant practical importance.In this work,a research was conducted on achieving efficient ion unidirectional ejection while maintaining high mass resolution in the extremely miniature hyperbolic linear ion trap(M-HLIT)with a field radius of 1 mm,and an electric field compensation method was proposed,which combined asymmetric electrode stretching and unbalanced RF voltage to achieve high-precision optimization of the electric field composition.Simulations showed that in an ideal structure,this method achieved 100%unidirectional ejection efficiency with the mass resolution of 518,significantly outperforming traditional asymmetric structure method(365)and unbalanced voltage method(321).Following the introduction of ion ejection slots,further optimization through bidirectional stretching and electrical parameters improved the resolution to 790 while maintaining a unidirectional ejection efficiency of 93%.This method eliminated the requirement for additional excitation voltage,offering an ideal solution for the miniature mass analyzer with high detection performance of chip-level mass spectrometers.
6.Construction and Application of"On-Off-On"Fluorescence Sensor for Chlorpromazine Hydrochloride Based on Near Infrared Carbon Quantum Dots
Yu LIN ; Feng TAN ; Yu-Hua SHEN ; Li-Qin ZHU ; Pei-Yao YAN ; Jin-Tao PAN ; Kai-Shun LIU
Chinese Journal of Analytical Chemistry 2025;53(6):934-943
In this work,near infrared carbon quantum dots(NIR-CDs)were synthesized by hydrothermal method using biomass material Clausena lansium leaves.The synthesized NIR-CDs emitted maximum fluorescence signal at 677 nm,which was independent of excitation wavelength.The characterization results showed that there were abundant groups on the surface of NIR-CDs.Pd2+could form non-fluorescent compounds with the surface groups of NIR-CDs,resulting in fluorescence quenching(Fluorescence signal was denoted as F0).Because chlorpromazine hydrochloride(CPZ)parent nucleus contained unoxidized S atom,CPZ could form stable colored complex with Pd2+under acidic conditions.In the presence of CPZ,Pd2+dissociated from the surface of NIR-CDs and bonded with CPZ,so that the fluorescence signal could be restored(Fluorescence signal was denoted as F).An"on-off-on"fluorescence sensor was thus constructed.The fluorescence signal recovery value of NIR-CDs(△F=F-F0)showed a good linear relationship with the concentration of CPZ in the range of 5.68-28.43 μg/mL,and the detection limit(3σ)was 0.078 μg/mL.The sensor was applied to determination of CPZ in pharmaceutical preparations,and the recoveries were 94%-106%.The developed fluorescence sensor was expected to be used in quality control of actual pharmaceutical preparations.
7.Optimization of Laser-Induced Breakdown Spectroscopy Parameters for Phosphorus Detection in Water Using Orthogonal Experiment
Xin-Yan YANG ; Xin WANG ; Wen-Wen ZHOU ; Yi-Heng LI ; Peng ZHU ; Bin WANG ; Xian-Feng ZHENG
Chinese Journal of Analytical Chemistry 2025;53(11):1921-1930
Aerosol-assisted plasma amplification laser-induced breakdown spectroscopy(LIBS)was employed for phosphorus detection in water.To address the multivariate coupling effects in LIBS and nebulization sampling system,an orthogonal experiment was employed to systematically optimize the key experimental parameters.Using the orthogonal experimental design,the parametric effects of laser energy(output voltage),signal acquisition delay,liquid velocity,and gas velocity on the signal to background ratio(SBR)of P I 213.618 nm were evaluated,and the optimal conditions were achieved,including laser energy of 86 mJ,delay time of 3 μs,gas velocity of 1.05 mL/min,and liquid velocity of 60 μL/min,which were in agreement with the control-variable optimization results.Moreover,the SBR response trends at P I 213.618 nm with all experimental parameters was strong in consistency with control-variable optimization results,which demonstrated the validity of the orthogonal array experimental design.This study established an efficient and accurate parameter optimization methodology for complex LIBS systems,significantly advancing the application of LIBS in environmental monitoring.
8.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
9.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
10.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.

Result Analysis
Print
Save
E-mail