1.Distribution of end digits in standardized blood pressure measurement recordings and evaluation of its effect on initial blood pressure readings
Yiming YAN ; Xin ZHANG ; Jiehua CHEN ; Haijuan SHI ; Bin ZHU ; Yanming WANG ; Chuanying CHEN
Journal of Public Health and Preventive Medicine 2026;37(2):175-179
Objective To analyze the distribution status of the end digits of standardized blood pressure measurement recordings in the clinic and the effectiveness of standardized blood pressure measurement for community hypertension screening. Methods The first visit blood pressure measurement data from the Community Health Service Center in Jing'an District, Shanghai from June 2023 to May 2024 were collected and analyzed. According to different measurement methods, the data were divided into two groups: standardized blood pressure measurement and conventional blood pressure measurement. SPSS 19.0 software was used for data analysis. The differences in the distribution balance of the end digits of blood pressure values and the detection rate of blood pressure elevation between the two different groups were analyzed. Results The frequency range of the end digits of blood pressure recorded values in the standardized pressure measurement group was 9.42% to 10.83%, and the detection rate of elevated blood pressure was 24.89%. The conventional pressure measurement group had a preference of the end digit "0", and the detection rate of elevated blood pressure was only 2.12%. The results of multiple logistic regression analysis showed that gender, age, season, and different blood pressure measurement modes were all influencing factors for the detection rate of elevated blood pressure. Conclusion The standardized blood pressure measurement mode in the clinic is suitable for community hypertension screening and pressure measurement, with higher data quality than the conventional pressure measurement mode.
2.Diffusion kurtosis imaging of visual pathways in multiple sclerosis and optic neuromyelitis optica spectrum disorders
Yiqiu WEI ; Yongliang HAN ; Yuhui XU ; Zichun YAN ; Qiyuan ZHU ; Zhuowei SHI ; Yang TANG ; Huajiao WANG ; Bin YANG ; Yixian LI ; Jinzhou FENG ; Yongmei LI
Chinese Journal of Radiology 2025;59(10):1111-1117
Objective:To investigate microstructural alterations in the optic chiasm and optic radiations of multiple sclerosis (MS) and neuromyelitis optica spectrum disorders (NMOSD) based on diffusion kurtosis imaging (DKI).Methods:This study was a cross-sectional study. Retrospective analyses were conducted on the clinical and imaging data of 63 patients with relapsing-remitting MS (RRMS) and 62 patients with NMOSD diagnosed at First Affiliated Hospital of Chongqing Medical University from January 2019 to December 2023. According to the occurrence of optic neuritis (ON), they were categorized into ON-positive MS (ON+MS) group (40 cases), ON-negative MS (ON-MS) group (23 cases), ON-positive NMOSD (ON+NMOSD) group (40 cases) and ON-negative NMOSD (ON-NMOSD) group (22 cases). In addition, 40 healthy controls were enrolled during the same period. DKI data of all subjects were collected, and DKI post-processing was performed to obtain fractional anisotropy (FA), mean kurtosis (MK), axial kurtosis (AK), and radial kurtosis (RK) values of the optic chiasm and bilateral optic radiations. The scores of the mini-mental state examination (MMSE), montreal cognitive assessment (MoCA), and expanded disability status scale (EDSS) were obtained. The Kruskal-Wallis test was used to analyze the differences in DKI parameters of the optic chiasm and bilateral optic radiation among the 5 groups, and the Holm-Bonferroni method was employed for multiple comparison correction in pairwise comparisons.Results:There were statistically significant overall differences in the DKI parameters of the optic chiasm and bilateral optic radiations among healthy control group, ON+MS group, ON-MS group, ON+NMOSD group, and ON-NMOSD group (all P0.05). The FA value of the optic chiasm in ON+NMOSD group was significantly lower than that of healthy control group and ON-MS group, as well as ON-NMOSD group ( P0.05). The FA value of the left optic radiation in ON+NMOSD group was lower than that in healthy control group and the ON-MS group. The RK value of the optic chiasm in ON+MS group was lower than that in the healthy control group and ON-NMOSD group ( P0.05). The MK and RK values of the left optic radiation in ON-MS group were significantly lower than those in the ON+NMOSD group and ON-NMOSD group ( P0.05). Conclusions:NMOSD and RRMS patients demonstrate varying degrees of microstructural damage in the optic chiasm and optic radiations. Differences of DKI parameters suggest different pathological mechanisms of visual pathway damage between NMOSD and MS, which may be helpful for early detection of occult visual pathway lesions.
3.Quality evaluation of"Sangdi"based on HPLC fingerprints combined with chemometrics
Ping LIU ; Shi-ying LUO ; Meng-jia LI ; Xiao-yan TAN ; Jian-bin SUN ; Wei-zao LUO ; Ce TANG ; Yi ZHANG
Chinese Traditional Patent Medicine 2025;47(1):14-21
AIM To evaluate the quality of Tibetan medicine"Sangdi"based on HPLC fingerprints combined with chemometrics.METHODS The analysis was performed on a 30 ℃ thermostatic Welch Ultimate AQ-C18 column(250 mm × 4.6 mm,5 μm),with the mobile phase comprising of acetonitrile-0.2%phosphoric acid flowing at 1 mL/min in a gradient elution manner,and the detection wavelength was set at 245 nm,after which cluster analysis,principal component analysis and orthogonal partial least squares discriminant analysis were performed,the contents of gentiopicroside,sweroside,mangiferin,isoorientin,8-hydroxy-1,3,5-trimethoxyxanthone(R2)and 1,8-dihydroxy-3,7-dimethoxyxanthone(R3)were determined.RESULTS There were 18 common peaks in the fingerprints for 15 batches of samples with the similarities of more than 0.90.Six constituents showed good linear relationships within their own ranges(R 2 ≥ 0.999 2),whose average recoveries were 96.93%-103.58%with the RSDs of 0.82%-2.9%.Various batches of samples were clustered into 2 categories,4 principal components demonstrated the accumulative variance contribution rate of 86.404%,mangiferin,gentiopicroside and isoorientin were taken as quality difference markers.CONCLUSION This stable,reliable and reproducibe method can provide a reference for the comprehensive quality evaluation of"Sangdi".
4.Structural equation analysis and modeling of upper limb WMSDs and their adverse ergonomic factors
Siwu ZHONG ; Ning JIA ; Xin SUN ; Meibian ZHANG ; Qing XU ; Huadong ZHANG ; Ruijie LING ; Yimin LIU ; Gang LI ; Yan YIN ; Hua SHAO ; Jue LI ; Hengdong ZHANG ; Bing QIU ; Dayu WANG ; Qiang ZENG ; Rugang WANG ; Yan YE ; Bin XIAO ; Hua ZOU ; Jianchao CHEN ; Dongxia LI ; Yongquan LIU ; Qinghua SHI ; Jixiang LIU ; Enfei JIANG ; Jun QI ; Liangying MEI ; Xianfeng ZHAO ; Mimi YANG ; Xinwei GUO ; Zhi WANG ; Zhongxu WANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(4):254-263
Objective:To explore the structural relationship between WMSDs in the upper limbs and various risk factors in the occupational population in China, based on a large sample epidemiological survey and structural equation analysis, and to establish a structural equation model, so as to lay a foundation for the prevention and control of such diseases.Methods:The Chinese version of the Musculoskeletal Disorders Electronic Questionnaire was used to conduct a nationwide survey on the prevalence of WMSDs in the upper extremity. Six factors related to WMSDs in the upper extremity were extracted by the classification standard of adverse ergonomic factors and their source and confirmatory factor analysis, including work organization, work type, upper extremity work posture, individual factors, upper extremity fatigue and upper extremity WMSDs. The structural equation analysis was carried out and the structural equation model was established.Results:The incidence of WMSDs and fatigue in the upper limbs was 24.44% and 43.76%, respectively. The adjusted structural equation model fitting indicators were generally up to the standard (GFI=1.000, AGFI=1.000, RMSEA=0.043, NFI=0.808, TLI=0.784) . The four exogenous latent variables of work organization, work type, upper limb work posture and individual factors were correlated. There was a strong positive correlation between job type and upper limb work posture ( r=0.865) , a moderate positive correlation between work organization and job type and upper limb work posture ( r=0.570, 0.490) , and a weak negative correlation between individual factors and the other three exogenous latent variables. Upper limb work posture and individual factors had direct effects on upper limb WMSDs, and the effect coefficients were 0.10 and 0.06, respectively. Upper limb fatigue played a mediating role between work organization, work type, upper limb work posture and upper limb WMSDs. The effect coefficient was 0.46, and the composition ratios of indirect effects were 100.0%, 100.0%, and 38.3%, respectively. The direct path effect of upper limb work posture, individual factors and upper limb WMSDs was weaker than the mediating path through upper limb fatigue. Conclusion:When carrying out the prevention and control of upper limbWMSDs, it is necessary to comprehensively consider the pathogenesis path of upper limb muscle fatigue and upper limb WMSDs caused by work organization, work type, and upper limb work posture, so as to provide theoretical reference for improving the prevention and control level of such diseases.
5.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
6.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.
7.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
8.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
9.Diagnostic performance of various radiological modalities in the detection of sarcopenia within Asian populations: a systematic review
Shi Wei ANG ; Jacqueline LIEW ; Vanessa Malishree DHARMARATNAM ; Vanessa Yi Jean YIK ; Shawn KOK ; Syed AFTAB ; Cherie TONG ; Hui Bing LEE ; Shimin MAH ; Clement YAN ; Bin-Tean TEH ; Frederick H. KOH
Annals of Coloproctology 2025;41(1):27-39
Purpose:
Diagnosing sarcopenia necessitates the measurement of skeletal muscle mass. However, guidelines lack a standardized imaging modality with thresholds validated among Asians. This systematic review compared ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), and bioelectrical impedance analysis (BIA)/body composition monitoring in the detection of sarcopenia within Asian populations.
Methods:
PubMed and Embase were systematically searched for studies analyzing ultrasonography, CT, MRI, and BIA in diagnosing sarcopenia among Asians. Study quality was assessed using the Newcastle-Ottawa scale.
Results:
Pooled findings from 21,598 patients across 25 studies were examined. In receiver operating characteristic analysis, ultrasound displayed a pooled mean area under the curve (AUC) of 0.767 (95% confidence interval [CI], 0.709–0.806), with mean sensitivity of 81.1% (95% CI, 0.744–0.846) and specificity of 73.1% (95% CI, 0.648–0.774), for detecting sarcopenia in Asian populations. CT exhibited an AUC of 0.720 (sensitivity, 54.0%; specificity, 92.0%). MRI demonstrated an AUC of 0.839 (sensitivity, 67.0%; specificity, 66.0%). BIA displayed an AUC of 0.905 (95% CI, 0.842–0.968), 80.7% sensitivity (95% CI, 0.129–0.679), and 82.4% specificity (95% CI, 0.191–0.633).
Conclusion
Various modalities aid in diagnosing sarcopenia, and selection should be individualized. Although only BIA and dual-energy x-ray absorptiometry are recommended by the Asian Working Group for Sarcopenia and the European Working Group on Sarcopenia in Older People, ultrasound imaging may hold diagnostic value for sarcopenia in the Asian population. In certain groups, diagnostic use of CT and MRI is warranted. Future research can standardize and validate modality-specific thresholds and protocols within Asian populations.
10.Expert consensus on the application of nasal cavity filling substances in nasal surgery patients(2025, Shanghai).
Keqing ZHAO ; Shaoqing YU ; Hongquan WEI ; Chenjie YU ; Guangke WANG ; Shijie QIU ; Yanjun WANG ; Hongtao ZHEN ; Yucheng YANG ; Yurong GU ; Tao GUO ; Feng LIU ; Meiping LU ; Bin SUN ; Yanli YANG ; Yuzhu WAN ; Cuida MENG ; Yanan SUN ; Yi ZHAO ; Qun LI ; An LI ; Luo BA ; Linli TIAN ; Guodong YU ; Xin FENG ; Wen LIU ; Yongtuan LI ; Jian WU ; De HUAI ; Dongsheng GU ; Hanqiang LU ; Xinyi SHI ; Huiping YE ; Yan JIANG ; Weitian ZHANG ; Yu XU ; Zhenxiao HUANG ; Huabin LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):285-291
This consensus will introduce the characteristics of fillers used in the surgical cavities of domestic nasal surgery patients based on relevant literature and expert opinions. It will also provide recommendations for the selection of cavity fillers for different nasal diseases, with chronic sinusitis as a representative example.
Humans
;
Nasal Cavity/surgery*
;
Nasal Surgical Procedures
;
China
;
Consensus
;
Sinusitis/surgery*
;
Dermal Fillers


Result Analysis
Print
Save
E-mail