1.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
2.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
3.Curcumin extraction and preparation and optimization of curcumin nanoparticles
Yuhang WANG ; Han ZHANG ; Chaojing ZHANG ; Xurong KOU ; Tongtong JING ; Rimei LIN ; Xinyu LIU ; Shilei LOU ; Hui YAN ; Cong SUN
Chinese Journal of Tissue Engineering Research 2026;30(2):362-374
BACKGROUND:Curcumin is the main active ingredient of turmeric and has significant medicinal value in anti-tumor,anti-inflammatory,antioxidant and other aspects.However,its poor water solubility,unstable chemical properties and easy decomposition lead to difficulty in extracting curcumin and low extraction yield.Therefore,it is particularly important to optimize the curcumin extraction method.OBJECTIVE:To enhance the extraction yield and utilization value of curcumin and optimize the curcumin extraction process and curcumin nanoparticle preparation process.METHODS:Curcumin was extracted from turmeric by ethanol extraction,ultrasonic extraction,ionic liquid extraction,enzyme extraction,and ionic liquid combined with ultrasonic assisted enzyme extraction.The curcumin extraction yield was detected by high performance liquid chromatography;the best extraction method was determined,and subsequent process optimization experiments were carried out.The curcumin extraction yield was the response value with the type of ionic liquid,reaction temperature,ultrasonic time,liquid-to-solid ratio,ionic liquid concentration,and enzyme-drug mass ratio as parameters.The optimal production process of ionic liquid combined with ultrasonic assisted enzyme extraction was determined by single factor combined response surface experiment.The optimal process for preparing curcumin nanoparticles by ionic crosslinking method was determined by single factor combined response surface experiment with acetic acid concentration,chitosan to sodium tripolyphosphate mass ratio,stirring rate,curcumin mass concentration,sodium tripolyphosphate mass concentration,and chitosan mass concentration as parameters,and drug encapsulation efficiency as response value.Curcumin nanoparticles were prepared under the optimal process,and the particle size,polydispersity index,Zata potential value,drug loading,stability,hemolysis rate,and antioxidant capacity in vivo and in vitro of the nanoparticles were detected.RESULTS AND CONCLUSION:(1)Among the five extraction methods,the curcumin yield of ionic liquid combined with ultrasound-assisted enzyme extraction was the highest,and this method was selected as the curcumin extraction method for subsequent experiments.The results of single factor combined response surface experiment showed that the optimal process for curcumin extraction was:ionic liquid selected 1-hexyl-3-methylimidazolium chloride,reaction temperature 55 ℃,liquid-to-solid ratio 40 mL/g,ultrasound time 57 minutes,ionic liquid concentration 57%,enzyme-drug mass ratio 3.5:10,and the obtained turmeric extraction yield was 3.10%.The optimal preparation process of curcumin nanoparticles was:glacial acetic acid concentration 0.5%,chitosan and sodium tripolyphosphate mass ratio 5.0:1,stirring speed 150 r/min,curcumin mass concentration 2.23 mg/mL,sodium tripolyphosphate mass concentration 1.45 mg/mL,chitosan mass concentration 3.63 mg/mL,and the obtained drug encapsulation efficiency was 90.61%.(2)The drug loading of curcumin nanoparticles was(14.49±0.23)%,the average particle size was(76.95±1.65)nm,the polydispersity coefficient was 0.15±0.02,and the Zata potential value was(32.37±1.46)mV.The curcumin nanoparticles had good stability and blood compatibility,did not induce hemolysis,and had stronger antioxidant capacity in vivo and in vitro than free curcumin.(3)The results show that the process optimization not only solves the problems of low extraction yield,poor solubility,and low bioavailability of curcumin,but also enhances its antioxidant activity in vivo and in vitro.
4.Curcumin extraction and preparation and optimization of curcumin nanoparticles
Yuhang WANG ; Han ZHANG ; Chaojing ZHANG ; Xurong KOU ; Tongtong JING ; Rimei LIN ; Xinyu LIU ; Shilei LOU ; Hui YAN ; Cong SUN
Chinese Journal of Tissue Engineering Research 2026;30(2):362-374
BACKGROUND:Curcumin is the main active ingredient of turmeric and has significant medicinal value in anti-tumor,anti-inflammatory,antioxidant and other aspects.However,its poor water solubility,unstable chemical properties and easy decomposition lead to difficulty in extracting curcumin and low extraction yield.Therefore,it is particularly important to optimize the curcumin extraction method.OBJECTIVE:To enhance the extraction yield and utilization value of curcumin and optimize the curcumin extraction process and curcumin nanoparticle preparation process.METHODS:Curcumin was extracted from turmeric by ethanol extraction,ultrasonic extraction,ionic liquid extraction,enzyme extraction,and ionic liquid combined with ultrasonic assisted enzyme extraction.The curcumin extraction yield was detected by high performance liquid chromatography;the best extraction method was determined,and subsequent process optimization experiments were carried out.The curcumin extraction yield was the response value with the type of ionic liquid,reaction temperature,ultrasonic time,liquid-to-solid ratio,ionic liquid concentration,and enzyme-drug mass ratio as parameters.The optimal production process of ionic liquid combined with ultrasonic assisted enzyme extraction was determined by single factor combined response surface experiment.The optimal process for preparing curcumin nanoparticles by ionic crosslinking method was determined by single factor combined response surface experiment with acetic acid concentration,chitosan to sodium tripolyphosphate mass ratio,stirring rate,curcumin mass concentration,sodium tripolyphosphate mass concentration,and chitosan mass concentration as parameters,and drug encapsulation efficiency as response value.Curcumin nanoparticles were prepared under the optimal process,and the particle size,polydispersity index,Zata potential value,drug loading,stability,hemolysis rate,and antioxidant capacity in vivo and in vitro of the nanoparticles were detected.RESULTS AND CONCLUSION:(1)Among the five extraction methods,the curcumin yield of ionic liquid combined with ultrasound-assisted enzyme extraction was the highest,and this method was selected as the curcumin extraction method for subsequent experiments.The results of single factor combined response surface experiment showed that the optimal process for curcumin extraction was:ionic liquid selected 1-hexyl-3-methylimidazolium chloride,reaction temperature 55 ℃,liquid-to-solid ratio 40 mL/g,ultrasound time 57 minutes,ionic liquid concentration 57%,enzyme-drug mass ratio 3.5:10,and the obtained turmeric extraction yield was 3.10%.The optimal preparation process of curcumin nanoparticles was:glacial acetic acid concentration 0.5%,chitosan and sodium tripolyphosphate mass ratio 5.0:1,stirring speed 150 r/min,curcumin mass concentration 2.23 mg/mL,sodium tripolyphosphate mass concentration 1.45 mg/mL,chitosan mass concentration 3.63 mg/mL,and the obtained drug encapsulation efficiency was 90.61%.(2)The drug loading of curcumin nanoparticles was(14.49±0.23)%,the average particle size was(76.95±1.65)nm,the polydispersity coefficient was 0.15±0.02,and the Zata potential value was(32.37±1.46)mV.The curcumin nanoparticles had good stability and blood compatibility,did not induce hemolysis,and had stronger antioxidant capacity in vivo and in vitro than free curcumin.(3)The results show that the process optimization not only solves the problems of low extraction yield,poor solubility,and low bioavailability of curcumin,but also enhances its antioxidant activity in vivo and in vitro.
5.Research topics and frontier trends in neuroimaging ethics
Jiajia YAN ; Tinglu ZHU ; Nannan KOU
Chinese Medical Ethics 2026;39(6):709-717
Scientific bibliometric tools were employed to conduct a visual analysis of literature related to neuroimaging ethics, revealing information such as the core authors and key topics in the field of neuroimaging ethics. From the perspective of neuroethics, it analyzed the research topics of neuroimaging ethics, encompassing the impacts of neuroimaging technologies on foundational research in morality, as well as the ethical issues arising from medical and non-medical applications of neuroimaging technologies. Among these, ethical issues in the medical application of neuroimaging technologies included general ethical concerns such as security challenges, privacy protection, and informed consent in neuroimaging practices, together with specific ethical dilemmas, including ethical challenges in assessing disorders of consciousness, incidental findings, and other aspects. Furthermore, this paper explored the frontier trends in neuroimaging ethics, aiming to provide certain ethical guidance for the advancement and application of neuroimaging technologies.
6.Segmented Time Study and Optimization Strategy for Clinical Application of Ethos Online Adaptive Radiotherapy.
Dandan ZHANG ; Yuhan KOU ; Shilong ZHU ; Xiaoyu LIU ; Meng NING ; Peichao BAN ; Jinyuan WANG ; Changxin YAN ; Zhongjian JU
Chinese Journal of Medical Instrumentation 2025;49(2):134-140
OBJECTIVE:
To analyze the time characteristics of the Ethos online adaptive radiotherapy (OART) process in clinical practice and provide guidance for the comprehensive optimization of each stage of adaptive radiotherapy.
METHODS:
The study involved 61 patients with cervical, rectal, gastric, lung, esophageal, and breast cancers who underwent Ethos OART. The mean ± standard deviation of segmental time, total time, and target volume for these patients were tracked. The time characteristics for different cancer types were evaluated, and the average time for target and organ at risk (OAR) modifications was compared with the average target volume for each cancer type.
RESULTS:
Cervical cancer born the longest total treatment time, while breast cancer had the shortest. For all cancer types except breast cancer, the modification time for target and OAR was the most time-consuming segment. The average time for target and OAR modifications aligned with the trend of the average target volume.
CONCLUSION
The total treatment time for various cancers ranges from 15 to 35 minutes, indicating room for improvement.
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Neoplasms/radiotherapy*
;
Female
7.Associations between Pesticide Metabolites and Decreased Estimated Glomerular Filtration Rate Among Solar Greenhouse Workers: A Specialized Farmer Group.
Teng Long YAN ; Xin SONG ; Xiao Dong LIU ; Wu LIU ; Yong Lan CHEN ; Xiao Mei ZHANG ; Xiang Juan MENG ; Bin Shuo HU ; Zhen Xia KOU ; Tian CHEN ; Xiao Jun ZHU
Biomedical and Environmental Sciences 2025;38(2):265-269
8.Effect of acupuncture on postoperative delirium in diabetic patients undergoing surgery under general anesthesia
Jiaxi LIU ; Qi WANG ; Lingling DING ; Jiaqi NING ; Hai KE ; Zhuoya CHEN ; Bo YU ; Weiming SUN ; Peng CHEN ; Xiang LI ; Shishun KOU ; Reiling ZHOU ; Yudong ZHOU ; Yan GUO ; Mengjie CHEN ; Ruyu YAN ; Jiansheng LUO
Chinese Journal of Anesthesiology 2025;45(10):1313-1316
Objective:To evaluate the effect of acupuncture on postoperative delirium (POD) in diabetic patients undergoing surgery under general anesthesia.Methods:In this randomized controlled trial, 92 diabetic patients of either sex, aged 30-80 yr, with a body mass index of 18-28 kg/m 2, of American Society of Anesthesiologists Physical Status classification Ⅱ or Ⅲ, scheduled for elective surgery under general anesthesia, were divided into 2 groups ( n=46 each) using a table of random numbers: control group (group C) and acupuncture group (group A). Group A received acupuncture at the Baihui (GV20), Shenting (GV24) and Sishencong (EX-HN1) acupoints before anesthesia. The needles were retained for 30 min, with manual stimulation applied every 10 min for 10 s each time. After 4 stimulations, routine anesthesia was carried out. Group C received routine anesthesia only. Regional cerebral oxygen saturation was recorded on admission to the operating room (T 0), after anesthesia induction (T 1), at the start of surgery (T 2), at the end of surgery (T 3), and immediately after tracheal extubation (T 4). The POD developed within 3 days after surgery was assessed. The occurrence of needle-related adverse effects such as fainting, subcutaneous bleeding, and local paresthesia was recorded. Results:Compared with group C, the incidence of POD was significantly reduced, and the regional cerebral oxygen saturation was increased at T 1, 4 in group A ( P<0.05). Conclusions:Acupuncture can decrease the development of POD in diabetic patients undergoing surgery under general anesthesia, which is related to an increase in regional cerebral oxygen saturation.
9.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.
10.Ethical examination of artificial intelligence application in Alzheimer’s disease imaging diagnosis
Chinese Medical Ethics 2025;38(2):179-186
Alzheimer’s disease is a progressive, fatal, and neurodegenerative disease, clinically characterized by gradually developed cognitive and memory function decline, language and visuospatial disorders, and other aspects. It remains incurable and irreversible to date. In clinical settings, Alzheimer’s disease usually faces the possibility of untimely diagnosis, causing difficulties in the early intervention of the disease. Thus, it is essential to improve diagnostic efficiency and help patients diagnose Alzheimer’s disease as early as possible. With the continuous development of artificial intelligence (AI) technology, its application in Alzheimer’s disease imaging diagnosis has shown great potential. Meanwhile, it is also accompanied by many ethical issues. By exploring the ethical challenges brought by AI in the research and application of Alzheimer’s disease imaging diagnosis, such as data security, interpretability, algorithmic discrimination, and disclosure of incidental findings, the paper proposed the corresponding countermeasures, with a view to providing certain ethical guidance for the AI application in medical imaging diagnosis, protecting the rights and interests of subjects/patients, and promoting the healthy development of technology.

Result Analysis
Print
Save
E-mail