1.Research on improvement of multi-source therapy equipment management mode based on total normalized productive maintenance theory
Hong YAN ; Yun ZHANG ; Yuying WANG ; Lisha WANG ; Yacui YUAN
China Medical Equipment 2024;21(1):178-183
Objective:To establish a total normalized productive maintenance(TnPM)model for medical equipment,and to explore its application value in the management of multi-source treatment equipment.Methods:In accordance with the principles of self-management,economic efficiency and dynamic improvement,the TnPM management mode of the medical equipment lifecycle management system was developed.22 multi-source treatment equipment in clinical use in the of department of burn and plastic surgery of The Second Affiliated Hospital of Air Force Medical University were selected and divided into a control group(16 units)and an observation group(18 units,including 12 of control group and 6 newly added units)according to different management modes.The control group implemented the traditional management mode,and the observation group adopted TnPM management mode.The operation quality,comprehensive efficiency and team management capabilities of the two groups were compared.Results:The equipment failure rate of the observation group was(4.82±0.21)%,which was lower than that of traditional group,the self-repair rate,maintenance rate and operating standard rate were(91.63±3.59)%,(96.60±2.47)%and(97.31±1.54)%,respectively,which were higher than those of the control group,the difference was statistically significant(t=2.434,5.246,4.525,5.311,P<0.05).The equipment availability rate,performance index and quality index of the observation group were(90.82±2.78)%,(97.03±2.24)%and(97.85±1.26)%,respectively,which were higher than those of control group,the difference was statistically significant(t=6.231,4.671,5.997,P<0.05).The assessment scores of the personnel involved in the equipment on job responsibilities,basic equipment theory,usage assurance level and management performance of observation group were(93.95±2.81)points,(91.45±2.47)points,(90.75±2.54)points and(93.08±3.34)%,respectively,which higher than those of the control group,the difference was statistically significant(t=2.831,3.979,6.472,4.001,P<0.05).Conclusion:The TnPM management mode can improve the operation quality of equipment in the treatment of clinical patients,reduce the incidence of failure,enhance the comprehensive efficiency of equipment and clinical service level,and promote the construction of a management team.
2.Research on the management of medical equipment in the department of burn and plastic surgery based on the traceability management model of quality control
Min SU ; Wenwen KANG ; Wanjun ZHENG ; Yacui YUAN ; Bo WU ; Ning SU ; Yumin DONG
China Medical Equipment 2024;21(12):143-147
Objective:To explore application effect of traceability management model of a quality control in the management of medical equipment in the department of burns and plastic surgery. Methods:The model architecture of software as a service (SAAS) was adopted,and the data layer,application layer,database operation abstraction layer,and client layer were established. The key traceability points for quality control were analyzed,and the traceability management model of quality control was constructed. A total of 50 commonly used medical equipment in clinical use in the department of burns and plastic surgery at the Second Affiliated Hospital of Air Force Medical University from November 2021 to October 2023 were selected. Equipment use management from November 2021 to October 2022 was conducted using the conventional management method (conventional management). Equipment use management from November 2022 to October 2023 was conducted using the traceability management model of quality control (quality traceability management). A self-made questionnaire was used to investigate the satisfaction of 60 personnel involved in the use,repair,and maintenance of equipment. The quality scores for equipment cleaning and disinfection management,and the evaluation scores for equipment management defects were compared between the two management methods. Results:The scores of equipment cleaning quality,sterilization quality,packaging quality and distribution quality of using the traceability management method of quality were (95.51±3.34),(96.82±4.08),(95.37±3.64) and (97.29±3.22),respectively,all of which were higher than those of the conventional management method,and the differences were statistically significant (t=12.024,9.549,12.156,14.414,P<0.05),respectively. The defect scores of the equipment using the traceability management method of quality were (0.34±0.01) points,(0.12±0.04) points and (0.46±0.14) points,respectively,which were lower than those of the conventional management method,and he differences were statistically significant (t=14.638,13.889,16.968,P<0.05). The satisfaction rate of the 60 managers involved in the use of the equipment was 98.33%(59/60),which was higher than that of the conventional management method,and the difference was statistically significant (x2=5.886,P<0.05). Conclusion:The application of the traceability management model of quality control to the management of medical equipment in the department of burn and plastic surgery can enhance the efficiency of equipment use and operator satisfaction,and improve the quality of equipment management.
3.Research on the management of medical equipment in the department of burn and plastic surgery based on the traceability management model of quality control
Min SU ; Wenwen KANG ; Wanjun ZHENG ; Yacui YUAN ; Bo WU ; Ning SU ; Yumin DONG
China Medical Equipment 2024;21(12):143-147
Objective:To explore application effect of traceability management model of a quality control in the management of medical equipment in the department of burns and plastic surgery. Methods:The model architecture of software as a service (SAAS) was adopted,and the data layer,application layer,database operation abstraction layer,and client layer were established. The key traceability points for quality control were analyzed,and the traceability management model of quality control was constructed. A total of 50 commonly used medical equipment in clinical use in the department of burns and plastic surgery at the Second Affiliated Hospital of Air Force Medical University from November 2021 to October 2023 were selected. Equipment use management from November 2021 to October 2022 was conducted using the conventional management method (conventional management). Equipment use management from November 2022 to October 2023 was conducted using the traceability management model of quality control (quality traceability management). A self-made questionnaire was used to investigate the satisfaction of 60 personnel involved in the use,repair,and maintenance of equipment. The quality scores for equipment cleaning and disinfection management,and the evaluation scores for equipment management defects were compared between the two management methods. Results:The scores of equipment cleaning quality,sterilization quality,packaging quality and distribution quality of using the traceability management method of quality were (95.51±3.34),(96.82±4.08),(95.37±3.64) and (97.29±3.22),respectively,all of which were higher than those of the conventional management method,and the differences were statistically significant (t=12.024,9.549,12.156,14.414,P<0.05),respectively. The defect scores of the equipment using the traceability management method of quality were (0.34±0.01) points,(0.12±0.04) points and (0.46±0.14) points,respectively,which were lower than those of the conventional management method,and he differences were statistically significant (t=14.638,13.889,16.968,P<0.05). The satisfaction rate of the 60 managers involved in the use of the equipment was 98.33%(59/60),which was higher than that of the conventional management method,and the difference was statistically significant (x2=5.886,P<0.05). Conclusion:The application of the traceability management model of quality control to the management of medical equipment in the department of burn and plastic surgery can enhance the efficiency of equipment use and operator satisfaction,and improve the quality of equipment management.
4.Analysis of the drug resistance and the integron resistance gene cassette's characteristics of Shigella flexneri.
Quanping MA ; Yacui LIU ; Jingwen LIU ; Mingxiao YAO ; Guangying YUAN
Chinese Journal of Pediatrics 2015;53(10):765-770
OBJECTIVETo investigate the correlation between Shigella flexneri multi-drug resistance and drug resistance gene cassette of integrons.
METHODAll 79 strains of Shigella flexneri were isolated from the feces of children ranged in age from 6 months to 14 years in some hospitals of Jinan, between May 2009 and April 2012.The resistance was detected by Kirby Bauer agar diffusion method, 1, 2 and 3 integron gene was amplified by PCR, the variable region of positive strains treated with enzyme digestion and determined by Series Analysis.
RESULTAmong 79 Shigella flexneri strains, the resistance rate was 91% (72/79) to ampicillin, chloramphenicol, tetracycline, streptomycin, 70% (55/79) to sulfamethoxazole/trimethoprim, 30% (24/79), 23% (18/79), 33% (26/79) and 32% (25/79) to cefotaxime, ceftazidime, ciprofloxacin and levofloxacin.All 79 strains were susceptible to cefoxitin, imipenem, cefoperazone/sulbactam. The common drug resistance pattern is ampicillin tetracycline-chloramphenicol-streptomycin, accounted for 91% (72/79); 91% (72/79) strains carried integrons of class 1, 86% (68/79) strains carried integrons of class 2, No intI3 was detected. The resistance to ampicillin, streptomycin, tetracycline, chloramphenicol of atypical class 1 integron positive strains was significantly higher than the negative strains (χ² = 35.96, P<0.01). The sequencing results:dfrV was detected in class 1 integron variable regions of 9 strains, dfrA17-aadA5 in 2 strains, blaOXA-30-aadA1 in 70 strains, 2 strains were not detected resistance gene cassette, all resistance gene cassettes were dfrA1-sat1-aadA1 in class 2 integron variable regions.
CONCLUSIONThe muti-drug resistance of Shigella flexneri in Jinan was closely associated with integrons.
Adolescent ; Anti-Bacterial Agents ; pharmacology ; Child ; Child, Preschool ; Drug Resistance, Multiple, Bacterial ; genetics ; Dysentery, Bacillary ; microbiology ; Feces ; microbiology ; Humans ; Infant ; Integrons ; Polymerase Chain Reaction ; Shigella flexneri ; drug effects ; genetics

Result Analysis
Print
Save
E-mail