1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Effects of total extract of Anthriscus sylvestris on immune inflammation and thrombosis in rats with pulmonary arterial hypertension based on TGF-β1/Smad3 signaling pathway.
Ya-Juan ZHENG ; Pei-Pei YUAN ; Zhen-Kai ZHANG ; Yan-Ling LIU ; Sai-Fei LI ; Yuan RUAN ; Yi CHEN ; Yang FU ; Wei-Sheng FENG ; Xiao-Ke ZHENG
China Journal of Chinese Materia Medica 2025;50(9):2472-2483
This study aimed to explore the effects and mechanisms of total extracts from Anthriscus sylvestris on pulmonary hypertension in rats. Sixty male SD rats were divided into normal(NC) group, model(M) group, positive drug sildenafil(Y) group, low-dose A. sylvestris(ES-L) group, medium-dose A. sylvestris(ES-M) group, and high-dose A. sylvestris(ES-H) group. On day 1, rats were intraperitoneally injected with monocrotaline(60 mg·kg~(-1)) to induce pulmonary hypertension, and the rat model was established on day 28. From days 15 to 28, intragastric administration of the respective treatments was performed. After modeling and treatment, small animal echocardiography was used to detect the right heart function of the rats. Arterial blood gas was measured using a blood gas analyzer. Hematoxylin and eosin(HE) staining and Masson staining were performed to observe cardiopulmonary pathological damage. Flow cytometry was used to detect apoptosis in the lung and myocardial tissues and reactive oxygen species(ROS) levels. Western blot was applied to detect the expression levels of transforming growth factor-β1(TGF-β1), phosphorylated mothers against decapentaplegic homolog 3(p-Smad3), Smad3, tissue plasminogen activator(t-PA), and plasminogen activator inhibitor-1(PAI-1) in lung tissue. A blood routine analyzer was used to measure inflammatory immune cell levels in the blood. Enzyme-linked immunosorbent assay(ELISA) was used to detect the expression levels of P-selectin and thromboxane A2(TXA2) in plasma. The results showed that, compared with the NC group, right heart hypertrophy index, right ventricular free wall thickness, right heart internal diameter, partial carbon dioxide pressure(PaCO_2), apoptosis in cardiopulmonary tissue, and ROS levels were significantly increased in the M group. In contrast, the ratio of pulmonary blood flow acceleration time(PAT)/ejection time(PET), right cardiac output, change rate of right ventricular systolic area, systolic displacement of the tricuspid ring, oxygen partial pressure(PaO_2), and blood oxygen saturation(SaO_2) were significantly decreased in the M group. After administration of the total extract of A. sylvestris, right heart function and blood gas levels were significantly improved, while apoptosis in cardiopulmonary tissue and ROS levels significantly decreased. Further testing revealed that the total extract of A. sylvestris significantly decreased the levels of interleukin-1β(IL-1β), interleukin-6(IL-6), and PAI-1 proteins in lung tissue, while increasing the expression of t-PA. Additionally, the extract reduced the levels of inflammatory cells such as leukocytes, lymphocytes, granulocytes, and monocytes in the blood, as well as the levels of P-selectin and TXA2 in plasma. Metabolomics results showed that the total extract of A. sylvestris significantly affected metabolic pathways, including arginine biosynthesis, tyrosine metabolism, and taurine and hypotaurine metabolism. In conclusion, the total extract of A. sylvestris may exert an anti-pulmonary hypertension effect by inhibiting the TGF-β1/Smad3 signaling pathway, thereby alleviating immune-inflammatory responses and thrombosis.
Animals
;
Male
;
Smad3 Protein/metabolism*
;
Transforming Growth Factor beta1/metabolism*
;
Rats, Sprague-Dawley
;
Rats
;
Signal Transduction/drug effects*
;
Hypertension, Pulmonary/genetics*
;
Thrombosis/immunology*
;
Drugs, Chinese Herbal/administration & dosage*
;
Humans
;
Apoptosis/drug effects*
3.Tanreqing Capsules protect lung and gut of mice infected with influenza virus via "lung-gut axis".
Nai-Fan DUAN ; Yuan-Yuan YU ; Yu-Rong HE ; Feng CHEN ; Lin-Qiong ZHOU ; Ya-Lan LI ; Shi-Qi SUN ; Yan XUE ; Xing ZHANG ; Gui-Hua XU ; Yue-Juan ZHENG ; Wei ZHANG
China Journal of Chinese Materia Medica 2025;50(8):2270-2281
This study aims to explore the mechanism of lung and gut protection by Tanreqing Capsules on the mice infected with influenza virus based on "the lung-gut axis". A total of 110 C57BL/6J mice were randomized into control group, model group, oseltamivir group, and low-and high-dose Tanreqing Capsules groups. Ten mice in each group underwent body weight protection experiments, and the remaining 12 mice underwent experiments for mechanism exploration. Mice were infected with influenza virus A/Puerto Rico/08/1934(PR8) via nasal inhalation for the modeling. The lung tissue was collected on day 3 after gavage, and the lung tissue, colon tissue, and feces were collected on day 7 after gavage for subsequent testing. The results showed that Tanreqing Capsules alleviated the body weight reduction and increased the survival rate caused by PR8 infection. Compared with model group, Tanreqing Capsules can alleviate the lung injury by reducing the lung index, alleviating inflammation and edema in the lung tissue, down-regulating viral gene expression at the late stage of infection, reducing the percentage of neutrophils, and increasing the percentage of T cells. Tanreqing Capsules relieved the gut injury by restoring the colon length, increasing intestinal lumen mucin secretion, alleviating intestinal inflammation, and reducing goblet cell destruction. The gut microbiota analysis showed that Tanreqing Capsules increased species diversity compared with model group. At the phylum level, Tanreqing Capsules significantly increased the abundance of Firmicutes and Actinobacteria, while reducing the abundance of Bacteroidota and Proteobacteria to maintain gut microbiota balance. At the genus level, Tanreqing Capsules significantly increased the abundance of unclassified_f_Lachnospiraceae while reducing the abundance of Bacteroides, Eubacterium, and Phocaeicola to maintain gut microbiota balance. In conclusion, Tanreqing Capsules can alleviate mouse lung and gut injury caused by influenza virus infection and restore the balance of gut microbiota. Treating influenza from the lung and gut can provide new ideas for clinical practice.
Animals
;
Drugs, Chinese Herbal/administration & dosage*
;
Mice
;
Lung/metabolism*
;
Mice, Inbred C57BL
;
Capsules
;
Orthomyxoviridae Infections/virology*
;
Gastrointestinal Microbiome/drug effects*
;
Male
;
Humans
;
Female
;
Influenza A virus/physiology*
;
Influenza, Human/virology*
4.Predicting Hepatocellular Carcinoma Using Brightness Change Curves Derived From Contrast-enhanced Ultrasound Images
Ying-Ying CHEN ; Shang-Lin JIANG ; Liang-Hui HUANG ; Ya-Guang ZENG ; Xue-Hua WANG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2025;52(8):2163-2172
ObjectivePrimary liver cancer, predominantly hepatocellular carcinoma (HCC), is a significant global health issue, ranking as the sixth most diagnosed cancer and the third leading cause of cancer-related mortality. Accurate and early diagnosis of HCC is crucial for effective treatment, as HCC and non-HCC malignancies like intrahepatic cholangiocarcinoma (ICC) exhibit different prognoses and treatment responses. Traditional diagnostic methods, including liver biopsy and contrast-enhanced ultrasound (CEUS), face limitations in applicability and objectivity. The primary objective of this study was to develop an advanced, light-weighted classification network capable of distinguishing HCC from other non-HCC malignancies by leveraging the automatic analysis of brightness changes in CEUS images. The ultimate goal was to create a user-friendly and cost-efficient computer-aided diagnostic tool that could assist radiologists in making more accurate and efficient clinical decisions. MethodsThis retrospective study encompassed a total of 161 patients, comprising 131 diagnosed with HCC and 30 with non-HCC malignancies. To achieve accurate tumor detection, the YOLOX network was employed to identify the region of interest (ROI) on both B-mode ultrasound and CEUS images. A custom-developed algorithm was then utilized to extract brightness change curves from the tumor and adjacent liver parenchyma regions within the CEUS images. These curves provided critical data for the subsequent analysis and classification process. To analyze the extracted brightness change curves and classify the malignancies, we developed and compared several models. These included one-dimensional convolutional neural networks (1D-ResNet, 1D-ConvNeXt, and 1D-CNN), as well as traditional machine-learning methods such as support vector machine (SVM), ensemble learning (EL), k-nearest neighbor (KNN), and decision tree (DT). The diagnostic performance of each method in distinguishing HCC from non-HCC malignancies was rigorously evaluated using four key metrics: area under the receiver operating characteristic (AUC), accuracy (ACC), sensitivity (SE), and specificity (SP). ResultsThe evaluation of the machine-learning methods revealed AUC values of 0.70 for SVM, 0.56 for ensemble learning, 0.63 for KNN, and 0.72 for the decision tree. These results indicated moderate to fair performance in classifying the malignancies based on the brightness change curves. In contrast, the deep learning models demonstrated significantly higher AUCs, with 1D-ResNet achieving an AUC of 0.72, 1D-ConvNeXt reaching 0.82, and 1D-CNN obtaining the highest AUC of 0.84. Moreover, under the five-fold cross-validation scheme, the 1D-CNN model outperformed other models in both accuracy and specificity. Specifically, it achieved accuracy improvements of 3.8% to 10.0% and specificity enhancements of 6.6% to 43.3% over competing approaches. The superior performance of the 1D-CNN model highlighted its potential as a powerful tool for accurate classification. ConclusionThe 1D-CNN model proved to be the most effective in differentiating HCC from non-HCC malignancies, surpassing both traditional machine-learning methods and other deep learning models. This study successfully developed a user-friendly and cost-efficient computer-aided diagnostic solution that would significantly enhances radiologists’ diagnostic capabilities. By improving the accuracy and efficiency of clinical decision-making, this tool has the potential to positively impact patient care and outcomes. Future work may focus on further refining the model and exploring its integration with multimodal ultrasound data to maximize its accuracy and applicability.
5.RNA Sequencing Reveals Molecular Alternations of Splenocytes Associated with Anti-FⅧ Immune Response in Hemophilia A Murine Model.
Chen-Chen WANG ; Ya-Li WANG ; Yuan-Hua CAI ; Qiao-Yun ZHENG ; Zhen-Xing LIN ; Ying-Yu CHEN
Journal of Experimental Hematology 2025;33(5):1476-1485
OBJECTIVE:
To investigate the molecular alterations of splenocytes associated with anti-factor Ⅷ (FⅧ) immune response and the underlying mechanisms based on hemophilia A (HA) murine model via RNA sequencing (RNA-seq) technology.
METHODS:
Severe HA mice were immunized with recombinant human factor Ⅷ (rhF8) weekly for 4 weeks to establish an FⅧ inhibitor model. High quality raw data were obtained by using bulk RNA-seq and CASAVA base identification technology, and the differentially expressed genes (DEGs) were identified. The DEGs were statistically classified by gene ontology (GO) annotation to obtain information on the major signaling pathways and biological processes involved in anti-FⅧ immune response in HA mouse splenocytes. The cell clusters, genes, and signaling pathway datasets were comprehensively analyzed by GO, Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analysis and single cell RNA-seq (ScRNA-seq) analysis, respectively. Flow cytometry analysis was used to verify the changes in T follicular helper cells (Tfh) and regulatory T cells (Treg).
RESULTS:
A total of 3731 DEGs was identified, including 2275 genes with up-regulated expression and 1456 genes with down-regulated expression. The DEGs were enriched in helper T cell differentiation, cytokine receptor, T cell receptor signaling pathway, ferroptosis, etc. Uniform Manifold Approximation and Project (UMAP) downscaling and visualization analysis yielded a total number of 11 T/NK cell subsets, visualizing the overall expression distribution of C-X-C chemokine-specific receptor gene cxcr5 among these T/NK cell subsets. Higher expression of cxcr5 was found in activated Tfh from FⅧ inhibitor mice, in comparison to the control group. The visualization using Upset plot R language showed a close interaction between Tfh and Treg. Moreover, the increased frequencies of Tfh and the decreased frequencies of Treg in inhibitor mouse splenocytes were further verified by flow cytometry analysis.
CONCLUSION
Multiple immune cell subsets, signaling pathways, and characteristic genes may be involved in the process of anti-FⅧ immune response in HA mouse splenocytes. The molecules involved in the regulation of Tfh/Treg may play key roles, which provide potential biological targets and therapeutic strategies for HA patients with inhibitors in the future.
Animals
;
Hemophilia A/genetics*
;
Mice
;
Sequence Analysis, RNA
;
Disease Models, Animal
;
Spleen/cytology*
;
T-Lymphocytes, Regulatory/immunology*
;
Humans
;
Signal Transduction
;
Factor VIII/immunology*
;
T-Lymphocytes, Helper-Inducer/immunology*
6.Study on Vibration Characteristics of Deep Brain Stimulator Induced by Magnetic Resonance Gradient Magnetic Field.
Ya CHEN ; Peng CAO ; Sheng HU ; Kai ZHENG ; Xun LIU
Chinese Journal of Medical Instrumentation 2025;49(1):8-14
The gradient coils of MRI equipment can induce vibrations in implantable medical devices, causing periodic vibrations of implantable medical devices with respect to the surrounding tissue. This not only results in instrument failure but also causes discomfort to the patient. Therefore, studying the vibration characteristics of implantable devices under different scanning sequences and the orientation of the device relative to the magnetic field is crucial for comprehending vibration performance. This study observed the vibration spectra of a full cranial bone-implanted neurostimulator by using laser vibrometry under typical rapid imaging sequences and explored the impact of different magnetic field orientations on vibration. The results demonstrated that the rapid echo sequences induced diverse and rich vibration components, whereas the planar echo sequences caused relatively simple vibrations. Additionally, the strongest vibrations normally occurred in the maximum conductive surface parallel to the phase-coded direction. It revealed the factors influencing the vibrations of skull fixation active implantable devices and provided guidance for enhancing device safety and protecting patient well-being during MR examinations.
Vibration
;
Magnetic Resonance Imaging
;
Deep Brain Stimulation/instrumentation*
;
Magnetic Fields
;
Humans
7.Enhanced BBB penetration and microglia-targeting nanomodulator for the two-pronged modulation of chronically activated microglia-mediated neuroinflammation in Alzheimer's disease.
Ya WEI ; Xue XIA ; Xiaorong WANG ; Wenqin YANG ; Siqin HE ; Lulu WANG ; Yongke CHEN ; Yang ZHOU ; Feng CHEN ; Hanmei LI ; Fu PENG ; Guobo LI ; Zheng XU ; Jintao FU ; Huile GAO
Acta Pharmaceutica Sinica B 2025;15(2):1098-1111
Intervention in chronically activated microglia-mediated neuroinflammation is a novel approach to treat Alzheimer's disease (AD). The low permeability of the blood‒brain barrier (BBB) and non-selective distribution in the brain severely restrict AD drugs' disease-modifying efficacy. Here, an immunosuppressant TREM2-lowing antisense oligonucleotides (ASOs) and resveratrol co-loaded cationic liposome is developed as an immune reprogramming nanomodulator modified by acid-cleavable BBB-targeting peptide and microglia-targeting peptide (Res@TcMNP/ASO) for AD management. Res@TcMNP/ASO can enter brain endothelial cells via D-T7 peptides. Then D-T7 undergoes an acid-responsive cleavage, facilitating the escape of Res@MNP/ASO from endo/lysosomes to cross the BBB. The detached Res@MNP/ASO specifically targets M1-phenotype microglia via exposed MG1 peptides to prompt the simultaneous delivery of two drugs into activated microglia. This nanomodulator can not only restore the immune function of microglia through TREM2-lowing ASO but also mitigate the immune stimulation to microglia caused by reactive oxygen species (ROS) through resveratrol, thereby synergistically inhibiting the chronic activation of microglia to alleviate neuroinflammation in AD. Our results indicate that this combination treatment can achieve significant behavioral and cognitive improvements in late APP/PS1 mice.
8.Overview of host-directed antiviral targets for future research and drug development.
Xiaoxia GU ; Mengzhu ZHENG ; Ya GAO ; Shuang LIN ; Xiaotian ZHANG ; Chunmei CHEN ; Hucheng ZHU ; Weiguang SUN ; Yonghui ZHANG
Acta Pharmaceutica Sinica B 2025;15(4):1723-1751
Viruses constitute a significant group of pathogens that have caused numerous fatalities and substantial economic losses in recent years, particularly with the emergence of coronaviruses. While the impact of SARS-CoV-2 appears to be diminishing in daily life, only a limited number of drugs have received approval or emergency use authorization for its treatment. Given the high mutation rate of viral genomes, host-directed agents (HDAs) have emerged as a preferred choice due to their broad applicability and lasting effectiveness. In contrast to direct-acting antivirals (DAAs), HDAs offer several advantages, including broad-spectrum antiviral activities, potential efficacy against future emerging viruses, and a lower likelihood of inducing drug resistance. In our review article, we have synthesized known host-directed antiviral targets that span diverse cellular pathways and mechanisms, shedding light on the intricate interplay between host cells and viruses. Additionally, we have provided a brief overview of the development of HDAs based on these targets. We aim for this comprehensive analysis to offer valuable perspectives and insights that can guide future antiviral research and drug development efforts.
9.Analysis of dosimetric verification results of intensity-modulated radiotherapy for breast cancer based on EPID fraction images
Xiao-hui WU ; Ya-zheng CHEN ; Zu-wen YAO ; Rui LIU ; Yang LIU ; Xiao-hua WANG
Chinese Medical Equipment Journal 2025;46(6):54-58
Objective To investigate the stability and reproducibility of the treatment fractions during the intensity-modulated radiotherapy(IMRT)for breast cancer and the effect of respiratory motion on the dose irradiation of breast cancer radiotherapy by comparing the results of breast cancer dosimetric verification based on fractionated images by an electronic portal imaging device(EPID).Methods A total of 28 IMRT patients admitted to some hospital from January to June 2023 were grouped according to the pathological results and effects of respiratory motion on the accuracy of radiotherapy during clinical treatment,including 14 cases in a breast group and 14 cases in a non-breast group with 8 ones of head and neck tumors,5 ones of esophageal cancer and 1 case of cervical cancer.All the patients underwent a scan with cone beam computed tomography(CBCT)before the first radiotherapy,and image registration was carried out with a positioning CT.An EPID was used to acquire transmission dose images of 10 fractions of radiotherapy,and γ analysis was performed using the RIT 113 QA software to compare the images of the subsequent 9 fractions with those of the first fraction,with the images of the first fraction of radiotherapy as the baseline values.Absolute maximum dose normalization was implemented under the condition of 10%dose assessment threshold,and the γ-pass rates under the 3 criteria of 2%/2 mm,3%/2 mm and 3%/3 mm were counted separately.The fraction dose verification results of the 28 patients were divided into 3 treatment phases of 2-4 times(T1),5-7 times(T2)and 8-10 times(T3)to analyze the stability of dose irradiation during the radiotherapy.SPSS 22.0 software was used for statistical analysis.Results Under the condition of 10%dose assessment threshold,the breast and non-breast groups had the γ-pass rates being(95.80±2.65)%and(94.60±6.59)%under the 2%/2 mm criterion and(98.46±1.31)%and(97.50±3.30)%under the 3%/2 mm criterion respectively,and the differences were statistically significant(all P<0.05).Under the assessment criteria of 2%/2 mm,3%/2 mm and 3%/3 mm,the breast group had the γ-pass rates of fractions of treatment significantly lower than those of the non-breast group(all P<0.05),while the γ-pass rates showed no significant differences at T1,T2 and T3 treatment phases(all P>0.05).Conclusion EPID fraction images contribute to evaluating IMRT accuracy effectively.IMRT has high stability and reproducibility during the treatment cycle,while respiration may result in dose deviation during the fraction radiotherapy for breast cancer,and optical surface tracking technology or active breathing control technology is suggested to be involved in to relieve dose deviation.[Chinese Medical Equipment Journal,2025,46(6):54-58]
10.Role of CHMP4C in gastric cancer development through regulating necroptosis and its action mechanism
Qi-ning GUO ; Ya-ping LI ; Li PEI ; Long-chen YU ; Zheng-dong LUO ; Rui ZHAO ; Zhong-fang NIU ; Xin ZHANG
Chinese Journal of Current Advances in General Surgery 2025;28(2):125-133
Objective:Exploring the role and mechanism of CHMP4C in regulating necroptosis during gastric can-cer development and progression.Method:The expression of CHMP4C in pan-cancer was analyzed by bioinformatics methods,and the expression of CHMP4C was detected in human normal gastric epithelial cells and GC cell lines by RT-qPCR and Western blot.Overexpression or knockdown of CHMP4C was performed in GC cell lines,and the effects of CHMP4C on the growth and proliferation of GC cells were detected using CCK-8 and clone formation assays.The CCK-8 experiment and Hoechst/PI double staining experiment were used to detect the changes in GC cell mortality and PI positive cell ratio after treatment with the necroptsis inducer TSZ or inhibitor necrostatin-1(Nec-1).Western blot assay was used to detect the protein and phosphorylation levels of RIPK1,RIPK3,and MLKL in GC cells.Result:CHMP4C was upregulated in GC tissues and cells.The CCK-8 and clone formation experiments showed that overex-pression of CHMP4C significantly improved the proliferation ability and colony formation efficiency of GC cells,while knockdown of CHMP4C significantly weakened GC cells.Moreover,the results of CCK-8 and Hoechst 33342/PI double staining experiments showed that upregulated CHMP4C could inhibit TSZ induced GC cell death;Nec-1 can reverse the decrease in GC cell viability caused by CHMP4C knockdown.Western blot experiment showed that the levels of p-RIPK1,p-RIPK3,and p-MLKL were significantly decreased in overexpressing cells,while they were increased in knockdown cells.After treatment with Nec-1,the expression levels of these three proteins decreased in knockdown cells.Conclusion:CHMP4C may promote GC progression by negatively regulating necroptosis through inhibiting the phosphorylation of the RIPK1/RIPK3/MLKL signaling pathway,suggesting that it is expected to be a potential target for GC therapy.

Result Analysis
Print
Save
E-mail