1.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
3.Research progress of intelligent reversible drug delivery system
Ke-xin CONG ; Xiao-dan SONG ; Ya-nan SUN ; Chao-xing HE ; Shao-kun YANG ; De-ying CAO ; Jing BAI ; Jia ZHANG ; Bai XIANG
Acta Pharmaceutica Sinica 2023;58(3):483-493
In the research on cancer theranostics, most environment-sensitive drug delivery systems can only achieve unidirectional and irreversible responsive changes under pathological conditions, thereby improving the targeting effect and drug release performance of the delivery system. However, such irreversible changes pose potential safety hazards when the dynamically distributed delivery system returns to the blood circulation or transports to the normal physiological environment. Intelligent reversible drug delivery systems can respond to normal physiological and pathological microenvironments to achieve bidirectional and reversible structural changes. This feature will help to precisely control the drug release of the delivery system, prolong the blood circulation time, improve the targeting efficiency, and avoid the potential safety hazards of the irreversible drug delivery system. In this review, we describe the research progress of intelligent reversible drug delivery system from two main aspects: controlled drug release and prolonged blood circulation time/enhanced cellular internalization of drug.
4.Epidemiological Survey of Hemoglobinopathies Based on Next-Generation Sequencing Platform in Hunan Province, China.
Hui XI ; Qin LIU ; Dong Hua XIE ; Xu ZHOU ; Wang Lan TANG ; De Guo TANG ; Chun Yan ZENG ; Qiong WANG ; Xing Hui NIE ; Jin Ping PENG ; Xiao Ya GAO ; Hong Liang WU ; Hao Qing ZHANG ; Li QIU ; Zong Hui FENG ; Shu Yuan WANG ; Shu Xiang ZHOU ; Jun HE ; Shi Hao ZHOU ; Fa Qun ZHOU ; Jun Qing ZHENG ; Shun Yao WANG ; Shi Ping CHEN ; Zhi Fen ZHENG ; Xiao Yuan MA ; Jun Qun FANG ; Chang Biao LIANG ; Hua WANG
Biomedical and Environmental Sciences 2023;36(2):127-134
OBJECTIVE:
This study was aimed at investigating the carrier rate of, and molecular variation in, α- and β-globin gene mutations in Hunan Province.
METHODS:
We recruited 25,946 individuals attending premarital screening from 42 districts and counties in all 14 cities of Hunan Province. Hematological screening was performed, and molecular parameters were assessed.
RESULTS:
The overall carrier rate of thalassemia was 7.1%, including 4.83% for α-thalassemia, 2.15% for β-thalassemia, and 0.12% for both α- and β-thalassemia. The highest carrier rate of thalassemia was in Yongzhou (14.57%). The most abundant genotype of α-thalassemia and β-thalassemia was -α 3.7/αα (50.23%) and β IVS-II-654/β N (28.23%), respectively. Four α-globin mutations [CD108 (ACC>AAC), CAP +29 (G>C), Hb Agrinio and Hb Cervantes] and six β-globin mutations [CAP +8 (C>T), IVS-II-848 (C>T), -56 (G>C), beta nt-77 (G>C), codon 20/21 (-TGGA) and Hb Knossos] had not previously been identified in China. Furthermore, this study provides the first report of the carrier rates of abnormal hemoglobin variants and α-globin triplication in Hunan Province, which were 0.49% and 1.99%, respectively.
CONCLUSION
Our study demonstrates the high complexity and diversity of thalassemia gene mutations in the Hunan population. The results should facilitate genetic counselling and the prevention of severe thalassemia in this region.
Humans
;
beta-Thalassemia/genetics*
;
alpha-Thalassemia/genetics*
;
Hemoglobinopathies/genetics*
;
China/epidemiology*
;
High-Throughput Nucleotide Sequencing
5.Considerations on investigation on quality standard of Chinese patent medicine
Li-xing NIE ; Yan-pei WU ; Jing LIU ; Xiao-ru HU ; Feng-yan HE ; Ya-dan WANG ; Qi WANG ; Jian-dong YU ; Zhong DAI ; Feng WEI ; Shuang-cheng MA
Acta Pharmaceutica Sinica 2023;58(8):2260-2270
Chinese patent medicine (CPM) is an important part of traditional and Chinese medicine (TCM). Its quality has direct impact on the safety and effectiveness of clinical use. The quality standard is the pivotal approach to guarantee the quality of CPM. Due to the complex material basis, multitudinous quality influencing factors and unveiled active ingredients, dose-effect
6.Analysis on missed diagnosis or misdiagnosis of anomalous origin of left coronary artery from pulmonary artery by echocardiography from one single medical center.
Shan LIN ; Lin HE ; Li JI ; Yuan PENG ; Kun LIU ; Qing LYU ; Jing WANG ; Yu Man LI ; Li ZHANG ; Ming Xing XIE ; Ya Li YANG
Chinese Journal of Cardiology 2023;51(5):481-489
Objectives: To analyze the reasons of missed diagnosis or misdiagnosis on anomalous origin of left coronary artery from pulmonary artery (ALCAPA) by echocardiography. Methods: This is a retrospective study. Patients with ALCAPA who underwent surgical treatment in Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from August 2008 to December 2021 were included. According to the results of preoperative echocardiography and surgical diagnosis, the patients were divided into confirmed group or missed diagnosis/misdiagnosis group. The results of preoperative echocardiography were collected, and the specific echocardiographic signs were analyzed. According to the experience of the doctors, the echocardiographic signs were divided into four types, namely clear displayed, vague/doubtful displayed, no display and no notice, and the display rate of each sign was calculated (display rate=number of clearly displayed cases/total number of cases×100%). By referring the surgical data, we analyzed and recorded the pathological anatomy and pathophysiological characteristics of the patients, and the rate of missed diagnosis/misdiagnosis of echocardiography in patients with different characteristics was compared. Results: A total of 21 patients were enrolled, including 11 males, aged 1.8 (0.8, 12.3) years (range 1 month to 47 years). Except for one patient with anomalous origin of left anterior descending artery, the others were all originated from the main left coronary artery (LCA). There were 13 cases of ALCAPA in infant and children, and 8 cases of adult ALCAPA. There were 15 cases in the confirmed group (diagnostic accuracy was 71.4% (15/21)), and 6 cases in the missed diagnosis/misdiagnosis group (three cases were misdiagnosed as primary endocardial fibroelastosis, two cases were misdiagnosed as coronary-pulmonary artery fistula; and one case was missed diagnosis). The working years of the physicians in the confirmed group were longer than those in the missed diagnosis/misdiagnosed group ((12.8±5.6) years vs. (8.3±4.7) years, P=0.045). In infants with ALCAPA, the detection rate of LCA-pulmonary shunt (8/10 vs. 0, P=0.035) and coronary collateral circulation (7/10 vs. 0, P=0.042) in confirmed group was higher than that in missed diagnosis/misdiagnosed group. In adult ALCAPA patients, the detection rate of LCA-pulmonary artery shunt was higher in confirmed group than that in missed diagnosis/misdiagnosed group (4/5 vs. 0, P=0.021). The missed diagnosis/misdiagnosis rate of adult type was higher than that of infant type (3/8 vs. 3/13, P=0.410). The rate of missed diagnosis/misdiagnosis was higher in patients with abnormal origin of branches than that of abnormal origin of main trunk (1/1 vs. 5/21, P=0.028). The rate of missed diagnosis/misdiagnosis in patients with LCA running between the main and pulmonary arteries was higher than that distant from the main pulmonary artery septum (4/7 vs. 2/14, P=0.064). The rate of missed diagnosis/misdiagnosis in patients with severe pulmonary hypertension was higher than that in patients without severe pulmonary hypertension (2/3 vs. 4/18, P=0.184). The reasons with an echocardiography missed diagnosis/misdiagnosis rate of≥50% included that (1) the proximal segment of LCA ran between the main and pulmonary arteries; (2) abnormal opening of LCA at the right posterior part of the pulmonary artery; (3) abnormal origin of LCA branches; (4) complicated with severe pulmonary hypertension. Conclusions: Echocardiography physicians' knowledge of ALCAPA and diagnostic vigilance are critical to the accuracy of diagnosis. Attention should be paid to the pediatric cases with no obvious precipitating factors of left ventricular enlargement, regardless of whether the left ventricular function is normal or not, the origin of coronary artery should be routinely explored.
Male
;
Adult
;
Infant
;
Child
;
Humans
;
Bland White Garland Syndrome/diagnostic imaging*
;
Pulmonary Artery/diagnostic imaging*
;
Retrospective Studies
;
Missed Diagnosis
;
Hypertension, Pulmonary
;
Echocardiography
;
Coronary Vessel Anomalies/diagnostic imaging*
7.Response characteristics of tislelizumab combined with chemotherapy in first-line treatment of locally advanced or metastatic non-squamous non-small cell lung cancer.
Shun LU ; Xin Min YU ; Yan Ping HU ; Zhi Yong MA ; Xing Ya LI ; Wei Dong LI ; Yun Peng LIU ; Dong WANG ; Xiu Wen WANG ; Zhe Hai WANG ; Jing Xun WU ; Dian Sheng ZHONG ; Gao Feng LI ; Wan Yu HE ; Yuan Yuan BAO ; Yuan YUAN ; Jing Hui FAN
Chinese Journal of Oncology 2023;45(4):358-367
Objective: To investigate the response characteristics of patients with locally advanced/metastatic non-squamous non-small cell lung cancer (nsq-NSCLC) treated with tislelizumab in combination with chemotherapy in the first line. Methods: Patients with nsq-NSCLC who achieved complete or partial remission after treatment with tislelizumab in combination with chemotherapy or chemotherapy alone in the RATIONALE 304 study, as assessed by an independent review board, were selected to analyze the response characteristics and safety profile of the responders. Time to response (TTR) was defined as the time from randomization to the achievement of first objective response. Depth of response (DpR) was defined as the maximum percentage of tumor shrinkage compared with the sum of the baseline target lesion length diameters. Results: As of January 23, 2020, 128 patients treated with tislelizumab in combination with chemotherapy achieved objective tumor response (responders), representing 57.4%(128/223) of the intention-to-treat population, with a TTR of 5.1 to 33.3 weeks and a median TTR of 7.9 weeks. Of the responders (128), 50.8%(65) achieved first remission at the first efficacy assessment (week 6), 31.3%(40) at the second efficacy assessment (week 12), and 18.0%(23) at the third and subsequent tumor assessments. The percentages of responders who achieved a depth of tumor response of 30% to <50%, 50% to <70% and 70% to 100% were 45.3%(58/128), 28.1%(36/128) and 26.6%(34/128), respectively, with median progression-free survival (PFS) of 9.0 months (95% CI: 7.7 to 9.9 months), 11.5 months (95% CI: 7.7 months to not reached) and not reached (95% CI: 11.8 months to not estimable), respectively. Tislelizumab plus chemotherapy were generally well tolerated in responders with similar safety profile to the overall safety population. Conclusion: Among responders to tislelizumab in combination with chemotherapy for nsq-NSCLC, 82.0%(105/128) achieves response within the first two tumor assessments (12 weeks) and 18.0%(23/128) achieves response at later (18 to 33 weeks) assessments, and there is a trend toward prolonged PFS in responders with deeper tumor response.
Humans
;
Antibodies, Monoclonal, Humanized/therapeutic use*
;
Antineoplastic Combined Chemotherapy Protocols/adverse effects*
;
Carcinoma, Non-Small-Cell Lung/pathology*
;
Lung Neoplasms/pathology*
;
Treatment Outcome
8.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
9.Association of Residential Greenness with the Prevalence of Metabolic Syndrome in a Rural Chinese Population: the Henan Rural Cohort Study.
Ya Ling HE ; Xiao Tian LIU ; Run Qi TU ; Ming Ming PAN ; Miao Miao NIU ; Gong Bo CHEN ; Jian HOU ; Zhen Xing MAO ; Wen Qian HUO ; Shan Shan LI ; Yu Ming GUO ; Chong Jian WANG
Biomedical and Environmental Sciences 2022;35(1):89-94
10.Sleep-improving mechanism of Chaiqin Ningshen Granules in insomnia rats: based on hippocampal metabonomics.
Lin-Ru ZHAO ; Pan HE ; Jie LI ; Ya-Jun ZHANG ; Jing-Xing JIANG ; Ying-Ru WU ; Yue ZHANG ; Jia LI ; Cong LIU ; Xu-Liang HAO
China Journal of Chinese Materia Medica 2022;47(7):1921-1931
With the ultra high performance liquid chromatography-quadruple-electrostatic field orbitrap high resolution mass spectrometry(UHPLC-Q Exactive Orbitrap-MS)-based metabonomics technology, this study aims to analyze the effect of Chaiqin Ningshen Granules(CNG) on endogenous metabolites in insomnia rats of liver depression syndrome and explore the sleep-improving mechanism of this prescription. Parachlorophenylalanine(PCPA, ip) and chronic stimulation were combined to induce insomnia of liver depression pattern in rats, and the effect of CNG on the macroscopic signs, hemorheology, and neurotransmitters in the hippocampus of insomnia rats of liver depression syndrome was observed. After the administration, rat hippocampus was collected for liquid chromatography-mass spectrometry(LC-MS) analysis of the metabolomics. Principal component analysis(PCA), partial least squares discriminant analysis(PLS-DA), and orthogonal partial least squares discriminant analysis(OPLS-DA) were employed for analyzing the metabolites in rat hippocampus and screening potential biomarkers. MetPA was used to yield the related metabolic pathways and metabolic networks. The results show that the drugs can significantly improve the mental state, liver depression, and blood stasis of rats, significantly increase the content of 5-hydroxytryptamine(5-HT) and gamma aminobutyric acid(GABA) in hippocampus(except low-dose CNG), and significantly reduce the content of glucose(Glu)(except low-dose CNG). Among them, estazolam and high-dose CNG had better effect than others. Metabolomics analysis yielded 27 potential biomarkers related to insomnia. MetPA analysis showed 4 metabolic pathways of estazolam in intervening insomnia and 3 metabolic pathways of high-dose CNG in intervening insomnia, involving purine metabolism, glycerophospholipid metabolism, histidine metabolism, and caffeine metabolism. CNG can alleviate insomnia by regulating endogenous differential metabolites and further related metabolic pathways. The result lays a basis for further elucidating the mechanism of CNG in improving sleep.
Animals
;
Biomarkers
;
Chromatography, High Pressure Liquid
;
Drugs, Chinese Herbal/pharmacology*
;
Estazolam
;
Hippocampus/metabolism*
;
Metabolomics/methods*
;
Rats
;
Sleep
;
Sleep Initiation and Maintenance Disorders/drug therapy*

Result Analysis
Print
Save
E-mail