1.The Impact of Reproductive Traits on Psoriasis Risk is Mediated by Education Attainment and Body Mass Index: A Mendelian Randomization Study.
Ya Jia LI ; Qiang Xiang LI ; Zi Qin CAO ; Jian Huang WU
Biomedical and Environmental Sciences 2025;38(3):365-375
OBJECTIVE:
To explore the causality between reproductive traits and risk of psoriasis by using a large Mendelian randomization (MR) study.
METHODS:
A two-sample MR study was performed using summarized statistics from the genome-wide association studies (GWAS) conducted in reproductive traits, as well as GWAS data on overall psoriasis, psoriatic arthritis (PsA), and psoriasis vulgaris (PV). Besides univariable MR (UVMR), multivariable MR and two-step MR was used to calculate the independent effects and quantify the proportion mediated by education or body mass index (BMI).
RESULTS:
Genetically predicted early age at first sexual intercourse (AFS) led to an increased risk of overall psoriasis [odds ratio ( OR) UVMR: 0.54]; 36.13% of this effect was mediated through BMI and 47.79% through educational attainment. The direct negative casual association between age at first birth (AFB)-PsA was dominant ( OR UVMR: 0.76), with 49.61% proportion of the mediation due to BMI. The mediating effect was found for BMI on the AFS-PV relationship, which accounted for 26.27% of the proportion. AFS was inversely associated with the risk of overall psoriasis and PV, with considerable mediation by BMI and educational attainment.
CONCLUSION
Early AFB may cause a higher risk of PsA, while the AFS-PsA association was fully mediated by BMI.
Humans
;
Body Mass Index
;
Psoriasis/etiology*
;
Mendelian Randomization Analysis
;
Educational Status
;
Female
;
Genome-Wide Association Study
;
Risk Factors
;
Male
;
Reproduction
;
Adult
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Post-transplant parvovirus B19 infection and diagnostic research progress
Ya′nan ZHAO ; Zhen SONG ; Yuze ZHU ; Qingtian LI ; Hui LI ; Beiwen WEI ; Jiewen HUANG ; Juanxiu QIN ; Min LI
Chinese Journal of Laboratory Medicine 2025;48(3):412-418
Organ transplantation is an effective treatment for end-stage organ failure, but postoperative infections and rejection reactions are key factors affecting the survival of the patients. Recently, the incidence of human parvovirus B19 (B19V) infection following transplantation has increased. B19V is a non-enveloped virus that primarily infects the upper respiratory tract and exhibits significant tropism for erythroid progenitor cells in the bone marrow, leading to the lysis of erythrocytes and hematological abnormalities. After B19V viremia, it may further infect other cells, triggering inflammatory responses and tissue damage. B19V infection may lead to chronic anemia in organ transplant patients, thereby affecting the success of the transplant and the survival of the patients. Therefore, it is essential to diagnose and monitor B19V infection post-transplantation. Due to the immunosuppressive therapy following transplantation, traditional serological detection methods, such as IgM and IgG antibody tests, are often unreliable. In contrast, molecular biological detection, especially real-time fluorescent quantitative PCR technology, provides more accurate results. However, the diversity of B19V genotypes may lead to the missed detection of some genotypes. Thus, it is necessary to use different detection techniques to improve the diagnostic accuracy of B19 virus infections. Additionally, there is a need to explore more precise diagnostic methods to enhance the early identification and management of B19V infection, further improving the survival and life quality of the patients.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Establishment and application of a method for detecting Toxoplasma gondii based on recombinant polymerase amplification technology
Shao-zheng SONG ; Le-ying GU ; Ying-chao WU ; Ya-qin MENG ; Kang-ying YU ; Xiao-hua HUANG
Chinese Journal of Zoonoses 2025;41(2):107-112
To establish a method for detecting Toxoplasma gondii based on recombinant polymerase amplification(RPA)technology and apply it to clinical sample validation of pet cats.Using the 529 repeat sequence of the Toxoplasma gondii gene as the target gene sequence,primers and probes were designed,and the Rep-529 recombinant plasmid was constructed as the standard.A fluorescent RPA reaction system was established.Dilute the plasmid standard 10 times to different concentrations as the detection template for sensitivity testing;Specific testing was conducted using genomic DNA from several parasitic spe-cies,including Toxoplasma gondii,Cryptosporidium,Neosporidium,Trichinella spiralis,Giardia flagellata,Babesia bo-vis and Theileria annulata as templates;Simultaneously,fluorescence RPA and RT-PCR were used to detect 52 positive and 40 negative cats clinical samples,and the coincidence rate of the detection results of the two methods were compared and ana-lyzed.The RPA reaction system was successfully established using PTRep recombinant plasmid as the standard,ToxD-F/ToxD-R as the primer,and RepD-P as the fluorescent probe.The reaction temperature was constant at 39 ℃,the reaction time was 30 minutes,and the detection sensitivity was 1 copy/μL.There is no significant cross reaction with parasites such as Cryptosporidium,Neosporidium,Trichinella spiralis,Giardia,Babesia bovis and Theileria annulata,and the specificity is good.A total of 92 clinical fecal samples from cats were tested,and the positive coincidence rate of fluorescence RPA detection method was higher than that of conventional RT-PCR method(98.08%vs.82.69%),and the difference of the positive rate was not statistically significant(X2=1.392,P>0.05).The fluorescence RPA detection method for Toxoplasma gondii suc-cessfully established in this study has the characteristics of being fast,sensitive,specific,accurate,and reliable.It can be used as a rapid clinical detection kit for Toxoplasma gondii in cats and other animals,providing new technical support for the subsequent epidemiological monitoring and precise clinical diagnosis of toxoplasmosis in cats,other animals,and humans in the future.
9.Present situation of sensors applied to monitoring of spinal morphology and motion
Shi-yu ZHOU ; Ya-qin LI ; Yang-xi HUANG ; Xiao CHEN ; Jing WANG ; Zhi-min LIANG ; Yu-chen GUO ; Xue YANG ; Ling-li LI
Chinese Medical Equipment Journal 2025;46(6):105-110
The application of sensors to the monitoring of spinal morphology and motion was reviewed in terms of the research object and monitoring index.The present situation of the application of sensors was introduced,such as inertial sensor,stretchable strain sensor and electromagnetic sensor.The deficiencies of sensors applied to the monitoring of spinal morphology and motion were analyzed,and the future directions of the application were pointed out.[Chinese Medical Equipment Journal,2025,46(6):105-110]
10.Establishment and application of a method for detecting Toxoplasma gondii based on recombinant polymerase amplification technology
Shao-zheng SONG ; Le-ying GU ; Ying-chao WU ; Ya-qin MENG ; Kang-ying YU ; Xiao-hua HUANG
Chinese Journal of Zoonoses 2025;41(2):107-112
To establish a method for detecting Toxoplasma gondii based on recombinant polymerase amplification(RPA)technology and apply it to clinical sample validation of pet cats.Using the 529 repeat sequence of the Toxoplasma gondii gene as the target gene sequence,primers and probes were designed,and the Rep-529 recombinant plasmid was constructed as the standard.A fluorescent RPA reaction system was established.Dilute the plasmid standard 10 times to different concentrations as the detection template for sensitivity testing;Specific testing was conducted using genomic DNA from several parasitic spe-cies,including Toxoplasma gondii,Cryptosporidium,Neosporidium,Trichinella spiralis,Giardia flagellata,Babesia bo-vis and Theileria annulata as templates;Simultaneously,fluorescence RPA and RT-PCR were used to detect 52 positive and 40 negative cats clinical samples,and the coincidence rate of the detection results of the two methods were compared and ana-lyzed.The RPA reaction system was successfully established using PTRep recombinant plasmid as the standard,ToxD-F/ToxD-R as the primer,and RepD-P as the fluorescent probe.The reaction temperature was constant at 39 ℃,the reaction time was 30 minutes,and the detection sensitivity was 1 copy/μL.There is no significant cross reaction with parasites such as Cryptosporidium,Neosporidium,Trichinella spiralis,Giardia,Babesia bovis and Theileria annulata,and the specificity is good.A total of 92 clinical fecal samples from cats were tested,and the positive coincidence rate of fluorescence RPA detection method was higher than that of conventional RT-PCR method(98.08%vs.82.69%),and the difference of the positive rate was not statistically significant(X2=1.392,P>0.05).The fluorescence RPA detection method for Toxoplasma gondii suc-cessfully established in this study has the characteristics of being fast,sensitive,specific,accurate,and reliable.It can be used as a rapid clinical detection kit for Toxoplasma gondii in cats and other animals,providing new technical support for the subsequent epidemiological monitoring and precise clinical diagnosis of toxoplasmosis in cats,other animals,and humans in the future.

Result Analysis
Print
Save
E-mail