1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Research progress on chemical constituents, pharmacological effects of Rubi Fructus and predictive analysis of its quality markers.
Bao-Song LIU ; Er-Wei YU ; Ying-Ying SUN ; Yao-Yu SONG ; Ke-Han JIANG ; Ya-Gang SONG ; Ming-San MIAO ; Meng-Fan PENG
China Journal of Chinese Materia Medica 2025;50(4):922-933
Rubi Fructus has a long history of medicinal and edible use in China. It contains chemical components such as terpenes, flavonoids, phenolic acids, fatty acids, and alkaloids, and possesses various pharmacological activities, including antioxidant, anti-inflammatory, hypoglycemic, anti-tumor, anti-osteoporosis, and liver-protective effects. Rubi Fructus is widely applied in medical, health, and food fields. The quality of Rubi Fructus can directly affect the safety and effectiveness of clinical medication. Therefore, this article reviews the research progress on the chemical constituents and pharmacological effects of Rubi Fructus. Based on the concept of traditional Chinese medicine(TCM) quality markers(Q-markers), the article explores the screening and determination of Q-markers for Rubi Fructus from various aspects, including plant kinship, traditional efficacy, medicinal properties, measurability of chemical composition, different processing methods, producing areas, harvesting periods, and planting conditions. The components ellagic acid, kaempferol, quercetin, kaempferol-3-O-rutinoside, rutin, astragalin, tiliroside, and hyperoside are preliminarily proposed as Q-markers for Rubi Fructus, providing a reference for the quality control of Rubi Fructus.
Drugs, Chinese Herbal/pharmacology*
;
Humans
;
Rubus/chemistry*
;
Fruit/chemistry*
;
Quality Control
;
Animals
7.One-year seedling cultivation technology and seed germination-promoting mechanism by warm water soaking of Polygonatum kingianum var. grandifolium.
Ke FU ; Jian-Qing ZHOU ; Zhi-Wei FAN ; Mei-Sen YANG ; Ya-Qun CHENG ; Yan ZHU ; Yan SHI ; Jin-Ping SI ; Dong-Hong CHEN
China Journal of Chinese Materia Medica 2025;50(4):1022-1030
Polygonati Rhizoma demonstrates significant potential for addressing both chronic and hidden hunger. The supply of high-quality seedlings is a primary factor influencing the development of the Polygonati Rhizoma industry. Warm water soaking is often used in agriculture to promote the rapid germination of seeds, while its application and molecular mechanism in Polygonati Rhizoma have not been reported. To rapidly obtain high-quality seedlings, this study treated Polygonatum kingianum var. grandifolium seeds with sand storage at low temperatures, warm water soaking, and cultivation temperature gradients. The results showed that the culture at 25 ℃ or sand storage at 4 ℃ for 2 months rapidly broke the seed dormancy of P. kingianum var. grandifolium, while the culture at 20 ℃ or sand storage at 4 ℃ for 1 month failed to break the seed dormancy. Soaking seeds in 60 ℃ warm water further increased the germination rate, germination potential, and germination index. Specifically, the seeds soaked at 60 ℃ and cultured at 25 ℃ without sand storage treatment(Aa25) achieved a germination rate of 78. 67%±1. 53% on day 42 and 83. 40%±4. 63% on day 77. The seeds pretreated with sand storage at 4 ℃ for 2 months, soaked in 60 ℃ water, and then cultured at 25 ℃ achieved a germination rate comparable to that of Aa25 on day 77. Transcriptomic analysis indicated that warm water soaking might promote germination by triggering reactive oxygen species( ROS), inducing the expression of heat shock factors( HSFs) and heat shock proteins( HSPs), which accelerated DNA replication, transcript maturation, translation, and processing, thereby facilitating the accumulation and turnover of genetic materials. According to the results of indoor controlled experiments and field practices, maintaining a germination and seedling cultivation environment at approximately 25 ℃ was crucial for the one-year seedling cultivation of P. kingianum var. grandifolium.
Germination
;
Seedlings/genetics*
;
Water/metabolism*
;
Seeds/metabolism*
;
Polygonatum/genetics*
;
Temperature
;
Plant Proteins/genetics*
;
Plant Dormancy
8.Cyclometalated iridium(III) complex based on isoquinoline alkaloid synergistically elicits the ICD response and IDO inhibition via autophagy-dependent ferroptosis.
Yuan LU ; Shan-Shan WANG ; Meng-Ya LI ; Rong LIU ; Meng-Fan ZHU ; Liang-Mei YANG ; Feng-Yang WANG ; Ke-Bin HUANG ; Hong LIANG
Acta Pharmaceutica Sinica B 2025;15(1):424-437
The development of anticancer drugs to treat triple-negative breast cancer (TNBC) is an ongoing challenge. Immunogenic cell death (ICD) has garnered considerable interest worldwide as a promising synergistic modality for cancer chemoimmunotherapy. However, only few drugs or treatment modalities can trigger an ICD response and none of them exert a considerable clinical effect against TNBC. Therefore, new agents with potentially effective chemoimmunotherapeutic response are required. In this study, five new cyclometalated Ir(III) complexes containing isoquinoline alkaloid CˆN ligands were designed and synthesized. Among them, Ir-1 exhibited the highest in vitro cytotoxicity. Mechanistically, Ir-1 could trigger autophagy-dependent ferroptosis and a subsequent ferroptosis-dependent ICD response as well as indoleamine 2,3-dioxygenase (IDO) inhibition via reactive oxygen species (ROS)-mediated endoplasmic reticulum (ER) stress in MDA-MB-231 cells. When immunocompetent BALB/c mice were vaccinated with Ir-1-treated dying TNBC cells, antitumor CD8+ T-cell response and Foxp3+ T-cell depletion were induced, resulting in long-lasting antitumor immunity in TNBC cells. Moreover, combination therapy with Ir-1 and anti-PD1 could substantially augment in vivo therapeutic effects. Based on these results, Ir-1 is a promising candidate for chemoimmunotherapy against TNBC and its effects are mediated synergistically via ICD induction and IDO blockage.
9.A systematic review and meta-analysis comparing cardiac CT angiography with transesophageal echocardiography in planning left atrial appendage closure
Jia-Qi LI ; Jing-Chao LU ; Ya-Qiong JIN ; Meng-Xiao WANG ; Jie ZHANG ; Ke-Ke WANG ; Fan LIU
Chinese Journal of Interventional Cardiology 2023;31(12):935-945
Objective To systematically evaluate the differences in preoperative planning for left atrial appendage closure(LAAC)using cardiac CT angiography(CCTA)and transesophageal echocardiography(TEE).Methods Relevant studies comparing CCTA and TEE for preoperative assessment of LAAC published from the inception of each database to July 18,2023,were searched in PubMed,EMBASE,the Cochrane Library,CNKI,Wanfang,and CBM database.Meta-analysis was performed using RevMan 5.4 and Stata 15.1.Results A total of 21 studies with 2 137 patients were included.Compared to TEE,preoperative CCTA measurement of the left atrial appendage(LAA)showed a larger maximum diameter(MD 2.27 mm,95%CI 1.70-2.83,P<0.001)and higher accuracy in predicting occlusion device(RR 1.67,95%CI 1.39-2.01,P<0.001).Subgroup analysis based on whether 3D reconstruction was performed and occlusion device type showed similar results.There was no statistically significant difference in the surgical success rate(RR 1.03,95%CI 0.98-1.08,P=0.230)between the two imaging methods.Additionally,preoperative 3D reconstruction based on CCTA resulted in fewer occlusion devices used(MID-0.29,95%CI-0.53--0.04,P=0.020),less contrast agent usage(MD-4.48 ml,95%CI-7.40—-1.56,P=0.003),shorter operative time(MD-14.98 min,95%CI-17.79—-12.17,P<0.001),and a lower rate of postoperative residual leakage(RR 0.59,95%CI 0.36-0.99,P=0.040).Conclusions Compared to TEE,preoperative CCTA for LAAC improves the accuracy of occlusion device prediction.3D reconstruction based on CCTA reduces the occlusion devices used and the usage of contrast agents,shortens the operative time,improves surgical efficiency,and is associated with a lower rate of postoperative residual leakage.Therefore,CCTA has more advantages in preoperative planning for LAAC.
10.Value of MRI Ovarian-Adnexal Reporting and Data System in Differentiating Benign and Malignant Ovarian-Adnexal Lesions
Wen-hao FU ; Xiao-xiao HU ; Meng-ya SUN ; Fan ZHANG ; Ke WANG ; Guang-lei TANG ; Jian GUAN
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(1):99-105
ObjectiveTo explore the value of MRI ovarian-adnexal reporting and data system (O-RADS MRI) in differentiating benign and malignant ovarian-adnexal masses.MethodsTotally 146 patients (202 masses) with ovarian-adnexal lesions who underwent pelvic examination at 3.0 T MRI according to standardized scan protocol of O-RADS MRI and were pathologically confirmed in The First Affiliated Hospital of Sun Yat-sen University between January 2020 and February 2022 were retrospectively analyzed. Two radiologists classified the ovarian-adnexal masses as risk levels 1~5 according to O-RADS MRI and evaluated their consistency by Cohen’s kappa. Using pathological findings as the gold standard, the detection yield of malignant lesions with O-RADS MRI classification was analyzed. Sensitivity, specificity, accuracy, and the area under the receiver operating characteristic curve were calculated (cutoff for malignancy, score ≥ 4).ResultsOf 202 masses, 62 (30.7%) were malignant, 140 (69.3%) were benign. The two radiologists presented good agreement in O-RADS MRI classification of ovarian adnexal masses (Kappa=0.932). The malignancy rates of masses with scores of 1, 2, 3, 4 and 5 were 0%, 0%, 7.7%, 95%, 97.6%, respectively. Sensitivity, specificity, accuracy, and the area under the receiver operating characteristic curve were 96.8% (60/62), 98.6% (138/140), 98.0% (198/202), 0.977.ConclusionsO-RADS MRI yields high diagnostic efficiency for benign and malignant ovarian adnexal masses and its widespread implementation will improve communication between radiologists and clinicians, and facilitate optimal patient management. Therefore, O-RADS MRI warrants widespread use in clinical setting.

Result Analysis
Print
Save
E-mail