1.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
2.Clinical and genetic characteristics of congenital adrenal hyperplasia: a retrospective analysis.
Cai-Jun WANG ; Ya-Wei ZHANG ; Da-Peng LIU ; Juan JIN ; Zhao-Hui LI ; Jing GUO ; Yao-Dong ZHANG ; Hai-Hua YANG ; Wen-Qing KANG
Chinese Journal of Contemporary Pediatrics 2025;27(11):1367-1372
OBJECTIVES:
To study the clinical and genetic characteristics of children with congenital adrenal hyperplasia (CAH).
METHODS:
Clinical data, laboratory findings, and genetic test results of 63 children diagnosed with CAH at Henan Children's Hospital from January 2017 to December 2024 were retrospectively reviewed.
RESULTS:
Of the 63 patients, the mean age at the first visit was (21 ± 14) days; 29 (46%) were of male sex and 34 (54%) were of female sex. The predominant clinical manifestations were poor weight gain or weight loss (92%, 58/63), poor feeding (84%, 53/63), skin hyperpigmentation (83%, 52/63), and female external genital anomalies (100%, 34/34). Laboratory abnormalities included hyponatremia (87%, 55/63), hyperkalemia (68%, 43/63), metabolic acidosis (68%, 43/63), and markedly elevated 17-hydroxyprogesterone (92%, 58/63), testosterone (89%, 56/63), and adrenocorticotropic hormone (81%, 51/63). Among 49 patients who underwent genetic testing, CYP21A2 variants were identified in 90% (44/49), with c.293-13A/C>G (33%, 30/91) and large deletions/gene conversions (29%, 26/91) being the most frequent; STAR (8%, 4/49) and HSD3B2 (2%, 1/49) variants were also detected. Following hormone replacement therapy, electrolyte disturbances were corrected in 57 cases, with significant reductions in 17-hydroxyprogesterone, adrenocorticotropic hormone, and testosterone levels (P<0.001).
CONCLUSIONS
CAH presenting in neonates or young infants is characterized by electrolyte imbalance, external genital anomalies, and abnormal hormone levels. Genetic testing enables definitive subtype classification; in CYP21A2-related CAH, c.293-13A/C>G is a hotspot variant. These findings underscore the clinical value of genetic testing for early diagnosis and genetic counseling in CAH. Citation:Chinese Journal of Contemporary Pediatrics, 2025, 27(11): 1367-1372.
Humans
;
Adrenal Hyperplasia, Congenital/diagnosis*
;
Male
;
Female
;
Retrospective Studies
;
Infant
;
Infant, Newborn
3.Predicting Postoperative Circulatory Complications in Older Patients: A Machine Learning Approach.
Xiao Yun HU ; Wei Xuan SHENG ; Kang YU ; Jie Tai DUO ; Peng Fei LIU ; Ya Wei LI ; Dong Xin WANG ; Hui Hui MIAO
Biomedical and Environmental Sciences 2025;38(3):328-340
OBJECTIVE:
This study examines utilizes the advantages of machine learning algorithms to discern key determinants in prognosticate postoperative circulatory complications (PCCs) for older patients.
METHODS:
This secondary analysis of data from a randomized controlled trial involved 1,720 elderly participants in five tertiary hospitals in Beijing, China. Participants aged 60-90 years undergoing major non-cardiac surgery under general anesthesia. The primary outcome metric of the study was the occurrence of PCCs, according to the European Society of Cardiology and the European Society of Anaesthesiology diagnostic criteria. The analysis metrics contained 67 candidate variables, including baseline characteristics, laboratory tests, and scale assessments.
RESULTS:
Our feature selection process identified key variables that significantly impact patient outcomes, including the duration of ICU stay, surgery, and anesthesia; APACHE-II score; intraoperative average heart rate and blood loss; cumulative opioid use during surgery; patient age; VAS-Move-Median score on the 1st to 3rd day; Charlson comorbidity score; volumes of intraoperative plasma, crystalloid, and colloid fluids; cumulative red blood cell transfusion during surgery; and endotracheal intubation duration. Notably, our Random Forest model demonstrated exceptional performance with an accuracy of 0.9872.
CONCLUSION
We have developed and validated an algorithm for predicting PCCs in elderly patients by identifying key risk factors.
Aged
;
Aged, 80 and over
;
Female
;
Humans
;
Male
;
Middle Aged
;
Cardiovascular Diseases/etiology*
;
Machine Learning
;
Postoperative Complications/etiology*
;
Risk Factors
;
Randomized Controlled Trials as Topic
;
Secondary Data Analysis
4.Occupational Hazard Factors and the Trajectory of Fasting Blood Glucose Changes in Chinese Male Steelworkers Based on Environmental Risk Scores: A Prospective Cohort Study.
Ming Xia ZOU ; Wei DU ; Qin KANG ; Yu Hao XIA ; Nuo Yun ZHANG ; Liu FENG ; Fei Yue LI ; Tian Cheng MA ; Ya Jing BAO ; Hong Min FAN
Biomedical and Environmental Sciences 2025;38(6):666-677
OBJECTIVE:
We aimed to investigate the patterns of fasting blood glucose (FBG) trajectories and analyze the relationship between various occupational hazard factors and FBG trajectories in male steelworkers.
METHODS:
The study cohort included 3,728 workers who met the selection criteria for the Tanggang Occupational Cohort (TGOC) between 2017 and 2022. A group-based trajectory model was used to identify the FBG trajectories. Environmental risk scores (ERS) were constructed using regression coefficients from the occupational hazard model as weights. Univariate and multivariate logistic regression analyses were performed to explore the effects of occupational hazard factors using the ERS on FBG trajectories.
RESULTS:
FBG trajectories were categorized into three groups. An association was observed between high temperature, noise exposure, and FBG trajectory ( P < 0.05). Using the first quartile group of ERS1 as a reference, the fourth quartile group of ERS1 had an increased risk of medium and high FBG by 1.90 and 2.21 times, respectively (odds ratio [ OR] = 1.90, 95% confidence interval [ CI]: 1.17-3.10; OR = 2.21, 95% CI: 1.09-4.45).
CONCLUSION
An association was observed between occupational hazards based on ERS and FBG trajectories. The risk of FBG trajectory levels increase with an increase in ERS.
Humans
;
Male
;
Adult
;
Blood Glucose/analysis*
;
China
;
Prospective Studies
;
Occupational Exposure/adverse effects*
;
Risk Factors
;
Middle Aged
;
Steel
;
Fasting/blood*
;
Metal Workers
;
East Asian People
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Research on the Application of TaqMan-MGB Probe Method in Detecting MTHFR Gene Polymorphisms
Hong-xuan LIANG ; Liang-hui CHEN ; Xuan-yi ZHENG ; Qiong-lu HUANG ; Kang ZHANG ; Qiu-ping YE ; Ya-qun LIU
Progress in Modern Biomedicine 2025;25(16):2598-2607
Objective:To establish a TaqMan-MGB probe-based method for detecting the polymorphic loci C677T and A1298C of the MTHFR gene.Methods:Specific primers and TaqMan-MGB probes targeting the C677T and A1298C polymorphic loci of the MTHFR gene were designed and optimized based on the gene sequence information.A real-time quantitative PCR detection system was established.Gradient dilution experiments were conducted to determine the limit of detection,and reproducibility experiments were performed to evaluate detection consistency.Specificity was validated using wild-type and mutant plasmid templates.The method was applied to detect 56 clinical samples,and its accuracy and practicality were assessed through comparison with traditional Sanger sequencing.Results:The TaqMan-MGB probe method demonstrated high specificity for detecting the C677T and A1298C loci,with no cross-reactivity between wild-type and mutant probes,enabling accurate genotype differentiation.Sensitivity experiments revealed detection limits of 1.13 × 103 copies/μL for C677T and 8.39 × 101 copies/μL for A1298C.Reproducibility experiments showed coefficients of variation below 1%,indicating stable and reliable results.Among the 56 clinical samples,the overall detection rate for the C677T locus was 86.99%,and for the A1298C locus,it was 97.92%.The TaqMan-MGB method exhibited good concordance with Sanger sequencing results.Conclusion:The TaqMan-MGB method exhibits high specificity,sensitivity,and excellent reproducibility in detecting the polymorphic loci C677T and A1298C of the MTHFR gene,making it suitable for rapid detection in large-scale clinical samples.This method provides an effective molecular diagnostic tool for the early diagnosis and prevention of folate-related diseases.

Result Analysis
Print
Save
E-mail