1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
3.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
4.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
5.Predicting Hepatocellular Carcinoma Using Brightness Change Curves Derived From Contrast-enhanced Ultrasound Images
Ying-Ying CHEN ; Shang-Lin JIANG ; Liang-Hui HUANG ; Ya-Guang ZENG ; Xue-Hua WANG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2025;52(8):2163-2172
ObjectivePrimary liver cancer, predominantly hepatocellular carcinoma (HCC), is a significant global health issue, ranking as the sixth most diagnosed cancer and the third leading cause of cancer-related mortality. Accurate and early diagnosis of HCC is crucial for effective treatment, as HCC and non-HCC malignancies like intrahepatic cholangiocarcinoma (ICC) exhibit different prognoses and treatment responses. Traditional diagnostic methods, including liver biopsy and contrast-enhanced ultrasound (CEUS), face limitations in applicability and objectivity. The primary objective of this study was to develop an advanced, light-weighted classification network capable of distinguishing HCC from other non-HCC malignancies by leveraging the automatic analysis of brightness changes in CEUS images. The ultimate goal was to create a user-friendly and cost-efficient computer-aided diagnostic tool that could assist radiologists in making more accurate and efficient clinical decisions. MethodsThis retrospective study encompassed a total of 161 patients, comprising 131 diagnosed with HCC and 30 with non-HCC malignancies. To achieve accurate tumor detection, the YOLOX network was employed to identify the region of interest (ROI) on both B-mode ultrasound and CEUS images. A custom-developed algorithm was then utilized to extract brightness change curves from the tumor and adjacent liver parenchyma regions within the CEUS images. These curves provided critical data for the subsequent analysis and classification process. To analyze the extracted brightness change curves and classify the malignancies, we developed and compared several models. These included one-dimensional convolutional neural networks (1D-ResNet, 1D-ConvNeXt, and 1D-CNN), as well as traditional machine-learning methods such as support vector machine (SVM), ensemble learning (EL), k-nearest neighbor (KNN), and decision tree (DT). The diagnostic performance of each method in distinguishing HCC from non-HCC malignancies was rigorously evaluated using four key metrics: area under the receiver operating characteristic (AUC), accuracy (ACC), sensitivity (SE), and specificity (SP). ResultsThe evaluation of the machine-learning methods revealed AUC values of 0.70 for SVM, 0.56 for ensemble learning, 0.63 for KNN, and 0.72 for the decision tree. These results indicated moderate to fair performance in classifying the malignancies based on the brightness change curves. In contrast, the deep learning models demonstrated significantly higher AUCs, with 1D-ResNet achieving an AUC of 0.72, 1D-ConvNeXt reaching 0.82, and 1D-CNN obtaining the highest AUC of 0.84. Moreover, under the five-fold cross-validation scheme, the 1D-CNN model outperformed other models in both accuracy and specificity. Specifically, it achieved accuracy improvements of 3.8% to 10.0% and specificity enhancements of 6.6% to 43.3% over competing approaches. The superior performance of the 1D-CNN model highlighted its potential as a powerful tool for accurate classification. ConclusionThe 1D-CNN model proved to be the most effective in differentiating HCC from non-HCC malignancies, surpassing both traditional machine-learning methods and other deep learning models. This study successfully developed a user-friendly and cost-efficient computer-aided diagnostic solution that would significantly enhances radiologists’ diagnostic capabilities. By improving the accuracy and efficiency of clinical decision-making, this tool has the potential to positively impact patient care and outcomes. Future work may focus on further refining the model and exploring its integration with multimodal ultrasound data to maximize its accuracy and applicability.
6.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
7.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
8.Design,numerical simulation and experimental study of novel oxygenator
Ming-Hao YUE ; Shi-Yao ZHANG ; Ji-Nian LI ; Hui-Chao LIU ; Zi-Hua SU ; Ya-Wei WANG ; Zeng-Sheng CHEN ; Shi-Hang LIN ; Jin-Yu LI ; Ya-Ke CHENG ; Yong-Fei HU ; Cun-Ding JIA ; Ming-Zhou XU
Chinese Medical Equipment Journal 2024;45(3):23-28
Objective To design a novel oxygenator to solve the existing problems of extracorporeal membrane oxygenation(ECMO)machine in high transmembrane pressure difference,low efficiency of blood oxygen exchange and susceptibility to thrombosis.Methods The main body of the oxygenator vascular access flow field was gifted with a flat cylindrical shape.The topology of the vascular access was modeled in three dimensions,and the whole flow field was cut into a blood inlet section,an inlet buffer,a heat exchange zone,a blood oxygen exchange zone,an outlet buffer and a blood outlet section.The oxygenator was compared with Quadrox oxygenator by means of ANSYS FLUENT-based simulation and prototype experiments.Results Simulation calculations showed the oxygenator designed was comparable to the clinically used ones in general,and gained advantages in transmembrane pressure difference,blood oxygen exchange and flow uniformity.Experimental results indicated that the oxygenator behaved better than Quadrox oxygenator in transmembrane pressure difference and blood oxygen exchange.Conclusion The oxygenator has advantages in transmem-brane pressure difference,temperature change,blood oxygen ex-change and low probability of thrombosis.[Chinese Medical Equipment Journal,2024,45(3):23-28]
9.Expert consensus on ethical requirements for artificial intelligence (AI) processing medical data.
Cong LI ; Xiao-Yan ZHANG ; Yun-Hong WU ; Xiao-Lei YANG ; Hua-Rong YU ; Hong-Bo JIN ; Ying-Bo LI ; Zhao-Hui ZHU ; Rui LIU ; Na LIU ; Yi XIE ; Lin-Li LYU ; Xin-Hong ZHU ; Hong TANG ; Hong-Fang LI ; Hong-Li LI ; Xiang-Jun ZENG ; Zai-Xing CHEN ; Xiao-Fang FAN ; Yan WANG ; Zhi-Juan WU ; Zun-Qiu WU ; Ya-Qun GUAN ; Ming-Ming XUE ; Bin LUO ; Ai-Mei WANG ; Xin-Wang YANG ; Ying YING ; Xiu-Hong YANG ; Xin-Zhong HUANG ; Ming-Fei LANG ; Shi-Min CHEN ; Huan-Huan ZHANG ; Zhong ZHANG ; Wu HUANG ; Guo-Biao XU ; Jia-Qi LIU ; Tao SONG ; Jing XIAO ; Yun-Long XIA ; You-Fei GUAN ; Liang ZHU
Acta Physiologica Sinica 2024;76(6):937-942
As artificial intelligence technology rapidly advances, its deployment within the medical sector presents substantial ethical challenges. Consequently, it becomes crucial to create a standardized, transparent, and secure framework for processing medical data. This includes setting the ethical boundaries for medical artificial intelligence and safeguarding both patient rights and data integrity. This consensus governs every facet of medical data handling through artificial intelligence, encompassing data gathering, processing, storage, transmission, utilization, and sharing. Its purpose is to ensure the management of medical data adheres to ethical standards and legal requirements, while safeguarding patient privacy and data security. Concurrently, the principles of compliance with the law, patient privacy respect, patient interest protection, and safety and reliability are underscored. Key issues such as informed consent, data usage, intellectual property protection, conflict of interest, and benefit sharing are examined in depth. The enactment of this expert consensus is intended to foster the profound integration and sustainable advancement of artificial intelligence within the medical domain, while simultaneously ensuring that artificial intelligence adheres strictly to the relevant ethical norms and legal frameworks during the processing of medical data.
Artificial Intelligence/legislation & jurisprudence*
;
Humans
;
Consensus
;
Computer Security/standards*
;
Confidentiality/ethics*
;
Informed Consent/ethics*
10.Expression pattern and function of novel gene C12ORF56 in lung cancer
Zeng ZHANG ; Hua-Zhen XU ; Run-He QIN ; Yun-Min HUANG ; Ya-Hao LING ; Wen-Lin CHANG
Chinese Pharmacological Bulletin 2024;40(9):1680-1687
Aim To disclose the subcellular localiza-tion,expression pattern,cellular physiological function and possible molecular mechanism of C12ORF56,a novel gene located at q14.2 of chromosome 12,in the pathogenesis of lung cancer.Methods ONCOMINE database was applied to investigate the mRNA level dif-fering of C12ORF56 between normal and lung cancer tissues.Analysis based on LinkedOmics,Metascape,String and GSEA database or tools provided indication of potential cellular physiological functions of C12ORF56 in the developing of lung cancer.C12ORF56 was knocked down via siRNA and the pro-liferation of NCI-H1073 cells were observed by EdU and CCK-8 assay.RT-qPCR was used to detect the ex-pression level of C12ORF56 of lung cancer cells on dif-ferent cycle phases.The core sequence regions of pro-moter affecting the transcription of C12ORF56 gene were analyzed by Jaspar online-tools and verified by dual-luciferase assay.Results C12ORF56 was highly expressed in lung cancer cells,especially in squamous cell lung cancer.C12ORF56 correlated with cell cy-cle,cancer immune,DNA replication.Knockdown of C12ORF56 reduced NCI-H1703 cell proliferation.Conclusion The up-regulation of C12ORF56 is in-volved in the development of lung cancer by enhancing lung cancer cell proliferation.

Result Analysis
Print
Save
E-mail