1.Construction of a multigene expression system for plants and verification of its function.
Yin-Yin JIANG ; Ya-Nan TANG ; Yu-Ping TAN ; Shu-Fu SUN ; Juan GUO ; Guang-Hong CUI ; Jin-Fu TANG
China Journal of Chinese Materia Medica 2025;50(12):3291-3296
Constructing an efficient and easy-to-operate multigene expression system is currently a crucial part of plant genetic engineering. In this study, a fragment carrying three independent gene expression cassettes and the expression unit of the gene-silencing suppressor protein(RNA silencing suppressor 19 kDa protein, P19) simultaneously was designed and constructed. This fragment was cloned into the commonly used plant expression vector pCAMBIA300, and the plasmid pC1300-TP2-P19 was obtained. Each gene expression cassette consists of different promoters, fusion tags, and terminators. The target gene can be flexibly inserted into the corresponding site through enzymatic digestion and ligation or recombination and fused with different protein tags, which provides great convenience for subsequent detection. The enhanced green fluorescent protein(eGFP) reporter gene was individually constructed into each expression cassette to verify the feasibility of this vector system. The results of tobacco transient expression and laser-confocal microscopy showed that each expression cassette presented independent and normal expression. Meanwhile, the three key enzyme genes in the betanin synthesis pathway, BvCYP76AD, BvDODA1, and DbDOPA5GT, were constructed into the three expression cassettes. The results of tobacco transient expression phenotype, protein immunoblotting(Western blot), and chemical detection of product demonstrated that the three exogenous genes were highly expressed, and the target compound betanin was successfully produced. The above results indicated that the constructed multigene expression system for plants in this study was efficient and reliable and can achieve the co-transformation of multiple plant genes. It can provide a reliable vector platform for the analysis of plant natural product synthesis pathways, functional verification, and plant metabolic engineering.
Nicotiana/metabolism*
;
Genetic Vectors/metabolism*
;
Gene Expression Regulation, Plant
;
Plant Proteins/metabolism*
;
Plants, Genetically Modified/metabolism*
;
Genetic Engineering/methods*
;
Green Fluorescent Proteins/metabolism*
;
Gene Expression
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty.
Hong-Ru ZHANG ; Ya XIAO ; Shu-Qin JIANG ; Jun SUN ; Wen-Hui SHI ; Jin-Bo LI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(4):404-409
OBJECTIVES:
To investigate the association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty (ICPP).
METHODS:
A retrospective study was conducted involving 61 girls diagnosed with ICPP who visited the pediatric growth and development clinic of the Third Affiliated Hospital of Zhengzhou University between January 2022 and September 2024, designated as the ICPP group, and 61 normally developing girls as the control group. The differences in insulin resistance index (homeostasis model assessment of insulin resistance, HOMA-IR), uterine volume, and other indicators between the two groups were compared, and the relationship between insulin resistance and uterine volume in these girls was analyzed.
RESULTS:
The uterine volume and HOMA-IR level in the ICPP group were significantly higher than those in the control group (P<0.05). Correlation analysis revealed that there was a positive correlation between HOMA-IR level and uterine volume in the ICPP group (rs=0.643, P<0.001). Multiple linear regression analysis indicated that as HOMA-IR increased,uterine volume in the girls tended to increase (P<0.05).
CONCLUSIONS
There is an association between insulin resistance and uterine volume in girls with ICPP, and as HOMA-IR increases, uterine volume in the girls also increases.
Humans
;
Female
;
Insulin Resistance
;
Puberty, Precocious/metabolism*
;
Uterus/pathology*
;
Child
;
Retrospective Studies
;
Organ Size
;
Linear Models
8.Unveiling the renoprotective mechanisms of self-assembled herbal nanoparticles from Scutellaria barbata and Scleromitrion diffusum in acute kidney injury: A nano-TCM approach.
Lunyue XIA ; Qunfang YANG ; Kangzhe FU ; Yutong YANG ; Kaiyue DING ; Yuexue HUO ; Lanfang ZHANG ; Yunong LI ; Borong ZHU ; Peiyu LI ; Yijie HUO ; Liang SUN ; Ya LIU ; Haigang ZHANG ; Tao LIU ; Wenjun SHAN ; Lin ZHANG
Acta Pharmaceutica Sinica B 2025;15(8):4265-4284
Acute kidney injury (AKI) is a critical clinical condition characterized by rapid renal function decline, with high morbidity, mortality, and healthcare costs. Traditional Chinese medicine (TCM) has shown potential effects on mitigating oxidative stress and programmed cell death in AKI models. Scutellaria barbata D. Don (SB) and Scleromitrion diffusum (Willd.) R. J. Wang (SD), a classic TCM herbal pair exhibited anti-inflammatory and antioxidant activities. Using advanced chromatographic separation technology, we enriched the effective fractions of water extracts from SB-SD, obtaining self-assembled herbal nanoparticles (SB and SD nanoparticles, SSNPs) rich in flavonoids and terpenoids. These SSNPs demonstrated robust antioxidant properties in vitro and mitigated AKI progression in vivo by activating the nuclear factor erythroid 2-related factor 2 (Nrf2) signaling pathway. Oral administration of SSNPs in mice resulted in absorption into the bloodstream, formation of a protein corona, reduced macrophage phagocytosis, and enhanced bioavailability and renal targeting. Furthermore, we investigated the self-assembly principle of SSNPs using representative flavonoids and terpenoids. Kinetic studies and in situ transmission electron microscopy (in situ TEM) revealed that these compounds self-assemble via supramolecular forces like hydrogen bonding and π-π interactions, forming stable nanostructures. This study elucidates the renoprotective effects and mechanisms of SB and SD, and provides a novel approach for the development of TCM-based nanomedicines, highlighting the potential of nano-TCM in AKI treatment.
9.Protective effect of Sanfeng Tongqiao Dropping Pills against house dust mite-induced allergic asthma in mice
Tong-wen ZUO ; Xiao-qun GU ; Shu-xian SUN ; Lin LI ; Ya-jun SONG ; Fu-man HUANG ; Qian ZHAO ; Kang ZHOU ; Jie ZHENG ; Min HONG
Chinese Traditional Patent Medicine 2025;47(8):2542-2549
AIM To investigate the protective effect of Sanfeng Tongqiao Dropping Pills against house dust mite(HDM)-induced allergic asthma in mice.METHODS Compared to the intact BALB/c mice in the blank control group,the BALB/c mice randomly assigned into the model group,the dexamethasone group(0.67 mg/kg),and the low-dose,medium-dose,and high-dose Sanfeng Tongqiao Dropping Pills groups(15,30 and 60 mg/kg),were induced into acute allergic asthma models via weekly intraperitoneal sensitization with 0.1 mL HDM solution(0.5 mg/mL)for three weeks followed by three consecutive daily intranasal challenges with 10 μL HDM solution(2.5 mg/mL)starting in the third week.The drug administered continuously 7 days after the last excitation.The mice had their airway reactive Penh value detected,their pulmonary pathological changes observed by HE staining,their blood eosinophils(EOS)counted,their Th2 cytokines in lung tissue and serum IgE levels detected by ELISA,and their number of peripheral blood mononuclear cells(PBMC)and pulmonary Th2 cells detected by flow cytometry.Chronic allergic asthma was induced in grouped BALB/c mice through repeated intranasal challenges with 10 μL HDM solution(2.5 mg/mL)administered five times weekly for five consecutive weeks.Drug treatment continued for 14 days following the final challenge.After the final treatment,the mice had their pulmonary pathological changes observed by HE staining,and their levels of Th2 cytokines in B ALF and lung tissue and serum IgE detected by ELISA.RESULTS Compared to the blank control group,the acute allergic asthma model group exhibited increases in Penh value,EOS count and IgE level in serum,IL-4 and IL-5 levels in lung tissue(P<0.01);obvious pulmonary inflammatory cells infiltration,and thickened airway wall;and increase in pulmonary number of Th2 cells(P<0.01).Compared to the model group,the groups intervened with Sanfeng Tongqiao Dropping Pills demonstrated decreased Penh value,serum EOS count,IgE level and IL-5 level in lung tissue(P<0.05,P<0.01);reduced pulmonary inflammatory infiltration and alleviated airway wall thickening;and decreased number of pulmonary Th2 cells.Compared to the blank group,the chronic allergic asthma model group showed obvious pulmonary inflammatory infiltration and airway wall thickening;and increased EOS count and IgE level in serum,IL-4 and IL-13 in lung tissue and IL-14 in BALF(P<0.05,P<0.01).Compared to the model group,the groups intervened with either medium-dose or high-dose Sanfeng Tongqiao Dropping Pills demonstrated reduced pulmonary inflammatory infiltration;and decreased serum EOS count,IgE level,IL-13 in lung tissue and IL-14 in BALF(P<0.05,P<0.01).CONCLUSION Sanfeng Tongqiao Dropping Pills reduce Th2 cells in peripheral blood and lung tissue,suppress type 2 inflammation,and thereby alleviate allergic asthma.
10.A comparative study on the current status of disability assessment and long-term care needs assessment in 49 pilot cities of the long-term care insurance system
Jiali ZHANG ; Hongxiu CHEN ; Yilin WANG ; Ya LIU ; Shihao XU ; Yanyan WANG ; Birong DONG ; Hong SUN ; Xiuying HU
Chinese Journal of Nursing 2025;60(19):2384-2390
Objective To analyze the disability level and long-term care needs assessment policies issued by 49 pilot cities in China's long-term care insurance system,providing insights for further improvement of the system.Methods Policy documents related to long-term care insurance,published between June 2016 and December 2024 on official platforms of local governments,the Ministry of Human Resources and Social Security,the National Healthcare Security Administration,and the National Public Service Platform for Standards Information,were retrieved.A comparative analysis was used to summarize and compare the content of these policy texts.Results Currently,there are 49 pilot cities implementing the long-term care insurance system in China.47 cities have issued disability level assessment standards,with 38 cities adopting the trial standards issued by the National Healthcare Security Administration.In 42 pilot cities,the disability level assessment includes indicators such as activities of daily living,cognitive function,and sensory and communication abilities.22 cities have issued policies related to care needs assessment.In most cities,the care needs assessment partially or fully includes indicators from the disability level assessment.Conclusion There is no national uniformity in disability level assessment standards,and the care needs assessment framework needs further improvement.It is recommended to standardize disability level assessment criteria,clearly delineate the boundaries and content of disability level and care needs assessments,and enhance the development of the care needs assessment system.

Result Analysis
Print
Save
E-mail