1.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
2.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
3.Mechanism of adipose mesenchymal stem cell exosomes inhibiting atopic dermatitis
Jia-qi BI ; Zhao WANG ; Bing-kun WANG ; Chun-yan SUN ; Ya SUN ; Xiao-tong CUI ; Xin PANG ; Xiao-yu WANG ; Jie-qiong WANG
Chinese Pharmacological Bulletin 2025;41(6):1148-1157
Aim To study the mechanism of adipose mesenchymal stem cell exosomes(ASC-exo)inhibition of fluorescein isothiocyanate(FITC)-induced atopic dermatitis(AD).Methods The mouse age,extrac-tion method,and the concentration of a solution of typeⅠ collagen enzyme and other conditions were compared to study the effects on the morphology and quantity of adipose mesenchymal stem cells(ASCs)after extrac-ted.FITC-induced mouse model in vivo was estab-lished and different doses of ASC-exo were given to measure ear thickness,ear weight and ear scratching times of mice.HE staining was used to observe the pathological changes of ear tissue of mice.The non-toxicity of ASC-exo was detected.IgE,IL-5,IL-13 and other cytokines were detected by ELISA.The gene ex-pressions of TSLP,IL-33,occludin,Claudin-1(CLDN-1)and E-cadherin were detected by RT-qPCR.The protein expression was detected by immunohistochemis-try.Results An efficient method for extracting ASCs was established.Compared with the blank group,mice in the model group showed obvious AD symptoms.Compared with the model group,ASC-exo administra-tion group significantly reduced the number of ear scratches,epidermal thickening,inflammatory cell infil-tration and the secretion of Th2 cytokines IL-5 and IL-13.Meanwhile,ASC-exo administration group signifi-cantly increased the expression of structural proteins CLDN-1 and occludin in epithelial cells and decreased the expression of TSLP and IL-33.Conclusions ASC-exo can significantly improve Th2 skin inflamma-tion in AD mice,and its mechanism may be through in-creasing the expression of tight junction proteins and adhesion link protein in epithelial cells,repairing the skin barrier,and inhibiting the key promoters of allergy TSLP and IL-33.
4.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
5.Mechanism of adipose mesenchymal stem cell exosomes inhibiting atopic dermatitis
Jia-qi BI ; Zhao WANG ; Bing-kun WANG ; Chun-yan SUN ; Ya SUN ; Xiao-tong CUI ; Xin PANG ; Xiao-yu WANG ; Jie-qiong WANG
Chinese Pharmacological Bulletin 2025;41(6):1148-1157
Aim To study the mechanism of adipose mesenchymal stem cell exosomes(ASC-exo)inhibition of fluorescein isothiocyanate(FITC)-induced atopic dermatitis(AD).Methods The mouse age,extrac-tion method,and the concentration of a solution of typeⅠ collagen enzyme and other conditions were compared to study the effects on the morphology and quantity of adipose mesenchymal stem cells(ASCs)after extrac-ted.FITC-induced mouse model in vivo was estab-lished and different doses of ASC-exo were given to measure ear thickness,ear weight and ear scratching times of mice.HE staining was used to observe the pathological changes of ear tissue of mice.The non-toxicity of ASC-exo was detected.IgE,IL-5,IL-13 and other cytokines were detected by ELISA.The gene ex-pressions of TSLP,IL-33,occludin,Claudin-1(CLDN-1)and E-cadherin were detected by RT-qPCR.The protein expression was detected by immunohistochemis-try.Results An efficient method for extracting ASCs was established.Compared with the blank group,mice in the model group showed obvious AD symptoms.Compared with the model group,ASC-exo administra-tion group significantly reduced the number of ear scratches,epidermal thickening,inflammatory cell infil-tration and the secretion of Th2 cytokines IL-5 and IL-13.Meanwhile,ASC-exo administration group signifi-cantly increased the expression of structural proteins CLDN-1 and occludin in epithelial cells and decreased the expression of TSLP and IL-33.Conclusions ASC-exo can significantly improve Th2 skin inflamma-tion in AD mice,and its mechanism may be through in-creasing the expression of tight junction proteins and adhesion link protein in epithelial cells,repairing the skin barrier,and inhibiting the key promoters of allergy TSLP and IL-33.
6.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
7.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
8.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
9.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
10.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]

Result Analysis
Print
Save
E-mail