1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Coronary artery perforation after using shockwave balloon during percutaneous coronary intervention treatment:a case report
Chen-Ji XU ; Fei LI ; Fa ZHENG ; Bin ZHANG ; Feng-Xia QU ; Jian-Meng WANG ; Ya-Qun ZHOU ; Xian-Liang LI ; Song-Tao WANG ; Yan SHAO ; Chang-Hong LU
Chinese Journal of Interventional Cardiology 2024;32(7):405-408
Coronary perforation is when a contrast agent or blood flows outside a blood vessel through a tear in a coronary artery.In this case,we reported a case of percutaneous coronary intervention for coronary calcified lesions,which led to iatrogenic coronary perforation and cardiac tamponade after the use of Shockwave balloon to treat intracoronary calcified nodules,and the management of PCI-related CAP was systematically reviewed through the literature.
7.Genetic Mutation Profile and Risk Stratification of Cytogenetically Normal Acute Myeloid Leukemia with CEBPA-bZIP Mutations Based on Multi-Gene Sequencing
Lei-Ming CAO ; Ming-Yue LIAO ; Ya-Lan ZHOU ; Hao JIANG ; Qian JIANG ; Ying-Jun CHANG ; Lan-Ping XU ; Xiao-Hui ZHANG ; Xiao-Jun HUANG ; Guo-Rui RUAN
Journal of Experimental Hematology 2024;32(6):1631-1637
Objective:To evaluate the gene mutation profile and prognostic significance of adult cytogenetically normal acute myeloid leukemia (CN-AML) with CEBPA-bZIP mutation. Methods:Targeted sequencing was implemented on the diagnostic bone marrow DNA samples of 141 adult CN-AML subjects with CEBPA-bZIP mutation. The nomogram model for leukemia-free survival (LFS) rate was generated by combining genetic abnormalities and clinical data. Risk stratification was conducted based on prognostic variables and the effect of risk-adjusted consolidation therapy was investigated by Kaplan-Meier method. Results:Four variables were finally included in our nomogram model after multivariate Cox analysis,and an equation for risk score calculation was obtained,risk score=1.3002×white blood cell (WBC) (≥18.77×109/L)+1.4065×CSF3R mutation positive+2.6489×KMT2A mutation positive+1.0128×DNA methylation-related genes mutation positive. According to the nomogram model,patients were further divided into low-risk group (score=0,n=46) and high-risk group (score>0,n=95). Prognostic analysis showed that the 5-year LFS rate,5-year overall survival (OS) rate,and 5-year cumulative incidence of relapse (CIR) of patients who received allogeneic hematopoietic stem cell transplantation (allo-HSCT) in the high-risk group were 93.5%,97.1%,and 3.5%,while those in patients who received maintenance chemotherapy were 32.9%,70.5%,and 63.4%,respectively. The differences were statistically significant (all P<0.05). Allo-HSCT could significantly improve the prognosis of patients in high-risk group. However,no corresponding benefit was observed in the low-risk group. Conclusion:Adult CN-AML with CEBPA-bZIP mutation has a complex co-mutation pattern. The nomogram model based on mutations of CFS3R,KMT2A and DNA methylation-related genes together with WBC count can further divide this subset of patients into a relatively low-risk group and a relatively high-risk group. For individuals in the high-risk group,allo-HSCT is proposed as post-remission therapy. The above data will benefit the prognosis estimation and treatment decision for adult CN-AML with CEBPA-bZIP mutation.
8.Relationship between hypertension history and long-term coronary adverse prognosis in patients with acute coronary syndrome
Meng-Ya DONG ; Chen-Bo XU ; Juan ZHOU ; Zu-Yi YUAN
Chinese Journal of cardiovascular Rehabilitation Medicine 2024;33(3):261-264
Objective:To analyze the relationship between hypertension history and long-term coronary adverse prognosis in patients with acute coronary syndrome(ACS).Methods:The study was a retrospective,single-center,observational research.A total of 385 patients,who admitted in Department of Cardiology of First Affiliated Hos-pital of Xi'an Jiaotong University from January 2013 to February 2014,diagnosed as ACS and received coronary an-giography(CAG),were continuously collected.Ischemic events were defined as revascularization,in-stent throm-bosis,in-stent restenosis and active angina.Kaplan-Meier survival curve and Cox regression analysis were used to determine the relationship between hypertension history and long-term coronary adverse prognosis in ACS pa-tients.Results:The 385 patients were divided into hypertension history ≤1 year group(n=201)and hypertension history>1 year group(n=184)according to the median of hypertension history.After follow-up of 2.6(2.3,2.8)years,39 cases(19.4%)and 46 cases(25.0%)suffered from ischemic events in hypertension history ≤1 year group and hypertension history>1 year group respectively.Kaplan-Meier survival curve analysis revealed that the incidence rate of ischemic events in hypertension history>1 year group was significantly higher than that of hyper-tension history ≤1 year group(x2=4.675,P=0.031).After adjusting possible confounding factors,multivariable Cox regression analysis indicated that hypertension history remained an independent risk factor of ischemic events in ACS patients(HR=1.033,95%CI 1.008-1.057,P=0.008).Conclusion:Hypertension history is an independent risk factor for long-term ischemic events in patients with acute coronary syndrome.And the risk of ischemic e-vents is significantly increasing with the longer hypertension history.
9.Design,numerical simulation and experimental study of novel oxygenator
Ming-Hao YUE ; Shi-Yao ZHANG ; Ji-Nian LI ; Hui-Chao LIU ; Zi-Hua SU ; Ya-Wei WANG ; Zeng-Sheng CHEN ; Shi-Hang LIN ; Jin-Yu LI ; Ya-Ke CHENG ; Yong-Fei HU ; Cun-Ding JIA ; Ming-Zhou XU
Chinese Medical Equipment Journal 2024;45(3):23-28
Objective To design a novel oxygenator to solve the existing problems of extracorporeal membrane oxygenation(ECMO)machine in high transmembrane pressure difference,low efficiency of blood oxygen exchange and susceptibility to thrombosis.Methods The main body of the oxygenator vascular access flow field was gifted with a flat cylindrical shape.The topology of the vascular access was modeled in three dimensions,and the whole flow field was cut into a blood inlet section,an inlet buffer,a heat exchange zone,a blood oxygen exchange zone,an outlet buffer and a blood outlet section.The oxygenator was compared with Quadrox oxygenator by means of ANSYS FLUENT-based simulation and prototype experiments.Results Simulation calculations showed the oxygenator designed was comparable to the clinically used ones in general,and gained advantages in transmembrane pressure difference,blood oxygen exchange and flow uniformity.Experimental results indicated that the oxygenator behaved better than Quadrox oxygenator in transmembrane pressure difference and blood oxygen exchange.Conclusion The oxygenator has advantages in transmem-brane pressure difference,temperature change,blood oxygen ex-change and low probability of thrombosis.[Chinese Medical Equipment Journal,2024,45(3):23-28]
10.A new suberin from roots of Ephedra sinica Stapf
Bo-wen ZHANG ; Meng LI ; Xiao-lan WANG ; Ying YANG ; Shi-qi ZHOU ; Si-qi TAO ; Meng YANG ; Deng-hui ZHU ; Ya-tong XU ; Wei-sheng FENG ; Xiao-ke ZHENG