1.Analysis of the Current Situation of Multi-Hospital Construction in Foreign Countries and Its Enlightenment to the Construction of"One Hospital with Multiple Campuses"in China
Zewen XU ; Ruxu GE ; Ya ZHANG ; Haiyan LI ; Na ZHAO ; Yanli ZHANG ; Qi JING ; Wengui ZHENG
Chinese Hospital Management 2025;45(8):24-29
Objective To explore the current situation and experience of the development of multi-hospital areas in foreign medical institutions,and to analyze its enlightenment to the construction of"one hospital with multiple campuses"in public hospitals in China.Methods Through the combing of relevant literature,it systematically analyzes the development status of multi-hospital construction of medical institutions in typical countries such as the United States,the United Kingdom,and Germany,summarizes the relevant experience of different countries,and analyzes the current situation of the construction of"one hospital with multiple campuses"in China's public hospitals.Results At present,the orderly development of multiple hospitals of foreign medical institutions mainly depends on the homogenization of medical care,the scientific management of human resources and the improvement of information construction.China can learn from its experience and technical means to build a development pattern of"one hospital with multiple campuses"suitable for China's national conditions.Conclusion In the future,the construction of"one hospital with multiple campuses"in China's public hospitals should focus on"rationalization of human resource allocation,homogenization of medical service quality,and intelligent information system construction",improve"human resource allocation",establish and improve"information sharing mechanism",differentiate the layout of"hospital functions",and strengthen"quality supervision and patient feedback",aiming to improve the construction effect of"one hospital with multiple campuses"in China's public hospitals.
2.Study of debridement effects of multi shapes of plasma scalpels in explosion injury model
Hong-ye ZHENG ; Yu LI ; Zi-heng XU ; Yu-fan WEI ; Bo-ya ZHANG ; Yan LI ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(2):31-38
Objective To explore the debridement effects of 3 types of plasma scalpels for the animal model of explosion injury,and to compare them with the steel scalpel and high-frequency electrosurgical scalpel.Methods Firstly,blast wounds were constructed in the right inguinal regions of 9 Landrace pigs by high-pressure gas impact combined with preset metal shrapnel.Secondly,debridement was carried out in experimental groups with wide-,arrow-or needle-type plasma scalpel and in control groups with steel and high-frequency electrisurgical scalpel,with the operating temperature and debridement time recorded during the procedure and trauma specimens analyzed pathologically after the debridement;comparisons were performed among the five types of scalpels in terms of debridement effect,and among the four ones in terms of maximum operating temperature and depth of tissue thermal damage under electrocutaneous cutting and electrocoagulation modes with the steel scalpel excluded because it did not generate any heat.GraphPad Prism 9.5.1 software was used for statistical analysis.Results There were no significant differences in debridement effect found between the three plasma scalpels and the steel and high-frequency electrosurgical scalpels(P>0.05).The three types of plasma scalpels had the maximum operating temperature lower significantly than that of the high-frequency electrosurgical scalpel during debridement(P<0.05).Under electrosection and electrocoagulation modes the three plasma scalpels had the depths of tissue thermal damage statistically less than that by the high-frequency electrosurgical scalpel under electrosection and electrocoagulation modes(P<0.05).The depths of tissue thermal damage by the four scalpels under electrocoagulation mode were obviously greater than those under electrosection mode(P<0.05).Conclusion Multi shapes of plasma scalpels behave well in debridement with low operating temperature,little tissue thermal damage and high efficiency for wound protection and the same efficacy with the steel scalpel and high-frequency electrosur-gical scalpel.[Chinese Medical Equipment Journal,2025,46(2):31-38]
3.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]
4.Research of miR-508-3p involvement in ovarian cancer progression by regulating ZEB1
Yu-hong XU ; Shuai-ying ZHU ; Jiang-jing SHAN ; Wei-ping ZHENG ; Hui-ya ZHANG ; Yun-gen WANG
The Chinese Journal of Clinical Pharmacology 2025;41(2):193-197
Objective To investigate the expression of microRNA-508-3p(miR-508-3p)in epithelial ovarian cancer(EOC)tissue,its impact on the migration and invasion of ovarian cancer cells,and its regulatory relationship with zinc-finger E-box-binding homeobox 1(ZEB1).Methods The surgical resection of EOC cancer tissues and paired adjacent normal tissues were collected.SKOV3 cells were divided into the NC mimic group(transfected with NC mimic),miR-508-3p mimic group(transfected with miR-508-3p mimic),si-NC group(transfected with si-NC),si-ZEB1 group(transfected with si-ZEB1)and co-transfection group(co-transfected with si-ZEB1 and miR-508-3p mimic).The mRNA expression levels of miR-508-3p and ZEB1 in EOC cancer tissues,adjacent normal tissues and five groups of cells were measured by real-time quantitative polymerase chain reaction.The Transwell assay was used to detect the cell migration and invasion abilities.Results The relative expression levels of miR-508-3p in EOC tissues and adjacent normal tissues were 0.77±0.36 and 1.07±0.40,the relative expression levels of ZEB1 mRNA in EOC tissues and adjacent normal tissues were 2.10±1.21 and 1.29±0.95,and the differences were statistically significant(all P<0.01).The migration cell number of the NC mimic,miR-508-3p mimic,si-NC,si-ZEB1 and co-transfection groups was 633.00±32.49,319.20±19.89,650.40±25.85,375.00±17.25 and 129.40±17.10;the invasion cell number was 527.20±25.01,288.60±16.68,520.00±25.83,293.40±18.37 and 76.60±8.76;the relative expression levels of miR-508-3p were 1.05±0.37,3.94±1.21,1.01±0.21,1.26±0.34 and 3.40±0.41;the relative expression levels of ZEB1 mRNA were 1.00±0.04,0.58±0.05,1.00±0.08,0.54±0.07 and 0.29±0.03,respectively.The above indicators showed statistically significant differences between the miR-508-3p mimic group and the NC mimic group,between the si-NC group and the co-transfection group(P<0.01,P<0.05).Conclusion MiR-508-3p is lowly expressed in EOC cancer tissue,and it may inhibit the migration and invasion of ovarian cancer cells by targeting ZEB1 expression.
5.Enhanced BBB penetration and microglia-targeting nanomodulator for the two-pronged modulation of chronically activated microglia-mediated neuroinflammation in Alzheimer's disease.
Ya WEI ; Xue XIA ; Xiaorong WANG ; Wenqin YANG ; Siqin HE ; Lulu WANG ; Yongke CHEN ; Yang ZHOU ; Feng CHEN ; Hanmei LI ; Fu PENG ; Guobo LI ; Zheng XU ; Jintao FU ; Huile GAO
Acta Pharmaceutica Sinica B 2025;15(2):1098-1111
Intervention in chronically activated microglia-mediated neuroinflammation is a novel approach to treat Alzheimer's disease (AD). The low permeability of the blood‒brain barrier (BBB) and non-selective distribution in the brain severely restrict AD drugs' disease-modifying efficacy. Here, an immunosuppressant TREM2-lowing antisense oligonucleotides (ASOs) and resveratrol co-loaded cationic liposome is developed as an immune reprogramming nanomodulator modified by acid-cleavable BBB-targeting peptide and microglia-targeting peptide (Res@TcMNP/ASO) for AD management. Res@TcMNP/ASO can enter brain endothelial cells via D-T7 peptides. Then D-T7 undergoes an acid-responsive cleavage, facilitating the escape of Res@MNP/ASO from endo/lysosomes to cross the BBB. The detached Res@MNP/ASO specifically targets M1-phenotype microglia via exposed MG1 peptides to prompt the simultaneous delivery of two drugs into activated microglia. This nanomodulator can not only restore the immune function of microglia through TREM2-lowing ASO but also mitigate the immune stimulation to microglia caused by reactive oxygen species (ROS) through resveratrol, thereby synergistically inhibiting the chronic activation of microglia to alleviate neuroinflammation in AD. Our results indicate that this combination treatment can achieve significant behavioral and cognitive improvements in late APP/PS1 mice.
6.Tanreqing Capsules protect lung and gut of mice infected with influenza virus via "lung-gut axis".
Nai-Fan DUAN ; Yuan-Yuan YU ; Yu-Rong HE ; Feng CHEN ; Lin-Qiong ZHOU ; Ya-Lan LI ; Shi-Qi SUN ; Yan XUE ; Xing ZHANG ; Gui-Hua XU ; Yue-Juan ZHENG ; Wei ZHANG
China Journal of Chinese Materia Medica 2025;50(8):2270-2281
This study aims to explore the mechanism of lung and gut protection by Tanreqing Capsules on the mice infected with influenza virus based on "the lung-gut axis". A total of 110 C57BL/6J mice were randomized into control group, model group, oseltamivir group, and low-and high-dose Tanreqing Capsules groups. Ten mice in each group underwent body weight protection experiments, and the remaining 12 mice underwent experiments for mechanism exploration. Mice were infected with influenza virus A/Puerto Rico/08/1934(PR8) via nasal inhalation for the modeling. The lung tissue was collected on day 3 after gavage, and the lung tissue, colon tissue, and feces were collected on day 7 after gavage for subsequent testing. The results showed that Tanreqing Capsules alleviated the body weight reduction and increased the survival rate caused by PR8 infection. Compared with model group, Tanreqing Capsules can alleviate the lung injury by reducing the lung index, alleviating inflammation and edema in the lung tissue, down-regulating viral gene expression at the late stage of infection, reducing the percentage of neutrophils, and increasing the percentage of T cells. Tanreqing Capsules relieved the gut injury by restoring the colon length, increasing intestinal lumen mucin secretion, alleviating intestinal inflammation, and reducing goblet cell destruction. The gut microbiota analysis showed that Tanreqing Capsules increased species diversity compared with model group. At the phylum level, Tanreqing Capsules significantly increased the abundance of Firmicutes and Actinobacteria, while reducing the abundance of Bacteroidota and Proteobacteria to maintain gut microbiota balance. At the genus level, Tanreqing Capsules significantly increased the abundance of unclassified_f_Lachnospiraceae while reducing the abundance of Bacteroides, Eubacterium, and Phocaeicola to maintain gut microbiota balance. In conclusion, Tanreqing Capsules can alleviate mouse lung and gut injury caused by influenza virus infection and restore the balance of gut microbiota. Treating influenza from the lung and gut can provide new ideas for clinical practice.
Animals
;
Drugs, Chinese Herbal/administration & dosage*
;
Mice
;
Lung/metabolism*
;
Mice, Inbred C57BL
;
Capsules
;
Orthomyxoviridae Infections/virology*
;
Gastrointestinal Microbiome/drug effects*
;
Male
;
Humans
;
Female
;
Influenza A virus/physiology*
;
Influenza, Human/virology*
7.A quality improvement study on improving the follow-up rate of preterm infants after discharge.
He-Sheng CHANG ; Xue YANG ; Jun JU ; Wen-Ya XU ; Di WU ; Xiao-Man WAN ; Zheng-Hong LI
Chinese Journal of Contemporary Pediatrics 2025;27(2):148-154
OBJECTIVES:
To explore the measures to improve the follow-up rate of preterm infants after discharge, and to evaluate the effectiveness of these measures using quality improvement methodology.
METHODS:
The follow-up status of preterm infants discharged from March to May 2017 was used as the baseline before quality improvement, and a specific quality improvement goal for the follow-up rate was proposed. The Pareto chart was used to analyze the causes of follow-up failure, and a key driver diagram was constructed based on the links involved in improving follow-up rate. The causes of failure were analyzed to determine the key links and intervention measures for quality improvement, and the follow-up rate was monitored weekly using a control chart until the quality improvement goal was achieved.
RESULTS:
The follow-up rate of preterm infants after discharge was 57.92% (117/202) at baseline before quality improvement, and the quality improvement goal was set to increase the follow-up rate of preterm infants from baseline to more than 80% within 12 months. The Pareto chart analysis showed that the main causes of follow-up failure were deficiencies in follow-up file management and irregular follow-up times (33.70%, 31/92), insufficient follow-up education and poor communication (25.00%, 23/92), and the inability to meet the diverse needs of parents (18.48%, 17/92). Based on the key links for quality improvement and the main causes of follow-up failure, the following intervention measures were adopted: (1) strengthen follow-up publicity and education; (2) build a follow-up team; and (3) establish a follow-up platform and system. The control chart indicated that with the implementation of the above intervention measures, the weekly follow-up rate increased to 74.09% (306/413) in July 2017 and 83.09% (511/615) in December 2017, finally achieving the quality improvement goal. During the COVID-19 pandemic, the follow-up rate of preterm infants fluctuated between 23.54% (460/1 954) and 70.97% (1 931/2 721), and subsequently, it returned to pre-pandemic levels starting in February 2023.
CONCLUSIONS
The application of quality improvement methodology can help to formulate intervention measures based on the main causes of follow-up failure, thereby improving the follow-up rate of preterm infants after discharge. This quality improvement method is feasible and practical and thus holds promise for clinical application.
Humans
;
Quality Improvement
;
Infant, Premature
;
Infant, Newborn
;
Patient Discharge
;
Follow-Up Studies
;
Female
;
Male
8.Comparison of clinical characteristics between primary bilateral macronodular adrenal hyperplasia and adrenal cortisol-producing adenoma
Bing LI ; Ming-Xiu YANG ; Huai-Jin XU ; Jing-Xuan WANG ; Qing-Zheng WU ; Ya-Jing WANG ; Yi-Jun LI ; Kang CHEN ; Yu CHENG ; Qi NI ; Ya-Qi YIN ; Li ZANG ; Qing-Hua GUO ; Jian-Ming BA ; Wei-Jun GU ; Jing-Tao DOU ; Zhao-Hui LYU ; Yi-Ming MU
Medical Journal of Chinese People's Liberation Army 2025;50(7):779-785
Objective To comparatively analyze the clinical characteristics of primary bilateral macronodular adrenal hyperplasia(PBMAH)and adrenal cortisol-producing Adenoma(CPA),and enhance the understanding of two diseases.Methods The clinical data of 85 PBMAH patients(PBMAH group)and 195 CPA patients(CPA group)diagnosed at Department of Endocrinology,the First Medical Center of Chinese PLA General Hospital,from September 2014 to August 2024 were retrospectively analyzed.The demographic characteristics,comorbidities,biochemical indicators,adrenocorticotropic hormone-cortisol(ACTH-F)levels,and adrenal imaging features and treatment conditions were compared between the two groups.Results(1)General characteristics:Compared with CPA group,PBMAH group had older age at diagnosis and a higher proportion of male patients.(2)Clinical characteristics:Compared with CPA group,PBMAH group had a longer disease duration,a higher proportion of subclinical Cushing's syndrome(CS),and a higher proportion of hypertension,impaired glucose tolerance/diabetes,bone mass reduction or osteoporosis,with higher serum potassium levels,and the differences were statistically significant(P<0.01).(3)Hormone levels:Both PBMAH and CPA groups showed ACTH-F rhythm disorder,significantly increased cortisol levels and suppressed ACTH.Compared with PBMAH group,CPA group had stronger autonomous cortisol secretion ability,manifested by increased midnight serum cortisol(F0:00),16:00 serum cortisol(F16:00),24-hour urinary free cortisol(24 h UFC)levels and lower 8:00 serum ACTH(ACTH8:00)and 16:00 serum ACTH(ACTH16:00)(P<0.01).After low-dose dexamethasone suppression test(LDDST),CPA group showed lower suppression rates of ACTH and cortisol,and higher proportions of paradoxical elevation in serum cortisol and 24 h UFC compared with PBMAH(P<0.01).Conclusions PBMAH has a longer disease course and higher proportions of comorbid metabolic disorders than CPA,mostly manifested as subclinical Cushing's syndrome.CPA has stronger autonomous cortisol secretion ability,with cortisol less likely to be suppressed after LDDST and more obvious paradoxical elevation of cortisol and 24 h UFC.
9.A case of chronic total occlusion of coronary arteries opened by reverse guidewire technology with ipsilateral brachioradial artery combined approach
Zhao-kun MA ; Cheng-yi XU ; Ya-feng GUO ; Dong YI ; Zheng-le YANG ; Hua YAN
Chinese Journal of Interventional Cardiology 2025;33(10):597-600
Intra-aortic balloon pump(IABP),as the most commonly used percutaneous mechanical circulatory assist device,is routinely implanted through the femoral artery pathway.However,when implantation through the femoral artery pathway is difficult or contraindicated,other pathways including the brachial artery pathway,axillary artery pathway,etc.can be considered.IABP assisted interventional treatment for complex high-risk and indicated patients(CHIP)can reduce the risk of intraoperative complications,stabilize hemodynamics,increase the complete revascularization rate of CHIP,and improve long-term prognosis.The reverse guidewire technique can improve the success rate of percutaneous coronary intervention(PCI)for chronic total occlusion(CTO)of coronary arteries.In clinical practice,the reverse pathway is often chosen in addition to the forward pathway,such as the contralateral radial and brachial artery pathway,femoral artery pathway,etc.This article reports a case of bilateral femoral artery occlusion,in which IABP was implanted through the left brachial artery pathway,and then with the assistance of IABP,the right coronary artery CTO lesion was successfully opened through the right radial artery in the forward direction and the right brachial artery in the reverse direction,with the aim of providing reference for clinical PCI treatment for such special cases.
10.Guide on Methodological Standards in Pharmacoepidemiology(2nd edition)and their series interpretation(10):an overview and case study of quality assessment tools
Qingyong ZHENG ; Caihua XU ; Yongjia ZHOU ; Xiao TANG ; Mengjun ZHANG ; Jinzhi QI ; Ming LIU ; Ya GAO ; Feng SUN ; Jinhui TIAN
Chinese Journal of Pharmacoepidemiology 2025;34(10):1113-1126
Methodological quality assessment is a pivotal link between primary studies and reliable evidence-based practice,and an essential pathway for operationalizing the core principles of the Guide on Methodological Standards in Pharmacoepidemiology(2nd edition).A prevalent challenge in practice,however,is the conflation of appraising methodological robustness(risk of bias assessment)with verifying reporting transparency(adherence to reporting guidelines).This paper systematically addresses this fundamental challenge,beginning with a clear distinction between the essence and boundaries of these two concepts.On this basis,the article provides a comprehensive review of mainstream quality assessment tools,covering the methodological features and evolutionary trajectory of numerous instruments for interventional(e.g.,RoB 2,ROBINS-I),observational(e.g.,NOS,the JBI/SIGN/NIH series),secondary(e.g.,AMSTAR 2),and other specific types of studies such as health economic evaluations.Furthermore,a complete case study is used to illustrate the practical application of the ROBINS-I tool.The paper's central thesis advocates for an"appraisal-informed design"philosophy,urging a conceptual shift from the retrospective critique of existing literature to the prospective quality control of new research by internalizing appraisal standards as design principles,while also exploring the emerging paradigm of artificial intelligence in assisting assessment.This paper provides a comprehensive methodological reference for researchers and practitioners to prudently select appropriate assessment tools and to conduct rigorous critical appraisals of pharmacoepidemiological evidence.

Result Analysis
Print
Save
E-mail