1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Comparison of Blood Oxygen Saturation Detection Methods in Patients with Hyperleukocytic Acute Leukemia
Hui-Xia GUO ; Shu-Ya CAO ; Yi-Juan CHEN ; Qian LI ; Yue WU ; Yu-Xi SHANG ; Li-Ru WANG
Journal of Experimental Hematology 2024;32(4):1026-1031
Objective:To investigate which indicator is more advantageous when using arterial oxygen saturation(SaO2)and fingertip pulse oxygen saturation(SpO2)for blood oxygen detection in patients with hyperleukocytic acute leukemia(HAL).Methods:In this prospective research,the difference between SaO2 and SpO2 of 18 HAL patients(observation group)and 14 patients(control group),as well as the relationship between the difference and white blood cell(WBC)counts were analyzed.Results:SaO2 was lower than SpO2 in the observation group(P<0.05),and SpO2-SaO2 difference was positively correlated with WBC counts(r=0.47).However,there was no statistical difference between SaO2 and SpO2 in the control group.SaO2 and PO2 showed a downward trend with the prolongation of detection time after arterial blood was collected in the observation group,but there was no statistical difference.There was no downward trend of SaO2 and PO2 in the control group.Conclusion:HAL patients have a phenomenon where SaO2 is lower than SpO2,that is pseudohypoxemia,and this phenomenon may be caused by excessive consumption of oxygen by the leukemia cells in vitro.SpO2 can be monitored bedside in real time and is non-invasive,it is a better way to detect the blood oxygen status of HAL patients.
7.In Vitro Amplification of NK Cells from Feeder Layer Cells Expressing IL-21
Zhen-Zhao XU ; Xue-Hua ZHANG ; Ling-Ping ZHAO ; Gao-Hua LI ; Tian-Tian CUI ; Xiao-Ling WANG ; Xuan LI ; Ru-Ge ZANG ; Wen YUE ; Ya-Nan WANG ; Guo-Xin LI ; Jia-Fei XI
Journal of Experimental Hematology 2024;32(5):1578-1584
Objective:To investigate the effect of feeder layer cells expressing interleukin(IL)-21 on the amplification of NK cells in vitro.Methods:The K562 cell line with IL-21 expression on its membrane was constructed by electroporation,and co-cultured with NK cells after inactivation.The proliferation of NK cells was observed.The killing function of the amplified NK cells in vitro was evaluated by the lactate dehydrogenase(LDH)and interferon-γ(IFN-y)release assay.A colorectal cancer xenograft model in NOD/SCID mice was established,and a blank control group,a NK cell group and an amplified NK cell group were set up to detect the tumor killing effect of amplified NK cells in vivo.Results:K562 cells expressing IL-21 on the membrane were successfully constructed by electroporation.After co-culturing with K562 cells expressing IL-21 on the membrane for 17 days,the NK cells increased to 700 times,which showed an enhanced amplification ability compared with control group(P<0.001).In the tumor cell killing experiment in vitro,there was no significant difference in the killing activity on tumor cells between NK cells and amplified NK cells,and there was also no significant difference in mice in vivo.Conclusion:K562 cells expressing IL-21 on the membrane can significantly increase the amplification ability of NK cells in vitro,but do not affect the killing function of NK cells in vitro and in vivo.It can be used for the subsequent large-scale production of NK cells in vitro.
8.Protective effect of Naru-3 on collagen-induced arthritis in rats
Hai-Yue ZHAO ; Xiao-Shan ZHANG ; Sha-Sha DUAN ; Yi-Lu SHI ; Min-Jie ZHANG ; Shu-Rong YUN ; Ya-Xi WANG
Chinese Traditional Patent Medicine 2024;46(6):1842-1849
AIM To investigate the protective effect of Mongolian medicine Naru-3 on rat rheumatoid arthritis(RA)using imaging method.METHODS With the rats divided into the normal group,the model group,the positive medicine group,and the low,medium and high dose Naru-3 groups(0.1,0.2 and 0.4 g/kg),the rat model of collagen-induced arthritis(CIA)was established by immune induction method.After 4 weeks of corresponding drug administration,the rats had their changes of arthritis index(AI)level and body weight observed;their serum levels of VEGF,TNF-α and IL-1 detected by ELISA;their synovial hyperplasia and neovascularization evaluated by high-frequency ultrasound and contrast-enhanced ultrasound(CEUS);their bone destruction of ankle joint evaluated by X-ray and high-resolution micro-CT;and their synovial membrane and expressions of CD31,VEGF,TNF-α and IL-1 β observed by HE and immunohistochemistry.RESULTS Compared with the model group,the Naru-3 groups displayed increased rat weight(P<0.05);no significantly changed AI score(P>0.05);and overally decreased levels of serum VEGF,TNF-α,synovial membrane thickness,blood flow signal by power Doppler imaging(PDI)and contrast intensity revealed,X-ray score,and CD31 expression(P<0.05),in addition to the decreased level of IL-1 and HE score in high-dose group(P<0.05).CONCLUSION Naru-3 is protective to the joint tissue in rat model of RA through alleviating synovitis,bone erosion and delaying the progress of the disease by inhibiting synovial neovascularization and inflammatory cytokines.
9.Clinical characteristics in ocular diseases with CACNA1F genetic variants
Ping WANG ; Li XIE ; Xiaoyun XI ; Yunzhen OU ; Ya PAN ; Dongsheng YANG
Chinese Journal of Ocular Fundus Diseases 2024;40(6):443-448
Objective:To observe the clinical phenotype of patients with CACNA1F gene variant. Methods:A retrospective clinical study. From January 1, 2022 to October 1, 2023, 36 patients with CACNA1F gene mutation-related eye diseases diagnosed by clinical examination and genetic testing in Changsha Aier Eye Hospital and Jinan Purui Eye Hospital were included in the study. All patients underwent best-corrected visual acuity (BCVA), medical optometry, fundus color photography, optical coherence tomography, full-field electroretinography (ERG), nystagmus examination, and genetic whole-exon sequencing. BCVA was performed using log visual acuity charts and converted to (logMAR). The nystagmus examination was performed using a helmet-mounted multifunctional video eye movement recording system. The clinical phenotypic characteristics were observed. Results:At total of 36 patients were male, aged was (6.69±5.26) years. There were 36 cases of myopia (38.89%, 14/36), and the spherical equivalent was (?3.01±4.84) D. There were 14 different genetic variants including 7 cases of pathogenic variants, 20 cases of suspected pathogenic variants and 9 cases of unknown pathogenic variants, respectively. logMAR BCVA was 0.67±0.27; 26 patients had optic nerve atrophy (72.22%, 26/36); 6 had optical nerve hypoplasia (16.67%, 6/36). Fundus pigment dysplasia with mild iris transillumination was found in 4 cases (11.11%, 4/36). There were 5 cases of foveal dysplasia (Thomas grade) 1 (13.89%, 5/36). In full-field ERG examination, the B-wave reduction of the maximum mixed reaction of dark adaptation showed a negative waveform, and the amplitude of the shock potential was seriously reduced. The main phenotypes were residual type (residual dark adaptation 0.01 reaction wave and bright adaptation 3.0 reaction wave, and the response decreased at 30 Hz to a double-peak wide wave), dominant type of bright adaptation decreased (all light adaptation extinguished, all dark adaptation extinguished), and total extinction type (all light adaptation extinguished). Among them, 10 cases presented with residual ERG (27.78%, 10/36), 8 cases with photopic reduced ERG (22.22%, 8/36) and 18 with extinguished ERG (50.00%, 18/36). Low amplitude and high frequency pendulum (PLAHF) nystagmus waverforms were found in 32 cases (88.89%, 32/36), head oscillation in 27 cases (75.00%, 27/36) and chin up abnormal head posture in 26 cases (72.22%, 26/36), respectively.Conclusions:CACNA1F Gene variant eye diseases had diverse clinical phenotype. Clinical phenotype of PLAHF nystagmus is closely related with CACNA1F gene variant eye disease.
10.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.

Result Analysis
Print
Save