1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
3.Temporomandibular joint capsule suspension for neocondyle stability in free fibular flap reconstruction of the mandibular condyle
Shuang BAI ; Yao YU ; Wen-Bo ZHANG ; Ya-Qing MAO ; Yang WANG ; Chi MAO ; Dian-Can WANG ; Xin PENG
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(1):46-53
Objectives:
This study evaluates the efficacy of a new temporomandibular joint (TMJ) capsule suspension technique for stabilizing the TMJ after free fibular flap reconstruction of the mandibular condyle.
Patients and Methods:
Patients undergoing the TMJ capsule suspension technique during free fibular flap reconstruction after mandibulectomy with condylectomy (study group; n=9) were compared with a control group (n=9). Mandibular movement trajectory and surface electromyographic signals of bilateral masseters were recorded. The neocondyle–disc relationship was examined with magnetic resonance imaging (MRI) at 6 months after surgery.
Results:
Maximal mouth opening and bilateral marginal movement distances were comparable between the two groups (P>0.05). The asymmetry index of the condyle path length was significantly higher in controls (P=0.02). Bilateral mouth opening trajectories were symmetric in 7 patients and deviated to the affected side in 2 patients in the study group; they deviated to the affected side in all controls. The mean electromyographic values of the masseter on the affected side in resting, maximum bite, and chewing states were comparable between the two groups (P=0.13, P=0.65, and P=0.82, respectively). On MRI at 6 months, the thicknesses of the anterior, medial, and posterior bands and TMJ disc length were similar on the affected and normal sides in the study group (P=0.57, P=0.13, P=0.48, and P=0.87, respectively).
Conclusion
The proposed TMJ capsule suspension technique could improve postoperative TMJ structure and function after fibular free flap reconstruction following mandibulectomy with condylectomy.
4.Temporomandibular joint capsule suspension for neocondyle stability in free fibular flap reconstruction of the mandibular condyle
Shuang BAI ; Yao YU ; Wen-Bo ZHANG ; Ya-Qing MAO ; Yang WANG ; Chi MAO ; Dian-Can WANG ; Xin PENG
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(1):46-53
Objectives:
This study evaluates the efficacy of a new temporomandibular joint (TMJ) capsule suspension technique for stabilizing the TMJ after free fibular flap reconstruction of the mandibular condyle.
Patients and Methods:
Patients undergoing the TMJ capsule suspension technique during free fibular flap reconstruction after mandibulectomy with condylectomy (study group; n=9) were compared with a control group (n=9). Mandibular movement trajectory and surface electromyographic signals of bilateral masseters were recorded. The neocondyle–disc relationship was examined with magnetic resonance imaging (MRI) at 6 months after surgery.
Results:
Maximal mouth opening and bilateral marginal movement distances were comparable between the two groups (P>0.05). The asymmetry index of the condyle path length was significantly higher in controls (P=0.02). Bilateral mouth opening trajectories were symmetric in 7 patients and deviated to the affected side in 2 patients in the study group; they deviated to the affected side in all controls. The mean electromyographic values of the masseter on the affected side in resting, maximum bite, and chewing states were comparable between the two groups (P=0.13, P=0.65, and P=0.82, respectively). On MRI at 6 months, the thicknesses of the anterior, medial, and posterior bands and TMJ disc length were similar on the affected and normal sides in the study group (P=0.57, P=0.13, P=0.48, and P=0.87, respectively).
Conclusion
The proposed TMJ capsule suspension technique could improve postoperative TMJ structure and function after fibular free flap reconstruction following mandibulectomy with condylectomy.
5.Effect of fasting blood glucose on coronary fractional flow reserve in patients with borderline coronary artery disease
Yi-wen ZHANG ; Ya-dong LIU ; Meng-xiao WANG ; Yi-ru WANG ; Yun-peng YANG ; Yun-fang SU ; Ji-xin ZHI
Chinese Journal of Interventional Cardiology 2025;33(5):272-277
Objective To explore the correlation between fasting blood glucose(FBG)level and fractional flow reserve(FFR)in patients with borderline coronary artery disease,and to clarify its potential influence on FFR measurement.Methods From August 2020 to August 2023,the data of 135 patients with coronary atherosclerotic heart disease who received coronary angiography and FFR evaluation in the Fourth Affiliated Hospital of Harbin Medical University were retrospectively collected.According to the exclusion and inclusion criteria,85 cases of borderline diseased vessels of single coronary artery with stenosis degree of 50%-80%were screened out,and they were divided into FBG≥6.1 mmol/L group(47 cases)and FBG<6.1 mmol/L group(38 cases).The baseline data,angiographic and functional indexes of the two groups were compared,and the correlation between FBG and FFR was analyzed.Results Compared with the FBG<6.1 mmol/L group,the FBG≥6.1 mmol/L group had a higher proportion of FFR negative results(72.3%vs.23.7%,P<0.001),and the FFR measurement values were generally increased[0.84(0.80,0.90)vs.0.75(0.68,0.80),P<0.001],with statistically significant differences.Pearson correlation analysis was performed on all lesions,and FFR>0.80(negative result)was positively correlated with FBG≥6.1 mmol/L(r=0.484,P<0.001).Conclusions Among the patients with borderline coronary artery disease(50%-80%stenosis)included in this study,FBG≥6.1 mmol/L is significantly correlated with FFR>0.80.For patients with borderline coronary lesions with elevated FBG,the influence of blood glucose factors should be carefully considered in clinical interpretation of FFR results.
6.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
7.Analysis of dosimetric verification results of intensity-modulated radiotherapy for breast cancer based on EPID fraction images
Xiao-hui WU ; Ya-zheng CHEN ; Zu-wen YAO ; Rui LIU ; Yang LIU ; Xiao-hua WANG
Chinese Medical Equipment Journal 2025;46(6):54-58
Objective To investigate the stability and reproducibility of the treatment fractions during the intensity-modulated radiotherapy(IMRT)for breast cancer and the effect of respiratory motion on the dose irradiation of breast cancer radiotherapy by comparing the results of breast cancer dosimetric verification based on fractionated images by an electronic portal imaging device(EPID).Methods A total of 28 IMRT patients admitted to some hospital from January to June 2023 were grouped according to the pathological results and effects of respiratory motion on the accuracy of radiotherapy during clinical treatment,including 14 cases in a breast group and 14 cases in a non-breast group with 8 ones of head and neck tumors,5 ones of esophageal cancer and 1 case of cervical cancer.All the patients underwent a scan with cone beam computed tomography(CBCT)before the first radiotherapy,and image registration was carried out with a positioning CT.An EPID was used to acquire transmission dose images of 10 fractions of radiotherapy,and γ analysis was performed using the RIT 113 QA software to compare the images of the subsequent 9 fractions with those of the first fraction,with the images of the first fraction of radiotherapy as the baseline values.Absolute maximum dose normalization was implemented under the condition of 10%dose assessment threshold,and the γ-pass rates under the 3 criteria of 2%/2 mm,3%/2 mm and 3%/3 mm were counted separately.The fraction dose verification results of the 28 patients were divided into 3 treatment phases of 2-4 times(T1),5-7 times(T2)and 8-10 times(T3)to analyze the stability of dose irradiation during the radiotherapy.SPSS 22.0 software was used for statistical analysis.Results Under the condition of 10%dose assessment threshold,the breast and non-breast groups had the γ-pass rates being(95.80±2.65)%and(94.60±6.59)%under the 2%/2 mm criterion and(98.46±1.31)%and(97.50±3.30)%under the 3%/2 mm criterion respectively,and the differences were statistically significant(all P<0.05).Under the assessment criteria of 2%/2 mm,3%/2 mm and 3%/3 mm,the breast group had the γ-pass rates of fractions of treatment significantly lower than those of the non-breast group(all P<0.05),while the γ-pass rates showed no significant differences at T1,T2 and T3 treatment phases(all P>0.05).Conclusion EPID fraction images contribute to evaluating IMRT accuracy effectively.IMRT has high stability and reproducibility during the treatment cycle,while respiration may result in dose deviation during the fraction radiotherapy for breast cancer,and optical surface tracking technology or active breathing control technology is suggested to be involved in to relieve dose deviation.[Chinese Medical Equipment Journal,2025,46(6):54-58]
8.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]
9.Repair effects of tauroursodeoxycholic acid in combination use with bone marrow mesenchymal stem cells transplantation on a rat model of spinal cord injury
Ya-qian WEN ; Chao-lun LIANG ; Kun-rui ZHENG ; Dian-weng XIE ; Hai-mei YANG ; Meng-di ZOU ; Da GUO ; Xing LI
Chinese Traditional Patent Medicine 2025;47(1):66-72
AIM To investigate the repair effects of tauroursodeoxycholic acid(TUDCA)combined with bone marrow mesenchymal stem cells(BMSCs)transplantation on spinal cord injury(SCI)in rats.METHODS The rats were randomly divided into the sham operation group,the model group,the TUDCA group,the BMSCs transplantation group and the combination therapy of TUDCA and BMSCs transplantation group,with the SCI rat model established by Allen's method.The next day after modeling,the rats of TUDCA and combination therapy groups were given 200 mg/kg TUDCA by gavage.On the 3rd day after modeling,rats in BMSCs transplantation group and combination therapy group were injected with 1 mL tuned bone marrow BMSCs(the 3rd generation,1× 106/mL)via tail vein.Rats in the sham operation group and the model group were given gastric perfusion of normal saline and injection of 1 mL PBS through tail vein.On the 3rd,7th and 14th day after modeling,the rats had their motor function of hind limbs observed and BBB score determined.After the corresponding drug administration,the rats had their movement track of hind limbs recorded by footprint experiment;their the protein expressions of IL-6,IL-10,Arg-1,PI3K and Akt in spinal cord tissue detected by Western blot;their pathological changes of spinal cord tissue observed by HE staining and Nissl staining;and their expressions of MAP2,GAP43 and GFAP detected by immunofluorescence staining.RESULTS Compared with the model group,the groups intervened with TUDCA,or BMSCs transplantation,or combination therapy shared improved hind limb function and spinal cord histomorphology(P<0.05);increased fluorescence intensity of MAP2 and GAP43,and protein expressions of IL-10,Arg-1,p-PI3K and p-Akt(P<0.05);decreased fluorescence intensity of GFAP and IL-6 protein expressions(P<0.05);among which the combination therapy group took the lead(P<0.05).CONCLUSION The combination therapy of TUDCA and BMSCs transplantation may restore the function of the rat model of SCI by reducing inflammatory reaction,alleviating secondary injury,and promoting axon and myelin regeneration via PI3K/Akt signaling pathway.
10.Bone Age Estimation of Chinese Han Adolescents's and Children's Elbow Joint X-rays Based on Multiple Deep Convolutional Neural Network Models
Dan-Yang LI ; Hui-Ming ZHOU ; Lei WAN ; Tai-Ang LIU ; Yuan-Zhe LI ; Mao-Wen WANG ; Ya-Hui WANG
Journal of Forensic Medicine 2025;41(1):48-58
Objective To explore a deep learning-based automatic bone age estimation model for elbow joint X-ray images of Chinese Han adolescents and children and evaluate its performance.Methods A total of 943(517 males and 426 females)elbow joint frontal view X-ray images of Chinese Han ado-lescents and children aged 6.00 to<16.00 years were collected from East,South,Central and North-west China.Three experimental schemes were adopted for bone age estimation.Scheme 1:Directly in-put preprocessed images into the regression model;Scheme 2:Train a segmentation network using"key elbow joint bone annotations"as labels,then input segmented images into the regression model;Scheme 3:Train a segmentation network using"full elbow joint bone annotations"as labels,then in-put segmented images into the regression model.For segmentation,the optimal model was selected from U-Net,UNet++and TransUNet.For regression,VGG16,VGG19,InceptionV2,InceptionV3,ResNet34,ResNet50,ResNet101 and DenseNet121 models were selected for bone age estimation.The dataset was randomly split into 80%(754 samples)for training and validation for model fitting and hyperparameter tuning,and 20%(189 samples)as an internal test set to test the performance of the trained model.An additional 104 elbow joint X-ray images from the same demographic and age group were col-lected and used as an external test set.Model performance was evaluated by comparing the mean ab-solute error(MAE),root mean square error(RMSE),accuracies within±0.7 years(P±0.7 years)and±1.0 years(P±1.0 years)between the estimated age and the actual age,and by drawing radar charts,scat-ter plots,and heatmaps.Results When segmented with Scheme 3,the UNet++model achieved good segmentation performance with a segmentation loss of 0.000 4 and an accuracy of 93.8%at a learning rate of 0.000 1.In the internal test set,the DenseNet121 model with Scheme 3 yielded the best results with MAE,P±0.7 years and P±1.0 years being 0.83 years,70.03%,and 84.30%,respectively.In the external test set,the DenseNet121 model with Scheme 3 also performed best,with an average MAE of 0.89 years and an average RMSE of 1.00 years.Conclusion When performing automatic bone age estima-tion using elbow joint X-ray images in Chinese Han adolescents and children,it is recommended to use the UNet++model for segmentation.The DenseNet121 model with Scheme 3 achieves optimal per-formance.Using segmentation networks,especially that trained with annotation areas encompassing the full elbow joint including the distal humerus,proximal radius,and proximal ulna,can improve the ac-curacy of bone age estimation based on elbow joint X-ray images.

Result Analysis
Print
Save
E-mail