1.Safety evaluation of new drugs of traditional Chinese medicine based on human use experience.
Zhong-Qi YANG ; Ya-Qin TANG ; Hui-Min TANG ; Yan LING ; Yan-Ping DU
China Journal of Chinese Materia Medica 2025;50(3):812-816
Because of the unclear active substances, metabolic pathways, and targets of new drugs of traditional Chinese medicine(TCM), non-clinical safety evaluation often fails to accurately locate the target organs and tissue exposed to medicinal toxicity. The human use experience(HUE) contains important safety information of TCM, while the clinical safety data in the past HUE are few and have not been effectively applied. Standardized prospective HUE studies should be carried out to collect the clinical safety data, in which appropriate physical and chemical indicators(including blood, urine, and stool routine), liver biochemical indicators, kidney biochemical indicators, and cardiovascular biochemical indicators should be selected for safety evaluation, and the detection time point and sample size should be rationally designed. Importance should be attached to the observation of symptoms and signs of adverse events/reactions in patients as well as the safety information of special groups such as the elderly, children, and pregnant women. The adverse events of TCM should be observed, judged, and treated according to the theory and the diagnosis and treatment mode of TCM. The clinical safety information about the HUE should be comprehensively collected for new drugs of TCM to make up for the lack of extrapolation of toxicological test results to humans. The unique advantages of clinical origin of new drugs of TCM should be given full play for cross-reference of the results of toxicological research and the conclusions of HUE safety evaluation. In addition, benefit-risk assessment should be conducted based on HUE, and a panoramic safety evaluation system characterized by macro and micro combination and in line with the characteristics of TCM should be established to improve the success rate in the research and development of new drugs of TCM.
Humans
;
Drugs, Chinese Herbal/adverse effects*
;
Medicine, Chinese Traditional/adverse effects*
;
Drug-Related Side Effects and Adverse Reactions
;
Female
2.Association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty.
Hong-Ru ZHANG ; Ya XIAO ; Shu-Qin JIANG ; Jun SUN ; Wen-Hui SHI ; Jin-Bo LI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(4):404-409
OBJECTIVES:
To investigate the association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty (ICPP).
METHODS:
A retrospective study was conducted involving 61 girls diagnosed with ICPP who visited the pediatric growth and development clinic of the Third Affiliated Hospital of Zhengzhou University between January 2022 and September 2024, designated as the ICPP group, and 61 normally developing girls as the control group. The differences in insulin resistance index (homeostasis model assessment of insulin resistance, HOMA-IR), uterine volume, and other indicators between the two groups were compared, and the relationship between insulin resistance and uterine volume in these girls was analyzed.
RESULTS:
The uterine volume and HOMA-IR level in the ICPP group were significantly higher than those in the control group (P<0.05). Correlation analysis revealed that there was a positive correlation between HOMA-IR level and uterine volume in the ICPP group (rs=0.643, P<0.001). Multiple linear regression analysis indicated that as HOMA-IR increased,uterine volume in the girls tended to increase (P<0.05).
CONCLUSIONS
There is an association between insulin resistance and uterine volume in girls with ICPP, and as HOMA-IR increases, uterine volume in the girls also increases.
Humans
;
Female
;
Insulin Resistance
;
Puberty, Precocious/metabolism*
;
Uterus/pathology*
;
Child
;
Retrospective Studies
;
Organ Size
;
Linear Models
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Association between insulin resistance and idiopathic central precocious puberty in girls and the diagnostic value of insulin resistance
Jin-Bo LI ; Ya XIAO ; Shu-Qin JIANG ; Xiang-Yang LUO ; Hong-Ru ZHANG ; Jun SUN ; Wen-Hui SHI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(12):1487-1492
Objective To explore the relationship between insulin resistance and idiopathic central precocious puberty(ICPP)in girls and the diagnostic value of insulin resistance.Methods Clinical data of 245 girls aged 4 to 7.5 years with low luteinizing hormone(LH)levels(0.2-0.83 IU/L),normal body weight(body mass index standard deviation score between-2 and+2),and early breast development who visited the Department of Pediatric Endocrinology,Henan Provincial Maternal and Child Health Hospital from January 2022 to March 2025 were retrospectively analyzed.According to the Expert Consensus on the Diagnosis and Treatment of Central Precocious Puberty(2022),patients were assigned to an ICPP group(n=123)or a control group(n=122).Correlations between the homeostasis model assessment of insulin resistance(HOMA-IR)and selected indices were assessed.Multivariable logistic regression was used to evaluate the association between HOMA-IR and ICPP,and the diagnostic performance of various indices for ICPP was evaluated.Results HOMA-IR was higher in the ICPP group than in the control group(P<0.001)and was positively correlated with LH peak(rs=0.467,P<0.05)and the LH peak/FSH peak ratio(rs=0.444,P<0.05).The multivariable logistic regression model including age,BMI,and basal LH showed that HOMA-IR was closely associated with ICPP(OR=2.756,95%CI:1.940-3.913).Receiver operating characteristic curve analysis showed that the areas under the curve for basal LH,HOMA-IR,and their combination in diagnosing ICPP were 0.735,0.735,and 0.805,respectively(P<0.05),and the combined model had a greater area under the curve than either basal LH or HOMA-IR alone(both P<0.05).Conclusions HOMA-IR is closely associated with ICPP in girls with low LH and normal body weight,and combining HOMA-IR with basal LH improves early identification and diagnostic efficiency in this population.
9.Quality evaluation of Rubi Fructus based on UPLC-Q-TOF-MS/MS,HPLC fingerprints and content determination
Shu-wan LI ; Yang-zhen LIAO ; Long-fei WANG ; Ya-qin ZHAO ; Jia-he FAN ; Yuan WEI ; Zhen OUYANG
Chinese Traditional Patent Medicine 2025;47(4):1077-1084
AIM To evaluate the quality of Rubi Fructus.METHODS UPLC-Q-TOF-MS/MS was adopted in the component identification,after which the HPLC fingerprints were established,cluster analysis,principal component analysis and orthogonal partial least squares discriminant analysis were used for chemical pattern recognition.and the contents of chlorogenic acid,ferulic acid,ellagic acid,isoquercitrin,kaempferol-3-O-rutinoside,astragalin,tiliroside quercetin,kaempferol were determined.RESULTS Total 34 constituents were identified.There were 19 common peaks in the fingerprints for 31 batches of medicinal materials with the similarities of more than 0.8.Wild varieties and cultivated varieties,and medicinal materials from different producing areas could be distinguished;4 principal components demonstrated the accumulative variance contribution rate of 84.142%;8 differential components were screened,2 of which were ellagic acid and astragalin.Ellagic acid and astragalin displayed higher contents in the wild varieties than those in the cultivated varieties(P<0.05,P<0.01).CONCLUSION UPLC-Q-TOF-MS/MS,HPLC fingerprints combined with content determination can be used for the quality control of Rubi Fructus.
10.Present situation of sensors applied to monitoring of spinal morphology and motion
Shi-yu ZHOU ; Ya-qin LI ; Yang-xi HUANG ; Xiao CHEN ; Jing WANG ; Zhi-min LIANG ; Yu-chen GUO ; Xue YANG ; Ling-li LI
Chinese Medical Equipment Journal 2025;46(6):105-110
The application of sensors to the monitoring of spinal morphology and motion was reviewed in terms of the research object and monitoring index.The present situation of the application of sensors was introduced,such as inertial sensor,stretchable strain sensor and electromagnetic sensor.The deficiencies of sensors applied to the monitoring of spinal morphology and motion were analyzed,and the future directions of the application were pointed out.[Chinese Medical Equipment Journal,2025,46(6):105-110]

Result Analysis
Print
Save
E-mail