1.Applications of Lactoferrin and Its Nanoparticles in Cancer Therapy
Wen-Tian YUE ; Shu-Rong HE ; Qin AN ; Yun-Xia ZOU ; Wen-Wen DONG ; Qing-Yong MENG ; Ya-Li ZHANG
Progress in Biochemistry and Biophysics 2026;53(2):342-355
Cancer remains a leading cause of global mortality, necessitating the development of advanced therapeutic strategies with enhanced efficacy and reduced systemic toxicity. Among promising bioactive agents, lactoferrin (LF)—a multifunctional iron-binding glycoprotein abundantly found in mammalian milk and exocrine secretions—has garnered significant interest for its potent and multifaceted anti-cancer properties. This review provides a comprehensive analysis of the current understanding of LF’s role in oncology, encompassing its structural biology, diverse mechanisms of action, and groundbreaking advancements in its application through nano-engineering. LF exerts anti-tumor effects through multiple pathways, including extracellular action, intracellular action, and immune regulation. It demonstrates a remarkable affinity for cancer cell membranes, binding to overexpressed anionic components such as glycosaminoglycans and sialic acids, as well as to specific receptors including the low-density lipoprotein receptor-related protein-1 (LRP-1). This selective binding facilitates targeted uptake. Upon internalization, LF orchestrates a direct assault by inducing cell-cycle arrest in phases such as G0/G1 or S phase through the modulation of key regulators including cyclins, CDKs, and p53. Furthermore, it promotes programmed cell death via apoptotic pathways, involving caspase activation and downregulation of anti-apoptotic proteins such as survivin. A more recently elucidated mechanism is the induction of ferroptosis, an iron-dependent form of cell death characterized by overwhelming lipid peroxidation. Beyond direct cytotoxicity, LF acts as a potent immunomodulator. It enhances natural killer (NK) cell activity, modulates T-lymphocyte populations, and crucially reprograms tumor-associated macrophages (TAMs) from a pro-tumor M2 state to an anti-tumor M1 state, thereby reversing the immunosuppressive tumor microenvironment (TME). The translation of LF’s potential has been significantly accelerated by nanotechnology. The inherent biocompatibility and natural tumor-targeting capabilities of LF make it an ideal platform for sophisticated drug-delivery systems. This review details various fabrication strategies for LF-based nanoparticles (NPs), including self-assembly, sol-in-oil emulsion, and electrostatic nanocomplexes, among others. Research demonstrates that nano-formulations not only protect LF from degradation but also enhance its bioactivity and anti-cancer potency. More importantly, LF NPs serve as versatile carriers for a wide array of therapeutic agents, including conventional chemotherapeutics, natural compounds, and imaging agents. These engineered systems enable synergistic therapy and facilitate site-specific delivery. Notably, the ability of LF to bind to receptors on the blood-brain barrier (BBB) has been leveraged to develop nano-systems for glioblastoma treatment. Other innovative designs utilize LF to modulate the TME—for instance, by alleviating tumor hypoxia to sensitize cells to radiotherapy and chemotherapy. Despite compelling pre-clinical evidence, the clinical translation of LF and its nano-formulations remains nascent. While early-phase trials have established a favorable safety profile for recombinant human LF, larger Phase III studies have yielded mixed results, underscoring the complexity of its action in humans. Key challenges include enhancing drug targeting, optimizing loading efficiency, ensuring batch-to-batch reproducibility, and achieving deep tumor penetration. Future research must focus on the rational design of next-generation LF-NPs. This entails developing standardized manufacturing protocols, engineering “smart” stimuli-responsive systems for targeted drug release in the TME, and constructing multi-targeting platforms. A concerted interdisciplinary effort is paramount to bridge the gap between bench and bedside. In conclusion, LF, particularly in its nano-engineered forms, represents a highly promising and versatile agent in the oncological arsenal, holding immense potential for precise and effective cancer therapy.
2.Applications of Lactoferrin and Its Nanoparticles in Cancer Therapy
Wen-Tian YUE ; Shu-Rong HE ; Qin AN ; Yun-Xia ZOU ; Wen-Wen DONG ; Qing-Yong MENG ; Ya-Li ZHANG
Progress in Biochemistry and Biophysics 2026;53(2):342-355
Cancer remains a leading cause of global mortality, necessitating the development of advanced therapeutic strategies with enhanced efficacy and reduced systemic toxicity. Among promising bioactive agents, lactoferrin (LF)—a multifunctional iron-binding glycoprotein abundantly found in mammalian milk and exocrine secretions—has garnered significant interest for its potent and multifaceted anti-cancer properties. This review provides a comprehensive analysis of the current understanding of LF’s role in oncology, encompassing its structural biology, diverse mechanisms of action, and groundbreaking advancements in its application through nano-engineering. LF exerts anti-tumor effects through multiple pathways, including extracellular action, intracellular action, and immune regulation. It demonstrates a remarkable affinity for cancer cell membranes, binding to overexpressed anionic components such as glycosaminoglycans and sialic acids, as well as to specific receptors including the low-density lipoprotein receptor-related protein-1 (LRP-1). This selective binding facilitates targeted uptake. Upon internalization, LF orchestrates a direct assault by inducing cell-cycle arrest in phases such as G0/G1 or S phase through the modulation of key regulators including cyclins, CDKs, and p53. Furthermore, it promotes programmed cell death via apoptotic pathways, involving caspase activation and downregulation of anti-apoptotic proteins such as survivin. A more recently elucidated mechanism is the induction of ferroptosis, an iron-dependent form of cell death characterized by overwhelming lipid peroxidation. Beyond direct cytotoxicity, LF acts as a potent immunomodulator. It enhances natural killer (NK) cell activity, modulates T-lymphocyte populations, and crucially reprograms tumor-associated macrophages (TAMs) from a pro-tumor M2 state to an anti-tumor M1 state, thereby reversing the immunosuppressive tumor microenvironment (TME). The translation of LF’s potential has been significantly accelerated by nanotechnology. The inherent biocompatibility and natural tumor-targeting capabilities of LF make it an ideal platform for sophisticated drug-delivery systems. This review details various fabrication strategies for LF-based nanoparticles (NPs), including self-assembly, sol-in-oil emulsion, and electrostatic nanocomplexes, among others. Research demonstrates that nano-formulations not only protect LF from degradation but also enhance its bioactivity and anti-cancer potency. More importantly, LF NPs serve as versatile carriers for a wide array of therapeutic agents, including conventional chemotherapeutics, natural compounds, and imaging agents. These engineered systems enable synergistic therapy and facilitate site-specific delivery. Notably, the ability of LF to bind to receptors on the blood-brain barrier (BBB) has been leveraged to develop nano-systems for glioblastoma treatment. Other innovative designs utilize LF to modulate the TME—for instance, by alleviating tumor hypoxia to sensitize cells to radiotherapy and chemotherapy. Despite compelling pre-clinical evidence, the clinical translation of LF and its nano-formulations remains nascent. While early-phase trials have established a favorable safety profile for recombinant human LF, larger Phase III studies have yielded mixed results, underscoring the complexity of its action in humans. Key challenges include enhancing drug targeting, optimizing loading efficiency, ensuring batch-to-batch reproducibility, and achieving deep tumor penetration. Future research must focus on the rational design of next-generation LF-NPs. This entails developing standardized manufacturing protocols, engineering “smart” stimuli-responsive systems for targeted drug release in the TME, and constructing multi-targeting platforms. A concerted interdisciplinary effort is paramount to bridge the gap between bench and bedside. In conclusion, LF, particularly in its nano-engineered forms, represents a highly promising and versatile agent in the oncological arsenal, holding immense potential for precise and effective cancer therapy.
3.Effect of Chaihuang Qingyi Huoxue Granules on multiple organ damage induced by cerulein combined with lipopolysaccharide in mice with severe acute pancreatitis
Jian-Qin LIU ; Hong-Lian WANG ; Li LI ; Zhi LI ; Ya-Li LIU ; Xin ZHOU
Medical Journal of Chinese People's Liberation Army 2025;50(7):876-881
Objective To investigate the effects of Chaihuang Qingyi Huoxue Granules on multiple organ damage induced by caerulein combined with lipopolysaccharide in mice with severe acute pancreatitis(SAP).Methods Twenty-four C57BL/6J mice were randomly divided into three groups:control(n=8),SAP(n=8)and Chaihuang Qingyi Huoxue Granules(CHQY group,n=8).Mice in SAP and CHQY groups were intraperitoneally injected with caerulein(50 μg/kg)at hourly intervals for 7 consecutive times,followed by an immediate intraperitoneal injection of lipopolysaccharide(10 mg/kg).Mice in control group received an equal volume of normal saline.After the successful establishment of the model,CHQY group mice were administered Chaihuang Qingyi Huoxue Granules[3.185 g/(kg·d)]via gavage,while control and SAP group mice received an equal volume of normal saline.Twenty-four hours post-modeling,mice were anesthetized,and serum was collected and separated for analysis of the activities of amylase(AMY),lipase(LPS),aspartate transaminase(AST),alanine transaminase(ALT)and the contents of creatinine(CREA)and urea(UREA)using an automatic biochemical analyzer.Serum levels of interleukin(IL)-1β,IL-6,IL-8,IL-18,and tumor necrosis factor-α(TNF-α)were measured by ELISA.Tissue samples from pancreas,lung,liver,kidney,and small intestine were collected for histopathological examination using hematoxylin-eosin(HE)staining and scored.The expression of nuclear factor-κB p65(NF-κB p65)was detected in all tissues by immunohistochemistry.Results Compared with control group,the activities of AMY,LPS,AST and ALT,and the contents of CREA,UREA,IL-1β,IL-6,IL-8,IL-18,and TNF-α were increased(P<0.05).Pathological injuries in the pancreas,lung,liver,kidney,and small intestine was significant,with increased pathological scores and a higher proportion of NF-κB p65 positive cells(P<0.05).Compared with SAP group,the activities of AMY,LPS,AST,ALT,and the contents of CREA,UREA,IL-1β,IL-6,IL-8,IL-18,and TNF-α in the serum of CHQY group were decreased(P<0.05).Pathological injuries in the pancreas,lung,liver,kidney and small intestine were reduced,with lower pathological scores and a decreased proportion of NF-κB p65 positive cells(P<0.05).Conclusion Chaihuang Qingyi Huoxue Granules have a certain therapeutic effect on SAP model mice,which may be related to reducing inflammation response and improving multiple organ damage such as the pancreas,lung,liver,kidney and small intestine.
4.Effect of dysbindin-1 deletion on exosomes derived from mouse testicular tissue
Shu ZHANG ; Pan-Pan ZHANG ; Xin SUN ; Hai-Yan LI ; Hui YAN ; Ya-Qin FENG
Acta Anatomica Sinica 2025;56(5):585-593
Objective To compare the differences in exosomes derived from testicular tissue between WT(wild type)mice and sdy mice with dysbindin-1(dystrobrevin binding protein 1)deletion mutations,and identify their protein components to explore the possible role of dysbindin-1 in the formation of exosomes derived from mouse testicular tissue.Methods The exosomes derived from mouse testicular tissue of WT and sdy mice were isolated by sucrose ultracentrifugation method.The expression of exosomes proteins was analyzed by Western blotting,the morphology of exosomes was observed by negative staining under transmission electron microscope(TEM),the particle size and distribution were analyzed by dynamic light scattering particle size analyzer,and the protein contents of exosomes were detected by mass spectrometry analysis.CD63+exosomes were obtained by immunoprecipitation with magnetic beads.Krt5(keratin5)protein was selected for validation.Results Dysbindin-1 deletion did not affect the morphology and quantity of exosomes,but decreased the expression of CD63,a marker of exosomes.Compared with the WT mice,there were 159 proteins that were highly expressed,209 proteins that were lowly expressed,and 184 proteins that were specifically expressed in the exosomes derived from sdy mice testicular tissue.In this experiment,CD63+exosomes from testicular tissue were obtained and 12 proteins were screened.There was indeed an interaction between krt5 protein and dysbindin-1.Interestingly,it was found that the expression of krt5 in the exosomes derived from sdy mice testicular tissue decreased after dysbindin-1 deletion.Conclusion After dysbindin-1 deletion,the morphology and quantity of exosomes derived from mouse testicular tissue are not affected,but dysbindin-1 may affect the types and content of exosomal proteins,by affecting the transport of exosome proteins through protein interactions.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Visualization and Analysis of Sweat Pore Features in Latent Fingerprints Using Core-Shell Structured Composite Nanofibrous Membrane
Shi-Yue MA ; Ya-Li PEI ; Hong-Yu CHEN ; Xin DU ; Yan-Feng ZHANG ; Rong-Liang MA ; Mei-Qin ZHANG
Chinese Journal of Analytical Chemistry 2025;53(8):1269-1278
Introducing fingerprint level 3 features(especially sweat pores)in fingerprint recognition can significantly improve the value of fingerprints.However,conventional fingerprint visualization methods suffer from issues such as poor stability and reproducibility,insufficient resolution,and feature masking in detecting level 3 features.Electrospun membrane has unique advantages in latent fingerprint(LFP)detection due to its excellent adsorption performance and high specific surface area,and thus its application potential in LFP visualization urgently need to be explored.A novel pore visualization method based on core-shell structured PAN-Flu/PVP composite nanofibrous membrane was proposed in this work.Specifically,the PAN-Flu/PVP composite nanofibrous membrane was prepared via coaxial electrospinning technology,with polyacrylonitrile(PAN)loaded with fluorescein(Flu)as the core and polyvinylpyrrolidone(PVP)as the shell.The experimental results showed that the prepared PAN Flu/PVP composite nanofibrous membrane had a porous structure and excellent adsorption performance.Based on the water solubility of the outer shell PVP and the water induced fluorescence enhancement effect of the core Flu,high-resolution visualization of sweat pores could be achieved within 2 s.The optimization experiment showed that the best quality of sweat latent fingerprints was obtained when the Flu content was 4 mg/mL,the spinning time was 1 h,and the sweating time was 2 min.Through repeated fingerprinting and live fingerprint comparison experiment,the strong stability and high reproducibility of the as-produced membrane in displaying fingerprint sweat pores were finally verified.In summary,the development method could quickly,stably and accurately extract the spatial distribution and activity level of fingerprint sweat pores,which was of great significance for improving the utilization and value of fingerprints.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail