1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Comparison of the effect of obesity indicators in predicting cardiovascular and cerebrovascular diseases among patients with type 2 diabetes mellitus
LU Jie ; ZHANG Ke ; WU Ya ; WANG Yue ; ZHANG Yue ; LU Ye ; WU Zhouli ; REN Zhihua ; HUANG Yiwen
Journal of Preventive Medicine 2025;37(9):886-891
Objective:
To explore the effect of different obesity indicators in predicting cardiovascular and cerebrovascular diseases (CVD) risk among patients with type 2 diabetes mellitus (T2DM), so as to provide the evidence for the early identification of CVD risk among T2DM patients.
Methods:
The patients with T2DM under community management in Qingpu District, Shanghai Municipality were selected as the study subjects in January 2025. Basic information such as gender, age, and blood glucose control status were collected through the Shanghai Chronic Disease Information Management System, while history of CVD were obtained from residents' electronic health records and the Shanghai Disease Control Information Platform. Obesity was assessed using body mass index (BMI), waist circumference (WC), BMI combined with WC, waist-to-height ratio (WHtR), and triglyceride (TG) combined with WC indicators. The association between obesity and CVD was analyzed using multivariable logistic regression models. The predictive effect of each obesity indicators for CVD was evaluated using the area under the receiver operating characteristic curve (AUC).
Results:
A total of 4 367 patients with T2DM were included, including 2 121 males (48.57%) and 2 246 females (51.43%). The average age was (68.71±8.05) years. The prevalence of CVD was 44.49%. Multivariable logistic regression analysis showed that after adjusting for age, education level, history of hypertension, duration of T2DM, use of glucose-lowering medications, renal function, and blood glucose control status, obese T2DM patients had a 389.4% increased risk of CVD compared to those with normal BMI; centrally obese T2DM patients had a 100.4% increased risk compared to those with normal WC; T2DM patients with isolated general obesity and compound obesity had 161.0% and 241.1% increased risks of CVD, respectively, compared to those with normal BMI and WC; centrally obese T2DM patients had a 100.4% increased risk compared to those with normal WHtR; T2DM patients with normal TG-high WC and high TG-high WC phenotypes had 83.1% and 68.8% increased risks of CVD, respectively, compared to those with normal TG and normal WC (all P<0.05). BMI had the highest AUC, at 0.714, with sensitivity and specificity of 0.675 and 0.642, respectively. This was followed by BMI combined with WC, which had an AUC of 0.707, with sensitivity and specificity of 0.635 and 0.679, respectively.
Conclusions
Obesity defined by BMI, WC, BMI combined with WC, WHtR, and TG combined with WC increases the risk of CVD among patients with T2DM. BMI and BMI combined with WC have better predictive effect in predicting CVD risk among patients with T2DM, and can be used as the primary obesity indicators for CVD risk screening.
7.Targeting B7-H3 inhibited growth,migration,and angiogenesis of human umbilical vein endothelial cells
Yu LIU ; Nan-Nan WANG ; Ke NIU ; Hui-Juan LING ; Ya-Yu ZHU ; Wei HU ; Li-Wen CHEN
Chinese Pharmacological Bulletin 2024;40(7):1311-1316
Aim To explore the effect of targeted inhi-bition of co-signaling molecule B7-H3 on the growth,migration,and angiogenesis ability of human umbilical vein endothelial cells(HUVECs).Methods Small interference RNA was used to knock down HUVECs B7-H3 molecules.CCK-8 test was used to detect cell proliferation at 24 h,48 h and 72 h.Transwell test was then used to detect 24 h cell migration,and three-dimensional cell culture was used to observe cell angio-genesis.Results Compared with the negative control group(siRNA-Control),siRNA-720,siRNA-1707 and siRNA-1690 had different inhibitory effects on the expression of B7-H3.B7-H3 inhibition of siRNA-1690 was significantly higher than that of siRNA-720 and siRNA-1707,and siRNA-1690 sequence was chosen for follow-up experiment.The results of CCK-8 cell vi-ability assay showed that the proliferation ability of HU-VECs decreased by 24%,22%(P>0.05,compared with 24 h)and 15%(P<0.05,compared with 48 h)respectively at 24 h,48 h and 72 h after B7-H3 knockout.The migration ability of B7-H3 for 24 h was significantly lower than that of siRNA-Control group(P<0.01).The results of three-dimensional cell cul-ture showed that the angiogenic ability of HUVECs de-creased significantly after si-B7-H3 knockdown of B7-H3 gene(P<0.01).Conclusion Targeting B7-H3 inhibits the growth,migration,and angiogenesis of hu-man umbilical vein endothelial cells.
8.Efficacy of alveolar lavage combined with montelukast in the treatment of acute exacerbations of chronic obstructive pulmonary disease and its effect on oxidative stress and inflammatory factors in patients
Guizhen ZHANG ; Shuang CHEN ; Jinggang LIU ; Ke ZHANG ; Ya MENG ; Na WANG ; Yaping GAO
Chinese Journal of Primary Medicine and Pharmacy 2024;31(9):1378-1383
Objective:To investigate the efficacy of alveolar lavage combined with montelukast in the treatment of acute exacerbations of chronic obstructive pulmonary disease (AECOPD) and its effect on oxidative stress and inflammatory factors in patients.Methods:A prospective study was conducted involving 90 patients with AECOPD who were admitted to the Intensive Care Unit of Shan County Central Hospital from December 2021 to December 2022. The patients were randomly divided into a control group and an observation group, with 45 patients in each group, using the random number table method. The control group received conventional treatment, while the observation group was additionally treated with alveolar lavage combined with montelukast. Symptom score, Acute Physiology and Chronic Health Evaluation II score, overall response rate, serum levels of oxidative stress markers (malondialdehyde, 4-hydroxynonenal, and superoxide dismutase), and serum levels of inflammatory factors (C-reactive protein, tumor necrosis factor-α, interleukin-6, and procalcitonin) were compared between the two groups before and after treatment.Results:After treatment, the symptom scores for both groups decreased significantly compared with their respective scores before treatment ( t = 6.68, 11.32, both P < 0.05). After treatment, the symptom score in the observation group was significantly lower than that in the control group [(8.69 ± 0.84) points vs. (15.39 ± 1.18) points, t = 8.75, P < 0.05]. After treatment, the Acute Physiology and Chronic Health Evaluation II score in the observation group was significantly lower than that in the control group ( t = 9.19, P < 0.05). The overall response rate in the observation group was significantly higher than that in the control group [93.33% (42/45) vs. 75.56% (34/45), t = 4.56, P < 0.05]. After treatment, serum levels of 4-hydroxynonenal and malondialdehyde in the observation group were significantly lower than those in the control group ( t = 4.20, 5.15, both P < 0.05), while serum level of superoxide dismutase in the observation group was significantly higher than that in the control group ( t = 5.23, P < 0.05). After treatment, serum levels of C-reactive protein, tumor necrosis factor-α, interleukin-6, and procalcitonin in the observation group were significantly lower than those in the control group ( t = 6.86, 5.60, 8.75, 4.89, all P < 0.05). Conclusion:Alveolar lavage combined with montelukast can reduce clinical symptoms in patients with AECOPD, promote recovery, enhances clinical efficacy, decreases oxidative stress responses, increases the body's antioxidant capacity, lowers the expression of inflammatory factors, and reduces inflammatory responses.
9.Secondary metabolites from endophytic fungi Candida sp.of Berberis atrocarpa
Ming-Zhuo GUO ; Shu-Fang MA ; Shi-Miao WANG ; Ya-Ping FENG ; Yan OUYANG ; Ke-Jian PANG ; Zi-Wei JIAO ; Xin-Zhou YANG
Chinese Traditional Patent Medicine 2024;46(9):3000-3005
AIM To study the secondary metabolites from the endophytic fungi Candida sp.of Berberis atrocarpa Schneid.METHODS The ethyl acetate fraction and petroleum ether fraction from the secondary metabolites of Candida sp.fermentation extract were separated and purified by silica gel,Sephadex LH-20 and preparative liquid chromatography,then the structures of obtained compounds were identified by physicochemical properties and spectral data.RESULTS Eighteen compounds were isolated and identified as 1-phenyl-1,2-ethanediol(1),4-hydroxyphenethyl alcohol(2),4-hydroxybenzoic acid(3),4-hydroxyphenylacetic acid(4),3-hydroxyphenylacetic acid(5),3-methylsulfinyl propionic acid(6),phenylacetic acid(7),(S)-N-nitroso-1-amino-p-hydroxy phenylethanol(8),2-phenylacetamide(9),p-hydroxybenzaldehyde(10),ethyl 2-(4-hydroxyphenyl)acetate(11),dibutyl phthalate(12),5,5'-dimethoxybiphenyl-2,2'-diol(13),3-indolealdehyde(14),N-acetyl-L-phenylalanine(15),9-hydroxy-10E,12Z-octadecadienoic acid(16),9-hydroxy-10E,12E-octadecadienoic acid(17),(6E)-5-methylene-6-tetradecenoic acid(18).CONCLUSION Compounds 1,3-8 and 10-18 are isolated from Candida sp for the first time.
10.Design,numerical simulation and experimental study of novel oxygenator
Ming-Hao YUE ; Shi-Yao ZHANG ; Ji-Nian LI ; Hui-Chao LIU ; Zi-Hua SU ; Ya-Wei WANG ; Zeng-Sheng CHEN ; Shi-Hang LIN ; Jin-Yu LI ; Ya-Ke CHENG ; Yong-Fei HU ; Cun-Ding JIA ; Ming-Zhou XU
Chinese Medical Equipment Journal 2024;45(3):23-28
Objective To design a novel oxygenator to solve the existing problems of extracorporeal membrane oxygenation(ECMO)machine in high transmembrane pressure difference,low efficiency of blood oxygen exchange and susceptibility to thrombosis.Methods The main body of the oxygenator vascular access flow field was gifted with a flat cylindrical shape.The topology of the vascular access was modeled in three dimensions,and the whole flow field was cut into a blood inlet section,an inlet buffer,a heat exchange zone,a blood oxygen exchange zone,an outlet buffer and a blood outlet section.The oxygenator was compared with Quadrox oxygenator by means of ANSYS FLUENT-based simulation and prototype experiments.Results Simulation calculations showed the oxygenator designed was comparable to the clinically used ones in general,and gained advantages in transmembrane pressure difference,blood oxygen exchange and flow uniformity.Experimental results indicated that the oxygenator behaved better than Quadrox oxygenator in transmembrane pressure difference and blood oxygen exchange.Conclusion The oxygenator has advantages in transmem-brane pressure difference,temperature change,blood oxygen ex-change and low probability of thrombosis.[Chinese Medical Equipment Journal,2024,45(3):23-28]