1.Dietary assessment of patients with chronic kidney disease
Hui HUANG ; Qian WANG ; Ya-Yong LUO ; Zheng-Chun TANG ; Fang LIU ; Rui-Min ZHANG ; Zhe-Yi DONG ; Xiang-Mei CHEN
Medical Journal of Chinese People's Liberation Army 2024;49(8):946-951
Chronic kidney disease(CKD)commonly used dietary assessments including 24-hour dietary recall(24 h DR)/3-day dietary recall(3DDR),food frequency questionnaire(FFQ),dietary records,and estimation of dietary protein intake based on nitrogen balance.Given the high prevalence of CKD patients in Asian population and the scarcity of research using FFQ method,it is crucial to develop an FFQ suitable for Chinese CKD patients.This review summarizes the advantages and disadvantages of dietary assessment methods for CKD,the current research status,and the content and steps involved in establishing an FFQ,with the aim of providing reference for the modification of FFQ for Chinese CKD patients.
2.Predictive value of artery blood flow parameters for fetal distress in mid-pregnancy fetus with oligohydramnios
Hui ZHONG ; Jing ZHAO ; Li-Na HE ; Hua JIN ; Ya-Yi LUO
Chinese Medical Equipment Journal 2024;45(5):60-66
Objective To predict fetal distress in oligohydramnios fetuses in mid-pregnancy by monitoring the blood flows in middle cerebral artery,renal artery and umbilical artery by means of ultrasound.Methods Totally 104 mid-pregnancy women with oligohydramnios in some hospital from January 2020 to May 2022 were selected retrospectively,and were divided into a distress group(n=43)and a non-distress group(n=48)based on the presence of fetal distress.Logistic multivariate regression was used to analyze the risk factors for the occurrence of fetal distress;the predictive value for fetal distress was assessed with ROC curves;a Bayesian network model was constructed and validated.Results The independent risk factors for fetal distress included abnormal findings in fetal movement,fetal cardiac monitoring,lipid levels and blood rheology indices and abnormal parameters of middle cerebral artery,renal artery,and umbilical artery(P<0.05).Higher predictive efficiency could be obtained for fetal distress when the blood flow parameters of middle cerebral artery,renal artery and umbilical artery were combined than only the parameters of only one artery were involved in.The Bayesian network model predicted an increase in the incidence of fetal distress from 49.9%to 61.50%when the probability of abnormality in all the three artery parameters was 100%,which proved to gain a high net benefit.Conclusion For mid-pregnancy women combined monitoring of the blood flow parameters of middle cerebral artery,renal artery and umbilical artery may predict fetal distress effectively.[Chinese Medical Equipment Journal,2024,45(5):60-66]
3.Feasibility Analysis of Establishing Combat Readiness Blood Bank Based on Low Titer Group O Whole Blood and Group A Plasma
Yuan-Yuan LUO ; Chun-Ya MA ; Li LIU ; Li-Hui FU ; Meng YI ; Yang YU
Journal of Experimental Hematology 2024;32(2):541-545
Objective:To explore the feasibility of establishing combat readiness blood bank with low titer group O whole blood and group A plasma.Methods:The Galileo automatic blood analyzer was used to detect the titers of IgM anti-A and anti-B antibodies in the samples of group O blood donors and IgM anti-B titer in the samples of group A blood donors.Group O blood donors with antibody titers below 128 were selected and included in the mobile blood bank for combat readiness,group A plasma with anti-B titer lower than 128 and group O whole blood with antibody titers below 128 were included in the combat readiness entity blood bank.Results:A total of 1 452 group O blood donors were selected,and the anti-A/B antibody titers were detected.Both antibody titers were distributed below 512,and both peak values of sample distribution were at titer 4.The proportion of samples with titers>128 for both antibodies was relatively low.There was a significant positive correlation between the titers of the two antibodies(r=0.383),and the proportion of samples with IgM anti-A titer higher than IgM anti-B titer was relatively high.1 335(91.94%)group O blood donors with IgM anti-A and anti-B antibody titers<128 could be included in the mobile blood bank.The anti-B titer of group A blood was detected in 512 cases and the results showed that as the antibody titer increased,the proportion of blood donors gradually decreased.99.8%of group A blood donors had anti-B antibody titer less than 128,and only one case did not meet the inclusion criteria.Conclusion:The proportion of group O blood donors whose whole blood meet the low antibody titer standard is high,and almost all plasma of group A blood donors meet the low titer standard,which improves the blood supply rate in emergencies.
4.Effects of Zuogui Jiangtang Tongmai Recipe on necroptosis pathway in a rat model of type 2 diabetes mellitus complicated with cerebral infarction
Yu-Zhe CAI ; Ding-Xiang LI ; Yi-Xuan LIU ; Zheng LUO ; Jing-Jing YANG ; Han-Lin LEI ; Ya-Nan ZHANG ; Qin WU ; Jing CHEN ; Yi-Hui DENG
Chinese Traditional Patent Medicine 2024;46(9):2936-2942
AIM To investigate the effects of Zuogui Jiangtang Tongmai Recipe on necroptosis pathway in a rat model of type 2 diabetes mellitus(T2DM)complicated with cerebral infarction(CI).METHODS The SD rats were randomly divided into the sham operation group,the model group,the metformin group(0.045 g/kg),and the low,medium and high dose Zuogui Jiangtang Tongmai Recipe groups(6.5,13,26 g/kg),with 9 rats in each group.In contrast to rats of the sham operation group,rats of the other groups were given 4 weeks feeding of high-sugar and high-fat diet combined with intraperitoneal injection of streptozotocin to establish a T2DM rat model with one week stable blood glucose,followed by gavage of corresponding drugs 3 days before the establishment of the middle cerebral artery occlusion(MCAO)model.After 7 days of administration,the rats had their CI injury assessed by mNSS method and TTC staining;their level of blood glucose detected by blood glucose meter;their levels of glycated serum protein,serum TNF-α and IL-1β detected by ELISA;their cerebral mRNA expressions of FADD,RIPK1,RIPK3 and MLKL detected by RT-qPCR;and their cerebral protein expressions of FADD,p-RIPK1,p-RIPK3 and p-MLKL detected by Western blot.RESULTS Compared with the sham operation group,the model group displayed increased levels of blood glucose value,glycosylated serum protein,neurological function score,cerebral infarction volume,cerebral FADD,RIPK1,RIPK3 and MLKL mRNA expressions,cerebral FADD,p-RIPK1,p-RIPK3 and p-MLKL protein expressions,serum TNF-α and IL-1β levels(P<0.01);and more disordered and morphologically diverse neurons with smaller nucleus.Compared with the model group,the groups intervened with medium or high dose Zuogui Jiangtang Tongmai Recipe,or metformin shared improvement in terms of the aforementioned indices(P<0.05,P<0.01);and more neurons with regular morphology neat arrangement,and reduced cell gap.CONCLUSION Zuogui Jiangtang Tongmai Recipe can improve the neurological dysfunction of the rat model of T2DM complicated with CI,which may associate with the inhibited activation of necroptosis signaling pathway.
5.Simultaneous content determination of eleven constituents in Elephantopus scabre by TRSDMC
Jia-Hui GUO ; Le GAO ; Ya-Qin ZHEN ; Yu-Luo CAI ; Jing-Nan HU ; Wei TIAN ; Li-Ying NIU
Chinese Traditional Patent Medicine 2024;46(11):3557-3564
AIM To establish a two reference substances for determination of multiple components(TRSDMC)method for the simultaneous content determination of neochlorogenic acid,chlorogenic acid,cryptochlorogenic acid,luteolin-7-O-glucuronide,isochlorogenic acid B,isochlorogenic acid A,isochlorogenic acid C,deoxyelephantopin,isodeoxyelephantopin,isoscabertopin and scabertopin in Elephantopus scabre L..METHODS The analysis was performed on a 35℃thermostatic Waters Symmetry C18,Phenomenex C18,Agilent ZORBAX Eclipse Plus C18 columns(4.6 mm×250 mm,5.0 μm),with the mobile phase comprising of acetonitrile and 0.1%phosphoric acid flowing at 1.0 mL/min in a gradient elution manner,and the detection wavelengths were set at 220,326 nm.Chlorogenic acid was used as an internal standard to calculate the relative correction factors of neochlorogenic acid,cryptochlorogenic acid,luteolin-7-O-glucuronide,isochlorogenic acid B,isochlorogenic acid A and isochlorogenic acid C,while isodeoxyelephantopin was used as an internal standard to calculate the relative correction factors of deoxyelephantopin,scabertopin and isoscabertopin,after which the content determination was made.Subsequently,cluster analysis,principal component analysis and orthogonal partial least squares-discriminant analysis were conducted.RESULTS Eleven constituents showed good linear relationships within their own ranges(r≥0.999 0),whose average recoveries were 95.3%-103.4%with the RSDs of 0.32%-3.45%.The result obtained by TRSDMC approximated those obtained by external standard method.Isochlorogenic acid A,isochlorogenic acid C,isochlorogenic acid B,chlorogenic acid,luteolin-7-O-glucuronide and cryptochlorogenic acid were taken as quality differential constituents.CONCLUSION This reliable and stable method can be used for the quality control of E.scabre.
6.Development and characteristics of automatic ash-removal heat-sensitive moxibustion device.
Xue-Tao ZHANG ; Han-Xiao WANG ; Zhen WANG ; Ya-Lu WANG ; Shuai CUI ; Mei-Qi ZHOU ; Hui LUO ; Can-Guang SUN ; Ming HAO ; Wen HONG ; Sheng-Bing WU
Chinese Acupuncture & Moxibustion 2023;43(5):597-599
An automatic ash-removal heat-sensitive moxibustion device was developed, which could keep relatively constant temperature of heat-sensitive moxibustion, and realize the automatic ignition and automatic ash removal of moxa sticks during heat-sensitive moxibustion. The automatic ash-removal heat-sensitive moxibustion device comprises a bracket and a moxibustion box fixed on the top of the bracket; the bracket is composed of a base and a movable telescopic arm. This device can solve the problems of temperature instability, moxa ash blocking heat transfer and moxa ash falling during heat-sensitive moxibustion, avoiding the scalding caused by moxa ash falling, and reduce the workload of medical staff.
Humans
;
Hot Temperature
;
Moxibustion
;
Temperature
8.The protective effects and underlying mechanisms of dapagliflozin on diabetes-induced testicular dysfunction.
Zhi-Chao LUO ; Zi-Run JIN ; Ya-Fei JIANG ; Tian-Jiao WEI ; Ya-Lei CAO ; Zhe ZHANG ; Rui WEI ; Hui JIANG
Asian Journal of Andrology 2023;25(3):331-338
Male diabetic individuals present a marked impairment in fertility; however, knowledge regarding the pathogenic mechanisms and therapeutic strategies is unsatisfactory. The new hypoglycemic drug dapagliflozin has shown certain benefits, such as decreasing the risk of cardiovascular and renal events in patients with diabetes. Even so, until now, the effects and underlying mechanisms of dapagliflozin on diabetic male infertility have awaited clarification. Here, we found that dapagliflozin lowered blood glucose levels, alleviated seminiferous tubule destruction, and increased sperm concentrations and motility in leptin receptor-deficient diabetic db/db mice. Moreover, the glucagon-like peptide-1 receptor (GLP-1R) antagonist exendin (9-39) had no effect on glucose levels but reversed the protective effects of dapagliflozin on testicular structure and sperm quality in db/db mice. We also found that dapagliflozin inhibited the testicular apoptotic process by upregulating the expression of the antiapoptotic protein B-cell lymphoma 2 (BCL2) and X-linked inhibitor of apoptosis protein (XIAP) and inhibiting oxidative stress by enhancing the antioxidant status, including total antioxidant capacity, total superoxide dismutase (SOD) activity, and glutathione peroxidase (GPx) activity, as well as decreasing the level of 4-hydroxynonenal (4-HNE). Exendin (9-39) administration partially reversed these effects. Furthermore, dapagliflozin upregulated the glucagon-like peptide-1 (GLP-1) level in plasma and GLP-1R expression by promoting AKT8 virus oncogene cellular homolog (Akt) phosphorylation in testicular tissue. Exendin (9-39) partially inhibited Akt phosphorylation. These results suggest that dapagliflozin protects against diabetes-induced spermatogenic dysfunction via activation of the GLP-1R/phosphatidylinositol 3-kinase (PI3K)/Akt signaling pathway. Our results indicate the potential effects of dapagliflozin against diabetes-induced spermatogenic dysfunction.
Mice
;
Animals
;
Male
;
Proto-Oncogene Proteins c-akt/metabolism*
;
Antioxidants
;
Phosphatidylinositol 3-Kinases/metabolism*
;
Semen/metabolism*
;
Diabetes Mellitus
9.Correlation Analysis of Hemolytic Transfusion Reaction Induced by Low Titer Antibody.
Yuan-Yuan LUO ; Chun-Ya MA ; Li-Hui FU ; Xin YANG ; Yang YU ; De-Qing WANG
Journal of Experimental Hematology 2023;31(2):503-508
OBJECTIVE:
To establish the diagnostic process of low titer blood group antibody in the occurrence of adverse reactions of hemolytic transfusion.
METHODS:
Acid elusion test, enzyme method and PEG method were used for antibody identification. Combined with the patient's clinical symptoms and relevant inspection indexes, the irregular antibodies leading to hemolysis were detected.
RESULTS:
The patient's irregular antibody screening was positive, and it was determined that there was anti-Lea antibody in the serum. After the transfusion reaction, the low titer anti-E antibody was detected by enhanced test. The patient's Rh typing was Ccee, while the transfused red blood cells were ccEE. The new and old samples of the patient were matched with the transfused red blood cells by PEG method, and the major were incompatible. The evidence of hemolytic transfusion reaction was found.
CONCLUSION
Antibodies with low titer in serum are not easy to be detected, which often lead to severe hemolytic transfusion reaction.
Humans
;
Blood Transfusion
;
Transfusion Reaction/prevention & control*
;
Hemolysis
;
Blood Group Antigens
;
Erythrocyte Transfusion
;
Antibodies
;
Isoantibodies
;
Blood Group Incompatibility
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail