1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Re-Exploration for Dietary Iodine Intake in Chinese Adults using the Obligatory Iodine Loss Hypothesis.
Xiao Bing LIU ; Jun WANG ; Ya Jie LI ; Hong Xing TAN ; De Qian MAO ; Yan Yan LIU ; Wei Dong LI ; Wei YU ; Jun An YAN ; Jian Hua PIAO ; Chong Zheng GUO ; Xiao Li LIU ; Xiao Guang YANG
Biomedical and Environmental Sciences 2025;38(8):952-960
OBJECTIVE:
This study aimed to reexplore minimum iodine excretion and to build a dietary iodine recommendation for Chinese adults using the obligatory iodine loss hypothesis.
METHODS:
Data from 171 Chinese adults (19-21 years old) were collected and analyzed based on three balance studies in Shenzhen, Yinchuan, and Changzhi. The single exponential equation was accordingly used to simulate the trajectory of 24 h urinary iodine excretion as the low iodine experimental diets offered (iodine intake: 11-26 μg/day) and to further deduce the dietary reference intakes (DRIs) for iodine, including estimated average requirement (EAR) and recommended nutrient intake (RNI).
RESULTS:
The minimum iodine excretion was estimated as 57, 58, and 51 μg/day in three balance studies, respectively. Moreover, it was further suggested as 57, 58, and 51 μg/day for iodine EAR, and 80, 81, and 71 μg/day for iodine RNI or expressed as 1.42, 1.41, and 1.20 μg/(day·kg) of body weight.
CONCLUSION
The iodine DRIs for Chinese adults were established based on the obligatory iodine loss hypothesis, which provides scientific support for the amendment of nutrient requirements.
Humans
;
Iodine/administration & dosage*
;
Male
;
Female
;
China
;
Young Adult
;
Diet
;
Adult
;
Nutritional Requirements
;
East Asian People
3.Research of miR-508-3p involvement in ovarian cancer progression by regulating ZEB1
Yu-hong XU ; Shuai-ying ZHU ; Jiang-jing SHAN ; Wei-ping ZHENG ; Hui-ya ZHANG ; Yun-gen WANG
The Chinese Journal of Clinical Pharmacology 2025;41(2):193-197
Objective To investigate the expression of microRNA-508-3p(miR-508-3p)in epithelial ovarian cancer(EOC)tissue,its impact on the migration and invasion of ovarian cancer cells,and its regulatory relationship with zinc-finger E-box-binding homeobox 1(ZEB1).Methods The surgical resection of EOC cancer tissues and paired adjacent normal tissues were collected.SKOV3 cells were divided into the NC mimic group(transfected with NC mimic),miR-508-3p mimic group(transfected with miR-508-3p mimic),si-NC group(transfected with si-NC),si-ZEB1 group(transfected with si-ZEB1)and co-transfection group(co-transfected with si-ZEB1 and miR-508-3p mimic).The mRNA expression levels of miR-508-3p and ZEB1 in EOC cancer tissues,adjacent normal tissues and five groups of cells were measured by real-time quantitative polymerase chain reaction.The Transwell assay was used to detect the cell migration and invasion abilities.Results The relative expression levels of miR-508-3p in EOC tissues and adjacent normal tissues were 0.77±0.36 and 1.07±0.40,the relative expression levels of ZEB1 mRNA in EOC tissues and adjacent normal tissues were 2.10±1.21 and 1.29±0.95,and the differences were statistically significant(all P<0.01).The migration cell number of the NC mimic,miR-508-3p mimic,si-NC,si-ZEB1 and co-transfection groups was 633.00±32.49,319.20±19.89,650.40±25.85,375.00±17.25 and 129.40±17.10;the invasion cell number was 527.20±25.01,288.60±16.68,520.00±25.83,293.40±18.37 and 76.60±8.76;the relative expression levels of miR-508-3p were 1.05±0.37,3.94±1.21,1.01±0.21,1.26±0.34 and 3.40±0.41;the relative expression levels of ZEB1 mRNA were 1.00±0.04,0.58±0.05,1.00±0.08,0.54±0.07 and 0.29±0.03,respectively.The above indicators showed statistically significant differences between the miR-508-3p mimic group and the NC mimic group,between the si-NC group and the co-transfection group(P<0.01,P<0.05).Conclusion MiR-508-3p is lowly expressed in EOC cancer tissue,and it may inhibit the migration and invasion of ovarian cancer cells by targeting ZEB1 expression.
4.Protective effect of Sanfeng Tongqiao Dropping Pills against house dust mite-induced allergic asthma in mice
Tong-wen ZUO ; Xiao-qun GU ; Shu-xian SUN ; Lin LI ; Ya-jun SONG ; Fu-man HUANG ; Qian ZHAO ; Kang ZHOU ; Jie ZHENG ; Min HONG
Chinese Traditional Patent Medicine 2025;47(8):2542-2549
AIM To investigate the protective effect of Sanfeng Tongqiao Dropping Pills against house dust mite(HDM)-induced allergic asthma in mice.METHODS Compared to the intact BALB/c mice in the blank control group,the BALB/c mice randomly assigned into the model group,the dexamethasone group(0.67 mg/kg),and the low-dose,medium-dose,and high-dose Sanfeng Tongqiao Dropping Pills groups(15,30 and 60 mg/kg),were induced into acute allergic asthma models via weekly intraperitoneal sensitization with 0.1 mL HDM solution(0.5 mg/mL)for three weeks followed by three consecutive daily intranasal challenges with 10 μL HDM solution(2.5 mg/mL)starting in the third week.The drug administered continuously 7 days after the last excitation.The mice had their airway reactive Penh value detected,their pulmonary pathological changes observed by HE staining,their blood eosinophils(EOS)counted,their Th2 cytokines in lung tissue and serum IgE levels detected by ELISA,and their number of peripheral blood mononuclear cells(PBMC)and pulmonary Th2 cells detected by flow cytometry.Chronic allergic asthma was induced in grouped BALB/c mice through repeated intranasal challenges with 10 μL HDM solution(2.5 mg/mL)administered five times weekly for five consecutive weeks.Drug treatment continued for 14 days following the final challenge.After the final treatment,the mice had their pulmonary pathological changes observed by HE staining,and their levels of Th2 cytokines in B ALF and lung tissue and serum IgE detected by ELISA.RESULTS Compared to the blank control group,the acute allergic asthma model group exhibited increases in Penh value,EOS count and IgE level in serum,IL-4 and IL-5 levels in lung tissue(P<0.01);obvious pulmonary inflammatory cells infiltration,and thickened airway wall;and increase in pulmonary number of Th2 cells(P<0.01).Compared to the model group,the groups intervened with Sanfeng Tongqiao Dropping Pills demonstrated decreased Penh value,serum EOS count,IgE level and IL-5 level in lung tissue(P<0.05,P<0.01);reduced pulmonary inflammatory infiltration and alleviated airway wall thickening;and decreased number of pulmonary Th2 cells.Compared to the blank group,the chronic allergic asthma model group showed obvious pulmonary inflammatory infiltration and airway wall thickening;and increased EOS count and IgE level in serum,IL-4 and IL-13 in lung tissue and IL-14 in BALF(P<0.05,P<0.01).Compared to the model group,the groups intervened with either medium-dose or high-dose Sanfeng Tongqiao Dropping Pills demonstrated reduced pulmonary inflammatory infiltration;and decreased serum EOS count,IgE level,IL-13 in lung tissue and IL-14 in BALF(P<0.05,P<0.01).CONCLUSION Sanfeng Tongqiao Dropping Pills reduce Th2 cells in peripheral blood and lung tissue,suppress type 2 inflammation,and thereby alleviate allergic asthma.
5.Study of debridement effects of multi shapes of plasma scalpels in explosion injury model
Hong-ye ZHENG ; Yu LI ; Zi-heng XU ; Yu-fan WEI ; Bo-ya ZHANG ; Yan LI ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(2):31-38
Objective To explore the debridement effects of 3 types of plasma scalpels for the animal model of explosion injury,and to compare them with the steel scalpel and high-frequency electrosurgical scalpel.Methods Firstly,blast wounds were constructed in the right inguinal regions of 9 Landrace pigs by high-pressure gas impact combined with preset metal shrapnel.Secondly,debridement was carried out in experimental groups with wide-,arrow-or needle-type plasma scalpel and in control groups with steel and high-frequency electrisurgical scalpel,with the operating temperature and debridement time recorded during the procedure and trauma specimens analyzed pathologically after the debridement;comparisons were performed among the five types of scalpels in terms of debridement effect,and among the four ones in terms of maximum operating temperature and depth of tissue thermal damage under electrocutaneous cutting and electrocoagulation modes with the steel scalpel excluded because it did not generate any heat.GraphPad Prism 9.5.1 software was used for statistical analysis.Results There were no significant differences in debridement effect found between the three plasma scalpels and the steel and high-frequency electrosurgical scalpels(P>0.05).The three types of plasma scalpels had the maximum operating temperature lower significantly than that of the high-frequency electrosurgical scalpel during debridement(P<0.05).Under electrosection and electrocoagulation modes the three plasma scalpels had the depths of tissue thermal damage statistically less than that by the high-frequency electrosurgical scalpel under electrosection and electrocoagulation modes(P<0.05).The depths of tissue thermal damage by the four scalpels under electrocoagulation mode were obviously greater than those under electrosection mode(P<0.05).Conclusion Multi shapes of plasma scalpels behave well in debridement with low operating temperature,little tissue thermal damage and high efficiency for wound protection and the same efficacy with the steel scalpel and high-frequency electrosur-gical scalpel.[Chinese Medical Equipment Journal,2025,46(2):31-38]
6.A quality improvement study on improving the follow-up rate of preterm infants after discharge.
He-Sheng CHANG ; Xue YANG ; Jun JU ; Wen-Ya XU ; Di WU ; Xiao-Man WAN ; Zheng-Hong LI
Chinese Journal of Contemporary Pediatrics 2025;27(2):148-154
OBJECTIVES:
To explore the measures to improve the follow-up rate of preterm infants after discharge, and to evaluate the effectiveness of these measures using quality improvement methodology.
METHODS:
The follow-up status of preterm infants discharged from March to May 2017 was used as the baseline before quality improvement, and a specific quality improvement goal for the follow-up rate was proposed. The Pareto chart was used to analyze the causes of follow-up failure, and a key driver diagram was constructed based on the links involved in improving follow-up rate. The causes of failure were analyzed to determine the key links and intervention measures for quality improvement, and the follow-up rate was monitored weekly using a control chart until the quality improvement goal was achieved.
RESULTS:
The follow-up rate of preterm infants after discharge was 57.92% (117/202) at baseline before quality improvement, and the quality improvement goal was set to increase the follow-up rate of preterm infants from baseline to more than 80% within 12 months. The Pareto chart analysis showed that the main causes of follow-up failure were deficiencies in follow-up file management and irregular follow-up times (33.70%, 31/92), insufficient follow-up education and poor communication (25.00%, 23/92), and the inability to meet the diverse needs of parents (18.48%, 17/92). Based on the key links for quality improvement and the main causes of follow-up failure, the following intervention measures were adopted: (1) strengthen follow-up publicity and education; (2) build a follow-up team; and (3) establish a follow-up platform and system. The control chart indicated that with the implementation of the above intervention measures, the weekly follow-up rate increased to 74.09% (306/413) in July 2017 and 83.09% (511/615) in December 2017, finally achieving the quality improvement goal. During the COVID-19 pandemic, the follow-up rate of preterm infants fluctuated between 23.54% (460/1 954) and 70.97% (1 931/2 721), and subsequently, it returned to pre-pandemic levels starting in February 2023.
CONCLUSIONS
The application of quality improvement methodology can help to formulate intervention measures based on the main causes of follow-up failure, thereby improving the follow-up rate of preterm infants after discharge. This quality improvement method is feasible and practical and thus holds promise for clinical application.
Humans
;
Quality Improvement
;
Infant, Premature
;
Infant, Newborn
;
Patient Discharge
;
Follow-Up Studies
;
Female
;
Male
7.Correlation of knee joint asymmetry with balance and walking ability in hemiplegic stroke patients
Zheng-Hua XIAO ; Jiang MA ; Hong LI ; Fang WANG ; Li-Ying GUO ; Xiao-Lin TAO ; Feng ZHANG ; Ya-Yong LI ; Xiao-Li YAN
Medical Journal of Chinese People's Liberation Army 2025;50(2):134-140
Objective To explore the correlation of bilateral knee joint strength asymmetry with balance,walking ability,and motor function in hemiplegic stroke patients,providing a reference for clinical assessment of stroke patients.Methods A total of 46 hemiplegic stroke patients admitted to the Rehabilitation Medicine Department of People's Hospital of Shijiazhuang from February to December 2023 were selected.According to the Berg Balance Scale(BBS)scores,patients were divided into Group A(BBS score≤20,n=23)and Group B(BBS score>20,n=23).The peak torque and differences of bilateral knee flexors and extensors were compared between two groups.Isokinetic technology was used to assess the differences in peak torque of bilateral knee joints at 60°/s and 120°/s.BBS,Functional Ambulation Classification(FAC),and Fugl-Meyer Assessment of Lower Extremity(FMA-LE)were used to evaluate patients'balance,walking ability,and lower limb motor function.The correlation between bilateral knee joint peak torque and its difference with the scores of three functional scales was analyzed.Results The peak torque of knee flexors and extensors at 60°/s in group A was significantly lower than that in group B(P<0.05).At both 60°/s and 120°/s the differences in peak torque between the healthy and affected sides of knee flexors and extensors were greater than those in group B(P<0.05).At 60°/s,the difference in peak torque of bilateral knee extensors in hemiplegic stroke patients was negatively correlated with the scores of BBS,FAC,and FMA-LE(r=-0.569,-0.582,-0.606,P<0.01),as did the knee flexors(r=-0.534,-0.386,-0.458,P<0.05).At 120°/s,similar negative correlations were observed for both knee extensors(r=-0.304,-0.304,-0.443,P<0.05)and flexors(r=-0.337,-0.349,-0.370,P<0.05).Conclusions Bilateral knee joint strength asymmetry in hemiplegic stroke patients is negatively correlated with balance and walking ability.The difference in strength between the two sides of knee joint may be one of the clinical indicators for evaluating the motor function of stroke patients.
8.Efficacy and Safety of Blinatumomab in Adult Patients with B-Cell Acute Lymphoblastic Leukemia
Ya-Lei HU ; Yong-Feng SU ; Yang LI ; Xuan ZHENG ; An WANG ; Yi-Zhi WANG ; Lei XU ; Chun-Ji GAO ; Liang-Ding HU ; Dai-Hong LIU ; Xiao-Ning GAO
Journal of Experimental Hematology 2025;33(6):1571-1576
Objective:To evaluate the efficacy and safety of blinatumomab in adult patients with relapsed/refractory(R/R)or measurable residual disease(MRD)positive B-cell acute lymphoblastic leukemia(B-ALL)in the real world.Methods:The clinical data of 30 B-ALL patients received at least 1 course of blinatumomab therapy in the Chinese PLA General Hospital from January 1st,2021 to December 31st,2023 were retrospectively analyzed,including pre-treatment baseline clinical feature,post-treatment complete response(CR),CR with partial hematologic recovery(CRh),CR with incomplete hematologic recovery(CRi),complete MRD response rate,MRD response rate(MRD<10-4),overall survival(OS),and disease-free survival(DFS),as well as drug-related adverse reactions.Results:Among 5 patients who were not assessed 4 were MRD negative and 1 did not receive bone marrow biopsy.In the R/R B-ALL group(13 cases),11 patients achieved CR/CRh/CRi and 10 patients achieved complete MRD response.In MRD+group(12 cases),9 patients achieved overall MRD response and 7 patients achieved complete MRD response.The median follow-up time was 8.4(95%CI:6.3-10.4)months.The median OS was 15.5(95%CI:0.7-30.3)months in the R/R group,while not reached in the MRD+group.The median DFS of the two groups were not reached.Drug-related adverse reactions occurred in 22 patients,and pyrexia was the most common(13 cases).Grade ≥3 adverse reactions occurred in 15 patients,and neutropenia was the most common(9 cases).Cytokine release syndrome occurred in 6 patients,including 5 cases with grade 1 and 1 case with grade 3.No patients interrupted therapy or died due to drug-related adverse reactions.Conclusion:Blinatumomab is effective in the treatment of R/R or continuous MRD+B-ALL with acceptable adverse reactions.
9.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]
10.Research on the Application of TaqMan-MGB Probe Method in Detecting MTHFR Gene Polymorphisms
Hong-xuan LIANG ; Liang-hui CHEN ; Xuan-yi ZHENG ; Qiong-lu HUANG ; Kang ZHANG ; Qiu-ping YE ; Ya-qun LIU
Progress in Modern Biomedicine 2025;25(16):2598-2607
Objective:To establish a TaqMan-MGB probe-based method for detecting the polymorphic loci C677T and A1298C of the MTHFR gene.Methods:Specific primers and TaqMan-MGB probes targeting the C677T and A1298C polymorphic loci of the MTHFR gene were designed and optimized based on the gene sequence information.A real-time quantitative PCR detection system was established.Gradient dilution experiments were conducted to determine the limit of detection,and reproducibility experiments were performed to evaluate detection consistency.Specificity was validated using wild-type and mutant plasmid templates.The method was applied to detect 56 clinical samples,and its accuracy and practicality were assessed through comparison with traditional Sanger sequencing.Results:The TaqMan-MGB probe method demonstrated high specificity for detecting the C677T and A1298C loci,with no cross-reactivity between wild-type and mutant probes,enabling accurate genotype differentiation.Sensitivity experiments revealed detection limits of 1.13 × 103 copies/μL for C677T and 8.39 × 101 copies/μL for A1298C.Reproducibility experiments showed coefficients of variation below 1%,indicating stable and reliable results.Among the 56 clinical samples,the overall detection rate for the C677T locus was 86.99%,and for the A1298C locus,it was 97.92%.The TaqMan-MGB method exhibited good concordance with Sanger sequencing results.Conclusion:The TaqMan-MGB method exhibits high specificity,sensitivity,and excellent reproducibility in detecting the polymorphic loci C677T and A1298C of the MTHFR gene,making it suitable for rapid detection in large-scale clinical samples.This method provides an effective molecular diagnostic tool for the early diagnosis and prevention of folate-related diseases.

Result Analysis
Print
Save
E-mail