1.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
2.Isolation,identification,and biological characterization of enterotoxigenic Escherichia coli from a South China tiger
Jing-ru XU ; Zhi-hao ZHU ; Yu-qi LI ; Si-si FAN ; Ya-li KANG ; Yu-bin ZHUO ; Ling-shan HUANG ; Shu-qi QIU ; XUE-YUXI ; Xiao-ping WU ; Yu-ting LIAO ; Wei-ye LIN ; Xiao-ziyi XIAO ; Xue-jin LI ; Teng-teng CHEN ; Xi-pan LIN ; Kai-xiong LIN ; Ke-wei FAN
Chinese Journal of Zoonoses 2025;41(6):567-573
This study was aimed at identifying the pathogenic bacteria responsible for the death of a young tiger at the Fujian Meihua Mountain South China Tiger Breeding Research Institute.Tissue samples from the lungs,liver,and intestines of the deceased tiger were collected,and the bacteria were cultured inasterile environment.The bacterial strains were characterized according to their morphological and molecular biological properties,including assessment of virulence genes and antibiotic resistance genes,mouse lethality tests,and antibiotic susceptibility evaluations.A predominant bacterial strain isolated from the liver of the deceased tiger was identified as enterotoxigenic Escherichia coli(ETEC)strain Tiger22513F.Phylogenetic analysis of the 16S rRNA gene revealed that the Tiger22513F strain exhibited close genetic similarity to the reference strain ETEC(MF919609.1),with 99.9%nucleotide similarity,and resided on the same evolutionary branch.The Tiger22513F strain contained 11 antibiotic resistance genes(tetA,sul1,sul3,cmlA,floR,blaTEM,blaSHV,blaCMY-2,qnrA,qnrS,and qnrD)along with five virulence genes(VT1,fyuA,tsh,iucD,and ST).Mouse lethality tests indicated significant pathogenicity toward mice,affecting primarily the lungs,liver,and intestines.Antibiotic susceptibility testing demonstrated that this strain exhibited resistance to various classes of beta-lactam antibiotics,as well as quinolones and aminoglycosides.This investigation successfully isolated a multi-drug resistant enterotoxigenic Escherichia coli strain with pronounced pathogenicity from the liver of a deceased tiger;thus providing valuable scientific insights for clinical diagnosis,as well as prevention and control measures,against ETEC infections in South China tigers.
3.Cross-sectional survey of healthcare-associated infection in 5 736 medical institutions across China in 2024
Cui ZENG ; Wuqiang GAO ; Fu QIAO ; Hui ZHAO ; Xu FANG ; Linping LI ; Xiuwen CHEN ; Jiansen CHEN ; Dan LI ; Yuan ZHOU ; Lingli YU ; Qinglan MENG ; Xia MOU ; Lijuan XIONG ; Weiguang LI ; Ding LIU ; Jiaqing XIAO ; Limei OU ; Baozhen LI ; Jun YIN ; Haojun ZHANG ; Qiang FU ; Qun LU ; Biao WU ; Ya-wei XING ; Shumei SUN ; Shuncai WANG ; Longmin DU ; Jingping ZHANG ; Wen-ying HE ; Gui CHENG ; Nan REN ; Xun HUANG ; Anhua WU
Chinese Journal of Infection Control 2025;24(11):1572-1583
Objective To understand the current situation of healthcare-associated infection(HAI)in China,pro-vide data support and decision-making basis for formulating scientific and effective strategies for HAI prevention and control.Methods A nationwide cross-sectional survey on HAI was conducted among various types and levels of medical institutions in China according to a unified protocol of bedside surveys and case investigations.Results In 2024,a total of 5 736 medical institutions and 2 751 765 patients were surveyed.Among them,34 889 HAI cases were identified,with a prevalence rate of 1.27%.The number of HAI episodes was 38 032,and case prevalence rate was 1.38%.The prevalence rate of HAI in medical institutions in different regions of China ranged from 0.66%to 2.35%.Among medical institutions of different scales,those with a bed capacity of ≥900 had the high-est incidence of HAI,reaching 1.65%.The most common infection site was the lower respiratory tract(44.66%),followed by the urinary tract(12.94%),surgical site(9.32%),upper respiratory tract(7.02%),and bloodstream infection(5.78%).The top 3 departments with the highest HAI rates were the general intensive care unit(10.02%),department of neurosurgery(5.51%),and department(group)of hematology(5.34%).A total of 23 238 strains of HAI pathogens were detected,with 10 714 strains(46.10%)from lower respiratory tract speci-mens.The top 5 detected strains were Klebsiella pneumoniae(14.76%),Pseudomonas aeruginosa(13.33%),Escherichia coli(12.79%),Acinetobacter baumannii(9.23%),and Staphylococcus aureus(7.88%).231 944 pa-tients underwent class Ⅰ incision surgery were monitored,with 1 647 cases experienced surgical site infection,and the prevalence rate of surgical site infection was 0.71%.The number of patients who should undergo pathogen de-tection(patients receiving therapeutic and therapeutic combined prophylactic antimicrobial agents)was 715 179,while the actual number was 480 492,with a pathogen detection rate of 67.18%.425 225 patients received patho-genic detection before treatment,with a detection rate of 59.46%.Conclusion The overall HAI prevalence in Chi-na is lower,showing disparities among medical institutions of different regions and scales.Therefore,precise imple-mentation of measures is necessary for HAI prevention and control,with a focus on high-risk institutions and high-risk departments,key areas,and critical procedures.All levels of medical institutions should continuously reduce the incidence of HAI by strengthening monitoring,standardizing the use of antimicrobial agents,and reinforcing basic HAI prevention and control measures.
4.Influence of Preoperative Visit in Operating Room Based on"Internet Plus"on Perioperative Negative Emotion,Sleep Quality and Stress Response of Elderly Patients
Ya TANG ; Chao-rong LU ; Guo-xin XIONG ; Xue-juan ZHANG
Progress in Modern Biomedicine 2025;25(11):1905-1912
Objective:To investigate the effects of preoperative visit in operating room based on"internet plus"on perioperative negative emotion,sleep quality and stress response of elderly patients.Methods:142 elderly patients who underwent surgery in the Yancheng No.1 People's Hospital from From February 2022 to February 2024 were selected,the patients were randomly divided into observation group(n=71,preoperative visit in operating room based on"internet plus")and control group(n=71,traditional preoper ative visit).The perioperative indicators(heart rate,systolic blood pressure,diastolic blood pressure),negative emotions[Self Rating Anxiety Scale(SAS),Self Rating Depression Scale(SDS)],sleep quality[Pittsburgh Sleep Quality Index(PSQI)score],stress response indicators[C-reactive protein(CRP),cortisol(Cor),norepinephrine(NE),epinephrine(E)]were compared between the two groups.Results:Heart rate after intervention increased,systolic blood pressure,diastolic blood pressure,SAS,SDS scores,PSQI scores,CRP,Cor,NE and E decreased,and the change range of observation group was greater than that of control group(P<0.05).Conclusion:Preoperative visit in operating room based on"internet plus"can effectively reduce the negative emotions of elderly patients,improve the quality of sleep,and alleviate the stress reaction through early communication,rich information,convenient,efficient and personalized service.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.A Novel Mouse Model Unveils Protein Deficiency in Truncated CDKL5 Mutations.
Xue FENG ; Zi-Ai ZHU ; Hong-Tao WANG ; Hui-Wen ZHOU ; Ji-Wei LIU ; Ya SHEN ; Yu-Xian ZHANG ; Zhi-Qi XIONG
Neuroscience Bulletin 2025;41(5):805-820
Mutations in the cyclin-dependent kinase-like 5 gene (CDKL5) cause a severe neurodevelopmental disorder, yet the impact of truncating mutations remains unclear. Here, we introduce the Cdkl5492stop mouse model, mimicking C-terminal truncating mutations in patients. 492stop/Y mice exhibit altered dendritic spine morphology and spontaneous seizure-like behaviors, alongside other behavioral deficits. After creating cell lines with various Cdkl5 truncating mutations, we found that these mutations are regulated by the nonsense-mediated RNA decay pathway. Most truncating mutations result in CDKL5 protein loss, leading to multiple disease phenotypes, and offering new insights into the pathogenesis of CDKL5 disorder.
Animals
;
Disease Models, Animal
;
Mice
;
Protein Serine-Threonine Kinases/deficiency*
;
Mutation/genetics*
;
Epileptic Syndromes/genetics*
;
Humans
;
Dendritic Spines/pathology*
;
Spasms, Infantile/genetics*
;
Male
;
Seizures/genetics*
;
Mice, Inbred C57BL
7.Traditional Chinese medicine understanding and treatment of acute myocardial infarction complicated with acute upper gastrointestinal bleeding.
Xing-Jiang XIONG ; Fu-Kun LUO ; Xiao-Ya WANG ; Yu LAN ; Peng-Qian WANG
China Journal of Chinese Materia Medica 2025;50(7):1969-1973
Acute myocardial infarction and acute upper gastrointestinal bleeding are both critical internal medicine conditions. The incidence of acute upper gastrointestinal bleeding in patients with acute myocardial infarction ranges from 5.31% to 8.90%, with a mortality rate as high as 20.50% to 35.70%. The pathogenesis may be related to the use of antiplatelet and anticoagulant drugs, as well as stress-induced injury. In treatment, the contradiction between antiplatelet/anticoagulation therapy and bleeding has made this disease a significant challenge in modern medicine. Therefore, re-exploring the etiology, pathogenesis, treatment principles, and methods of traditional Chinese medicine(TCM) for acute myocardial infarction and acute upper gastrointestinal bleeding is of great clinical importance. The research team has been working year-round in the coronary care unit(CCU), managing a large number of such severe patients. By revisiting classic texts and delving into the foundational theories of TCM and historical medical literature, it has been found that this disease falls under the category of "distant blood" in the Synopsis of the Golden Chamber. In terms of etiology, it is primarily associated with weakness of healthy Qi and damage caused by drug toxicity. In terms of pathogenesis, in the acute stage, it mainly manifests as insufficient spleen Yang, deficiency of spleen Qi, and failure of the spleen to control blood. In the remission stage, it is characterized by deficiency of both heart Qi and spleen blood. For treatment, during the acute stage, Huangtu Decoction is used to warm Yang and restrain blood, while in the remission stage, Guipi Decoction is administered to tonify Qi and nourish blood. During the treatment process, for patients with acute myocardial infarction complicated with acute upper gastrointestinal bleeding, it is crucial to flexibly apply the treatment principles of "Nil per os" in western medicine and "where there is stomach Qi, there is life; where there is no stomach Qi, there is death" in TCM. Early intervention with Huangtu Decoction can also prevent bleeding, with large doses being key to achieving hemostasis. It is important to address the pathogenesis of heat syndrome in addition to the core pathogenesis of Yang deficiency bleeding and to emphasize the follow-up treatment with Guipi Decoction for a successful outcome.
Humans
;
Gastrointestinal Hemorrhage/etiology*
;
Myocardial Infarction/drug therapy*
;
Drugs, Chinese Herbal/therapeutic use*
;
Medicine, Chinese Traditional
;
Acute Disease
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail