1.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
2.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
3.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
4.Highly Sensitive Detection of Water in Organic Solvents Using Pyrene-Phenol-based Fluorescent Probe
Jing LIANG ; Yan-Li WANG ; Cui-Wen JIANG ; Xiao-Chuan HUANG ; Li TANG ; Tao LI ; Yu YA ; De-Jiao NING ; Li-Ping XIE ; Fei-Yan YAN
Chinese Journal of Analytical Chemistry 2025;53(6):894-902,中插1-中插5
A pyrene-phenol-based fluorescent probe PyP which showed typical intramolecular charge transfer(ICT)and monomer-excimer activities was synthesized by using pyrene carboxaldehyde hydrazone and 4-tert-butyl-2,6-diformylphenol as the raw materials.The effects of solvents on PyP were studied,and the results showed that the color of protic polar solvents(Ethanol,N,N-dimethylformamide,methanol and H2O)were successfully identified.Based on the solvent polarity-regulated PyP monomer-excimer switching,the rapid and highly sensitive ratiometric probe,"Turn-off"and"Turn-on"multimodal probes were established for detection of trace water content in organic solvents(Dimethyl sulfoxide,N,N-dimethylformamide,ethanol and methanol),with detection limits(3σ/k)of 0.0021%,0.046%,0.062%and 0.024%.The method was successfully used to detect water content in dimethyl sulfoxide,N,N-dimethy lformamide,ethanol and methanol commercial organic solvents,with recoveries ranging from 97.2%to 108.0%.The developed method showed good accuracy and stability,and had good application prospect.
5.Bone Age Estimation of Chinese Han Adolescents's and Children's Elbow Joint X-rays Based on Multiple Deep Convolutional Neural Network Models
Dan-Yang LI ; Hui-Ming ZHOU ; Lei WAN ; Tai-Ang LIU ; Yuan-Zhe LI ; Mao-Wen WANG ; Ya-Hui WANG
Journal of Forensic Medicine 2025;41(1):48-58
Objective To explore a deep learning-based automatic bone age estimation model for elbow joint X-ray images of Chinese Han adolescents and children and evaluate its performance.Methods A total of 943(517 males and 426 females)elbow joint frontal view X-ray images of Chinese Han ado-lescents and children aged 6.00 to<16.00 years were collected from East,South,Central and North-west China.Three experimental schemes were adopted for bone age estimation.Scheme 1:Directly in-put preprocessed images into the regression model;Scheme 2:Train a segmentation network using"key elbow joint bone annotations"as labels,then input segmented images into the regression model;Scheme 3:Train a segmentation network using"full elbow joint bone annotations"as labels,then in-put segmented images into the regression model.For segmentation,the optimal model was selected from U-Net,UNet++and TransUNet.For regression,VGG16,VGG19,InceptionV2,InceptionV3,ResNet34,ResNet50,ResNet101 and DenseNet121 models were selected for bone age estimation.The dataset was randomly split into 80%(754 samples)for training and validation for model fitting and hyperparameter tuning,and 20%(189 samples)as an internal test set to test the performance of the trained model.An additional 104 elbow joint X-ray images from the same demographic and age group were col-lected and used as an external test set.Model performance was evaluated by comparing the mean ab-solute error(MAE),root mean square error(RMSE),accuracies within±0.7 years(P±0.7 years)and±1.0 years(P±1.0 years)between the estimated age and the actual age,and by drawing radar charts,scat-ter plots,and heatmaps.Results When segmented with Scheme 3,the UNet++model achieved good segmentation performance with a segmentation loss of 0.000 4 and an accuracy of 93.8%at a learning rate of 0.000 1.In the internal test set,the DenseNet121 model with Scheme 3 yielded the best results with MAE,P±0.7 years and P±1.0 years being 0.83 years,70.03%,and 84.30%,respectively.In the external test set,the DenseNet121 model with Scheme 3 also performed best,with an average MAE of 0.89 years and an average RMSE of 1.00 years.Conclusion When performing automatic bone age estima-tion using elbow joint X-ray images in Chinese Han adolescents and children,it is recommended to use the UNet++model for segmentation.The DenseNet121 model with Scheme 3 achieves optimal per-formance.Using segmentation networks,especially that trained with annotation areas encompassing the full elbow joint including the distal humerus,proximal radius,and proximal ulna,can improve the ac-curacy of bone age estimation based on elbow joint X-ray images.
6.Dual-Channel Shoulder Joint X-ray Bone Age Estimation in Chinese Han Ado-lescents Based on the Fusion of Segmentation Labels and Original Images
Hui-Ming ZHOU ; Dan-Yang LI ; Lei WAN ; Tai-Ang LIU ; Yuan-Zhe LI ; Mao-Wen WANG ; Ya-Hui WANG
Journal of Forensic Medicine 2025;41(3):208-216
Objective To explore a deep learning network model suitable for bone age estimation using shoulder joint X-ray images in Chinese Han adolescents.Methods A retrospective collection of 1 286 shoulder joint X-ray images of Chinese Han adolescents aged 12.0 to<18.0 years(708 males and 578 females)was conducted.Using random sampling,approximately 80%of the samples(1 032 cases)were selected as the training and validation sets for model learning,selection and optimization,and the other 20%samples(254 cases)were used as the test set to evaluate the model's generalization ability.The original single-channel shoulder joint X-ray images and dual-channel inputs combining original images with segmentation labels(manually annotated shoulder joint regions multiplied pixel-by-pixel with original images,followed by segmentation via the U-Net++network to retain only key shoulder joint region information)were respectively input into four network models,namely VGG16,ResNet18,ResNet50 and DenseNet121 for bone age estimation.Additionally,manual bone age estimation was con-ducted on the test set data,and the results were compared with the four network models.The mean absolute error(MAE),root mean square error(RMSE),coefficient of determination(R2),and Pear-son correlation coefficient(PCC)were used as main evaluation indicators.Results In the test set,the bone age estimation results of the four models with dual-channel input of shoulder joint X-ray images outperformed those with single-channel input in all four evaluation indicators.Among them,DenseNet121 with dual-channel input achieved best results with MAE of 0.54 years,RMSE of 0.82 years,R2 of 0.76,and PCC(r)of 0.88.Manual estimation yielded an MAE of 0.82 years,ranking second only to dual-channel DenseNet121.Conclusion The DenseNet121 model with dual-channel input combined with original images and segmentation labels is superior to manual evaluation results,and can effectively estimate the bone age of Chinese Han adolescents.
7.Temporomandibular joint capsule suspension for neocondyle stability in free fibular flap reconstruction of the mandibular condyle
Shuang BAI ; Yao YU ; Wen-Bo ZHANG ; Ya-Qing MAO ; Yang WANG ; Chi MAO ; Dian-Can WANG ; Xin PENG
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(1):46-53
Objectives:
This study evaluates the efficacy of a new temporomandibular joint (TMJ) capsule suspension technique for stabilizing the TMJ after free fibular flap reconstruction of the mandibular condyle.
Patients and Methods:
Patients undergoing the TMJ capsule suspension technique during free fibular flap reconstruction after mandibulectomy with condylectomy (study group; n=9) were compared with a control group (n=9). Mandibular movement trajectory and surface electromyographic signals of bilateral masseters were recorded. The neocondyle–disc relationship was examined with magnetic resonance imaging (MRI) at 6 months after surgery.
Results:
Maximal mouth opening and bilateral marginal movement distances were comparable between the two groups (P>0.05). The asymmetry index of the condyle path length was significantly higher in controls (P=0.02). Bilateral mouth opening trajectories were symmetric in 7 patients and deviated to the affected side in 2 patients in the study group; they deviated to the affected side in all controls. The mean electromyographic values of the masseter on the affected side in resting, maximum bite, and chewing states were comparable between the two groups (P=0.13, P=0.65, and P=0.82, respectively). On MRI at 6 months, the thicknesses of the anterior, medial, and posterior bands and TMJ disc length were similar on the affected and normal sides in the study group (P=0.57, P=0.13, P=0.48, and P=0.87, respectively).
Conclusion
The proposed TMJ capsule suspension technique could improve postoperative TMJ structure and function after fibular free flap reconstruction following mandibulectomy with condylectomy.
8.Parkinsonism in Cerebral Autosomal Dominant Arteriopathy With Subcortical Infarcts and Leukoencephalopathy: Clinical Features and Biomarkers
Chih-Hao CHEN ; Te-Wei WANG ; Yu-Wen CHENG ; Yung-Tsai CHU ; Mei-Fang CHENG ; Ya-Fang CHEN ; Chin-Hsien LIN ; Sung-Chun TANG
Journal of Stroke 2025;27(1):122-127
9.Parkinsonism in Cerebral Autosomal Dominant Arteriopathy With Subcortical Infarcts and Leukoencephalopathy: Clinical Features and Biomarkers
Chih-Hao CHEN ; Te-Wei WANG ; Yu-Wen CHENG ; Yung-Tsai CHU ; Mei-Fang CHENG ; Ya-Fang CHEN ; Chin-Hsien LIN ; Sung-Chun TANG
Journal of Stroke 2025;27(1):122-127
10.Temporomandibular joint capsule suspension for neocondyle stability in free fibular flap reconstruction of the mandibular condyle
Shuang BAI ; Yao YU ; Wen-Bo ZHANG ; Ya-Qing MAO ; Yang WANG ; Chi MAO ; Dian-Can WANG ; Xin PENG
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(1):46-53
Objectives:
This study evaluates the efficacy of a new temporomandibular joint (TMJ) capsule suspension technique for stabilizing the TMJ after free fibular flap reconstruction of the mandibular condyle.
Patients and Methods:
Patients undergoing the TMJ capsule suspension technique during free fibular flap reconstruction after mandibulectomy with condylectomy (study group; n=9) were compared with a control group (n=9). Mandibular movement trajectory and surface electromyographic signals of bilateral masseters were recorded. The neocondyle–disc relationship was examined with magnetic resonance imaging (MRI) at 6 months after surgery.
Results:
Maximal mouth opening and bilateral marginal movement distances were comparable between the two groups (P>0.05). The asymmetry index of the condyle path length was significantly higher in controls (P=0.02). Bilateral mouth opening trajectories were symmetric in 7 patients and deviated to the affected side in 2 patients in the study group; they deviated to the affected side in all controls. The mean electromyographic values of the masseter on the affected side in resting, maximum bite, and chewing states were comparable between the two groups (P=0.13, P=0.65, and P=0.82, respectively). On MRI at 6 months, the thicknesses of the anterior, medial, and posterior bands and TMJ disc length were similar on the affected and normal sides in the study group (P=0.57, P=0.13, P=0.48, and P=0.87, respectively).
Conclusion
The proposed TMJ capsule suspension technique could improve postoperative TMJ structure and function after fibular free flap reconstruction following mandibulectomy with condylectomy.

Result Analysis
Print
Save
E-mail