1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
3.Research progress of berberine in neuropsychiatric diseases
Pan-pan LI ; Rui LAN ; Wen-jing HU ; Meng-ya LI ; Shui-zhi JIAO ; Ya-han LIU ; Bao-qi WANG
Chinese Pharmacological Bulletin 2025;41(7):1217-1222
Berberine is a kind of isoquinoline alkaloid extracted from the roots and rhizomes of many medicinal plants,such as Coptis chinensis of Ranunculus family,Phellodendron chinensis of rutaceae family,and Berberine Sanacanthus family.In recent years,with the deepening of research,berberine has shown re-markable prevention and treatment effect in a variety of neuro-psychiatric disease models.This paper summarizes the research progress of berberine in neuropsychiatric diseases and provides theoretical support for further clinical prevention and treatment of neuropsychiatric diseases.
4.Chemical constituents from Pyrolae Herba and their inhibitory activity against pathogenic bacteria associated with sports injuries
Ya-li LIU ; Shao-wen LIU ; Yu WANG ; Yi ZHANG ; Ji-hong WANG ; Xiao-huan ZHOU ; Su-li MA
Chinese Traditional Patent Medicine 2025;47(5):1524-1530
AIM To study the chemical constituents from Pyrolae Herba and their activity against pathogenic bacteria associated with sports injuries.METHODS Silica gel and Sephadex LH-20 were used for isolation and purification,then the structures of obtained compounds were identified by physicochemical properties and spectral data.The antibacterial activity was detected by filter paper method.RESULTS Twenty five compounds were isolated and identified as manuleoside H(1),5-hydroxy-3,7-dimethoxy-4,-methyl flavone(2),5-hydroxy-3,7,4'-methoxy-flavone(3),5-hydroxy-7,3',4'-trimethoxy-flavone(4),5,7-dihydroxy-3-methoxy-flavone(5),7.5,4'-trihydroxyflavone(6),ethyl vanillate(7),clovandiol(8),hydroxydihydrobovolide(9),zanthopyranone(10),eugenin(11),berchemol(12),3,7-dimethoxy-5,3',4'-trihydroxyflavone(13),2,5-dimethyl-7-hydroxychromone(14),rutalinium(15),formononetin(16),8-hydroxy-4',7-dimethoxy-isoflavones(17),isoline(18),dearabinosyl pneumonanthoside(19),3,5-dihydroxycinnamic acid(20),2,4,6-trihydroxyacetophenone(21),p-isopropyl benzoic acid(22),geraldone(23),ethylsyringin(24),4-hydroxyphenylethyl-2'-hydroxypropionate(25).Compounds 8,10,12,16 and 24 showed bacteriostatic zone on pathogenic bacteria susceptible to sports injuries.CONCLUSION All the compounds are isolated from Pyrolae Herba for the first time.Compounds 8,10,12,16 and 24 have inhibitory activity against pathogenic bacteria susceptible to sports injuries.
5.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]
6.Design and performance verification of high altitude adaptive oxygen generator
Bo WANG ; Xiao-feng LIU ; Wen-jia LIU ; Yi LI ; Ya-nan WU ; Shu-jie CUI ; Wei ZHANG
Chinese Medical Equipment Journal 2025;46(4):29-34
Objective To design a high altitude adaptive oxygen generator for the crews to alleviate their high altitude reaction in high altitude environment and meet their requirements for oxygen supply.Methods A high altitude adaptive oxygen generator based on the mature pressure swing adsorption oxygen production method was designed with the key technologies of discharge capacity compensation of air compression pump and airway fusion of molecular sieve tower,which had the components of molecular sieve tower,air compression pump,controller,cooling fan,cooler,solenoid valve,regulator,flow meter and etc.Trials were carried out at the simulated altitude and field plateau environment so as to verify the high altitude adaptive performance of the oxygen generator developed.Results The trial results showed the oxygen generator met the desired objectives and the requirements for oxygen volume fraction in GJB 2799-1996 General specification for medical oxygen generator using molecular sieve method.Conclusion The oxygen generartor provides oxygen supply effectively for vehicle operators in plateau environments or the ones rushing into the plateau.[Chinese Medical Equipment Journal,2025,46(4):29-34]
7.Effect of fasting blood glucose on coronary fractional flow reserve in patients with borderline coronary artery disease
Yi-wen ZHANG ; Ya-dong LIU ; Meng-xiao WANG ; Yi-ru WANG ; Yun-peng YANG ; Yun-fang SU ; Ji-xin ZHI
Chinese Journal of Interventional Cardiology 2025;33(5):272-277
Objective To explore the correlation between fasting blood glucose(FBG)level and fractional flow reserve(FFR)in patients with borderline coronary artery disease,and to clarify its potential influence on FFR measurement.Methods From August 2020 to August 2023,the data of 135 patients with coronary atherosclerotic heart disease who received coronary angiography and FFR evaluation in the Fourth Affiliated Hospital of Harbin Medical University were retrospectively collected.According to the exclusion and inclusion criteria,85 cases of borderline diseased vessels of single coronary artery with stenosis degree of 50%-80%were screened out,and they were divided into FBG≥6.1 mmol/L group(47 cases)and FBG<6.1 mmol/L group(38 cases).The baseline data,angiographic and functional indexes of the two groups were compared,and the correlation between FBG and FFR was analyzed.Results Compared with the FBG<6.1 mmol/L group,the FBG≥6.1 mmol/L group had a higher proportion of FFR negative results(72.3%vs.23.7%,P<0.001),and the FFR measurement values were generally increased[0.84(0.80,0.90)vs.0.75(0.68,0.80),P<0.001],with statistically significant differences.Pearson correlation analysis was performed on all lesions,and FFR>0.80(negative result)was positively correlated with FBG≥6.1 mmol/L(r=0.484,P<0.001).Conclusions Among the patients with borderline coronary artery disease(50%-80%stenosis)included in this study,FBG≥6.1 mmol/L is significantly correlated with FFR>0.80.For patients with borderline coronary lesions with elevated FBG,the influence of blood glucose factors should be carefully considered in clinical interpretation of FFR results.
8.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
9.Analysis of dosimetric verification results of intensity-modulated radiotherapy for breast cancer based on EPID fraction images
Xiao-hui WU ; Ya-zheng CHEN ; Zu-wen YAO ; Rui LIU ; Yang LIU ; Xiao-hua WANG
Chinese Medical Equipment Journal 2025;46(6):54-58
Objective To investigate the stability and reproducibility of the treatment fractions during the intensity-modulated radiotherapy(IMRT)for breast cancer and the effect of respiratory motion on the dose irradiation of breast cancer radiotherapy by comparing the results of breast cancer dosimetric verification based on fractionated images by an electronic portal imaging device(EPID).Methods A total of 28 IMRT patients admitted to some hospital from January to June 2023 were grouped according to the pathological results and effects of respiratory motion on the accuracy of radiotherapy during clinical treatment,including 14 cases in a breast group and 14 cases in a non-breast group with 8 ones of head and neck tumors,5 ones of esophageal cancer and 1 case of cervical cancer.All the patients underwent a scan with cone beam computed tomography(CBCT)before the first radiotherapy,and image registration was carried out with a positioning CT.An EPID was used to acquire transmission dose images of 10 fractions of radiotherapy,and γ analysis was performed using the RIT 113 QA software to compare the images of the subsequent 9 fractions with those of the first fraction,with the images of the first fraction of radiotherapy as the baseline values.Absolute maximum dose normalization was implemented under the condition of 10%dose assessment threshold,and the γ-pass rates under the 3 criteria of 2%/2 mm,3%/2 mm and 3%/3 mm were counted separately.The fraction dose verification results of the 28 patients were divided into 3 treatment phases of 2-4 times(T1),5-7 times(T2)and 8-10 times(T3)to analyze the stability of dose irradiation during the radiotherapy.SPSS 22.0 software was used for statistical analysis.Results Under the condition of 10%dose assessment threshold,the breast and non-breast groups had the γ-pass rates being(95.80±2.65)%and(94.60±6.59)%under the 2%/2 mm criterion and(98.46±1.31)%and(97.50±3.30)%under the 3%/2 mm criterion respectively,and the differences were statistically significant(all P<0.05).Under the assessment criteria of 2%/2 mm,3%/2 mm and 3%/3 mm,the breast group had the γ-pass rates of fractions of treatment significantly lower than those of the non-breast group(all P<0.05),while the γ-pass rates showed no significant differences at T1,T2 and T3 treatment phases(all P>0.05).Conclusion EPID fraction images contribute to evaluating IMRT accuracy effectively.IMRT has high stability and reproducibility during the treatment cycle,while respiration may result in dose deviation during the fraction radiotherapy for breast cancer,and optical surface tracking technology or active breathing control technology is suggested to be involved in to relieve dose deviation.[Chinese Medical Equipment Journal,2025,46(6):54-58]
10.Metabolomic analysis of Agrimonia pilosa intervention in proliferation and apoptosis of H1299 cells based on UHPLC-Q-Orbitrap MS technology
Ze-hua TONG ; Wen-jun GUO ; Meng LI ; Ya-juan XU ; Hong-ming ZHANG ; Ze-yu DOU ; Sheng-xu XIE ; Wei-fang WANG
Chinese Pharmacological Bulletin 2025;41(5):970-978
Aim To investigate the effects of Agrimonia pilosa(AP)on the proliferation and apoptosis of non-small cell lung cancer(NSCLC)H1299 cells using non-targeted metabolomics and other methods,and to explore the underlying molecular mechanisms.Meth-ods Taking H1299 cells as the research object,the effect of AP on cell proliferation and apoptosis was de-tected through CCK-8 method,colony formation,LDH,Hoechst 33258 staining,AO/EB staining,flow cytometry detection,RT qPCR and other experiments.The main differential metabolites were detected by the metabolomics method of ultra-high phase liquid chro-matography and mass spectrometry(UHPLC-Q-Orbi-trap MS),and related metabolic pathways were ana-lyzed.Results Compared with the control group,AP treatment was able to significantly inhibit the prolifera-tion and colony formation of H1299 cells,while the re-lease of LDH increased in a dose-dependent manner.Fluorescence microscopy and flow cytometry and RT-qPCR analysis revealed that H1299 cells underwent crumpling and increased nuclear fragmentation after AP administration,blocked in G0/G1 phase,up-regulated apoptotic genes caspase-3 and Bax,and down-regulated apoptosis-inducing effects of Bcl-2.Metabolomics anal-ysis screened 35 differential metabolites,which were PC(O-30∶1),D-Glutamic acid,PE(18∶0/15∶0),etc.The main metabolic pathways involved includ-ed amino acid metabolism,glycerophospholipid metabo-lism and purine metabolism so on.Conclusions AP may exert its pharmacological effects by interfering with multiple metabolic pathways in H1299 cells,inhibiting cell proliferation and promoting apoptosis.

Result Analysis
Print
Save
E-mail