1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Divergent Small Vessel Disease Burden in Warfarin-Associated and Direct Oral Anticoagulant-Associated Intracerebral Hemorrhage
Sung-Chun TANG ; Ya-Fang CHEN ; Chih-Hao CHEN ; Ching-Hua KUO ; Yuan-Chang CHAO ; Yu-Fong PENG ; Shu-Wen LIN ; Shin-Yi LIN ; Jiann-Shing JENG
Journal of Stroke 2026;28(2):334-338
3.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
4.Investigation on the mechanisms of Colquhounia Root Tablets in reversing vascular endothelial cell dysfunction of rheumatoid arthritis via modulating NOD2/SMAD3/VEGFA signaling axis
Bing-bing CAI ; Ya-wen CHEN ; Tao LI ; Yuan ZENG ; Yan-qiong ZHANG ; Na LIN ; Xia MAO ; Ya LIN
Acta Pharmaceutica Sinica 2025;60(2):397-407
Rheumatoid arthritis (RA) is a chronic autoimmune disease characterized by synovial inflammation, joint destruction, and functional impairment. Angiogenesis plays a key role in the pathological progression of RA with dysfunction of endothelial cells to promote synovial inflammation, sustain pannus formation, subsequently leading to joint damage. Colquhounia Root Tablets (CRT), a Chinese patent drug, has shown a satisfying clinical efficacy in treating RA, while the underlying mechanism by which CRT inhibits RA-associated angiogenesis remains unclear. In this study, we applied a research approach combining transcriptomic data analysis, bio-network mapping, and
5.Parkinsonism in Cerebral Autosomal Dominant Arteriopathy With Subcortical Infarcts and Leukoencephalopathy: Clinical Features and Biomarkers
Chih-Hao CHEN ; Te-Wei WANG ; Yu-Wen CHENG ; Yung-Tsai CHU ; Mei-Fang CHENG ; Ya-Fang CHEN ; Chin-Hsien LIN ; Sung-Chun TANG
Journal of Stroke 2025;27(1):122-127
6.Parkinsonism in Cerebral Autosomal Dominant Arteriopathy With Subcortical Infarcts and Leukoencephalopathy: Clinical Features and Biomarkers
Chih-Hao CHEN ; Te-Wei WANG ; Yu-Wen CHENG ; Yung-Tsai CHU ; Mei-Fang CHENG ; Ya-Fang CHEN ; Chin-Hsien LIN ; Sung-Chun TANG
Journal of Stroke 2025;27(1):122-127
7.Parkinsonism in Cerebral Autosomal Dominant Arteriopathy With Subcortical Infarcts and Leukoencephalopathy: Clinical Features and Biomarkers
Chih-Hao CHEN ; Te-Wei WANG ; Yu-Wen CHENG ; Yung-Tsai CHU ; Mei-Fang CHENG ; Ya-Fang CHEN ; Chin-Hsien LIN ; Sung-Chun TANG
Journal of Stroke 2025;27(1):122-127
8.Clinical efficacy of Wenshen Chushi Decoction combined with LIPUS on erectile dysfunction with renal deficiency and phlegm-dampness syndrome
Wen-xiong ZHU ; Yi-feng YUAN ; Tao LIU ; Bo LI ; Liu-ya LONG ; Qi-hua CHEN ; Ju-qiao HE
National Journal of Andrology 2025;31(6):519-525
Objective:To explore the clinical efficacy of Wenshen Chushi Decoction combined with low intensity pulsed ultra-sound(LIPUS)on erectile dysfunction(ED)caused by renal deficiency and phlegm-dampness syndrome.Methods:One hundred and twenty ED patients were included from the Department of Andrology in the First Hospital of Hunan University of Traditional Chinese Medicine.The patients in control group were treated with Wenshen Chushi Decoction.While the patients in observation group were trea-ted with Wenshen Chushi Decoction combined with LIPUS for 8 consecutive weeks.After the treatment,the efficacy was evaluated using the International Index of Erectile Function-5(IIEF-5)score,Penile Flow Index(PFI),Traditional Chinese Medicine Syndrome Score,Self-Rating Depression Scale(SDS)score,and Self-Rating Anxiety Scale(SAS)score.Safety was also observed.And the ef-ficacy was followed up 4 weeks after the end of treatment.Results:Fifty-seven cases were enrolled into control group finally with 55 cases in the treatment group.After the treatment,all the patients in both of groups showed an improvement in IIEF-5 scores(P<0.01).Compared with the control group(19.09±2.22),the IIEF-5 score in observation group(20.42±2.39)increased signifi-cantly(P<0.01).After the treatment,the scores of PFI,TCM syndrome and SDS in both groups decreased(P<0.01,P<0.05,P<0.01).Compared with the control group([3.77±1.21],[9.91±1.71]and[39.88±2.63]points),the observation group([2.92±1.08],[4.78±1.45],and[34.51±2.09]points)showed a more significant decrease(P<0.01).There was no significant difference in total effective rate between the two groups(P>0.05).During follow-up,the IIEF-5 scores of both groups of patients were higher than those before(P<0.05,P<0.01),and the observation group score was higher than that in the control group([17.15±3.37]vs[13.63±1.96],P<0.01).No adverse reaction and abnormality of indicators occurred in both of two groups.Conclusion:Wenshen Chushi Decoction has a significant therapeutic effect on ED caused by renal deficiency and phlegm-dampness syndrome.It can not only improve the quality of erection,but also improve the physical and mental symptoms associated with ED,which makes therapeutic effect lasting longer.
9.Cross-sectional survey of healthcare-associated infection in 5 736 medical institutions across China in 2024
Cui ZENG ; Wuqiang GAO ; Fu QIAO ; Hui ZHAO ; Xu FANG ; Linping LI ; Xiuwen CHEN ; Jiansen CHEN ; Dan LI ; Yuan ZHOU ; Lingli YU ; Qinglan MENG ; Xia MOU ; Lijuan XIONG ; Weiguang LI ; Ding LIU ; Jiaqing XIAO ; Limei OU ; Baozhen LI ; Jun YIN ; Haojun ZHANG ; Qiang FU ; Qun LU ; Biao WU ; Ya-wei XING ; Shumei SUN ; Shuncai WANG ; Longmin DU ; Jingping ZHANG ; Wen-ying HE ; Gui CHENG ; Nan REN ; Xun HUANG ; Anhua WU
Chinese Journal of Infection Control 2025;24(11):1572-1583
Objective To understand the current situation of healthcare-associated infection(HAI)in China,pro-vide data support and decision-making basis for formulating scientific and effective strategies for HAI prevention and control.Methods A nationwide cross-sectional survey on HAI was conducted among various types and levels of medical institutions in China according to a unified protocol of bedside surveys and case investigations.Results In 2024,a total of 5 736 medical institutions and 2 751 765 patients were surveyed.Among them,34 889 HAI cases were identified,with a prevalence rate of 1.27%.The number of HAI episodes was 38 032,and case prevalence rate was 1.38%.The prevalence rate of HAI in medical institutions in different regions of China ranged from 0.66%to 2.35%.Among medical institutions of different scales,those with a bed capacity of ≥900 had the high-est incidence of HAI,reaching 1.65%.The most common infection site was the lower respiratory tract(44.66%),followed by the urinary tract(12.94%),surgical site(9.32%),upper respiratory tract(7.02%),and bloodstream infection(5.78%).The top 3 departments with the highest HAI rates were the general intensive care unit(10.02%),department of neurosurgery(5.51%),and department(group)of hematology(5.34%).A total of 23 238 strains of HAI pathogens were detected,with 10 714 strains(46.10%)from lower respiratory tract speci-mens.The top 5 detected strains were Klebsiella pneumoniae(14.76%),Pseudomonas aeruginosa(13.33%),Escherichia coli(12.79%),Acinetobacter baumannii(9.23%),and Staphylococcus aureus(7.88%).231 944 pa-tients underwent class Ⅰ incision surgery were monitored,with 1 647 cases experienced surgical site infection,and the prevalence rate of surgical site infection was 0.71%.The number of patients who should undergo pathogen de-tection(patients receiving therapeutic and therapeutic combined prophylactic antimicrobial agents)was 715 179,while the actual number was 480 492,with a pathogen detection rate of 67.18%.425 225 patients received patho-genic detection before treatment,with a detection rate of 59.46%.Conclusion The overall HAI prevalence in Chi-na is lower,showing disparities among medical institutions of different regions and scales.Therefore,precise imple-mentation of measures is necessary for HAI prevention and control,with a focus on high-risk institutions and high-risk departments,key areas,and critical procedures.All levels of medical institutions should continuously reduce the incidence of HAI by strengthening monitoring,standardizing the use of antimicrobial agents,and reinforcing basic HAI prevention and control measures.
10.The Epigenetic Regulation of Decitabine Resistance in TP53-Mutated Myelodysplastic Syndromes:Integrated Analysis Based on RNA-seq and Methylomics
Lan ZHANG ; Yu-Ye REN ; Wei CHEN ; Wen-Ya HU ; Chen-Xi ZHAO ; Li-Ping SU
Journal of Experimental Hematology 2025;33(6):1681-1687
Objective:To investigate the effects of TP53 genetic status(wild-type/mutated/null)on the drug resistance of decitabine(DAC)in myelodysplastic syndromes(MDS)and identify key resistance-associated genes.Methods:Two myeloid cell lines with distinct TP53 status(M-07e:wild-type;SKM-1:mutated;)were treated with gradient DAC concentrations(0-10 μmol/L)for 0-72 h.Cell viability was detected by CCK-8 assay.RNA-Seq transcriptomics,and methylation profiling were integrated to analyze differentially expressed genes.Results:Decitabine(DAC)treatment induced time-and dose-dependent inhibition of cell viability in CCK-8 assays,with SKM-1 cells exhibiting the highest resistance(IC50=5 μmol/L vs M-07e=0.5 μmol/L,P<0.01).Transcriptomic analysis revealed 662 upregulated and 452 downregulated genes in DAC-treated M-07e cells,while SKM-1 cells showed 515 upregulated and 73 downregulated genes.By proteomic profiling,117 upregulated and 136 downregulated proteins were identified in M-07e cells,while 91 upregulated and 46 downregulated proteins were identified in SKM-1 cells following DAC exposure.Through integrated analysis of upregulated genes and proteins expression profiles,181 candidate genes were screened out,while methylation studies identified 884 hypomethylated genes with high-sensitivity loci and CpG density.Notably,31 genes overlapped between these datasets,and functional annotation indicated these drug-resistance-associated genes are primarily involved in positive regulation of cell differentiation,negative regulation of binding processes,and negative regulation of cellular component organization.Conclusion:TP53 mutations drive DAC resistance via epigenetic reprogramming.Targeting these genes may improve outcomes in TP53-mutated MDS.

Result Analysis
Print
Save
E-mail