1.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
2.Development and Validation of a Clinically Actionable Prediction Model for Postoperative Pulmonary Complications in Cardiac Surgery: A Focus on Modifiable Risk Factors
Ruoxi LI ; Meice TIAN ; Chuangshi WANG ; Yujia HUANG ; Weinan CHEN ; Ya SONG ; Bomiao LIU ; Liu DU ; Xue FENG
Annals of Rehabilitation Medicine 2026;50(1):50-61
Objective:
To develop and validate a clinically actionable prediction model for postoperative pulmonary complications (PPCs) in cardiac surgery patients, focusing on modifiable preoperative risk factors amenable to targeted optimization.
Methods:
In this prospective observational cohort study, 492 adults undergoing open-chest cardiac surgery between August 15, 2023 and December 31, 2023 were analyzed. Prespecified predictors included gas exchange variables, pulmonary function, inspiratory muscle strength, and physical performance. Univariable and multivariable logistic regression analyses were used to develop the prediction model. Discrimination was assessed by the area under the receiver operating characteristic curve (AUC).
Results:
A total of 90 patients (14.1%) developed PPCs after surgery. Five independent predictors were identified: elevated arterial PaCO2 (odds ratio [OR] 1.12, 95% confidence interval [CI] 1.00–1.26), oxygen desaturation (SpO2<93%) (OR 12.47, 95% CI 3.51–48.13), reduced gait speed (OR 0.17, 95% CI 0.04–0.71), lower FEV1/FVC ratio (OR 0.96, 95% CI 0.92–1.00), and diminished inspiratory muscle strength (MIP % predicted) (OR 0.96, 95% CI 0.92–0.99). The model demonstrated good discriminative ability with an AUC of 0.86 (95% CI 0.80–0.93) in the training cohort and 0.87 (95% CI 0.74–0.93) in the validation cohort.
Conclusion
This parsimonious model achieved high predictive accuracy using five modifiable physiological variables. By targeting abnormalities in gas exchange, pulmonary mechanics, muscle strength, and functional reserve, the model offers a practical tool to guide individualized prehabilitation strategies for reducing PPC risk in cardiac surgery patients.
3.A new species of Culicoides (Avaritia) (Diptera: Ceratopogonidae) in Heilongjiang Province, China
Ya-yu WANG ; Jiang-fan LI ; Bo-qiao CAI ; Guo-ping LIU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):62-65
This study reports a new species of Culicoides(Avaritia)isolated from Xunke County, Heilongjiang Province, China. The new species, Culicoides(Avaritia)dongshanensis Liu et Wang, sp. nov., was identified and illustrated based on female adults. Its diagnostic characteristics are as follows: eyes contiguous over a short distance, with short interfacetal hair, antennal ratio(AR)of 1.20, palpal ratio(PR)of 2.16, wing length of 0.83 mm, mandible with 15 teeth, one pale spot in base cell M1, one pale spot in cell M4, two pale spots in cell A, and two unequal spermathecae. Type specimens were deposited at the Center for Disease Control and Prevention of the Northern Theater Command.
4.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
5.An animal model of severe acute respiratory distress syndrome for translational research
Kuo‑An CHU ; Chia‑Yu LAI ; Yu‑Hui CHEN ; Fu‑Hsien KUO ; I.‑Yuan CHEN ; You‑Cheng JIANG ; Ya‑Ling LIU ; Tsui‑Ling KO ; Yu‑Show FU
Laboratory Animal Research 2025;41(1):81-92
Background:
Despite the fact that an increasing number of studies have focused on developing therapies for acute lung injury, managing acute respiratory distress syndrome (ARDS) remains a challenge in intensive care medicine.Whether the pathology of animal models with acute lung injury in prior studies differed from clinical symptoms of ARDS, resulting in questionable management for human ARDS. To evaluate precisely the therapeutic effect of trans‑ planted stem cells or medications on acute lung injury, we developed an animal model of severe ARDS with lower lung function, capable of keeping the experimental animals survive with consistent reproducibility. Establishing this animal model could help develop the treatment of ARDS with higher efficiency.
Results:
In this approach, we intratracheally delivered bleomycin (BLM, 5 mg/rat) into rats’ left trachea via a needle connected with polyethylene tube, and simultaneously rotated the rats to the left side by 60 degrees. Within sevendays after the injury, we found that arterial blood oxygen saturation (SpO2 ) significantly decreased to 83.7%, partial pressure of arterial oxygen (PaO2 ) markedly reduced to 65.3 mmHg, partial pressure of arterial carbon dioxide (PaCO2 )amplified to 49.2 mmHg, and the respiratory rate increased over time. Morphologically, the surface of the left lung appeared uneven on Day 1, the alveoli of the left lung disappeared on Day 2, and the left lung shrank on Day 7. A his‑ tological examination revealed that considerable cell infiltration began on Day 1 and lasted until Day 7, with a larger area of cell infiltration. Serum levels of IL-5, IL-6, IFN-γ, MCP-1, MIP-2, G-CSF, and TNF-α substantially rose on Day 7.
Conclusions
This modified approach for BLM-induced lung injury provided a severe, stable, and one-sided (left-lobe) ARDS animal model with consistent reproducibility. The physiological symptoms observed in this severe ARDS animal model are entirely consistent with the characteristics of clinical ARDS. The establishment of this ARDS animal model could help develop treatment for ARDS.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Application Value of Gastric Contrast-Enhanced Ultrasound in the Diagnosis of Extraluminal Duodenal Diverticulum.
Acta Academiae Medicinae Sinicae 2025;47(5):733-737
Objective To evaluate the value of gastric contrast-enhanced ultrasound in diagnosing extraluminal duodenal diverticulum. Methods A retrospective analysis was conducted on 40 cases of extraluminal duodenal diverticula confirmed by upper gastrointestinal barium meal and gastroduodenoscopy,all of whom underwent gastric contrast-enhanced ultrasound examination.The detection rate and imaging features of duodenal diverticula were retrospectively analyzed. Results Gastric contrast-enhanced ultrasound detected 34 out of 40 cases of extraluminal duodenal diverticula,with the detection rate (85.0%) higher than that (10.0%,4/40) of conventional fasting ultrasound (P<0.001).Gastric contrast-enhanced ultrasound demonstrated higher detection rate for single diverticula than for multiple diverticula (97.1% vs.44.4%,P<0.001) and was particularly effective for duodenal diverticula in the descending segment (91.7%).According to imaging features,duodenal diverticula were classified into sac-like,gas-containing mass,and air-line types. Conclusion Gastric contrast-enhanced ultrasound facilitates the detection of extraluminal duodenal diverticula in the descending segment,allows concurrent visualization of biliary-pancreatic system pathologies,and enables comprehensive assessment of the association between duodenal diverticula and biliary-pancreatic diseases,demonstrating significant clinical value.
Humans
;
Diverticulum/diagnostic imaging*
;
Male
;
Retrospective Studies
;
Duodenal Diseases/diagnostic imaging*
;
Ultrasonography
;
Female
;
Middle Aged
;
Contrast Media
;
Aged
;
Adult
;
Young Adult
8.Electrochemical Fabrication of Molecularly Imprinted Surface-enhanced Raman Scattering Chips for Highly Selective Detection of Bisphenol A
Shu-Chen LIU ; Man-Mei TIAN ; Zhou-Ya WU ; Yuan-Ting LI
Chinese Journal of Analytical Chemistry 2025;53(10):1631-1641
A portable molecularly imprinted(MIP)surface-enhanced Raman scattering(SERS)chip was fabricated via a green electrochemical approach for highly selective detection of bisphenol A(BPA).This MIP-AuNP/UIO-66/SPE sensor was fabricated through a single-step co-deposition process.The process involved electropolymerization onto a UIO-66 modified screen-printed electrode(SPE),by usingo-phenylenediamine(OPD)as functional monomer and BPA as template,and simultaneously electro-reduction generated gold nanoparticles(AuNPs),which served as the SERS-active substrate.Ultimately,this one-step method formed a three-dimensional porous architecture on the electrode surface.Under 785 nm laser excitation,the sensing chip exhibited a highly sensitive SERS response towards BPA.The intensity of its characteristic peak at 850 cm-1 showed a good linear relationship with logarithm of BPA concentration in the range of 1.0×10-10 to 1.0×10-6 mol/L,with a detection limit of 1.0×10-12 mol/L.More importantly,the fabricated chips maintained highly selective binding affinity for BPA in water samples even in the presence of structural analogs bisphenol F(BPF)and bisphenol S(BPS).When the chip was applied to detection of BPA in water samples from plastic bottle and paper cup,the recovery rates ranged from 94.0%to 103.0%with relative standard deviations(RSD)less than 4.7%.The developed chip offered a highly sensitive and selective solution for detection of trace BPA in complex water samples.
9.Dual-modal Ultraviolet-Fluorescence Sensor Based on Acetaldehyde Dehydrogenase/Bovine Serum Albumin System for Acetaldehyde Detection in Food
Feng LI ; Ya-Hao LIU ; Kun GE ; Lun-Zhao YI
Chinese Journal of Analytical Chemistry 2025;53(11):1931-1939,中插53-中插57
In this study,an ultraviolet(UV)/fluorescence dual-modal sensor was constructed by combining the catalytic properties of aldehyde dehydrogenase(ALDH)with the fluorescence inner filter effect of bovine serum albumin(BSA),realizing highly sensitive and highly selective detection of acetaldehyde in food.Acetaldehyde could react with oxidized coenzyme I(NAD+)to generate acetic acid and reduced coenzyme I(NADH)under catalytic condition by ALDH,and a quantitative relationship between acetaldehyde concentration and UV signal for UV detection based on the characteristic UV absorption peak of NADH at 340 nm was established.Meanwhile,an acetaldehyde detection channel based on fluorescence signal changes was built on the basis of the property that the fluorescence emission of BSA(as a fluorescent indicator)at 340 nm could be effectively quenched by the generated NADH,thus forming a″one-reaction dual-signal″detection mode.The experimental results showed that the acetaldehyde concentration in the range of 0.01?5.0 mg/L had a good linear relationship with both UV and fluorescence signals,and the limit of detection(LOD)was 0.003 mg/L for the UV mode and 0.005 mg/L for the fluorescence mode,and no significant fluctuations were observed when 50-fold concentrations of acetaldehyde analogs and common interfering substances were added.When the dual-modal sensor was applied to detection of acetaldehyde in food samples such as yogurt and wine,the relative error between its quantitative results and those of high-performance liquid chromatography(HPLC)was less than±4.0%.The dual-modal cross-validation strategy could improve the detection reliability through signal mutual verification,providing an innovative solution for the rapid detection of acetaldehyde contamination in food.
10.Thoughts and Practices on the Development of Forensic Medicine Discipline in the Perspective of Building a Regional High-Level Medical University
Guang CHEN ; Rong-Shuai WANG ; Li SU ; Yue ZHANG ; Xue-Xia LIU ; Shi-Yong FANG ; Zhan-Zhan LIU ; Ya-Jun XU ; Xiang XU
Journal of Forensic Medicine 2025;41(1):35-39
Under the background of forensic medicine becoming a first-level discipline,the opportuni-ties and challenges of discipline development coexist.Starting from the actual situation and characteris-tics of local medical colleges and universities,this paper discusses the problems and solutions for the development of forensic medicine discipline from the perspective of building a regional high-level medical university.Combined with the experiences of carrying out forensic medicine education in our college,this paper supplies our thoughts and practices on improving the discipline system,enhancing the ability to serve society,perfecting the talent cultivation model and promoting forensic culture,to provide reference and inspiration for the development of forensic medicine in other universities,jointly promote the advancement of forensic medicine in China to a new stage,and contribute the wisdom and strength of forensic medical experts to the construction of a law-based China,a safe China and a healthy China.


Result Analysis
Print
Save
E-mail